Buy Washer-Disinfector in Nigeria.
Buy washer-disinfectors in Nigeria through Franance. The category currently lists Getinge Aquadis 44, Aquadis 56 and S-8668. Match the exact model, door configuration, load, wash cart, utilities, installation and validation responsibilities to the facility before ordering. Washer-disinfection cleans and disinfects; it does not by itself sterilize instruments or establish an endoscope-reprocessing process. Franance follows up by phone or email on quotation requests; there is no online checkout.
Products
19 models


















BK-LW60 Table Top Full-automatic Glassware Washer
Table Top Full-automatic Glassware Washer

Which washer-disinfectors can I buy in Nigeria?
The current category contains three Getinge assignments. The Getinge Aquadis 44 filtered listing covers the 44 model family, which Getinge offers in single-door and double-door configurations. Getinge lists up to four wash levels, eight DIN trays and 201 L effective chamber volume for its published product specification.
Read moreWhat does a washer-disinfector do?
A washer-disinfector uses a programmed mechanical process to clean reusable devices and apply a disinfection stage. The exact processes, load supports and cycle parameters depend on the selected machine, program, accessories, chemistry and load. The CDC describes washer-disinfectors as equipment for cleaning, disinfection and drying solid and hollow instruments and recommends using automatic washers according to the manufacturer’s instructions. Cleaning removes soil; disinfection is a separate process with defined requirements. Neither term should be treated as synonymous with sterilization.
Read moreHow do Aquadis 44, Aquadis 56 and S-8668 differ?
Getinge presents the Aquadis 44 as a medium-capacity washer-disinfector for departments, wards, disinfection rooms and clinics where a smaller footprint may matter. Its product page lists up to four wash levels, up to eight DIN trays and 201 L effective volume. Single-door and double-door versions are available. The actual offered door arrangement, loading equipment and dimensions should be named on the quote.
Read moreBuy Washer-Disinfectors in Nigeria
To buy a washer-disinfector in Nigeria through Franance, match the machine to the instruments and workflow, then confirm the exact model, chamber and door configuration, wash carts, utilities, process documentation and installation scope in a written quotation. The current Franance category assigns three Getinge products: Aquadis 44, Aquadis 56 and S-8668. A washer-disinfector mechanically cleans and performs a disinfection process; it does not, by that name alone, sterilize instruments or replace a steam sterilizer. Flexible endoscopes require a separately designed and validated reprocessing pathway. Franance handles orders as quotation requests and follows up by phone or email. The category has no online checkout and does not confirm stock, price, delivery timing or local service. This guide covers equipment selection and procurement, not a validated process for a particular instrument or patient-care load.
Which washer-disinfectors can I buy in Nigeria?
The current category contains three Getinge assignments. The Getinge Aquadis 44 filtered listing covers the 44 model family, which Getinge offers in single-door and double-door configurations. Getinge lists up to four wash levels, eight DIN trays and 201 L effective chamber volume for its published product specification.
The Getinge Aquadis 56 filtered listing is the family-level 56M/56A record. Getinge describes a manual folding-door 56M and automatic vertical-sliding-door 56A. Its international product page gives capacity up to 12 DIN trays or 10 SPRI II trays and describes single-door or pass-through layouts.
The Getinge S-8668 filtered listing is a double-door model in the Getinge 86-series. Getinge’s product specification distinguishes S-8668 from S-8668T Turbo; the catalogue record names S-8668, so do not assume the Turbo version or its features. Browse the washer-disinfector category for all assigned products.
What does a washer-disinfector do?
A washer-disinfector uses a programmed mechanical process to clean reusable devices and apply a disinfection stage. The exact processes, load supports and cycle parameters depend on the selected machine, program, accessories, chemistry and load. The CDC describes washer-disinfectors as equipment for cleaning, disinfection and drying solid and hollow instruments and recommends using automatic washers according to the manufacturer’s instructions. Cleaning removes soil; disinfection is a separate process with defined requirements. Neither term should be treated as synonymous with sterilization.
The Getinge models listed here are instrument washer-disinfectors. Getinge identifies the 86-series intended loads as including surgical instruments, bowls, basins, glassware, receivers, suction bottles, baby bottles, anaesthesia equipment and other compatible reusable items. That family description does not establish that every item is compatible with every Aquadis or 86-series model, cart or cycle. Check each reusable device’s instructions for reprocessing and confirm the machine and loading accessory are validated for it.
A washer-disinfector is one component of a decontamination workflow. Facilities need defined dirty-to-clean movement, pre-treatment and loading practices, compatible chemistry, unloading, inspection and downstream preparation. The World Health Organization describes reprocessing as sequential steps supported by infrastructure, equipment and quality control, including validation. A machine purchase alone does not create a validated sterile-services process.
How do Aquadis 44, Aquadis 56 and S-8668 differ?
Getinge presents the Aquadis 44 as a medium-capacity washer-disinfector for departments, wards, disinfection rooms and clinics where a smaller footprint may matter. Its product page lists up to four wash levels, up to eight DIN trays and 201 L effective volume. Single-door and double-door versions are available. The actual offered door arrangement, loading equipment and dimensions should be named on the quote.
Aquadis 56 increases the published loading capacity to up to 12 DIN trays or 10 SPRI II trays on the international product page. It is offered as 56M with a manual folding door or 56A with an automatic vertical sliding door, with single-door or pass-through models described. Door operation and pass-through layout affect the room plan, hand-off flow and equipment access. Getinge’s regional product information may show different tray standards or capacity details, so verify the exact market configuration in the proposal.
The Getinge S-8668 belongs to the 86-series and is a larger double-door machine. The product specification gives 351 L effective chamber capacity and up to 18 DIN 1/1 trays for S-8668/S-8668T. The specification explicitly distinguishes non-Turbo S-8668 from Turbo S-8668T. Treat the Franance S-8668 record as the non-Turbo named model unless a quote clearly specifies another product. Do not transfer the Turbo cycle claim, configuration or throughput to S-8668.
Does a washer-disinfector sterilize instruments?
No. A standard washer-disinfector performs mechanical cleaning and a defined disinfection process. It does not automatically make an instrument sterile. CDC recommendations distinguish cleaning, disinfection and sterilization and state that critical instruments entering sterile tissue or the vascular system require sterilization before reuse. The appropriate pathway depends on device classification and manufacturer instructions; healthcare professionals and infection-prevention staff set that pathway.
In a typical instrument reprocessing workflow, compatible devices are cleaned and disinfected, inspected, prepared and packaged, then passed through a separate sterilization process where required. The steam sterilizer is a separate equipment class with its own cycle requirements, monitoring, loading, packaging and validation. A washer-disinfector category page should not be used as a substitute for tabletop steam autoclaves, vertical steam autoclaves or the facility’s sterilization policy.
Getinge’s product specification may list compliance with standards for a specific 86-series document and jurisdiction, but those statements do not prove a particular offered unit’s conformity or the facility’s process validation. Ask for the declaration and technical file applicable to the exact reference and market. The guide does not assert that the three listings are certified to a particular standard, registered in Nigeria or validated for a local load.
Is this category suitable for flexible endoscope reprocessing?
Do not assume so. The three assigned records are Getinge instrument washer-disinfectors; the catalogue does not identify them as automated endoscope reprocessors. Flexible endoscopes are thermolabile and have complex channels, connectors and device-specific reprocessing instructions. ISO 15883-4 addresses washer-disinfectors intended for chemical cleaning and disinfection of thermolabile endoscopes and requires particular performance and validation testing. That scope is distinct from the general thermal-disinfection requirements used for compatible reusable instruments.
The CDC recommends meticulous cleaning before high-level disinfection or sterilization and describes endoscope processing as involving access to internal channels and the applicable device instructions. Do not use an Aquadis or S-8668 cycle for an endoscope unless the endoscope and washer-disinfector manufacturers document and validate that exact method and configuration. If the facility needs endoscope reprocessing, specify scope models, channels, connectors, chemistry, cycle and required documentation, then source an endoscope-reprocessing system designed for that purpose.
This distinction also matters for accessories. A rack or channel connection made for one device does not imply compatibility with another endoscope or instrument. Obtain the manufacturer loading plan and compatibility evidence before including specialised loads in a procurement specification.
How should tray capacity and wash carts guide selection?
Published tray counts are useful for initial room and throughput planning, but they are not a complete capacity forecast. Getinge quotes Aquadis 44 at up to eight DIN trays; Aquadis 56 at up to 12 DIN or 10 SPRI II trays on the cited international page; and the 86-series S-8668 family at up to 18 DIN 1/1 trays. DIN and SPRI tray formats differ, and baskets, racks, injector modules and load geometry determine how many specific items fit and whether the process can contact required surfaces.
List the actual load families: instrument sets, hinged devices, cannulated devices, bowls, glassware or other compatible items. Provide tray dimensions, set weights and expected daily or peak workload. Ask Getinge to propose the compatible wash carts and accessories, identify whether each is included, and supply loading diagrams for representative loads. For hollow or complex devices, verify connector and flushing arrangements against both the device and washer-disinfector instructions.
Avoid choosing a machine solely by the highest tray figure. Door configuration, cycle timing, room bottlenecks, staff handling, clean/dirty separation and downstream packaging can constrain actual throughput. Confirm all assumptions with the CSSD lead, infection-prevention team, clinical engineering and facility planners before approving a configuration.
What utilities and installation requirements should be checked?
Before selecting a model, request its installation planning information and utilities schedule for the exact variant. Confirm required electrical supply and protection, water supply quality and pressure, drainage, any steam or heating services required by the selected configuration, ventilation or heat rejection, floor loading, service clearances and access for delivery. The specific requirements may differ among Aquadis 44, Aquadis 56 and S-8668 variants and by country. This guide does not assume that the site has suitable connections or that installation is included in a quotation.
For a Nigerian project, have the facility’s engineering team measure and document site conditions. Check doorways, lift and route dimensions, ceiling height, floor capacity, room layout, dirty-to-clean workflow and service access. For a pass-through model, agree wall openings, adjacent-room relationships and door interlocks with the project team before construction. Confirm water treatment and detergent compatibility against Getinge’s current specifications and local water analysis rather than assuming the same utilities for every hospital.
Ask the quote to separate equipment, wash carts, chemical dosing or connection systems, water treatment, installation, commissioning, validation support, operator training and service. Have the supplier identify exclusions and prerequisites. Do not assume a machine price includes building works, utility upgrades or validation documentation.
What validation and routine controls should be planned?
ISO 15883-1:2024 sets general performance requirements and test methods for washer-disinfectors intended to clean and disinfect reusable medical devices. It also addresses validation, routine control and monitoring, and requalification after periodic intervals or essential repairs. ISO 15883-2:2024 covers washer-disinfectors employing thermal disinfection for critical and semi-critical medical devices, used together with Part 1’s general requirements. These standards describe technical requirements; mentioning them does not prove certification of an individual machine or compliance at an installation.
Before procurement, ask the manufacturer or supplier which current standards and test reports apply to the exact model, configuration and intended load. Identify installation, operational and performance qualification responsibilities, acceptance criteria, routine tests, record retention, process challenge devices where applicable, maintenance intervals and requalification triggers. Agree who performs each activity, who provides instruments and consumables, and what documentation the facility receives.
Validation is load- and process-specific. A successful cycle display alone does not demonstrate that every instrument was cleaned, compatible or ready for sterilization. Staff must follow the device and washer instructions, approved procedures, chemistry requirements and facility quality system. The facility’s responsible decontamination lead should approve the process before clinical use.
What should a Nigerian washer-disinfector quotation include?
State the required model: Aquadis 44, Aquadis 56 with 56M or 56A option, or Getinge S-8668 (confirm explicitly if S-8668T is proposed). Include single-door or pass-through requirement; expected tray standard and number; representative instrument load types; desired wash carts and injector modules; quantities; room layout; utilities information; and delivery city/state in Nigeria. Name any required chemistry, water treatment or data/traceability interface as a requirement for technical review rather than assuming it is part of the base machine.
Ask for the exact manufacturer reference, current technical specification, dimensions, utilities schedule, installation prerequisites, accessory list, process and cycle documentation, applicable conformity documents, warranty terms and service scope. Request a project survey where appropriate and ask who is responsible for shipment, offloading, positioning, connections, commissioning, validation support, training and routine maintenance. Have Getinge or the quoting team identify every assumption and exclusion in writing.
Franance accepts quote orders rather than online payments. The quotation should state current availability, unit condition, delivery arrangements, quote validity, payment terms and any service commitment being offered. No local stock, authorization, registration, price, delivery date, warranty or service coverage is asserted by this guide; confirm each item for the specific offer.
How do I request a washer-disinfector quote from Franance?
Browse the washer-disinfector category, then open the exact Aquadis 44, Aquadis 56 or S-8668 listing. You can also send Franance a washer-disinfector quote request. Include the planned process, model and variants, load and tray details, site utilities and location so the team can route technical questions before the commercial offer is finalised.
Review the offer with CSSD leadership, infection prevention, biomedical engineering, procurement and facilities. Confirm whether the proposed machine matches the intended devices and the room plan, and agree on acceptance and validation responsibilities before purchase. A successful equipment selection depends on the complete process, not only chamber capacity.
Frequently asked questions about washer-disinfectors in Nigeria
### Which Getinge washer-disinfectors are listed?
The current assigned products are Aquadis 44, Aquadis 56 and S-8668. The Aquadis models have door and configuration choices. The S-8668 listing is distinct from the S-8668T Turbo model.
### Does a washer-disinfector sterilize surgical instruments?
No. It cleans and applies a disinfection process. Instruments requiring sterilization need a separate validated sterilization step according to their intended use, manufacturer instructions and facility policy.
### Can I process flexible endoscopes in the listed machines?
Do not assume that. Endoscopes need a specific validated process and compatible automated endoscope reprocessor. Confirm exact scope and reprocessor compatibility; ISO 15883-4 covers a distinct category of endoscope washer-disinfectors.
### Is the S-8668 listing the Turbo version?
The category record names S-8668. Getinge distinguishes S-8668 from S-8668T, so require the written quotation to identify the exact model and not assume Turbo features.
### Does the listed tray capacity guarantee my load fits?
No. Tray counts depend on tray standard, wash cart and load geometry. Give the supplier representative load diagrams and request the compatible loading accessories and plan.
### Is installation or validation included in the quote?
The catalogue does not say. Ask the written quote to identify survey, utilities, installation, commissioning, validation support, training and maintenance as included or excluded items.
### Can Franance confirm delivery and local service?
Ask for availability, destination-specific delivery and any service scope in the written quote. The product listing does not establish current Nigerian stock or service coverage.
Manufacturer and standards sources
- Getinge Aquadis 44 official product page - Getinge Aquadis 44 official brochure - Getinge Aquadis 56 official product page - Getinge 86-series official product page - Getinge S-8668 product specification - ISO 15883-1:2024 general washer-disinfector requirements - ISO 15883-2:2024 thermal disinfection requirements for critical and semi-critical devices - ISO 15883-4:2018 requirements for thermolabile endoscope reprocessors - CDC summary recommendations for disinfection and sterilization - WHO aide-memoire on medical-device decontamination and reprocessing
Manufacturer pages and standards describe families, versions and general requirements. They do not confirm that a quoted configuration is available in Nigeria, meets local site utilities, is approved for each proposed instrument load, or carries a particular local registration or service arrangement. Confirm the exact machine, accessories, process documentation and commercial terms for the written offer. The facility remains responsible for selecting, validating and monitoring its reprocessing workflow.
Common questions
Which Getinge washer-disinfectors are listed?
The assigned models are Aquadis 44, Aquadis 56 and S-8668. The Aquadis machines have configuration options; Getinge distinguishes S-8668 from S-8668T Turbo.
Does a washer-disinfector sterilize instruments?
No. It performs cleaning and disinfection. Where sterilization is required, that is a separate validated process and equipment step under the facility workflow.
Can the listed machines reprocess flexible endoscopes?
Do not assume so. The catalogue does not identify these Getinge instrument washers as endoscope reprocessors. Confirm the specific endoscope and system instructions and validated process.
Is the listed S-8668 the Turbo model?
The record names S-8668. Getinge distinguishes the S-8668 and S-8668T Turbo; the written quote should identify exactly which is proposed.
Does tray capacity guarantee my instruments will fit?
No. Capacity depends on tray format, loading equipment and load geometry. Provide representative load information and obtain the proposed cart and loading diagram.
Are installation and process validation included?
Not established by the catalogue. Ask the written offer to state survey, utilities, installation, commissioning, validation support, training and maintenance scope.
Does Franance confirm local stock and service?
The listing does not establish these. Ask Franance to confirm availability, destination-specific delivery and any service or warranty scope in writing.
Request a washer-disinfector quotation from Franance.
Send the selected model and door configuration, instrument and tray loads, loading accessories, utilities, installation requirements and Nigerian delivery location. Franance will follow up by phone or email to clarify the quote order.
Request a washer-disinfector quoteNeed an equipment quote?
Add the models you need to a quote order, or send us your equipment list.