Buy Cell Culture Equipment in Nigeria.

Buy cell culture equipment in Nigeria through Franance. Compare CO2 incubators and incubator shakers by workflow, vessel capacity, controls, electrical configuration and required accessories, then request an itemised quotation.

Products

16 models

Filter all 16 products

Where can I buy cell culture equipment in Nigeria?

Send Franance the equipment schedule, intended workflow, requested models or acceptable alternatives, quantity and delivery location. The cell culture equipment listing shows products assigned to this category. It currently includes the Thermo Scientific Heracell VIOS 160i CO2 incubator, PHCbi Cell-IQ MCO-170AICUVHL-PE CO2 incubator, and Eppendorf Innova S44i refrigerated incubator shaker. Follow the CO2 incubator category when the requirement is specifically a controlled-CO2 chamber, or review the Eppendorf cell-culture equipment listing for its brand-filtered range.

Read more

Which cell culture equipment should I buy in Nigeria?

Choose by the controlled process, not by a broad equipment label. A CO2 incubator is intended for chamber-based incubation with documented temperature and carbon-dioxide control. An incubator shaker adds orbital movement for vessels such as flasks and can have refrigerated or non-refrigerated configurations. The culture protocol determines which role is required; the product title alone does not.

Read more

What capacity and vessel format should I specify?

For incubators, state the usable chamber volume, number and arrangement of shelves, vessel sizes, loading pattern and whether a single or multiple chamber arrangement is needed. For shakers, specify flask or vessel types, platform, clamps or holders, working volume, load and required throughput. A nominal litre capacity does not by itself describe the number of cultures a configuration can accommodate.

Read more

Buy Cell Culture Equipment in Nigeria: CO2 Incubators and Incubator Shakers

Buy cell culture equipment in Nigeria through Franance by matching the instrument to the culture workflow, then request an itemised quotation with the exact model, configuration, quantity and destination. The current catalogue for this category includes CO2 incubators from Thermo Scientific and PHCbi, plus an Eppendorf incubator shaker. These instruments support different culture environments: a CO2 incubator controls a chamber environment, while an incubator shaker combines temperature control with agitation. They should not be treated as interchangeable. Start with the laboratory's approved protocol and a written equipment specification. Confirm vessel format, capacity, control requirements, site services and acceptance documents before selecting a model. Franance can review the schedule and prepare a quotation; availability, included accessories, delivery timing, installation and service scope must be confirmed for the actual order.

Where can I buy cell culture equipment in Nigeria?

Send Franance the equipment schedule, intended workflow, requested models or acceptable alternatives, quantity and delivery location. The cell culture equipment listing shows products assigned to this category. It currently includes the Thermo Scientific Heracell VIOS 160i CO2 incubator, PHCbi Cell-IQ MCO-170AICUVHL-PE CO2 incubator, and Eppendorf Innova S44i refrigerated incubator shaker. Follow the CO2 incubator category when the requirement is specifically a controlled-CO2 chamber, or review the Eppendorf cell-culture equipment listing for its brand-filtered range.

For an efficient quote, include the exact catalogue number wherever known. If the protocol is fixed, identify which specifications are mandatory and whether technically reviewed alternatives may be proposed. If the laboratory is still choosing a model, state that this is a selection enquiry and provide the culture type, vessels, batch size, required controls and site constraints. That gives Franance a clear basis for discussing the right equipment class instead of assuming that every “cell culture” request needs the same instrument.

The current listing is a starting point, not a claim that it contains every cell-culture instrument sold in Nigeria. A manufacturer’s regional product page also does not prove local stock, delivery date, authorised-distributor status or the configuration that can be supplied. Ask for the proposed model identity, commercial scope and delivery terms in writing before placing an order.

Which cell culture equipment should I buy in Nigeria?

Choose by the controlled process, not by a broad equipment label. A CO2 incubator is intended for chamber-based incubation with documented temperature and carbon-dioxide control. An incubator shaker adds orbital movement for vessels such as flasks and can have refrigerated or non-refrigerated configurations. The culture protocol determines which role is required; the product title alone does not.

If your procedure requires a stationary humidified chamber and defined gas control, compare CO2 incubators. If it requires agitated liquid cultures in compatible vessels, compare incubator shakers. Some research programmes need both. Do not assume a CO2 incubator can replace a shaker, or that a shaker provides CO2 control, because their equipment functions differ.

The listed models illustrate those distinctions. Thermo Scientific Heracell VIOS 160i is a 165 L CO2 incubator family with different chamber and sensor configurations described by the manufacturer. The PHCbi Cell-IQ MCO-170AICUVHL-PE is a 165 L CO2-incubator reference with a specific electrical suffix and options that must be checked against the offered configuration. Eppendorf Innova S44i S44I310002 is recorded as a refrigerated incubator shaker; the product record identifies its 2.5 cm orbit and UK-catalogue electrical reference, which must be reconfirmed for an order. Compare the exact variants on the category-filtered product list and review the manufacturers’ cited specifications.

What capacity and vessel format should I specify?

For incubators, state the usable chamber volume, number and arrangement of shelves, vessel sizes, loading pattern and whether a single or multiple chamber arrangement is needed. For shakers, specify flask or vessel types, platform, clamps or holders, working volume, load and required throughput. A nominal litre capacity does not by itself describe the number of cultures a configuration can accommodate.

Ask the technical team to compare the intended vessel dimensions with the proposed chamber or platform. For a shaker, the platform and vessel-holding components may be selected separately; list them as quote lines and confirm their compatibility. If the workflow may expand, describe the projected load and available room so the proposal can distinguish an appropriate capacity from an assumed one.

The Heracell VIOS 160i brochure lists 165 L chamber volume. PHCbi’s MCO-170 family data sheet lists 165 L and chamber dimensions for its documented range. Eppendorf’s S44i product page describes a stackable shaker family with platform-dependent capacity. These are manufacturer specifications for named products, not a universal capacity recommendation. Confirm the exact order number, configuration, loading and accessories in the quotation.

What capacity and vessel format should I specify? — review checklist
Equipment in the current catalogueRole to verify in the enquiry
Thermo Scientific Heracell VIOS 160i165 L CO2 incubator range; specify chamber, sensor and exact version
PHCbi Cell-IQ MCO-170AICUVHL-PE165 L CO2 incubator reference; verify suffix, options and power
Eppendorf Innova S44i S44I310002Refrigerated incubator shaker; verify platform, vessel load and current electrical identity

Do I need a CO2 incubator or an incubator shaker?

Use the approved protocol to decide whether the required environment is a stationary chamber, an agitated vessel, or both. For a CO2 incubator, define the gas-control requirement, chamber environment, vessel layout, monitoring and access pattern. For an incubator shaker, define temperature, agitation, orbit, platform and loading. A request that simply says “cell culture incubator” leaves important equipment functions unresolved.

The PHCbi reference in the current catalogue is the MCO-170AICUVHL-PE variant. The model family documentation distinguishes versions and options, including electrical suffixes and available accessories; it does not mean every option is included in that reference. The manufacturer’s data sheet gives the documented range’s temperature control as ambient plus 5°C to 50°C and CO2 setting as 0–20%, under stated conditions. Review the cited data sheet for its test conditions and limitations, and verify current specifications for the actual offered version.

The Heracell VIOS 160i brochure likewise describes multiple chamber-material and sensor configurations. If you need oxygen control, a particular sensor, a specific inner chamber, or a data interface, state it separately and ask for the exact catalogue number. Do not infer an included feature from a product-family name. For the shaker, specify whether refrigeration is necessary and whether the required orbit and vessel platform match the particular reference under review.

Which temperature, gas and agitation specifications matter?

For a CO2 incubator, provide the protocol’s operating temperature and allowed range, CO2 control requirement, any additional gas requirement, humidity expectations and alarm or monitoring needs. For a shaker, state temperature range, whether cooling is needed, speed and orbit requirements, continuous or programmed operation, and any remote monitoring or data-export needs. The responsible laboratory team should approve the performance requirements.

Manufacturer figures must be read with their conditions. PHCbi notes ambient-temperature boundaries and says performance may not be optimal below a stated ambient condition; its published performance data uses specified test setups. Thermo’s brochure supplies model-family dimensions and configuration information. Eppendorf describes S44i orbit options of 2.5 cm and 5.1 cm across its range, while the local catalogue record for S44I310002 identifies 2.5 cm. Do not transfer a range-level choice to an individual order number without confirmation.

If a process has tight control limits, ask the supplier to identify the exact model and documented performance relevant to that limit. Keep required verification, mapping, qualification or calibration as an explicit request. Do not assume a certificate, installation qualification, operational qualification or performance result is included unless the quotation states the scope and responsible party.

What power and site requirements should I check in Nigeria?

Before requesting a final configuration, share the laboratory’s verified supply details, socket or connection requirements, available circuits, backup-power arrangement and installation location. Ask for the exact unit nameplate rating and plug or connection details for the offered version. Equipment in an international brochure may have several voltage and frequency variants, and the model family name may not identify the electrical version.

This is particularly important when comparing the three listed references. The PHCbi suffix “PE” is associated with a 220–240 V, 50 Hz version in its cited data sheet, but the exact proposed nameplate and complete model code still need confirmation. The Eppendorf catalogue record for S44I310002 cites 230 V, 50/60 Hz, which should be checked against the current manufacturer order documentation. Thermo’s brochure covers configurations; confirm the actual electrical identity of the offered Heracell unit. None of these statements establishes local availability or automatic compatibility with a particular laboratory installation.

Also check room access, door width, lift dimensions, floor area, ventilation clearances and service access. A nominal external dimension is not the same as a packed-shipment dimension or a confirmed fit through a site route. Share photographs or measurements when the installation space is constrained and request a written site-readiness review.

Which chamber, sensor and decontamination options should I request?

List each option as a requirement to review, not as an assumed included feature. For a CO2 incubator, state the preferred interior material, sensor type, UV or other decontamination requirement, inner-door arrangement, access port, alarm contacts, data logging and communication interfaces. Ask the quotation to identify the selected option codes, quantities and any supporting consumables or installation parts.

The Heracell VIOS 160i brochure describes electropolished stainless-steel or solid-copper chamber configurations and sensor choices within the family. PHCbi’s MCO-170 family data sheet lists UV and H2O2-related options as separate accessories and describes configuration-specific combinations. A model suffix or family brochure does not establish that every option appears on the catalogue record being quoted. The laboratory should evaluate suitability under its validated cleaning and biosafety procedures; this buying guide does not prescribe a decontamination method.

For incubator shakers, specify the control and data functions, stacking arrangement, lighting if required by the research protocol, and the exact platform accessories. Eppendorf lists monitoring and accessories for its S44i range; confirm which functions and components are supplied with the quoted order number. Ask that optional accessories not be silently folded into the base-unit description.

What should a cell culture equipment quotation include?

Request an itemised proposal with manufacturer, model, full order number, selected configuration and quantity for every instrument. Separate accessories, platforms, shelves, gas regulators, monitoring interfaces, stacking parts and other options into identifiable lines. Include the requested delivery address and timeline for review, but treat dates as confirmed only when Franance agrees them for the order.

Ask for the applicable technical data sheet, operating documentation, electrical details, warranty terms and any calibration or qualification documents relevant to your procurement. If the facility requires installation, training, maintenance or acceptance testing, state the scope and location and request a separate written response. Product-family marketing descriptions do not define what is included in a Nigerian quotation.

For a multi-instrument project, ask the laboratory and procurement teams to approve the equipment schedule before order placement. Compare like for like: chamber capacity, gas controls, sensor, inner material, vessel configuration, platform, electrical version, options, documentation and support. If a proposed alternative changes one of these, make that difference visible so the laboratory can approve or decline it.

How much does cell culture equipment cost in Nigeria?

The catalogue uses quotation-based pricing for these instruments. The final figure depends on the exact model and configuration, accessories, number of units, delivery destination and any separately requested services. Do not compare one base model against another unit with extra sensors, platforms, installation or qualification included unless the quote identifies those components.

To obtain a useful estimate, send Franance the equipment schedule, acceptable alternatives, quantities, site details and required commercial documents. Ask the quotation to separate unit price, accessories, freight or delivery charges where applicable, taxes and services, and to state its validity period and payment terms. These must be confirmed on the actual offer; no fixed price or current stock is implied here.

Can Franance deliver cell culture equipment across Nigeria?

Provide the receiving city and state, facility name, contact person, access constraints and preferred delivery window when requesting a quotation. Franance can review delivery requirements for destinations across Nigeria, but the route, cost, packaging, handling and timing depend on the equipment and order. Confirm the agreed arrangement in the quotation rather than assuming that a general national-coverage statement settles every shipment detail.

For larger incubators and shakers, state whether delivery must include positioning, unpacking, installation or connection to site utilities. Identify any security, access or scheduling requirements for the receiving facility. If special handling or temperature-sensitive accessories are part of the order, list them separately so the proposed arrangements can be checked for those actual items.

How do I order cell culture equipment from Franance in Nigeria?

Send the instrument type, approved model or required functions, capacity, vessels, temperature and gas requirements, electrical details, options, quantities, documents and delivery location to Franance. The team will review the requested scope and contact you to discuss the quotation. This is a quote order; the website does not take payment for online purchases.

Use the filtered cell culture equipment catalogue to review current assigned models. For CO2-only requirements, browse the CO2 incubator range. You can also start a cell culture equipment quotation and attach your schedule. Ask Franance to confirm the proposed model, accessories, availability, delivery and agreed support in writing before you place the order.

Common questions

Are CO2 incubators and incubator shakers interchangeable?

No. A CO2 incubator provides a controlled chamber environment; an incubator shaker combines temperature control with agitation for compatible vessels. Select from the approved workflow and request the required equipment function.

Can I buy cell culture equipment online from Franance?

No online payment is taken. Browse the catalogue and request a quotation; Franance will contact you about the order. Confirm the proposed model, configuration, price and delivery terms before proceeding.

Does a product-family specification guarantee the exact configuration quoted?

No. Ask Franance to state the complete model or order number, electrical variant, selected options and included accessories in the quotation.

Request your cell culture equipment quotation from Franance.

Send the exact model or required equipment role, vessel schedule, capacity, temperature and gas controls, electrical details, options, quantities and destination in Nigeria. Franance will contact you to review the quotation and confirm the proposed supply scope.

Request a cell culture quote

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart