Buy Medical Gas Cylinder Manifold in Nigeria.
Buy a medical gas cylinder manifold in Nigeria through Franance. The live category assigns Dräger Gas Control System Vi, BeaconMedaes Lifeline HTM and BeaconMedaes MAT-S HTM. Compare exact system references, then request a written project quotation with the gas schedule, demand basis, pipeline interface, site information and delivery requirements. Franance follows up by phone or email; the listing is quote-order only.
Products
8 models



Where can I request a medical gas cylinder manifold quote in Nigeria?
Browse the medical gas cylinder manifold category or open each exact brand and category filter: Dräger Gas Control System Vi, BeaconMedaes Lifeline HTM, and BeaconMedaes MAT-S HTM. Each query resolves to one product record in the current preview catalogue.
Read moreWhat does a medical gas cylinder manifold do?
A cylinder manifold is a source-side assembly that connects gas cylinders or cylinder banks to a medical gas supply system. Depending on the designed system, it may include gas-specific connections, pressure regulation, automatic source changeover, monitoring, alarms and connections into the downstream pipeline. Dräger describes Gas Control System Vi as a core component of a cylinder manifold system; BeaconMedaes describes Lifeline and MAT-S as automatic medical gas manifolds. The actual set of components and interfaces depends on the model configuration and project design.
Read moreWhat is the difference between a manual and automatic manifold?
In a manual changeover arrangement, an operator performs the source changeover using the specified cylinder or bank valves. BeaconMedaes describes its manual manifold family as requiring staff to close the empty cylinders and open the standby cylinders. Its semi-automatic family behaves differently: the system changes to the reserve bank when the in-use bank depletes, while staff still need to bring the standby bank online during cylinder replacement. A fully automatic manifold such as the listed Dräger Gas Control System Vi is described by Dräger as automatically switching between supply sources; the listed BeaconMedaes Lifeline HTM and MAT-S HTM are also identified by their manufacturer as automatic manifolds.
Read moreBuy a medical gas cylinder manifold in Nigeria
To buy a medical gas cylinder manifold in Nigeria, provide the facility’s gas schedule, demand and pipeline design basis, proposed cylinder-bank arrangement, site drawings, alarm requirements and destination, then request a project-specific quotation. The live Franance category currently has three assigned products: Dräger Gas Control System Vi, BeaconMedaes Lifeline HTM Automatic Manifold and BeaconMedaes MAT-S HTM Automatic Manifold. They are not interchangeable catalogue labels: ask the supplier to name the precise system, gas service, flow and pressure configuration, cylinders and controls offered. Franance accepts quote enquiries and follows up by phone or email; no online checkout, stock, price or Nigerian installation promise is made.
Where can I request a medical gas cylinder manifold quote in Nigeria?
Browse the medical gas cylinder manifold category or open each exact brand and category filter: Dräger Gas Control System Vi, BeaconMedaes Lifeline HTM, and BeaconMedaes MAT-S HTM. Each query resolves to one product record in the current preview catalogue.
For a quotation, use the Franance medical gas cylinder manifold enquiry form. Give the complete facility name and delivery address, gas services required, project stage, expected demand schedule, number and type of cylinder banks, pipeline pressure design and the requested installation or commissioning scope. Attach a current schematic or design brief if available. Ask the supplier to identify all assumptions and exclusions rather than treating a product-family page as a complete system specification.
The category’s live inventory is three catalogue records, including two distinct BeaconMedaes products. The MAT-S HTM is a separate record from the Lifeline HTM. Product data and manufacturer information must be compared at the correct model level; a capacity or feature statement for one range must not be carried across to the other.
What does a medical gas cylinder manifold do?
A cylinder manifold is a source-side assembly that connects gas cylinders or cylinder banks to a medical gas supply system. Depending on the designed system, it may include gas-specific connections, pressure regulation, automatic source changeover, monitoring, alarms and connections into the downstream pipeline. Dräger describes Gas Control System Vi as a core component of a cylinder manifold system; BeaconMedaes describes Lifeline and MAT-S as automatic medical gas manifolds. The actual set of components and interfaces depends on the model configuration and project design.
A manifold is one part of a medical gas pipeline system. It is not the terminal outlet at a patient bed, a bedside headwall, an area valve service unit or an oxygen concentrator. It also does not replace pipeline distribution, source reserve design, alarm destinations or clinical equipment connections. ISO 7396-1 addresses system-level requirements covering source systems, distribution, controls, monitoring and alarms; ordering a manifold alone does not design or verify a complete pipeline.
Do not assume that every medical gas is available in every quoted manifold, or that an oxygen manifold is appropriate for another gas. State the gas by its specified name and ask for compatible gas-specific regulators, cylinder connectors, pigtails, labels and outlet configuration. The project’s design authority should confirm the source system’s relationship to any bulk oxygen, oxygen-generation plant, reserve or emergency source already installed.
