Buy DNA/RNA Sequencers in Nigeria.

Buy DNA and RNA sequencing systems in Nigeria through Franance by matching the platform to your research workflow, sample volumes, preparation method and data plan. The current category lists Thermo Fisher Ion Torrent Genexus Integrated Sequencer A45727 and Ion GeneStudio S5 Prime System A38196. Request a quote for the exact configuration and supporting equipment; these research-use NGS platforms are not PCR/qPCR instruments or a guarantee of a validated diagnostic workflow.

Products

2 models

Filter all 2 products

Where can I buy DNA and RNA sequencers in Nigeria?

Browse the DNA and RNA sequencer category to compare the two currently assigned catalogue records. Use the Genexus A45727 filtered listing and GeneStudio S5 Prime A38196 filtered listing to isolate the exact model. Their product records are available for Genexus Integrated Sequencer and Ion GeneStudio S5 Prime System.

Read more

What does a DNA or RNA sequencer do?

DNA sequencing determines the order of nucleotide bases in DNA. Sequencing an RNA workflow generally includes converting RNA into complementary DNA (cDNA) before sequencing; exact preparation depends on the assay and platform. An NGS instrument reads sequence data from prepared libraries, then instrument software or other analysis tools process the resulting data. NHGRI explains the distinction between DNA sequencing and PCR: PCR amplifies selected target regions, while sequencing determines the base order in DNA molecules.

Read more

Which sequencing systems are listed?

Franance assigns exactly two records to life-science/dna-rna-sequencers, both branded Thermo Fisher. The Genexus Integrated Sequencer A45727 listing is described by Thermo Fisher as an integrated Ion Torrent NGS instrument. The manufacturer’s product page describes automated targeted NGS starting from purified and quantified nucleic acid, including library preparation, template preparation, sequencing, primary analysis and variant reporting within the Genexus workflow. The official page says it is for Research Use Only and not for use in diagnostic procedures. Confirm the assay packages, compatible consumables, software version and workflow scope applicable to the exact quote.

Read more

Buy DNA and RNA sequencers in Nigeria

Buy DNA and RNA sequencing systems in Nigeria through Franance by first matching the platform to your research workflow, sample volume, sequencing applications, preparation method, data analysis and support requirements. The current Franance category lists two Thermo Fisher Ion Torrent systems: the Genexus Integrated Sequencer (A45727) and the Ion GeneStudio S5 Prime System (A38196). They represent different workflow architectures and must be quoted as their exact catalogue configurations. They are next-generation sequencing (NGS) platforms, not PCR/qPCR instruments, assay kits or complete guarantees of a validated laboratory workflow.

Where can I buy DNA and RNA sequencers in Nigeria?

Browse the DNA and RNA sequencer category to compare the two currently assigned catalogue records. Use the Genexus A45727 filtered listing and GeneStudio S5 Prime A38196 filtered listing to isolate the exact model. Their product records are available for Genexus Integrated Sequencer and Ion GeneStudio S5 Prime System.

Franance accepts a quote order and follows up by phone or email; there is no online checkout. Share the exact catalogue number, intended research workflow, projected sample volume, preparation and analysis plan, site requirements, quantity and delivery destination in Nigeria. The category is a curated catalogue view, not a claim that it lists every sequencer available in the market or that either configuration is stocked locally.

What does a DNA or RNA sequencer do?

DNA sequencing determines the order of nucleotide bases in DNA. Sequencing an RNA workflow generally includes converting RNA into complementary DNA (cDNA) before sequencing; exact preparation depends on the assay and platform. An NGS instrument reads sequence data from prepared libraries, then instrument software or other analysis tools process the resulting data. NHGRI explains the distinction between DNA sequencing and PCR: PCR amplifies selected target regions, while sequencing determines the base order in DNA molecules.

These systems may support workflows that include amplification, but the presence of PCR in a library-preparation protocol does not turn the sequencer into a qPCR thermocycler. A sequencer does not automatically include nucleic-acid extraction, every primer/panel, library-preparation reagents, quality-control instruments, interpretation tools or downstream laboratory information system (LIS/LIMS) integration. Confirm every workflow step and component that is required for your method.

Which sequencing systems are listed?

Franance assigns exactly two records to life-science/dna-rna-sequencers, both branded Thermo Fisher. The Genexus Integrated Sequencer A45727 listing is described by Thermo Fisher as an integrated Ion Torrent NGS instrument. The manufacturer’s product page describes automated targeted NGS starting from purified and quantified nucleic acid, including library preparation, template preparation, sequencing, primary analysis and variant reporting within the Genexus workflow. The official page says it is for Research Use Only and not for use in diagnostic procedures. Confirm the assay packages, compatible consumables, software version and workflow scope applicable to the exact quote.

The Ion GeneStudio S5 Prime System A38196 listing is presented by Thermo Fisher as a semiconductor-based NGS system for targeted sequencing applications. Its product page identifies catalogue A38196 as “System only.” Manufacturer materials describe use with compatible Ion 5 Series chips and a modular workflow that may combine the sequencer with an Ion Chef system for library preparation, template preparation and chip loading. The S5 Prime user documentation also identifies a separate Ion Torrent Server requirement for that configuration. Treat the instrument, server, Chef system, installation kit, chips, reagents and analysis software as distinct scope items unless the supplier confirms a bundle in writing.

The two models differ in workflow integration and equipment scope. Do not assume that the S5 Prime “system only” listing contains the preparation automation or server, or that Genexus’ integrated workflow includes every assay, accessory and support item your lab needs. Review the exact product records and manufacturer documents before comparing costs or throughput.

How do Genexus and GeneStudio S5 Prime differ?

Genexus is positioned by Thermo Fisher as an integrated workflow. Its product documentation describes automation from library preparation through sequencing and primary analysis/reporting, beginning with purified and quantified nucleic acid. The manufacturer’s quick reference and user guide document supported run workflows and setup. The degree of automation does not remove the need to choose an assay, prepare suitable input material, follow the protocol, manage consumables, assess run quality and review data outputs.

GeneStudio S5 Prime is a modular sequencing system. Thermo Fisher describes it as a high-throughput targeted NGS platform, and the manufacturer lists the A38196 catalogue offer as system only. The Ion Chef is a separately identified instrument used in workflows that automate library preparation or template preparation and chip loading; the GeneStudio S5 Prime site-preparation guide also lists a separate Ion Torrent Server as required for the Prime sequencer. Determine which steps your lab will perform manually, which automation units are already present, and what must be purchased or configured alongside the sequencer.

Use the manufacturer’s Genexus product page and GeneStudio S5 Prime product page to check current descriptions and downloadable documents. Do not compare their headline workflow claims without a like-for-like application, sample input, assay, chip, analysis and total equipment boundary.

How is sequencing different from PCR and qPCR?

PCR (polymerase chain reaction) amplifies selected DNA regions; quantitative PCR monitors amplification-associated signal during a run. Sequencing instead produces data that represent the base sequence of prepared DNA molecules. Some targeted NGS library workflows use multiplex PCR to prepare libraries, so PCR may be one upstream preparation step. The sequencer then performs the sequencing run using its compatible chips and reagents.

If your need is only amplification or real-time quantification, compare a suitable thermal cycler or qPCR instrument in the PCR/NAAT platform category. If your research question requires sequence-level information, specify the genomic regions, RNA/DNA material, assay and analysis output before considering an NGS instrument. A PCR instrument, sequencing platform, genotyping assay, microarray and sequencing reagent kit solve different parts of a laboratory workflow and should not be treated as interchangeable product categories.

What applications and assays should I confirm?

Start with the scientific or research question, sample types, DNA/RNA input, target scope, expected sample count, sequencing depth or output requirements, and how results will be analyzed. Thermo Fisher’s materials describe the GeneStudio S5 Prime for targeted sequencing and describe supported application areas; Genexus material describes targeted NGS workflows for DNA, RNA and cell-free total nucleic acid applications. These statements do not establish that a particular panel, sample type, variant class or downstream interpretation is included with a catalogue instrument.

Make a compatibility matrix before requesting a quote. List each intended assay or library kit, required sample input, target regions, chemistry, chip, run setup, analysis package, controls and data file outputs. Ask the manufacturer or supplier to confirm that the exact assay version and instrument/software combination is supported. Keep diagnostic use and research use separate: both product pages label the systems “For Research Use Only. Not for use in diagnostic procedures.” A research application example does not demonstrate regulatory clearance, clinical validation or authorization for a diagnostic service in Nigeria.

Assay kits and panels are separate line items unless the exact order quotation names them. The existence of an assay menu elsewhere in a manufacturer catalogue does not guarantee local availability, compatibility with the quoted system version, or inclusion in this listing.

What sample preparation and workflow equipment may be needed?

Map the full path from sample receipt to data review: extraction, quantification and quality assessment; library preparation; template preparation or amplification; chip loading; sequencing; primary analysis; data storage; and downstream interpretation. Identify which steps the instrument performs and which require separate equipment, staff, kits or software. The Genexus workflow starts from purified and quantified nucleic acid according to manufacturer materials, so do not assume it extracts nucleic acid directly from raw specimens.

For GeneStudio S5 Prime, ask whether the quote includes or excludes an Ion Chef, Ion Torrent Server, installation kit, chip-loading tools, sequencing chips, starter reagents, controls, workstation/server setup and software. Confirm exact compatible chip sizes and assay workflows with current manufacturer documentation. Some options may be available for an S5 family generally but not for every A38196 package, software version or intended protocol.

List existing laboratory infrastructure and staff capability. A platform may require upstream PCR or library-preparation equipment, cold storage for reagents, contamination-control workflows, reliable data storage and trained operators. These are planning questions, not claims that a specific accessory is included. Request an itemized bill of materials that distinguishes the sequencer from preparation instruments, reagents, controls, service and software.

What data, software and connectivity should I plan for?

Ask which software version, analysis modules, server, storage capacity, compute resources, licences and data formats are included with the exact quoted system. Clarify whether analysis is local, hosted or requires a separate server, and how the lab will handle backups, retention, access control, updates and data transfer. For GeneStudio S5 Prime, Thermo Fisher’s configuration materials identify a separate Ion Torrent Server; the user should confirm the exact offered server and its current storage, network and software configuration. Genexus documentation describes software integrated into its workflow, but the lab should still confirm data export, reports and interfaces needed for its downstream process.

Document network policies before installation: permitted internet access, firewall rules, outbound connections, DNS and time services, user accounts, cybersecurity review and any vendor remote-support path. Ask the manufacturer to provide its current IT requirements and security documentation. Do not assume cloud connectivity, LIMS integration, security certifications or compatibility with a particular hospital information system based only on general marketing statements. If an interface is critical, test it with the exact workflow and obtain acceptance criteria in writing.

What site, electrical and service requirements should I check?

Use the exact site-preparation guide, not a generic benchtop-instrument assumption. Thermo Fisher’s GeneStudio S5 site guide lists the S5 Prime sequencer dimensions and weight, calls for a level bench able to support the equipment, and identifies the separate server requirement. Its product specification materials list power and environmental operating conditions for the S5 Prime. Confirm the current values in the latest guide, then have facility engineering verify the bench, circuit, grounding, cooling/ventilation, room conditions, access route and clearances before purchase.

For the Genexus, request the current site-preparation guide and installation requirements for catalogue A45727. Confirm equipment footprint with doors and service panels open, floor or bench loading, room temperature and humidity, electrical supply, network ports, ventilation, delivery access and commissioning scope. Do not extrapolate the S5 Prime site requirements to Genexus; these are distinct instruments and system configurations.

In Nigeria, include the delivery city and state and ask the supplier to confirm the correct voltage/frequency variant, power cord and earthing arrangement, any recommended power conditioning or UPS requirements, shipping and customs responsibilities, installation, qualification, training and local service contact. Ask about warranty start date, response process, spare parts, software support and preventative maintenance in the quotation. The catalogue entries do not confirm local stock, lead time, warranty or service coverage.

What should a DNA/RNA sequencer quotation include in Nigeria?

Send Franance the model and catalogue number—Genexus A45727 or GeneStudio S5 Prime A38196—plus the application, sample types, typical and peak samples per week, DNA/RNA input and intended assays. State whether this is a new sequencing service or an expansion, which preparation instruments and servers you already own, and whether you need a fully itemized workflow. Include existing software and network constraints, data retention expectations, room details, destination, quantity and preferred installation window.

Ask the written quote to identify the exact instrument configuration and all included/excluded equipment: server, Ion Chef or other preparation equipment, installation kit, chips, reagents, controls, software, licences, data storage, installation, qualification, training and service. Confirm the supported assay and chip combination, current instrument/software versions, power/site requirements, consumable storage conditions and delivery scope with manufacturer documentation. If sequencing results are for clinical care, pause and consult the institution’s regulatory and quality leads; these catalogue systems are labelled for research use and not diagnostic procedures.

How do I place a sequencer quote order?

Review the Genexus A45727 listing or the GeneStudio S5 Prime A38196 listing, then send Franance your model choice, workflow, sample volume, assay and chip needs, preparation/server scope, data and IT requirements, site conditions, quantity and Nigerian destination through a sequencer quotation request. Franance will follow up by phone or email to clarify the quote order; there is no online checkout.

Manufacturer sources and scope limits

Manufacturer statements in this guide are based on Thermo Fisher’s Genexus A45727 product page, Genexus Integrated Sequencer User Guide, Genexus quick reference, GeneStudio S5 Prime A38196 product page, Ion GeneStudio S5 Instrument User Guide, Ion GeneStudio S5 System Site Preparation Guide, and NHGRI’s DNA sequencing glossary and genetics glossary entry on PCR and NGS.

Catalogue configurations, consumables, software and manuals can change. This guide does not establish a complete assay menu, validated performance for a specific method, diagnostic authorization, compatibility with a particular sample, local availability, price, lead time, warranty or Nigerian service coverage. Verify all technical, regulatory, data and commercial requirements with the manufacturer, supplier and responsible laboratory professionals before placing an order.

Common questions

Are the listed sequencers qPCR instruments?

No. These are NGS sequencing platforms. PCR may be used in an upstream assay or library-preparation protocol, but amplification and sequence determination are different laboratory functions.

Does the GeneStudio S5 Prime A38196 quote include an Ion Chef or server?

The current manufacturer product page identifies A38196 as system only, and the site guide identifies a separate Ion Torrent Server requirement. Ask the supplier to itemize the server, preparation automation, installation kit, chips, reagents, software and services.

Can these systems be used for clinical diagnostics in Nigeria?

Manufacturer product pages label these systems For Research Use Only and not for use in diagnostic procedures. This guide does not claim diagnostic authorization or validation. Consult the institution's quality and regulatory leads and confirm current local requirements.

Request a DNA or RNA sequencer quotation in Nigeria.

Tell Franance whether you need Genexus A45727 or GeneStudio S5 Prime A38196, your research assays and sample volume, preparation/server scope, data and IT needs, site conditions, quantity and delivery destination. Ask for a written itemization of equipment, consumables, software, installation, training and service.

Request a sequencer quote

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart