Buy Laboratory Homogenizers and Sonicators in Nigeria.

Buy laboratory homogenizers and sonicators in Nigeria through Franance by first matching the processing method to your sample. The category lists a Sonics VCX 130 ultrasonic processor, IKA T 25 easy clean digital Solution 0010015162 rotor-stator disperser and BIOBASE BH-50P high-speed homogenizer. These instruments use different mechanisms and are not interchangeable. Choose from sample volume, viscosity, processing objective, tool or probe, cleaning needs and electrical supply, then request a model-specific quotation. Franance receives quote orders and follows up by phone or email; online payment is not available.

Products

10 models

Filter all 10 products

Which homogenizers and sonicators can I buy in Nigeria?

The homogenizers and sonicators category has three assigned products: Sonics VCX 130, IKA T 25 easy clean digital Solution 0010015162, and BIOBASE BH-50P. The listing brings different liquid-processing methods together under one category, but the instruments do not share the same mechanism or sample envelope.

Read more

How do ultrasonic processors and rotor-stator homogenizers differ?

An ultrasonic processor transmits high-frequency mechanical energy into a liquid through a probe. Sonics describes the VCX 130 as a 20 kHz processor with programmable operation, pulse mode and variable power. Probe diameter and geometry, immersion, vessel, sample properties and settings influence how energy is coupled into the sample. Sonics states that the product's actual processing volume depends on the selected probe or accessory and the application.

Read more

Which Sonics VCX 130 ultrasonic processor is listed in Nigeria?

Franance lists the Sonics VCX 130 Ultrasonic Processor. Sonics' VCX-130-110 page describes a programmable 130 W processor operating at 20 kHz, with pulse mode, variable power, a 10-hour timer and wattage and energy display. The named -110 package includes a 6 mm (¼-inch) titanium-alloy probe stated for 10–50 mL volumes. The manufacturer notes that the support stand is sold separately and that export voltage should be specified.

Read more

Buy Laboratory Homogenizers and Sonicators in Nigeria

Direct answer: Franance lists three laboratory liquid-processing systems in Nigeria: Sonics VCX 130 ultrasonic processor, IKA T 25 easy clean digital Solution 0010015162 rotor-stator disperser, and BIOBASE BH-50P high-speed homogenizer. The Sonics unit uses ultrasonic energy; the IKA and BIOBASE units use dispersing heads. They serve different process needs. Select by sample, vessel, volume, viscosity, tool, power and cleaning requirements, then request a model-specific quote. Franance follows up by phone or email; the site does not take online payment.

Which homogenizers and sonicators can I buy in Nigeria?

The homogenizers and sonicators category has three assigned products: Sonics VCX 130, IKA T 25 easy clean digital Solution 0010015162, and BIOBASE BH-50P. The listing brings different liquid-processing methods together under one category, but the instruments do not share the same mechanism or sample envelope.

Sonics VCX 130 is an ultrasonic processor with a probe. IKA T 25 and BIOBASE BH-50P are rotor-stator-style dispersers/homogenizers with interchangeable or selected dispersing tools. Determine whether the sample requires ultrasonic processing or mechanical high-shear dispersion before you compare product names. Also identify the sample volume, viscosity, vessel, temperature limits, process time, cleaning method and electrical supply.

The manufacturer ranges are starting points for a technical discussion, not a guarantee that a given sample will produce the desired result. Ask the manufacturer or supplier to confirm the chosen instrument and tool for the actual matrix and method. Franance can receive the requested model and configuration and follow up with a quote by phone or email.

How do ultrasonic processors and rotor-stator homogenizers differ?

An ultrasonic processor transmits high-frequency mechanical energy into a liquid through a probe. Sonics describes the VCX 130 as a 20 kHz processor with programmable operation, pulse mode and variable power. Probe diameter and geometry, immersion, vessel, sample properties and settings influence how energy is coupled into the sample. Sonics states that the product's actual processing volume depends on the selected probe or accessory and the application.

IKA describes its T 25 dispersers as using the rotor-stator principle: a rotating element works inside a stationary stator to generate shear. The T 25 has a range of S 25 tools. BIOBASE describes BH-50P as a handheld high-speed homogenizer with different dispersing heads and head-dependent volume and viscosity ranges; the cited BH-50P page does not name its mechanical principle, so confirm that detail with the manufacturer if it matters to your process. For both products, the selected tool and its fit to the sample are part of the system specification. Motor speed alone does not define the result.

Because the methods differ, do not substitute one for the other solely because both are called a homogenizer or can break up material. Define the desired process, sample sensitivity, batch size and validated method with the laboratory. If the outcome is uncertain, request an application review or trial from the manufacturer or qualified supplier before committing to a production protocol.

Which Sonics VCX 130 ultrasonic processor is listed in Nigeria?

