
Thermo Scientific KingFisher Flex Purification System, 96 PCR Head
Automated magnetic-particle nucleic acid and biomolecule purification instrument
Medical equipment and biomedical engineering.
Abuja, Nigeria.
Buy nucleic acid purification equipment and kits in Nigeria through Franance. Browse manual DNA/RNA extraction kits and compare QIAcube Connect, KingFisher Flex and KingFisher Apex by supported method, sample, configuration and throughput before requesting a quotation.
34 models

Automated magnetic-particle nucleic acid and biomolecule purification instrument

Automated magnetic-particle sample purification system

Automated nucleic-acid and protein sample-preparation instrument





















Request an itemised quotation from Franance for a nucleic acid purification system in Nigeria. Start with the current nucleic acid purification equipment listing, then identify the actual system and configuration your laboratory needs: QIAGEN QIAcube Connect, KingFisher Flex 5400610 or KingFisher Apex 5400910.
Read moreThe current assigned products are three instruments. The QIAGEN QIAcube Connect automates selected QIAGEN kit workflows for up to 12 samples per run. Thermo Scientific KingFisher Flex catalogue 5400610 is a magnetic-particle processor with a 96 PCR head. KingFisher Apex catalogue 5400910 is the corresponding Apex system configuration with a 96 PCR head. The category contains these three records at the time of this review; it is not an exhaustive list of every extraction instrument, kit, reagent or accessory available from either manufacturer.
Read moreChoose by the method that the laboratory needs to run, not by a headline sample count alone. Establish whether the required output is genomic DNA, plasmid DNA, total RNA, viral nucleic acid, or another defined target. Record the source material, sample preparation steps, expected input range, inhibitor or biosafety considerations, extraction kit, downstream assay, number of specimens per batch and daily workload. Have the scientific lead and laboratory quality team decide what performance and process documentation they require.
Read moreBuy nucleic acid purification equipment in Nigeria through Franance by matching the instrument to the extraction method, sample type, daily throughput and approved kit or consumables. The category includes manual nucleic acid extraction kits and three automated systems: the QIAGEN QIAcube Connect, Thermo Scientific KingFisher Flex with a 96 PCR head (catalogue 5400610), and KingFisher Apex with a 96 PCR head (catalogue 5400910). These platforms use different workflow designs and their own supported configurations; they are not interchangeable just because each can support nucleic-acid purification. Franance can receive a quote order and follow up by phone or email. The site does not take online payment, and current price, stock, availability, delivery and service terms must be confirmed for the exact proposed system and Nigerian destination.
Request an itemised quotation from Franance for a nucleic acid purification system in Nigeria. Start with the current nucleic acid purification equipment listing, then identify the actual system and configuration your laboratory needs: QIAGEN QIAcube Connect, KingFisher Flex 5400610 or KingFisher Apex 5400910.
For a useful proposal, include what will be extracted, which samples and kit or protocol are approved, the number of samples per batch and per day, the required turnaround, and what your laboratory already owns. Ask for the instrument package and every proposed accessory or consumable to be named by manufacturer reference. If installation, operator orientation, method transfer, validation support, service or a supply of reagents is required, request each as a distinct line with scope and terms. Franance can review the request and contact you; the catalogue does not establish live Nigerian stock, a fixed price or a delivery commitment.
The current assigned products are three instruments. The QIAGEN QIAcube Connect automates selected QIAGEN kit workflows for up to 12 samples per run. Thermo Scientific KingFisher Flex catalogue 5400610 is a magnetic-particle processor with a 96 PCR head. KingFisher Apex catalogue 5400910 is the corresponding Apex system configuration with a 96 PCR head. The category contains these three records at the time of this review; it is not an exhaustive list of every extraction instrument, kit, reagent or accessory available from either manufacturer.
The models differ in process design and in supported consumables. QIAcube Connect automates selected manual workflows for compatible QIAGEN kits. KingFisher systems move magnetic particles through prepared plates or other supported labware; the sample and reagents are prepared into the prescribed positions before the run. They are not general-purpose liquid handlers, and a protocol that works on one family is not automatically a supported protocol on another. Review the assigned configuration and current manufacturer documentation before deciding whether a listing matches a validated laboratory method.
Choose by the method that the laboratory needs to run, not by a headline sample count alone. Establish whether the required output is genomic DNA, plasmid DNA, total RNA, viral nucleic acid, or another defined target. Record the source material, sample preparation steps, expected input range, inhibitor or biosafety considerations, extraction kit, downstream assay, number of specimens per batch and daily workload. Have the scientific lead and laboratory quality team decide what performance and process documentation they require.
Then compare which exact instrument and protocol are documented for that method. For QIAcube Connect, identify the QIAGEN kit and protocol version and confirm that they are supported by the current instrument instructions. For KingFisher Flex or Apex, identify the magnetic-particle chemistry, protocol file, plate format, tip comb and magnetic head required. Ask the manufacturer or technical supplier to confirm the complete combination in writing. The equipment name alone is not proof that a particular extraction kit, sample matrix, assay, or locally validated procedure is compatible.
Consider sample volumes, batch size, hands-on preparation, processing time, unattended steps, operator training and the consequences of an interrupted run. Compare practical throughput across the complete workflow, including sample identification, lysis, loading, elution, downstream testing and cleaning. Do not equate a system's maximum capacity with routine daily capacity; staffing, method time, batch design, reagent availability and quality-control checks all affect real throughput.
QIAGEN describes QIAcube Connect as an automated sample-preparation system for selected QIAGEN kits and protocols, processing up to 12 samples per run. Manufacturer materials describe supported workflows for selected RNA, genomic DNA, plasmid DNA, viral nucleic acid and protein purification, as well as nucleic-acid cleanup. The system includes an integrated centrifuge, heated shaker, pipetting system, UV LED and robotic gripper, according to its documentation. These features belong to a particular automation architecture; they do not make the instrument compatible with every extraction kit or method.
When requesting a QIAcube Connect quotation, give the kit catalogue number, sample material, target and intended protocol. State whether the lab already has the required rotor, plasticware, reagents and other kit components, and ask exactly what the offered package includes. Clarify the number of samples you intend to process per batch and per shift. Ask for the current instrument manual and protocol compatibility information relevant to the proposed workflow.
QIAGEN's public product information supports a maximum of 12 samples per run for the system and selected kit workflows. It does not support a general claim that any 12 samples can be extracted, that every kit is automated, or that the instrument produces a particular yield or purity for a facility's sample. Confirm the workflow and acceptance criteria with QIAGEN's documentation and the laboratory's own validation process.
Thermo Fisher identifies catalogue number 5400610 as a KingFisher Flex Purification System with a 96 PCR head. The Flex uses magnetic-particle processing for compatible purification methods. During a supported run, magnetic beads are moved through the prescribed bind, wash and elution steps; the instrument is not dispensing and aspirating the liquid sample in the manner of an automated pipetting station. Thermo Fisher lists the Flex family for DNA/RNA, protein and cell purification applications depending on the protocol, kit and sample.
The KingFisher Flex 5400610 listing is one head configuration. The Flex product family has other head and plate formats, but those should not be assumed included with 5400610. Confirm the head supplied, instrument package, supported plate type, magnetic tip combs, protocol, compatible reagents and any software or computer requirement against the current order documentation. If a laboratory requires larger processing volumes or another plate type, do not assume that the 96 PCR configuration fulfils the requirement; ask the manufacturer to identify the correct configuration.
Thermo Fisher documentation gives workflow-specific capacities and ranges. Do not present a single volume or run-time figure as applying to every sample, extraction chemistry or protocol. Request method-specific guidance for the intended kit and target, and have the laboratory check the sample preparation, elution volume and downstream assay requirements before approval.
Thermo Fisher catalogue number 5400910 identifies the KingFisher Apex Purification System with a 96 PCR head. The Apex family uses magnetic-particle processing to automate selected purification or isolation workflows for DNA, RNA, proteins and cells. The manufacturer's system materials describe multiple head options, which are separate configurations. The selected head and associated consumables determine the plate format and compatible workflow.
The KingFisher Apex 5400910 listing is specifically the 96 PCR-head product record. Thermo Fisher says that the Apex and Flex magnetic heads are not interchangeable. Therefore, a Flex head already owned by a laboratory must not be presumed to fit an Apex, or vice versa. Confirm instrument, head, heating block if required, plates, tip combs, adapters, protocol and software components as a coherent configuration.
Ask whether the exact application has an applicable validated protocol and whether its sample range and outputs align with the laboratory's requirement. The Apex's advertised maximum sample counts describe system capacity under suitable configuration, not a guaranteed extraction result or a promise of a given daily throughput. For a regulated, clinical or otherwise quality-managed workflow, the responsible laboratory must establish its method suitability and acceptance criteria under its own quality system.
No. They use distinct workflow designs, instrument components, method files and consumables. QIAcube Connect is intended for selected QIAGEN kits and protocols using the instrument's specified sample-preparation operations. KingFisher Flex and Apex use magnetic-particle processing with a compatible head, plate and tip-comb arrangement. A similar target such as DNA or RNA does not prove that a kit or protocol transfers between these systems.
Compare the exact extraction method, sample input and kit first. If considering a substitute, ask the manufacturer to confirm the alternative instrument's support for the exact matrix, target, chemistry, plate, protocol and output needed. Request the evidence and compatibility statement, then have the lab's technical and quality owners assess it. A supplier quotation or a generic application list is not a method validation. Do not replace an approved system in a tender or established procedure without the institution's review.
The question is not merely whether both instruments can process nucleic acids. It is whether the proposed instrument and current configuration support the laboratory's named extraction workflow and fit its downstream requirements. Keep those claims separate in the purchase specification and in any comparison table.
Buy manual DNA, RNA, miRNA and combined extraction kits from the dedicated extraction-kit range. Choose by starting material and target, not by brand alone. List the complete run materials separately from any instrument. Depending on the supported method, these can include the named extraction kit, lysis or wash reagents, elution material, plates, tubes, tip combs, adapters and other protocol-specific plastics. Record every catalogue number and the amount required per run, together with the batch size and expected purchasing period. Do not assume that consumables shown in a product image, manual or application protocol are part of the instrument package.
For a QIAcube workflow, ask which QIAGEN kit reference and supplied components are intended, and whether the selected protocol requires additional plastics or accessories. For KingFisher Flex or Apex, identify the magnetic-head/plate format and matching tip comb and plates. Check whether the proposed plasticware is compatible with the exact head and protocol. Do not reuse a code from a different head family because the product names are similar.
Ask the quotation to separate instrument, kit, consumable and accessory pricing and quantities. Confirm order units, pack sizes, expiry or remaining shelf life required at receipt, storage conditions and any cold-chain or hazardous-material handling that applies to the particular reagent. Such conditions are product-specific; this guide does not assign them to an unspecified kit. Have the lab's technical owner approve equivalence before any alternate consumable or reagent is accepted.
Before ordering, request the current site-preparation documents for the exact model and configuration. Review bench dimensions, instrument weight, clearance, room conditions, electrical supply and outlet/plug, grounding, ventilation, network or computer requirements and any relevant safety controls. Confirm that these requirements are met at the intended location. Manufacturer specifications for one regional variant should not be assumed to describe the supplied unit; have the quotation identify the electrical and accessory configuration.
Plan how samples and reagents move through the room, where pre- and post-amplification work occurs, and how contamination-control practices are maintained. Equipment placement cannot itself establish that a molecular laboratory's layout or workflow is suitable. The institution's biosafety, laboratory quality and facilities teams remain responsible for the site and procedures.
If commissioning, installation, connectivity, training or method transfer is needed, specify it as a request rather than presuming it is included. Ask the seller to state who performs the work, its scope, prerequisites, deliverables, schedule, travel or site costs, warranty interaction and exclusions. Confirm support availability for your city and state in writing. The manufacturer's product page alone does not prove that local service is available or that a particular service package is offered with the listed equipment.
Send Franance the system name and exact model or catalogue number, quantity, laboratory name and contact, Nigerian city and state, and the purchasing or project timeline. State the target (DNA or RNA and its type), sample source and approximate sample count per batch and per day. Name the extraction kit, manufacturer reference, protocol version, plate or tube format, required elution and downstream assay. Tell us whether you need the instrument only or a complete supply including kits, plastics, accessories, installation, training or service.
Attach the approved specification or tender schedule if there is one, but do not include patient-identifiable or confidential sample data in a general enquiry. Ask for a written response that identifies the exact instrument configuration and all included/excluded parts. The quote should state the unit and pack basis, current availability, price and currency, validity, delivery terms and timing estimate, warranty and service scope, installation/training scope and any required documentation. Ask the supplier to identify substitutions clearly instead of silently replacing a catalogue reference.
