Upright laboratory CO2 incubator with stainless interior shelves, glass-front door and touchscreen

Confirm the exact product reference and supplied package with your quotation.

PHCbi

Buy PHCbi Cell-IQ MCO-170AICUVHL-PE CO2 Incubator
in Nigeria.

165 L CO2 cell-culture incubator

Request a quotation from Franance for the PHCbi Cell-IQ MCO-170AICUVHL-PE CO2 incubator in Nigeria. Specify the electrical variant, culture conditions, chamber and decontamination options, gas connections, monitoring requirements and installation location for a configuration review.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • Manufacturer-listed 165 L Cell-IQ product family
  • 220–240 V, 50 Hz PE electrical version listed by PHCbi
  • Dual-filter infrared CO2 sensor and 0–20% control range in the manufacturer specification
PHCbi Cell-IQ MCO-170AICUVHL-PE CO2 Incubator specifications
ManufacturerPHCbi
Product familyCell-IQ CO2 incubator
ModelMCO-170AICUVHL-PE
Interior volume165 L
Electrical versionPE: 220–240 V, 50 Hz in the PHCbi data sheet; confirm exact supplied configuration
Temperature rangeAmbient +5°C to +50°C
Temperature uniformity±0.25°C under the manufacturer-stated test conditions
CO2 control0–20% range; dual-filter infrared sensor
External dimensions620 x 730 x 905 mm
ConfigurationConfirm UV, humidity, gas controls, decontamination accessories, plug and monitoring requirements

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

Where can I buy the PHCbi MCO-170AICUVHL-PE in Nigeria?

Use the MCO-170AICUVHL-PE product listing, the PHCbi brand page, and the CO₂ incubator category. The PHCbi-filtered CO₂ incubator listing connects the model to other equipment listed under that brand and category. The catalogue is a request-for-quotation pathway; a listing does not confirm that the exact PE variant is stocked or currently available in Nigeria.

Read more

What is the Cell-IQ MCO-170AICUVHL-PE designed to do?

PHCbi describes the MCO-170AIC family as CO₂ cell-culture incubators. The MCO-170AICUVHL-PE is a 165 L chamber intended to provide controlled temperature, carbon-dioxide concentration and humidified conditions for laboratory culture work. Its exact role should be determined by the validated cell-culture protocol, not by the product name alone. This is a CO₂ incubator model; do not assume it controls oxygen concentration like a dedicated multi-gas incubator.

Read more

How large is the 165 L chamber, and what fits inside?

PHCbi lists 165 L interior volume, internal dimensions of 490 × 523 × 665 mm (width × depth × height), and external dimensions of 620 × 730 × 905 mm. Its product page lists a net weight of about 80 kg. These dimensions help estimate a bench or floor location, but the incubator needs operating and service clearance, and the room must allow safe access to the door, shelves, gas connections and rear access port. Verify the latest drawing and packed dimensions before planning a lift, doorway or laboratory layout.

Read more

Buy PHCbi MCO-170AICUVHL-PE CO2 Incubator in Nigeria

To buy the PHCbi Cell-IQ MCO-170AICUVHL-PE in Nigeria, confirm the PE electrical version, the culture conditions your protocol requires, the H₂O₂ and UV decontamination package, and the CO₂ supply before requesting a quote. PHCbi lists this Cell-IQ configuration in its 165 L MCO-170AIC family. Franance accepts quote orders, not online payment. Send the exact model, site voltage and frequency, intended culture workflow, gas and decontamination needs, quantity and destination; the team will follow up by phone or email. Market availability, price, warranty and local service must be confirmed for the proposed unit.

Where can I buy the PHCbi MCO-170AICUVHL-PE in Nigeria?

Use the MCO-170AICUVHL-PE product listing, the PHCbi brand page, and the CO₂ incubator category. The PHCbi-filtered CO₂ incubator listing connects the model to other equipment listed under that brand and category. The catalogue is a request-for-quotation pathway; a listing does not confirm that the exact PE variant is stocked or currently available in Nigeria.

Send Franance a quote order with the model suffix written in full. This is essential because PHCbi lists different voltage and frequency variants: PE is 220–240 V, 50 Hz in the manufacturer’s data sheet, while PA is 110–120 V, 60 Hz. Include the installation city and state, quantity, required accessories, gas-cylinder and regulator setup, room conditions and the service scope you expect. If procurement needs a delivery deadline, state the target date and request written confirmation instead of assuming a standard lead time.

Where can I buy the PHCbi MCO-170AICUVHL-PE in Nigeria? — review checklist
Quote detailWhat to specify
ModelMCO-170AICUVHL-PE, 165 L; verify suffix and nameplate
Culture processTemperature, CO2 set point, vessels, shelf arrangement and protocol
DecontaminationUV and H2O2 hardware, cycle, reagent and training scope
Utilities220–240 V / 50 Hz, gas source, regulator, pressure and room conditions
HandoverDelivery, installation, qualification, data, warranty and service

What is the Cell-IQ MCO-170AICUVHL-PE designed to do?

PHCbi describes the MCO-170AIC family as CO₂ cell-culture incubators. The MCO-170AICUVHL-PE is a 165 L chamber intended to provide controlled temperature, carbon-dioxide concentration and humidified conditions for laboratory culture work. Its exact role should be determined by the validated cell-culture protocol, not by the product name alone. This is a CO₂ incubator model; do not assume it controls oxygen concentration like a dedicated multi-gas incubator.

PHCbi lists a direct-heat and air-jacket heating system, a dual-infrared CO₂ sensor, a full-colour touchscreen and USB data output for the family. The stated temperature range is approximately 5°C above ambient to 50°C, with the manufacturer’s operating conditions and limits applying. The listed CO₂ control range is 0–20%. Those values are technical specifications under defined conditions; they are not a promise that every culture, vessel, loading pattern or room will achieve the same recovery or uniformity.

The MCO-170AICUVHL family designation includes UV and H₂O₂-related decontamination features in PHCbi’s product materials. Confirm whether the offered MCO-170AICUVHL-PE package includes the full H₂O₂ generator, reagent, consumables and the exact cycle configuration required by your facility. Ask for the itemized model code and accessory list because related Cell-IQ variants and optional communication or monitoring accessories differ.

How large is the 165 L chamber, and what fits inside?

PHCbi lists 165 L interior volume, internal dimensions of 490 × 523 × 665 mm (width × depth × height), and external dimensions of 620 × 730 × 905 mm. Its product page lists a net weight of about 80 kg. These dimensions help estimate a bench or floor location, but the incubator needs operating and service clearance, and the room must allow safe access to the door, shelves, gas connections and rear access port. Verify the latest drawing and packed dimensions before planning a lift, doorway or laboratory layout.

The available space for culture vessels depends on shelf arrangement, vessel height, airflow, access for operators and the process you need to validate. Do not calculate usable capacity by dividing chamber volume by flask volume. Ask the laboratory team to list the actual flask, plate or vessel types, sizes and number of positions per shelf. If users work with multiple vessel heights or large bottles, check door opening, shelf clearance and removal technique before selecting a layout.

PHCbi’s published specification lists four shelves in the family data sheet and shelves of approximately 475 × 450 mm. Confirm whether those shelves and any additional racks are included with the exact PE offer. If stacking brackets, a roller base or special trays are required, request each item by name and confirm the safe operating arrangement with the manufacturer’s current manual. A separate accessory may affect the final footprint, accessibility and commissioning plan.

What temperature, CO₂ and humidity requirements should I compare?

Start with the set points, acceptance limits and recovery requirements in your cell-culture protocol. PHCbi reports a temperature range from 5°C above ambient to 50°C, and a temperature uniformity figure of ±0.25°C under stated test conditions. It lists a CO₂ range from 0 to 20% and variation of ±0.15% under the stated conditions, using a dual-filter infrared sensor. The manufacturer notes that performance specifications are based on internal testing and can change; the data sheet describes the figures as reference data, not a guarantee for every installation.

