Buy ELISA Reader in Nigeria.
Buy ELISA microplate readers in Nigeria through Franance. Compare the Agilent BioTek 800 TS, BIOBASE BK-EL10 series and Mindray MR-96A, then request a quotation for the exact reader configuration, plate and wavelength requirements, software, site needs and assay compatibility review.
Products
9 models
Where can I buy an ELISA reader in Nigeria?
Start at the ELISA reader category and compare the three listed reader records. Use these catalogue filters to jump to each brand and model: Agilent BioTek 800 TS, BIOBASE BK-EL10A series listing, and Mindray MR-96A. Each filter is narrowed by brand, category and model text. The BIOBASE filter leads to a series record covering several variants, so state the required suffix in your enquiry.
Read moreWhich ELISA readers are listed in Nigeria?
The Agilent BioTek 800 TS is an absorbance reader with multiple configuration suffixes. Its base 800TS configuration supports 6- to 96-well plates and a 400–750 nm wavelength range according to Agilent's technical details. Other suffixes can change plate formats or add capabilities such as incubation or UV measurement. Identify the exact suffix rather than comparing the name “800 TS” as if every configuration were identical.
Read moreBuy Agilent BioTek 800 TS in Nigeria
The 800 TS is a configurable absorbance reader for microplate workflows, including ELISA. Agilent's configuration table distinguishes 800TS, 800TSI, 800TSUV, 800TSUVI and 800TSNB. The base configuration and suffix options do not share one universal plate and wavelength capability. Agilent's technical details list 6–96 well plates and 400–750 nm for base 800TS; UV and other suffixes change the available range or format. Confirm the exact combination against the manufacturer's current specification for the proposed part number.
Read moreBuy ELISA absorbance microplate readers in Nigeria
To buy an ELISA reader in Nigeria, first match the reader to the laboratory's documented assay wavelengths, plate format, data workflow and throughput. Franance currently lists the Agilent BioTek 800 TS, the BIOBASE BK-EL10 series and the Mindray MR-96A. These are absorbance microplate readers; the catalogue does not include assay kits or make a reader and washer the same instrument. Send Franance the required configuration and facility destination for a quotation order. The team follows up by phone or email to confirm the offer; this is not online checkout. The selected instrument is only one part of an analytical workflow. The laboratory remains responsible for selecting an appropriate method, consumables, controls, procedures and any required verification or validation. Manufacturer descriptions of product use, including IVD language, do not confirm that a particular assay is authorized or validated for a particular Nigerian laboratory. Ask for current documents that apply to the exact model and configuration being quoted.
Where can I buy an ELISA reader in Nigeria?
Start at the ELISA reader category and compare the three listed reader records. Use these catalogue filters to jump to each brand and model: Agilent BioTek 800 TS, BIOBASE BK-EL10A series listing, and Mindray MR-96A. Each filter is narrowed by brand, category and model text. The BIOBASE filter leads to a series record covering several variants, so state the required suffix in your enquiry.
For direct specifications, open the 800 TS catalogue listing), BIOBASE BK-EL10 series record or MR-96A catalogue listing. Listings describe the catalogue models and give a starting point for configuration discussion. They do not establish current stock, final package contents, price, delivery date or local support terms. Those details should be written into the quotation.
Which ELISA readers are listed in Nigeria?
The Agilent BioTek 800 TS is an absorbance reader with multiple configuration suffixes. Its base 800TS configuration supports 6- to 96-well plates and a 400–750 nm wavelength range according to Agilent's technical details. Other suffixes can change plate formats or add capabilities such as incubation or UV measurement. Identify the exact suffix rather than comparing the name “800 TS” as if every configuration were identical.
The BIOBASE BK-EL10 listing is a family record for BK-EL10A, BK-EL10B, BK-EL10C, BK-EL10D and BK-EL10DA. BIOBASE lists the variants for 96-well microplates and describes differences in wavelength range, filters, display, interface and incubation. The product page also discusses a washer, but the reader and washer are different instruments. Ask for the precise BK-EL10 variant and an itemised list of any separate washer or accessories.
Mindray MR-96A is a microplate reader. Mindray lists a 7.8-inch touchscreen, variable time and speed shaking modes, memory for up to 20,000 results, a built-in thermal printer, RS232 and two USB ports. The manufacturer's computer data-management software is optional. Confirm in writing which software, accessories and support apply to the offered unit.
Buy Agilent BioTek 800 TS in Nigeria
The 800 TS is a configurable absorbance reader for microplate workflows, including ELISA. Agilent's configuration table distinguishes 800TS, 800TSI, 800TSUV, 800TSUVI and 800TSNB. The base configuration and suffix options do not share one universal plate and wavelength capability. Agilent's technical details list 6–96 well plates and 400–750 nm for base 800TS; UV and other suffixes change the available range or format. Confirm the exact combination against the manufacturer's current specification for the proposed part number.
Before requesting a quote, share the plate type and well count used by the laboratory, all required wavelengths, whether single or dual wavelength readings are required by the method, and whether the workflow needs temperature control or shaking. Ask Franance to identify the model suffix, filter set, software, reader control method, computer connection, plate accessories and any installation or qualification service as separate quote lines. Do not infer that a configuration shown in a family brochure is included in the quoted base model.
Agilent calls the 800 TS an IVD reader in its product materials. This label describes the manufacturer's product positioning; it is not confirmation of Nigerian registration, assay authorization, or suitability for a laboratory's specific procedure. The laboratory should check its intended-use requirements and method documentation independently.
Buy BIOBASE BK-EL10 series ELISA reader in Nigeria
The catalogue item represents five BIOBASE variants, so the quote should say BK-EL10A, BK-EL10B, BK-EL10C, BK-EL10D or BK-EL10DA. BIOBASE's page lists eight vertical optical channels and 96-well measurement for the family, but other details depend on the variant. The manufacturer lists 400–750 nm ranges for A/B/C and 340–850 nm ranges for D/DA, with standard filter sets differing by model. Optional filters and other options should be confirmed for the exact proposed suffix.
Display, control and incubation are not uniform across the series. BIOBASE describes a touchscreen for most variants, with BK-EL10B as an exception, and identifies Windows or Android interface differences for the D and DA variants. Incubation is listed for BK-EL10D and BK-EL10DA, not as a universal series feature. Ask the seller to quote the chosen reader's precise interface, language, included software, filter configuration, printer and data export method. If incubation is required, confirm its range and control specifications against the current manual.
BIOBASE's manufacturer page presents both ELISA readers and a microplate washer. Treat a washer as a separate equipment selection with its own model, plate compatibility, wash programme and package. This category and product record concern the reader. They do not imply that a washer, assay kit, reagent, control, microplate or computer is included.
Buy Mindray MR-96A microplate reader in Nigeria
Mindray identifies MR-96A as a microplate reader and describes a 7.8-inch touchscreen, shaking modes with variable time and speed, and storage for up to 20,000 results. Its published feature list includes a built-in thermal printer, one RS232 connection and two USB ports. Computer-installed data-management software is described as optional. Ask the quotation to state the included configuration and the exact software version or package if computer management is part of the requirement.
Prepare a short workflow brief: the number and type of plates, assay read wavelengths, expected daily workload, where the data will be reviewed, and whether the laboratory needs printed results, file export or computer control. Ask whether the printer's consumables, computer, cable, installation, training and software licence are included. Confirm the exact power requirements and operating environment using the applicable manufacturer documentation; do not assume every port supports the transfer or integration method the laboratory wants.
The MR-96A feature list does not validate a method or guarantee compatibility with every ELISA kit. The laboratory should confirm assay requirements with the kit manufacturer and determine whether any method verification, quality controls or local approvals apply.
What does an ELISA microplate reader do?
An absorbance microplate reader measures light absorbance in wells of a microplate at specified wavelengths. Depending on the selected method and configuration, a reader can record readings across multiple wells and return data for analysis. The optical measurement is one step within a broader procedure; the reader does not itself supply the assay reagents, perform every preparation step or establish the meaning of a result.
When comparing instruments, translate the laboratory protocol into a requirement list. Include the assay's specified wavelength or wavelengths, plate type, reading mode, required reference wavelength if any, number of wells per run, timing constraints and reporting needs. The laboratory lead should confirm those requirements against the assay instructions and instrument documentation. A supplier can then identify a proposed model configuration for review, without substituting a different method or making clinical decisions for the user.
Distinguish plate-reader functions from adjacent products. An ELISA washer handles liquid dispensing, aspiration or washing steps when specified by the workflow. Assay kits provide reagents and method-specific instructions. Calibrators, controls, plates, seals and other consumables are separate items unless explicitly listed. If the lab needs an integrated workflow, ask for each component and its compatibility evidence in the quotation.
How do I choose wavelength, filter and plate format in Nigeria?
Use the assay protocol as the source of the required measurement settings. Send Franance the required primary and reference wavelengths, whether single- or dual-wavelength measurement is specified, the plate type and well count, and any throughput constraints. Ask the supplier to confirm that the exact offered reader suffix and supplied filter or wavelength-selection system support those requirements. Record the answer by model and part number rather than relying on a general product-family statement.
Plate formats are not interchangeable by assumption. A system that accepts one format may not support another, and certain Agilent 800 TS suffixes are required for formats beyond the base 6–96 well configuration. The BIOBASE BK-EL10 family is described for 96-well measurement. For any proposed alternative, obtain the manufacturer document identifying the plate format and compatible carrier. Check plate material, clear or opaque wells, volume and geometry against the assay instructions.
The reader's wavelength range does not prove that the required wavelengths or filters are included. Ask for the supplied filter list or wavelength capability, required bandwidth and any additional filters as separate quote details. If the method requires temperature or timed shaking, confirm that the exact model includes those options and that the settings meet the laboratory's protocol. Franance can coordinate the configuration query; the laboratory remains responsible for the method choice.
How is a reader different from a washer and assay kit?
A reader measures the optical signal from the prepared plate. A washer performs liquid-handling or wash actions. A kit supplies reagents and a method; it is not an instrument. These functions may be used in a laboratory workflow, but they are separate purchase items and should be budgeted and specified separately. Mindray's ELISA family page distinguishes the MR-96A reader from the MW-12A washer. BIOBASE's combined product page also includes information about a washer, which does not mean the BK-EL10 reader listing includes one.
For a washer, define plate compatibility, number of wash channels, dispensing and aspiration needs, residual volume requirements if stated by the method, wash buffer handling and waste arrangements. For a kit, identify the manufacturer, catalogue number, intended assay, package size, expiry and storage conditions. For controls or calibrators, request the exact references and quantity. Do not assume a reader brand determines which assays are appropriate or that a reader-and-washer combination has been validated as a complete diagnostic system.
See the separate ELISA washer category for washer equipment. When requesting a combined laboratory quote, ask Franance to separate instrument, software, installation, training, service, consumables and assay items so the facility can evaluate each line independently.
What software, incubation and data features should I define?
List how results must move from the instrument to review, analysis and retention. Specify whether staff will use the reader's own interface, a computer application, USB export, serial connection, printed reports or another method. Identify the desired file type and who will use it. A stated USB or RS232 port alone does not guarantee compatibility with a particular laboratory information system, export format or network. Ask for the exact manufacturer software, supported operating system, licence terms, cables, installation requirements and interface documentation.
For the Agilent 800 TS, confirm software and any incubation or shaking options by configuration. For BIOBASE, confirm the BK-EL10 variant because its interface and incubation features vary. For Mindray MR-96A, computer data-management software is optional, while the manufacturer lists onboard result memory and a thermal printer. In all cases ask which components are supplied and which are optional. Include data backup, user access and record-retention needs in the facility's technical review.
If the method requires controlled incubation, confirm the model-specific temperature range, uniformity or control characteristics from current manufacturer documentation. Do not treat “incubation” as a single standard capability. If shaking is needed, specify duration and speed requirements only as provided by the protocol and verify the available settings for the offered model. The supplier should identify any limitation or optional package before the facility orders.
What does IVD labeling mean for a Nigerian purchase?
Agilent describes the BioTek 800 TS as an IVD product. This does not, by itself, establish that the instrument is registered or cleared for the intended transaction in Nigeria, that a particular assay is locally authorized, or that a laboratory's operating procedure is validated. Product labels and intended-use statements must be read in the context of the exact model, market and applicable rules. Do not infer national authorization from a manufacturer's global product page.
Before purchase for diagnostic work, the facility's regulatory or quality lead should verify the requirements that apply to the instrument, the assay and the intended use. Request the applicable manufacturer declarations, instructions for use, model identifiers, software details and supply documentation. Confirm registration or import requirements with the appropriate Nigerian stakeholders. If equipment is for research, teaching or another non-diagnostic purpose, document that intended use and ask the supplier to confirm the offered product's stated scope.
The reader alone does not prove analytical performance for a test. The laboratory's quality system and assay instructions determine the procedures, controls, acceptance criteria and records required. Franance can provide the quoted product information and coordinate requests to the manufacturer; the end user should review documentation and determine whether the product is appropriate for its regulated workflow.
What should an ELISA reader quotation include?
To receive a useful quotation from Franance, include the exact model or suffix, quantity and full destination in Nigeria, including city and state. Add the plate format, required wavelengths and filters, assay or method context, incubation and shaking needs, software and data-transfer requirements, printer or computer needs, accessories, and any separate washer or consumables. Attach a specification sheet or tender schedule if the facility has mandatory criteria.
Ask the quote to itemize the instrument, included accessories, optional filters, software licences, computer, printer supplies, installation, commissioning, user training, qualification documentation, warranty and service. Request the manufacturer part number and current configuration documents. Ask for power input and installation requirements applicable to the offered unit. State whether delivery is to a laboratory floor or loading bay and identify access restrictions, stairs, lift, receiving hours and a contact person.
Request the commercial details in writing: quoted currency, validity period, payment milestones, delivery estimate, freight and inland transport, import or other charges if applicable, warranty scope, service location, response process and exclusions. None of these terms can be assumed from a product listing. If the facility requires on-site response or preventive maintenance, name the site and requested service interval and obtain a clear statement of what Franance or its service partner can provide.
How do I place an ELISA reader quote order in Nigeria?
Use the product filter that matches the selected reader, or send a specification enquiry through Franance. The team will contact you by phone or email after receiving the request to confirm the model, configuration, quantity, destination and commercial terms. A submitted enquiry is a quotation order; it is not an online payment or an automatic purchase confirmation.
Before approving an offer, check that the model suffix, wavelength/filter set, plate format, software, accessories and services match the requirement list. Have the laboratory user, biomedical engineering, IT and procurement teams review the points relevant to them. Resolve substitutions in writing and ask for current manufacturer documents for the exact offered configuration. Then follow the facility's purchasing process and confirm acceptance, delivery and installation arrangements with Franance.
To start, request an ELISA reader quotation and include your contact details and delivery location. For an individual record, see Agilent BioTek 800 TS), BIOBASE BK-EL10 series and Mindray MR-96A.
Manufacturer sources and configuration limits
Consult the Agilent BioTek 800 TS product page and its technical details PDF for model suffixes, plate formats, wavelength ranges and power requirements. Review the BIOBASE BK-EL10 family page for variant-specific reader and washer details. See Mindray's MR-96A product page and ELISA family page for the reader/washer distinction and listed reader features.
Manufacturer pages and technical sheets may change. Ask Franance to identify the exact product and configuration in its quotation, and compare that offer with current model-specific documentation before purchase. This guide is a procurement overview, not a substitute for assay instructions, laboratory method validation, regulatory review or manufacturer installation guidance.
Common questions
Is an ELISA reader the same as a microplate washer?
No. A reader measures optical signals from a plate; a washer performs liquid handling or washing steps. A laboratory may use both, but they are separate instruments and purchase lines.
Does the reader include ELISA kits and reagents?
Not by default. Identify assay kits, reagents, controls, plates, seals, software and service separately and ask the quotation to state what is included.
Does Agilent's IVD description prove local authorization for an assay in Nigeria?
No. The manufacturer's product description does not establish Nigerian registration or authorize a specific assay or laboratory workflow. Confirm the exact product, assay and local requirements with the appropriate manufacturer and regulatory stakeholders.
Request an ELISA reader quotation in Nigeria.
Send Franance the exact reader model or suffix, plate type, assay wavelengths and filters, software and data requirements, accessories, quantity and destination. Identify any requested installation, qualification or documentation needs so the proposed scope can be itemised.
Request an ELISA reader quoteNeed an equipment quote?