What is the difference between a manual and automatic manifold?
In a manual changeover arrangement, an operator performs the source changeover using the specified cylinder or bank valves. BeaconMedaes describes its manual manifold family as requiring staff to close the empty cylinders and open the standby cylinders. Its semi-automatic family behaves differently: the system changes to the reserve bank when the in-use bank depletes, while staff still need to bring the standby bank online during cylinder replacement. A fully automatic manifold such as the listed Dräger Gas Control System Vi is described by Dräger as automatically switching between supply sources; the listed BeaconMedaes Lifeline HTM and MAT-S HTM are also identified by their manufacturer as automatic manifolds.
These labels do not establish what is included in a specific quotation. The three products currently assigned to this Franance category are automatic product families; the catalogue does not list a manual manifold. Confirm the exact changeover sequence, staff actions, alarms, cylinder-bank controls and reserve behavior for the offered configuration, and assess operational coverage with the facility’s responsible gas-system authority. Do not treat “manual,” “semi-automatic” and “automatic” as interchangeable descriptions.
Buy Dräger Gas Control System Vi in Nigeria
Dräger describes Gas Control System Vi as a central component of a cylinder manifold that reduces pressure, monitors medical gases, switches automatically between supply sources and has integrated alarm management. Its product page characterizes the system as a configurable facility solution for different gases, flow rates, control and alarm functions. Dräger’s page lists gas options and flow configurations at product-family level, but the Franance record does not say which gas or flow variant is being offered. Do not select or publish a flow figure from the family page as if it were confirmed for this exact enquiry.
The Dräger page also describes a power-independent changeover valve and the ability to integrate relevant control-unit alarms into Dräger alarm-management products. These are manufacturer descriptions of the system family. Confirm the offered module, connection, alarm interface, operating sequence and requirements in current documentation for the selected configuration. If alarms must report to a continuously attended location or an existing facility system, provide the exact system details and ask for written compatibility and scope confirmation.
Use the Dräger Gas Control System Vi filtered listing and ask Franance to quote the gas service, peak and normal demand, required delivery pressure, source bank, reserve strategy, alarms, electrical and monitoring interfaces, manifold-room conditions and downstream system. The record does not identify a gas variant, flow code, cylinder count or alarm package, so every one must be resolved in the written offer.
Buy BeaconMedaes Lifeline HTM manifold in Nigeria
The BeaconMedaes Lifeline HTM page describes an automatic manifold for medical gas management. It lists a manufacturer-stated capacity of up to 1,750 litres per minute at 4 bar, digital pressure indications for both headers and the line, and a maintenance warning at 40,000 operating hours or five years. It also describes fail-safe solenoid valves in the event of power-supply failure and pre-installed items such as exhaust vents and wall brackets. These statements are for the manufacturer's Lifeline HTM information; confirm the exact offered configuration, applicable gas, rating conditions, alarms and included parts before using them in a design or comparison.
Do not assume that the 1,750 L/min figure applies to every gas, system pressure, cylinder set or configuration, or that the catalogue item includes a particular number or size of cylinders. Ask for the current technical data sheet and installation/maintenance instructions for the precise Lifeline HTM version. Confirm the cylinder-bank layout, regulator arrangement, gas-specific connections, required pigtails, relief and exhaust details, electrical input, control and alarm signals, mounting and clearances.
For an enquiry, send the BeaconMedaes Lifeline HTM filtered listing with the intended gas and design duty. Ask the quotation to state the rated flow and pressure basis for that offered model and provide the relevant documents. No product-family statement proves that this configuration is available, suitable or installed in a Nigerian project.
Buy BeaconMedaes MAT-S HTM manifold in Nigeria
The live catalogue separately assigns a BeaconMedaes MAT-S HTM automatic manifold. BeaconMedaes’ HTM product page describes MAT-S as an automatic medical gas manifold with a 7-inch touchscreen controller, remote-monitoring functionality through a Smartbox, gas-flow and pressure trends, and individually serviceable regulators. The page also describes model options and some specific high-flow and changeover figures. The Franance record does not identify a specific gas, capacity or flow variant; those model-family figures must not be applied to the requested configuration until the manufacturer confirms them.
Keep MAT-S separate from Lifeline in comparisons. Both are automatic manifold product families, but their listed functions, controls, documentation and configuration options are not necessarily the same. Ask which exact MAT-S HTM version is offered, which gas it serves, which regulator and cylinder-bank configuration is selected, and whether any monitoring module, network connection, service valves, test point or accessory is standard or optional. Confirm required power, communication, commissioning and alarm interfaces from the current documentation.
Use the BeaconMedaes MAT-S HTM filtered listing. Ask the supplier to state the exact product reference and provide the matching manufacturer datasheet and installation documentation. The HTM designation on a product page does not establish that the system or a project complies with Nigerian requirements.
How should I size a cylinder manifold for a hospital?
Start with the facility’s medical-gas design basis, not a guessed cylinder count. Ask the medical gas design authority to identify gases, connected departments, design flow and pressure, peak and normal demand, source redundancy, reserve capacity, expected cylinder delivery and storage constraints. Provide current pipeline drawings, proposed expansion, any existing source equipment and the intended point of connection. Ask the project engineer to reconcile these with the expected clinical services and applicable design criteria.
Manufacturer pages may publish a capacity for a particular range or variant, but that does not calculate the required supply for a hospital. Flow, pressure, gas, cylinder type, number of outlets, simultaneity assumptions, supply duration and cylinder-bank changeover all affect a project decision. The catalogue records do not identify these values. Request a written sizing basis for the selected configuration and retain the calculation and assumptions with the project file.
Plan resupply and resilience alongside nominal flow. Confirm the cylinder supplier’s available cylinder type, fill pressure, valve connection, delivery schedule and ability to replenish the designed bank. Ask the supplier and design engineer how the source and reserve arrangements behave in foreseeable changeover, depleted-bank, power-failure, maintenance and alarm conditions. This guide does not prescribe a cylinder reserve or guarantee uninterrupted supply; those are project-specific engineering decisions.
Which gases, cylinder banks and alarms should be specified?
Provide a gas schedule that names each gas or mixture and identifies where it is used in the facility. Request the manufacturer to confirm gas-specific components and exact connector arrangements. Do not rely only on color or a generic description such as “oxygen manifold.” The project specification should identify primary and reserve banks, required changeover behavior, pressure and flow requirements, alarm conditions, signal outputs, locations for alarm indication and who is expected to respond.
Ask the manufacturer to describe the control and alarm behavior during normal supply, bank depletion, changeover, power loss, a regulator fault and maintenance isolation. Verify which alerts are local to the manifold, which may be repeated remotely and what electrical or communications infrastructure is needed. If the system is to report to a central medical gas alarm panel, building management system or digital platform, provide the make, model, interface and versions and request project-specific interoperability confirmation.
Cylinder storage, handling, ventilation, security, access and separation from other activities require review by competent local engineering and safety teams. Provide site drawings and room details rather than asking the supplier to assume a standard room. The manifold should be placed and installed in accordance with applicable manufacturer instructions, the project design and rules adopted for the Nigerian site.
What should a Nigerian site survey cover?
A quote-ready site survey should establish the location and dimensions of the manifold room or enclosure, access for cylinder delivery and replacement, door and route dimensions, ventilation and exhaust arrangements, ambient conditions, mounting surface, service clearances, electrical supply and alarm/network routes. Include existing pipeline pressure, gas identity, line size and connection location only as verified by project documents or qualified inspection. Ask the project engineer to confirm whether the facility requires a new source system, replacement manifold, additional bank or integration with another source.
Document existing plant and downstream demand. Identify bulk liquid oxygen, oxygen concentrators, secondary cylinder source, medical-air plant, emergency backup, alarms, area valves and pipeline sections that may interact with the work. This helps prevent a manifold quotation from being mistaken for a full medical gas project scope. If there is a live system modification, state the shutdown window, temporary supply plan and authorization process; do not plan maintenance or changeover without the responsible system authority.
For Nigerian projects, provide the precise state and city, site access and security requirements, power characteristics, climate and environmental conditions relevant to the installation, procurement schedule and the responsible engineering contacts. Ask the supplier to identify what it needs to verify locally and what documentation or technical visits can actually be provided. The guide does not claim local installation or service availability.
Which standards apply to a medical gas manifold project in Nigeria?
ISO 7396-1 is an international standard for medical gas pipeline systems carrying compressed medical gases and vacuum. The ISO scope covers design, installation, function, performance, testing, commissioning and documentation, and includes source systems, distribution, controls, monitoring and alarms. Its online record says the 2016 edition was confirmed in 2022 and is subject to an amendment, while a replacement is expected; verify the applicable current edition and amendments when the project is specified.
BeaconMedaes offers products labelled HTM, and its pages cite HTM 02-01 and ISO 7396-1 for some products. NHS England’s HTM 02-01 is UK healthcare engineering guidance. It may be a useful technical reference, but it is not proof that a system complies with Nigerian law or the project’s governing requirements. Likewise, an ISO or HTM statement on a manufacturer page does not certify the complete installation, gas source, pipeline or commissioning for a particular Nigerian facility.
Have the client, design authority and qualified local professionals identify applicable Nigerian laws, authority approvals, project standards, gas quality rules, installation responsibilities and acceptance requirements. Put the governing standard editions, deviations and required records into the design and contract documents. Do not infer legal compliance from a product label or from another country’s technical guidance.
What testing, commissioning and handover should the quotation define?
Ask for the project scope to separate manufacture and delivery from site installation, system integration, testing, commissioning, validation, documentation, user instruction and ongoing maintenance. Identify who is responsible for the manifold, cylinder racks and pigtails, pipeline connection, alarm and power connections, gas identification and any integration to the existing alarm system. Ask which party provides the approved gas, test equipment, permit and required access.
ISO 7396-1 addresses testing, commissioning and documentation at the pipeline-system level. The design authority should specify the required test plan and acceptance criteria for the complete facility system, not only the manifold. Request the manufacturer’s current installation, operation and maintenance documents, the exact configured schematic, connection schedule, alarm matrix, serial and component list, test evidence, maintenance schedule and handover training scope.
For an existing facility, ask how isolation, temporary supply, return-to-service authorization and records will be managed under the site’s approved procedures. Have the responsible medical gas authority approve the work and commissioning documents before the system is released for use. No specific test result, certification or commissioning service is included simply by selecting a model in the Franance catalogue.
What should I include in a medical gas cylinder manifold quote request?
Send the precise product or comparison request, facility and destination state/city, gas schedule, design flow and pressure basis, number and type of cylinder banks, existing source equipment and pipeline interface, current drawings, room dimensions, power and alarm requirements, cylinder supplier details and any expansion plans. Include access, delivery and security restrictions, project stage, required date and the names of the design and facility engineering contacts.
Ask Franance for an itemized quotation identifying the exact manufacturer, product reference, gas configuration, rated operating conditions, regulator and control arrangement, included cylinder connections and accessories, electrical and alarm interfaces, dimensions, mounting and environmental requirements, and every excluded item. Request current manufacturer datasheets and instructions, project-specific compatibility confirmation, design and commissioning boundaries, freight, delivery, site installation, testing, training, warranty and local service terms. Require the offer to distinguish manufacturer-published variant data from the exact proposed model.
Use the medical gas cylinder manifold catalogue and send the request through the Franance manifold quotation form. Franance follows up by phone or email to clarify the quote order. This is not an online purchase or a commitment that a specific configuration is currently stocked.
What is verified about the assigned products and what remains uncertain?
The current preview category contains three catalogue products: Dräger Gas Control System Vi, BeaconMedaes Lifeline HTM Automatic Medical Gas Manifold and BeaconMedaes MAT-S HTM Automatic Medical Gas Manifold. Dräger’s Gas Control System Vi product page describes automatic changeover, pressure reduction and monitoring, alarm-management features and configurable facility options. BeaconMedaes’ Lifeline HTM page describes the Lifeline automatic manifold and publishes capacity and feature information for its product range. Its separate MAT-S HTM page describes MAT-S features and its family-level options.
The ISO 7396-1 standard record defines relevant pipeline-system scope. NHS England HTM 02-01 provides UK healthcare engineering guidance for design, installation, validation, verification and operational management. It is cited as a technical reference only, not as a Nigerian compliance determination.
The catalogue does not establish the exact gas, flow, pressure, cylinder-bank capacity, connection, alarm package, voltage, region-specific variant, supplied accessories or project services for any of these three records. Confirm each in the manufacturer’s current documentation and written quote. No Nigerian price, stock, import status, certification, delivery timing, installation, warranty, distributor status or local service coverage is claimed.
Common questions
How many products are currently assigned to the cylinder manifold category?
The live preview has three: Dräger Gas Control System Vi, BeaconMedaes Lifeline HTM and BeaconMedaes MAT-S HTM. The two BeaconMedaes models are separate catalogue records.
Does a manifold listing define the gas or flow configuration?
No. The current records do not specify an exact gas, flow, pressure or cylinder-bank variant. Confirm the proposed configuration with current manufacturer documentation and the project design authority.
Does ISO or HTM wording prove Nigerian project compliance?
No. ISO 7396-1 is relevant international technical context and HTM 02-01 is NHS England guidance. The project authority and qualified local professionals must determine applicable Nigerian rules and acceptance requirements.
Can I buy a medical gas manifold online from Franance?
No. Submit a quote enquiry with the model, design basis and destination; Franance follows up by phone or email with a written quotation.
Request a medical gas cylinder manifold quotation in Nigeria.
Send Franance the exact manufacturer system, gas schedule, design flow and pressure, cylinder banks, site drawings, power and alarm requirements, destination and project scope. Franance will follow up by phone or email with a quote order.
Request a quotationNeed an equipment quote?
Add the models you need to a quote order, or send us your equipment list.