The manufacturer’s stated test conditions matter when comparing performance. Uniformity and CO₂ variation should not be copied into a validation protocol without checking the source conditions, measurement method, chamber load and local acceptance criteria. If your laboratory needs an IQ/OQ/PQ package or calibration records, list the exact requirement and ask whether the proposed quote includes documentation or only the instrument. Product specification figures do not replace site acceptance testing.

The family specification lists natural-evaporation humidification and humidity at 95% RH ±5% RH under its stated conditions. Confirm how the humidity pan is filled, cleaned and maintained, what water quality PHCbi specifies, and whether the required humidity suits your culture process. If the laboratory’s protocol needs a special humidity set point or a non-standard water approach, obtain confirmation from the manufacturer before placing an order.

What does the PE suffix mean for a Nigerian laboratory?

PHCbi’s data sheet identifies MCO-170AICUVHL-PE as a 220–240 V, 50 Hz version. This model suffix is important for Nigerian facilities that use nominal 220–240 V, 50 Hz supply, but the building’s actual power quality and connection must still be checked. A matching nominal voltage does not automatically confirm plug, circuit, earthing, breaker, startup current or installation compatibility.

Ask a qualified facilities or electrical professional to confirm the socket and circuit, phase, earth, protection, voltage stability and backup-power needs. Share the room voltage and frequency with Franance and request confirmation of the offered item’s nameplate and electrical documentation. Do not assume an adapter or transformer is included. If the site uses a generator, inverter or UPS, ask the manufacturer or qualified installer to review compatibility with the incubator’s actual load and operating cycle.

The datasheet lists a CO₂ gas connection and operating pressure. Confirm the cylinder, regulator, tubing diameter and pressure setting required for the supplied configuration. Identify whether your facility wants a manual reserve cylinder, automatic cylinder changeover, alarm output or remote monitoring; the data sheet describes some accessories and communication interfaces as options. Ask for clear line items and avoid assuming a monitoring port, Ethernet connection or external alarm module is standard.

What decontamination and contamination-control features are included?

PHCbi describes contamination-control features in the Cell-IQ line, including copper-enriched stainless-steel interior surfaces and SafeCell UV. The MCO-170AICUVHL variant is also associated with H₂O₂ vapor decontamination. This does not make the chamber self-cleaning or remove the need for a documented laboratory cleaning process. Operators must follow the current manual for chamber preparation, compatible materials, exposure, aeration and restart steps.

The H₂O₂ decontamination cycle may require specific hardware, reagent and process setup. Ask whether the generator, decontamination board or kit, reagent supply, consumables and user training are part of the quote. Confirm the permitted cycle, time needed before use, safety precautions, materials compatibility and procedure after a cycle with PHCbi documentation. Do not treat the manufacturer’s general statement that a cycle takes under three hours as a guaranteed local turnaround: the cycle duration and return-to-use criteria depend on the specified procedure and system conditions.

SafeCell UV and H₂O₂ features have separate functions and precautions. Request the exact model manual and a list of installed options. If the lab needs audit trails, cleaning records or alarms, specify them as acceptance requirements. Franance can help clarify the package and documentation offered, but the laboratory remains responsible for approved operating procedures and trained staff.

How should a lab plan data, alarms and monitoring?

The manufacturer lists USB data transfer and visual, audible or remote alarm functions across the family specification. It also lists optional communication interfaces, including RS-232C/RS-485 and Ethernet, plus an analogue interface. These features may vary by version or option. Before quoting, decide whether staff need local USB logs, a connection to a building-management system, remote alerts or data collection for a quality system. Ask which parts are standard and which require an option or site integration.

Network and remote monitoring can involve IT security, account access and data-retention decisions. Ask PHCbi and your IT lead to identify the supported arrangement and the data sent outside the local instrument, if any. If internet access is not allowed, specify an offline setup and ask how alarm and temperature records are extracted. Do not treat the product page’s general connectivity statements as proof that a cloud feature is included or approved for your institution.

For acceptance, request an alarm list, user guide, maintenance schedule, temperature and CO₂ records, electrical requirements and the test documents that will accompany the offered unit. If a particular certificate or qualification protocol is needed, name it in the quote request and require written confirmation of inclusion, provider, scope and cost.

What should I confirm before buying this CO₂ incubator in Nigeria?

Ask the quotation to identify the complete MCO-170AICUVHL-PE reference, electrical version, 165 L capacity and installed configuration. Confirm the shelves, UV features, H₂O₂ system, gas regulator, pressure, data ports, alarm options and any additional accessories. Ask that the quote separate equipment, consumables, installation, training, validation support, delivery, warranty and service. This makes it easier to compare the proposed package with a related MCO model without confusing options.

Confirm product availability in Nigeria, delivery date, payment terms, price validity, condition, importer and warranty provider in writing. No current stock, price, local-authorised status or specific service entitlement is established by this catalogue guide. Verify the regulatory path for the exact product and transaction with relevant Nigerian authorities and qualified advisers where applicable. NAFDAC’s medical-device registration guidance is a starting reference for products within its scope; it does not establish that this incubator is registered or that every laboratory equipment import follows the same path.

For delivery, confirm access through gates, corridors, stairs and lifts, as well as unpacking and placement. The unit weighs about 80 kg before packaging according to PHCbi’s product page. Confirm whether the offer includes movement into the laboratory, levelling, setup, basic operation training and performance checks. If it does not, obtain a separate plan so that the equipment is not left in storage or installed without appropriate facility readiness.

What does the PHCbi MCO-170AICUVHL-PE cost in Nigeria?

Franance does not publish an online purchase price for this incubator. Final pricing depends on the exact PE variant, the included H₂O₂ system and reagent, accessories, gas regulator, delivery destination, installation and training. A quote with a different voltage suffix or with fewer accessories is not a like-for-like comparison. Ask the supplier to state the exact model and every included or optional item.

Share your destination city and state, target date, quantity, gas and electrical setup, required monitoring and qualification scope. Ask Franance for a written quotation with price validity, availability, delivery assumptions, warranty, installation, consumables and service exclusions. The team will follow up by phone or email to clarify the quote order. Any price or availability must be confirmed for the actual proposed unit.

How do I request an MCO-170AICUVHL-PE quotation from Franance?

Open the PHCbi MCO-170AICUVHL-PE product page or contact Franance about the Cell-IQ incubator. Include the full suffix, cell-culture protocol, temperature and CO₂ targets, vessel types, H₂O₂ requirements, gas supply, electrical connection, room layout, data needs, quantity and destination city or state.

Franance will follow up by phone or email to clarify the quote order and prepare a written offer. Ask the proposal to confirm the model code, PE voltage and frequency, included decontamination hardware and consumables, accessories, current availability, installation, training, warranty and local service. The PHCbi brand page, CO₂ incubator category and cell-culture equipment category connect this product to its broader equipment silo.

Manufacturer references

- PHCbi Cell-IQ incubator family overview - PHCbi MCO-170AIC family data sheet, including PE electrical variant - NAFDAC medical-device registration guideline

Common questions

What electrical supply is listed for the MCO-170AICUVHL-PE?

PHCbi lists the PE variant at 220–240 V and 50 Hz. Confirm the supplied nameplate, plug and site circuit before ordering.

Does the MCO-170AICUVHL-PE control oxygen?

The listed model is a CO2 incubator. Do not assume oxygen control; specify whether your workflow needs a multi-gas incubator.

Is the H2O2 generator included in every quote?

The family has H2O2-related decontamination features, but confirm the generator, kit, reagent and cycle configuration as written line items.

Request your Cell-IQ MCO-170AICUVHL-PE quotation from Franance.

Request a quotation from Franance for the PHCbi Cell-IQ MCO-170AICUVHL-PE in Nigeria. Include the complete model suffix, culture settings, electrical and gas supply, decontamination options, room details, quantity and destination. Franance will follow up by phone or email to clarify the quote order and confirm the proposed package.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Upright laboratory CO2 incubator with stainless interior shelves, glass-front door and touchscreen

Find equipment.

View cart