For QIAcube Connect, specify the exact supported QIAGEN kit and protocol. For 5400610 and 5400910, name the KingFisher model, head, plate format, tip comb and protocol-specific consumables. Explain what the lab already has so the proposed package does not double-count equipment or omit a required component. Franance will follow up by phone or email to clarify the requirement and quotation; there is no online checkout or payment.
Compare equivalent systems and quote scopes. An instrument-only quotation is not comparable with a package that includes extraction kits, plastics, software, installation or training. Align the precise model and head, supported workflow, number of instruments, consumable quantities, shipping and site-work scope. Check whether prices are one-time, recurring or conditional, and confirm the currency, validity period, taxes or import charges and delivery responsibility in the written offer.
Franance displays starting-at prices only where a product record includes one; a price is not an online transaction or a guarantee of current availability. These current category records do not establish a live Nigerian stock position or fixed price. Request a fresh written quotation for the exact configuration and delivery location. Avoid comparing a theoretical throughput or general product-family price with an order that has different accessories, kits or service requirements.
If the initial budget is limited, ask for alternatives to be quoted as separate, clearly identified options. The technical team should assess whether each option meets the required method, sample matrix, capacity and quality criteria before procurement compares cost. Do not let a lower headline price obscure the purchase of an incompatible head, unsupported protocol or incomplete consumable package.
No. Franance accepts quote orders and follows up by phone or email; it does not take online payment for this equipment. Use the category listing to review the assigned products, select the exact manufacturer reference and send a quotation request. The catalogue is for discovery and enquiry, not a paid checkout or confirmed stock reservation.
Wait for a written response that names the product, configuration, price, availability, delivery terms, service scope and any included consumables. Check it against the institution's approved specification before placing an order. The final purchase terms and any order acceptance should be handled through the confirmed quotation process.
Open the nucleic acid purification category and choose the relevant filtered product listing: QIAGEN QIAcube Connect, Thermo Scientific KingFisher Flex 5400610, or Thermo Scientific KingFisher Apex 5400910. Contact Franance about a nucleic acid purification quote order with your laboratory, exact model, use case, expected throughput, compatible kit/protocol and destination.
Franance can then contact you by phone or email to clarify details and return the quotation. Include a suitable institutional contact and a delivery address or destination city/state. Ask the proposal to call out the exact offered configuration and any optional materials or work, so the technical and procurement reviewers can assess the same scope. Current stock, price and timing are confirmed through that response, not inferred from this guide or from a manufacturer page.
### Which products are in this category now?
The three assigned listings are QIAGEN QIAcube Connect, Thermo Scientific KingFisher Flex 5400610 with a 96 PCR head, and KingFisher Apex 5400910 with a 96 PCR head. This is the reviewed current category assignment, not a complete manufacturer catalogue.
### What is the largest batch these systems can process?
QIAGEN states up to 12 samples per run for QIAcube Connect. The listed KingFisher Flex and Apex configurations use 96 PCR heads; exact usable capacity, method and sample compatibility depend on the specified protocol and consumables. Ask the manufacturer to confirm the intended workflow rather than infer routine throughput from the head label.
### Can I use a KingFisher Flex head on the Apex?
Thermo Fisher documentation says Flex and Apex heads are not interchangeable. Check the correct head and supporting plate/tip-comb components for the named instrument configuration.
### Does Franance confirm Nigerian stock or delivery time on this page?
No. Ask for a current written quotation for the exact instrument, accessories, consumables and destination. Availability, delivery estimate, price and service conditions are confirmed in the quote.
### What should I send first?
Send the exact model or catalogue number, sample and target, named kit/protocol, required batch and daily volumes, plate format, included items needed, quantity and Nigerian destination. Attach a non-confidential approved specification if available.
Yes. Include the brand, exact model or catalogue reference. If alternatives are acceptable, identify the essential requirements and ask for any proposed substitute to be reviewed before approval.
No stock commitment is made by a category listing. Ask the team to confirm the exact product, quantity, configuration and availability in the quotation.
No online payment is taken. A quote order records your requirements; price and supply terms need confirmation before an order is agreed.
Yes. Keep products and quantities separate and explain which department or delivery site each item belongs to. Include a contact who can coordinate technical and purchasing questions.
Send the equipment name, preferred manufacturer or model and required specification to info@franance.com. The team can review the enquiry and confirm whether an appropriate supply can be proposed.
Send the product names, quantities, specifications and delivery location. We’ll discuss the proposed equipment and supply terms with you.
Contact FrananceAdd the models you need to a quote order, or send us your equipment list.