Franance lists the Sonics VCX 130 Ultrasonic Processor. Sonics' VCX-130-110 page describes a programmable 130 W processor operating at 20 kHz, with pulse mode, variable power, a 10-hour timer and wattage and energy display. The named -110 package includes a 6 mm (¼-inch) titanium-alloy probe stated for 10–50 mL volumes. The manufacturer notes that the support stand is sold separately and that export voltage should be specified.

The category record is named “VCX 130” and the Sonics page identifies a particular -110 variant. For a Nigerian installation, specify the required 220–240 V / 50–60 Hz configuration and ask for the exact full model suffix. Do not assume that the -110 electrical variant suits the site supply or that a voltage transformer is included. Confirm the rating plate, cable, fuse and instructions for the proposed model.

Choose a probe to match sample volume, vessel and processing objective. Sonics lists alternate probes and accessories with distinct volume ranges. The standard probe's 10–50 mL indication should not be stretched to a different volume without manufacturer guidance. Request the exact probe part number, tip diameter, material, length and cleaning instructions. If the process requires a stand, clamp or sound enclosure, include it in the quote because the stand is not included with the referenced -110 package.

Which IKA T 25 easy clean digital Solution can I request in Nigeria?

The category lists IKA T 25 easy clean digital Solution, Ident. No. 0010015162. IKA's technical-data page gives a 3,000–25,000 rpm speed range, 500 W input and 400 W motor output, batch processing, brushless DC motor, timer and Micro-USB interface. Its stated volume range is 0.001–2 L for water, and it lists a maximum viscosity of 5,000 mPa·s. Those are model specifications and do not guarantee the same usable range with every sample or tool.

The product record is the Solution package, not a bare motor unit. Its package details identify an S 25 EC-C-25 G dispersing tool, R 1826 plate stand and R 182 clamp. Ask Franance to confirm that these components and the exact item number are included in the offer. IKA provides other voltage variants; specify 220–240 V / 50–60 Hz for evaluation in Nigeria and verify the delivered label and power supply.

IKA describes its tool range as supporting different dispersion tasks. Confirm tool material, geometry, cleaning and compatibility with the sample and vessel. The listed water-volume span is not a recipe or universal guarantee for viscous, abrasive, temperature-sensitive or otherwise difficult samples. Share the sample details with the supplier and follow the current operating instructions.

Which BIOBASE BH-50P laboratory homogenizer is listed in Nigeria?

Franance lists the BIOBASE BH-50P Laboratory Homogenizer. BIOBASE's manufacturer page identifies the BH-50P as a handheld homogenizer and lists 7,000–30,000 rpm, 1,300 W consumption and a work stand with one selected standard work head among the standard accessories. The page lists head choices such as 18G/18F, 20G/20F, 25G/25F and 30G/30F and shows that head-specific processing volumes and applicable viscosity limits differ.

The exact work head is central to the purchase. Tell the supplier the batch volume, viscosity range, vessel opening, sample characteristics and cleaning method, then ask for the proposed head code and current manufacturer specification. BIOBASE's page presents different table ranges and head options; do not treat the broad family volume as the guaranteed range of every head. Verify the exact selected head, the vessel and the product's operating limits.

The manufacturer lists AC 220 V ±10%, 50/60 Hz as standard and AC 110 V ±10%, 50/60 Hz with an external transformer as optional. Specify the intended Nigeria mains configuration and confirm the proposed motor, transformer if needed, plug and included components. If a work stand is required for the procedure, ask which stand is supplied and how the selected head is mounted.

How do I choose a probe, dispersing head and working volume?

Write a short application brief before choosing accessories. State the sample's composition, batch size, expected viscosity, vessel diameter and depth, processing objective, number of batches and any sensitivity to temperature, air entrainment or contamination. Provide the laboratory method if there is one. These details help determine whether the ultrasonic or rotor-stator mechanism is appropriate and which tool should be evaluated.

For Sonics, specify the probe tip diameter and expected sample-volume range. The standard 6 mm tip is listed for 10–50 mL on the VCX-130-110 page; other probes support different volumes. For IKA, specify the T 25 dispersing tool included in the Solution or request an alternate tool only after compatibility is confirmed. For BIOBASE, identify the BH-50P working head by exact model, not merely by its nominal volume. The manufacturer maps head sizes to differing volume and viscosity ranges.

The vessel also matters. Confirm minimum immersion, head clearance, clamp or stand, vessel material and geometry, and whether the batch needs an enclosure or temperature-control arrangement. Do not infer that all listed tools are compatible with every vessel or that a process is validated from the displayed rpm or wattage. Request the current head/probe drawings and instructions for the exact configuration.

What sample, vessel and process information should I check?

Describe the material without exposing sensitive proprietary details: broad matrix, phases, solids, viscosity, temperature range, corrosivity, flammability or biological hazard as appropriate. Ask the lab's safety owner how to handle the sample and whether additional containment or PPE is required. Sonication can produce heat, noise and aerosol or splash risks depending on the sample and vessel; use the instrument manual and the facility's risk assessment to define controls. This is general safety planning, not an operating protocol for a specific material.

Clarify the desired endpoint in measurable terms. For instance, the team may need a repeatable dispersion, a particle-size range or a specified extraction procedure. Have qualified application staff determine whether that target is achievable and how it should be validated. Power, speed and treatment time are settings; they do not independently prove a particular result.

Plan cleaning between samples. Identify which parts contact the material, whether tools are removable, which cleaning agents and methods the manufacturer permits, how they are dried and stored, and whether replacement tools are required. Ask the supplier to include manuals, cleaning instructions, spare parts and any needed stand, clamp or enclosure in the quotation.

Which electrical, cleaning and safety requirements should I specify?

For Sonics VCX 130, specify export voltage and confirm the exact suffix: the cited manufacturer page is for VCX-130-110. For IKA T 25, identify the 220–240 V variant and verify frequency, cable and plug. For BIOBASE BH-50P, confirm the standard 220 V / 50 Hz configuration or any offered alternate supply, and do not assume a transformer is included. Have a qualified facilities or electrical reviewer check the site circuit, outlet and operating conditions against the actual nameplate and manual.

Include the correct probe or head, stand, clamp, sound enclosure and other requested accessories as explicit quote lines. Manufacturer pages distinguish included and optional components. Product images may show accessories that are absent from a standard package, so ask for a written packing list and exact part codes.

Review tool cleaning, immersion and maintenance instructions before use. Confirm which components may be disassembled, what temperatures or cleaning agents are permitted and what inspection/replacement schedule applies. Have the facility's laboratory safety team evaluate noise, aerosol, splash, heat and sample hazards for the intended process. No product listing substitutes for those local controls.

What should a homogenizer or sonicator quotation include?

Send Franance the model and quantity, facility city/state, sample volume and viscosity, process objective, vessel type, operating schedule and electrical supply. State whether the request is for Sonics VCX 130, IKA T 25 Solution 0010015162 or BIOBASE BH-50P. Include the exact probe or dispersing head and any stand, clamp, enclosure, temperature-control equipment, cable, printer or spare tool needed.

Ask Franance to state the full model suffix, voltage/frequency, included motor and tool, accessory part numbers, applicable sample range, instructions, cleaning information and warranty terms. For Sonics, identify whether the standard probe is included and whether the stand is separate. For IKA, confirm the S 25 EC-C-25 G tool, R 1826 stand and R 182 clamp in the quoted Solution package. For BIOBASE, specify the selected BH-50P work head and its documented range.

Request a written breakdown of delivery, lead time, support, training, installation and any application assistance. These terms depend on the actual quotation and are not asserted by this guide. Franance follows up on the quote request by phone or email; there is no online payment.

Where can I request laboratory homogenizers and sonicators in Nigeria?

Compare the three current models in the homogenizers and sonicators category, or open a filtered listing for Sonics VCX 130, IKA T 25 Solution 0010015162 or BIOBASE BH-50P. Use the wider life-science catalogue to browse related research equipment.

When you request a quotation, give the sample details, method, volume, tool, voltage, accessories, quantity and facility location. Ask for the exact equipment and included components to be identified in writing. Franance will contact you to clarify the request and quote terms; no online checkout is available.

Common questions

What is the difference between a sonicator and a homogenizer?

The Sonics VCX 130 is an ultrasonic processor. The IKA T 25 and BIOBASE BH-50P are rotor-stator dispersers/homogenizers. They use different tools and mechanisms, so select by the application and sample rather than treating them as equivalents.

What volume can the Sonics VCX 130 process?

Sonics specifies the included 6 mm probe for 10–50 mL volumes on the VCX-130-110 page. Other probes and accessories have their own ranges; actual use is application-specific. Confirm the probe and voltage in the quote.

Does the IKA T 25 Solution include a stand and dispersing tool?

IKA identifies the 0010015162 Solution package with a dispersing tool, stand and clamp. Confirm the exact package and 220–240 V variant offered.

Does BIOBASE BH-50P work with every sample volume?

No. BIOBASE lists different working heads for different processing volumes and viscosities. Specify the sample and ask Franance to identify the exact selected head and its current manufacturer range.

Can I order these instruments online in Nigeria?

Franance accepts quote requests and follows up by phone or email; there is no online payment. Include model, voltage, tool/probe, sample details, accessories, quantity and facility location.

Request a laboratory homogenizer or sonicator quotation from Franance.

Send the model, sample volume and viscosity, processing objective, probe or head, electrical supply, stand or enclosure, cleaning needs, quantity and facility location. Ask for the exact included tool and configuration to be itemized. Franance will follow up by phone or email.

Request a homogenizer or sonicator quotation

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart