
BioTekBuy Agilent BioTek laboratory microplate instruments
in Nigeria.
Browse Agilent BioTek microplate washers and absorbance readers listed by Franance. Specify the assay workflow, microplate format, reader or washer requirements, software and accessories, then request a quotation for your laboratory.
Buy Agilent BioTek Clinical Laboratory Equipment in Nigeria
Agilent BioTek equipment listed in this department includes the 50 TS Microplate Washer and 800 TS Absorbance Reader. Review the product records and specify the instrument that matches your laboratory assay workflow.
Buy Agilent BioTek Microbiology and Molecular Equipment in Nigeria
View all 2 productsThe Agilent BioTek instruments listed in this family are the 50 TS Microplate Washer and 800 TS Absorbance Reader. Compare their product records by assay workflow and specify the required instrument and microplate setup.
State the exact instrument, assay workflow, plate type and format, wash or absorbance-read needs, software or interface and accessories, quantity and destination. Request an itemised Franance quotation for the specified configuration.
Buy Agilent BioTek ELISA Readers in Nigeria
View 1 productThe listed Agilent BioTek product in this range is the 800 TS Absorbance Reader. Use its product record to identify the model and state the assay, plate and measurement requirements for your laboratory quotation.
Specify the 800 TS reference, assay and plate format, required absorbance measurements, software and interface needs, accessories, quantity and location. Request confirmation of the reader configuration in Franance’s quotation.
Buy Agilent BioTek ELISA Washers in Nigeria
View 1 productFranance lists the Agilent BioTek 50 TS Microplate Washer in this category. Review the product record and specify the ELISA workflow, microplate format and wash configuration required by your laboratory.
Provide the 50 TS model reference, plate format, assay and wash requirements, requested accessories, quantity and destination. Ask Franance to confirm the quoted washer configuration and included components.
Provide the 50 TS or 800 TS reference, assay and plate format, required washer or absorbance-read workflow, software and accessories, quantity and laboratory location. Ask Franance to confirm the model and quoted configuration.
Where can I buy Agilent BioTek microplate instruments in Nigeria?
Start with the brand-filtered category for the instrument you need. The 50 TS washer listing currently covers the Agilent BioTek washer assigned to this category. The 800 TS reader listing covers the currently listed absorbance reader. The catalogue routes make it easier to compare the assigned models without mixing them with unrelated manufacturers.
Read moreWhat is Agilent BioTek and which products are listed?
BioTek instruments became part of Agilent Technologies in 2019. Agilent describes the BioTek portfolio as serving life-science research and laboratory workflows, including microplate instrumentation. Franance's current catalogue for this brand includes two products in distinct categories: the 50 TS microplate washer, listed as 50TS8 for 96-well plates, and the 800 TS absorbance microplate reader. The brand page should not be read as a complete inventory of all Agilent or BioTek products.
Read moreWhich Agilent BioTek 50 TS washer configuration is listed?
Franance lists the 50 TS microplate washer in the 50TS8 configuration. Agilent's technical details identify 50TS8 as a 96-well-only configuration. The same family supports choices associated with other part-number suffixes, so do not assume a listing for 50TS8 means every plate format or feature can be selected on the same unit. The washer should be matched to the laboratory's validated plate types and assay method.
Read moreBuy Agilent BioTek microplate equipment in Nigeria
Franance currently lists two Agilent BioTek instruments: the 50 TS microplate washer, part number 50TS8, and the 800 TS absorbance microplate reader. Both support plate-based laboratory workflows, but they perform different tasks. The washer automates liquid removal and dispensing steps; the reader measures absorbance for assays such as ELISA. Browse the Agilent BioTek washer listing and Agilent BioTek reader listing to see the current models assigned to Franance's catalogue. Agilent identifies BioTek as one of its instrument brands. Manufacturer specifications describe model capabilities and configuration differences, but they do not establish Nigerian stock, price, import status, delivery, local warranty or service for a specific unit. Franance takes quote orders; there is no online purchase checkout. Submit the exact model and workflow requirements, and Franance can follow up by email or phone with proposed terms. Confirm the part number, configuration, software, accessories, availability and commercial scope in writing before issuing a purchase order.
Where can I buy Agilent BioTek microplate instruments in Nigeria?
Start with the brand-filtered category for the instrument you need. The 50 TS washer listing currently covers the Agilent BioTek washer assigned to this category. The 800 TS reader listing covers the currently listed absorbance reader. The catalogue routes make it easier to compare the assigned models without mixing them with unrelated manufacturers.
To request a quote, identify your institution, instrument, quantity, destination city and state, and workflow. For a washer, include plate formats, wash protocols, fluid handling and optional functions. For a reader, include assay wavelengths, plate format, filters, incubation, shaking, software and connection needs. Franance follows up on submitted quote orders by email or telephone. A request is not an online purchase, reservation or proof of stock.
Ask for a written proposal that names the full model and part number, included manifolds or filters, installed software and licenses, computer or interface requirements, accessories, delivery scope and any service or warranty terms. Manufacturer information is useful for defining the required configuration; local availability and commercial terms must be confirmed separately for the particular order.
What is Agilent BioTek and which products are listed?
BioTek instruments became part of Agilent Technologies in 2019. Agilent describes the BioTek portfolio as serving life-science research and laboratory workflows, including microplate instrumentation. Franance's current catalogue for this brand includes two products in distinct categories: the 50 TS microplate washer, listed as 50TS8 for 96-well plates, and the 800 TS absorbance microplate reader. The brand page should not be read as a complete inventory of all Agilent or BioTek products.
The 50 TS performs programmed plate washing. Agilent's technical details describe wash-volume and cycle settings and list different part-number configurations for plate formats and optional functions. The 800 TS performs absorbance measurements and is used for workflows such as ELISA. Agilent's product page and configuration documentation distinguish base 800TS from suffix variants that change capabilities, such as wavelengths or incubation options. A family name does not determine which functions are installed on a particular offered unit.
Use the washer category when requesting a BioTek 50 TS and the reader category for the 800 TS. If your laboratory needs another BioTek reader, washer or cell-analysis instrument, give the exact part number in an enquiry; these two current listings do not cover every Agilent BioTek instrument.
Which Agilent BioTek 50 TS washer configuration is listed?
Franance lists the 50 TS microplate washer in the 50TS8 configuration. Agilent's technical details identify 50TS8 as a 96-well-only configuration. The same family supports choices associated with other part-number suffixes, so do not assume a listing for 50TS8 means every plate format or feature can be selected on the same unit. The washer should be matched to the laboratory's validated plate types and assay method.
Agilent describes a programmable wash-volume range of 25–3,000 µL per well and 1–10 wash cycles. The technical sheet also discusses optional functions and alternative configurations, including buffer switching, magnetic separation and vacuum filtration. Those capabilities should not be assumed to be included in the 50TS8 base package. Ask the supplier to identify the offered part number, manifold, bottle and tubing scope, and any special options line by line.
Before quotation, record the plate make and format, well geometry, wash protocol, target residual volume, fluid volumes, aspiration needs and number of buffers. If the process requires magnetic-bead separation or vacuum filtration, ask for confirmation of a compatible configuration and accessories. Provide information about reagents only to the degree needed to determine materials compatibility, and follow the laboratory's confidentiality practices.
The 50 TS technical sheet lists an external 24 VDC power supply compatible with 100–240 VAC, 50–60 Hz. Verify that the actual supplied power adapter and plug meet the facility's requirements. Confirm that any workstation or software needed for protocol programming is included. The published specification informs selection but does not verify local stock, supply, warranty or service for Nigeria.
Which Agilent BioTek 800 TS reader configuration should I request?
Franance lists an Agilent BioTek 800 TS absorbance reader. The specific catalogue record identifies the 800TS base configuration. Agilent describes the instrument for absorbance assays including ELISA and kinetic ELISA. Its technical documentation distinguishes multiple suffixes, including options that affect plate compatibility, UV measurement, incubation or other capabilities. Read the exact suffix in the quotation; “800 TS” alone is not enough to confirm that the offered configuration meets the assay.
For the 800TS base configuration, the cited Agilent material lists 6- to 96-well plate support and a 400–750 nm wavelength range. Other variants can differ. If your method needs wavelengths outside that range, incubation, shaking, temperature control or a particular plate format, identify those needs and ask for an exact compatible configuration. Do not infer an option from the instrument's external appearance or from a brochure for a different suffix.
State the assay names or method requirements, reading modes, wavelength or filters, plate format, speed, temperature control, shaking, software, data export and computer connection. Ask whether software licenses, a computer, cables, printer and accessories are included, and how the configuration will export results to your laboratory information or quality system. Confirm the power adapter specification; Agilent's technical details for the cited family list an external 24 VDC supply compatible with 100–240 VAC at 50–60 Hz.
The manufacturer classifies specific product variants for intended use; confirm the exact designation and local regulatory suitability for your application. Research-use and diagnostic claims must not be assumed interchangeable. The Franance catalogue entry and source documents do not certify registration or suitability for a particular regulated workflow in Nigeria.
What should I include when requesting a 50 TS washer quote?
Name the Agilent BioTek 50 TS and 50TS8 part number. Confirm that a 96-well format fits the planned plate and protocol. Provide the plate type, wash volume, cycle count, aspiration requirements, buffer count and whether an optional application such as magnetic separation or filtration is required. If those functions are essential, ask whether the currently listed reference includes them or whether a different reference should be considered. Request the exact proposed part number before comparing with another offer.
Specify the manifold and any interchangeable heads, bottles, reservoirs, tubing, waste containers and adapters needed. State your buffer composition or laboratory compatibility constraints when necessary. Define throughput and protocol programming needs and identify any PC, software or interface requirements. The quote should separate included accessories from optional equipment so staff know what will arrive and what needs to be sourced separately.
Include quantity, destination facility, city and state, expected delivery point and any receiving or installation limitations. Ask the proposal to list price, currency, validity period, estimated lead time, delivery and installation scope, operator familiarisation, warranty and service terms. Have the laboratory and biomedical engineering teams review the proposed accessories and facility power arrangement. No Nigerian stock or delivery commitment is established by the manufacturer's technical sheet.
What should I specify for an 800 TS absorbance reader quotation?
Identify the requested model as 800 TS and ask the response to show the precise suffix or Agilent part number. Explain the assays, absorbance method, wavelengths or filters, plate formats, incubation and shaking needs. State whether the listed base 800TS's 6–96 well and 400–750 nm capabilities match the work. If the method uses UV wavelengths, ask for the corresponding configured model and validation documentation rather than relying on the base reader listing.
List software, protocol, analysis, computer, network and data-export requirements. Specify whether you need printed output or integration to an existing laboratory system. Ask the quote to identify included software version and licensing, data formats, PC requirements, cables and any qualification or installation service. If the instrument will be used in a regulated or clinical workflow, have the responsible quality and regulatory staff verify intended use, local requirements and documentation before purchase.
State quantity and final destination in Nigeria. Request separate lines for instrument, accessories, optional features, freight, delivery, installation, training or qualification. Have the seller identify the supplied power supply and plug. Confirm the condition of the offered unit, current availability and quote validity explicitly. The listing supports enquiry, but every commercial and configuration detail needs confirmation on the written offer.
How do I choose between the BioTek 50 TS washer and 800 TS reader?
Choose by workflow stage. The washer automates washing steps in plate-based assays; the reader measures absorbance from a prepared plate. Some laboratories need both, but they are not substitutes. A reader does not wash plates, and a washer does not provide absorbance detection. Match each instrument to the method, throughput and operator workflow, then check that each plate format and accessory is compatible across the overall process.
For the washer, compare plate format, manifold, wash volume, cycle programming, aspiration, buffer switching and any magnetic-separation or filtration needs. For the reader, compare detection mode, wavelength range, plate compatibility, incubation or shaking, software and data handling. Ask the assay owner to provide the validated protocol and acceptance criteria so engineering and procurement can evaluate equivalent configurations rather than just similar model names.
If replacing an instrument, identify the existing model, accessories and data workflow, but do not assume old manifolds, plates, software or interfaces will transfer. Ask the supplier and Agilent documentation to confirm compatibility. For a new laboratory, consider bench space, power, ventilation if relevant, computer and network arrangements, waste handling and operator training. Record these dependencies in the specification and quote so the institution can plan full implementation cost.
What determines Agilent BioTek instrument price in Nigeria?
Price depends on the exact model, part-number suffix, installed options, accessory set, software and license scope, quantity, delivery point and commercial route for the quote. The 50TS8 plate format and 800 TS suffix variations illustrate why product-family pricing cannot be assumed for every configuration. Freight, import charges, currency, quote validity and requested installation or qualification can also affect the total project cost.
The Agilent sources describe technical features and configurations, not the current price available to a Nigerian buyer. Franance processes quote orders and follows up by email or telephone. Ask for an itemised offer that names the instrument reference, options, accessories, currency, price validity, payment schedule, lead-time assumptions, destination and costs that are excluded. Ask whether the quoted setup includes software, computer, cables, training, installation or acceptance documentation.
Compare offers on equivalent configurations. Verify that both proposals specify the same plate formats, wavelength range, options, accessories, software rights and support scope. Ask for written confirmation of stock or procurement status, delivery, warranty and service terms for the precise unit. Do not treat a generic website price, manufacturer list price or quote for another suffix as a final Nigerian price.
Can Franance deliver Agilent BioTek instruments to my Nigerian city?
The catalogue does not establish delivery coverage, cost or timing for a particular Nigerian location. Include the facility city, state and exact delivery address in the request. Note access constraints, building floors, lift dimensions, delivery hours and whether the lab requires advance notice. These details help assess logistics but are not a delivery confirmation.
Ask the written quote to say whether the price includes freight, customs or import costs, unloading, placement at the laboratory, installation and operator training. Confirm the proposed lead time and any conditions that could change it. Microplate instruments may require careful handling, and the facility should prepare a clean, stable bench and compatible power connection based on the exact unit's instructions. Have engineering confirm the installation needs before delivery.
Franance can review a quote order for the named destination and respond with proposed terms. Availability, delivery, warranty and support must be agreed for the individual order. Request the delivery destination, cost, schedule and party responsible for resolving transport issues in writing before your institution commits.
What should I verify before accepting an Agilent BioTek quotation?
Check the exact manufacturer, instrument, model suffix and part number against the approved specification and current Agilent documentation. Confirm plate type, format, detection or wash capabilities, included accessories, software version, licensing and power supply. Ask for clarification if an offer uses a family name without a detailed configuration. A substitution should be reviewed as a new configuration, not accepted because it has a similar product name.
Have the assay lead confirm that the unit supports the laboratory method and validated protocol. Have engineering review electrical and installation requirements. Quality or regulatory staff should confirm intended use, local requirements and necessary documentation. For the washer, document manifolds, fluids and options. For the reader, document wavelengths, filters, plate formats, incubation or shaking and data handling. Agree acceptance checks and who will perform them.
Review commercial conditions separately: availability status, price and currency, quote validity, delivery, installation, training, warranty, service contact, spare parts and exclusions. Manufacturer product pages do not establish those Nigerian terms. Request all commitments in the offer and preserve it with the final model and serial-number information. Franance's quote order is not completed until the parties agree the written terms.
How do I request an Agilent BioTek quotation from Franance?
Open the 50 TS microplate washer listing or the 800 TS absorbance reader listing, choose the required catalogue item and submit a quote request. Include model and part number, workflow, required plate format, configuration options, quantity and facility destination. A clear method specification is more useful than an instrument-family name alone.
Franance will follow up by email or phone to clarify the quote order. There is no online checkout, and submission does not reserve stock or confirm availability. Ask for a written quotation with the exact Agilent configuration, included accessories and software, price and currency, validity, destination, delivery scope and applicable terms. List any requested installation, qualification, training or warranty conditions.
Before accepting, have the laboratory, engineering, quality and procurement teams review the proposed configuration and terms. Verify the current Agilent manual and applicable intended-use information. Do not share patient data in an equipment enquiry; an assay name and non-confidential technical requirements are enough to describe the instrument need.
Common questions
What Agilent BioTek instruments are currently listed by Franance?
The current brand-filtered catalogue lists the 50 TS washer in 50TS8 configuration and the 800 TS absorbance reader. Verify the exact model and suffix in the quotation.
Does 50TS8 support every microplate format?
Agilent's technical details identify 50TS8 as a 96-well-only configuration. Confirm the plate format, manifold and options before ordering.
Does Franance sell BioTek instruments online?
No. Franance accepts quote orders and follows up by email or telephone. Availability and commercial terms must be confirmed in writing.
Request an Agilent BioTek quotation
Send the exact model and part number, assay workflow, required plate format, options, software and accessories, quantity and Nigerian destination. Franance can review your quote order and confirm proposed availability and terms.
Request an Agilent BioTek quoteNeed an equipment quote?
Add the models you need to a quote order, or send us your equipment list.


