Buy radiation dosimeters and TLD badges in Nigeria through Franance by identifying the monitoring method and programme your facility requires. The current category lists two electronic personal dosimeters—Thermo Scientific EPD TruDose and Mirion Instadose 2—not passive TLD badges. Compare the exact variant, readout and reporting workflow, then request a quote order for your facility. Franance follows up by phone or email; confirm availability and terms in writing.

Where can I buy radiation dosimeters and TLD badges in Nigeria?

Start with Franance’s radiation dosimeter category. Its current assignments are EPD TruDose, an electronic personal dosimeter family from Thermo Scientific, and Mirion Instadose 2, a wireless dual-detector electronic dosimeter. Select the exact listing that matches your specification and submit a quotation request through Franance contact. Include the facility name, number of wearers, full address, city and state, and the date by which you need a confirmed offer.

Read more

Which radiation dosimeters does Franance currently list?

Franance lists two electronic personal dosimeter options in this category. Thermo Scientific EPD TruDose is a family with G, BG and NG variants. Thermo’s product page describes G for gamma, BG for beta and gamma, and NG for neutron and gamma monitoring. It also describes dose and dose-rate monitoring, alarms, and optional telemetry/integration. These variants are not interchangeable: the radiation type and workflow must match the facility requirement and exact offer.

Read more

Is an electronic dosimeter the same as a TLD badge?

No. An electronic personal dosimeter provides electronic measurements and may display or communicate dose information according to its design. A passive TLD badge uses a thermoluminescent detector that is processed by a suitable reader after its monitoring period. They differ in detector technology, readout, operating workflow, data access and service needs. A passive badge programme ordinarily involves badge issue and return, processing, dose reporting and a documented arrangement for handling results. An electronic model may instead depend on device configuration, readers or transmission hardware, software, accounts, alarm settings and defined data procedures.

Read more

Buy Radiation Dosimeters and TLD Badges in Nigeria

Buy radiation dosimeters and TLD badges in Nigeria through Franance by first identifying the monitoring method and programme your facility requires. Franance currently lists two electronic personal dosimeters in this category: Thermo Scientific EPD TruDose and Mirion Instadose 2. They are not passive thermoluminescent (TLD) badges. If your specification calls for a TLD service, passive badge processing, or a particular accredited provider, state that requirement explicitly; the current two product listings do not establish that those services are included. Review the radiation dosimeter and badge listings, compare the exact product records for EPD TruDose and Mirion Instadose 2, then send Franance a quote order with the required variant, quantity, monitoring and reporting scope, and destination. Franance follows up by phone or email; the website does not take online payment. Confirm price, availability, delivery, service and regulatory terms in the written offer.

Where can I buy radiation dosimeters and TLD badges in Nigeria?

Start with Franance’s radiation dosimeter category. Its current assignments are EPD TruDose, an electronic personal dosimeter family from Thermo Scientific, and Mirion Instadose 2, a wireless dual-detector electronic dosimeter. Select the exact listing that matches your specification and submit a quotation request through Franance contact. Include the facility name, number of wearers, full address, city and state, and the date by which you need a confirmed offer.

The category title also uses “TLD badge,” a common monitoring term, but neither current assigned product is a TLD. TLD describes a passive detector technology; these two catalogue items are electronic devices. No passive TLD badge or badge-processing service is represented in the present category assignments. If your facility requires passive TLD badges, specify the detector, provider/service arrangement, monitoring period and reporting requirements and ask Franance to confirm whether that exact scope can be quoted. Do not treat a category keyword or enquiry as proof that a particular detector or service is available.

The catalogue is an equipment discovery and quotation channel. The product pages and manufacturer sources do not verify Nigerian stock, an appointed distributor relationship, import status, local service coverage or a delivery date. Franance will follow up on an enquiry, and the written quotation should identify precisely what is being offered.

Which radiation dosimeters does Franance currently list?

Franance lists two electronic personal dosimeter options in this category. Thermo Scientific EPD TruDose is a family with G, BG and NG variants. Thermo’s product page describes G for gamma, BG for beta and gamma, and NG for neutron and gamma monitoring. It also describes dose and dose-rate monitoring, alarms, and optional telemetry/integration. These variants are not interchangeable: the radiation type and workflow must match the facility requirement and exact offer.

Mirion Instadose 2 is described by Mirion as a wireless dual-detector dosimeter. Mirion identifies deep dose Hp(10) and shallow dose Hp(0.07) measurements for photon and beta radiation sources, Direct Ion Storage technology and Bluetooth communication. Mirion’s product description discusses on-demand capture, transmission, analysis and reporting through an enabled transmission source and an associated account/platform workflow. Confirm the exact hardware, access, account, reporting and service components required for use in Nigeria.

Both product families are electronic personal dosimeters, not a complete occupational radiation-protection programme. The product listing does not show that a registered or accredited dosimetry service, processing laboratory, reader, platform subscription, integration, calibration service, training, replacement cycle or local technical support is included. Ask the quotation to name each included and excluded element.

Is an electronic dosimeter the same as a TLD badge?

No. An electronic personal dosimeter provides electronic measurements and may display or communicate dose information according to its design. A passive TLD badge uses a thermoluminescent detector that is processed by a suitable reader after its monitoring period. They differ in detector technology, readout, operating workflow, data access and service needs. A passive badge programme ordinarily involves badge issue and return, processing, dose reporting and a documented arrangement for handling results. An electronic model may instead depend on device configuration, readers or transmission hardware, software, accounts, alarm settings and defined data procedures.

Do not assume that an electronic device removes the need for a service provider or formal dose records, or that a passive badge provides real-time readings. The monitoring method should be chosen by the facility’s Radiation Safety Officer (RSO), medical physicist or other responsible qualified professional with reference to current Nigerian requirements and the approved radiation-protection programme. The product page is not a recommendation for a worker’s monitoring method.

Keep personal dosimeters distinct from area radiation survey meters, environmental monitors, patient-dose meters and dosimetry integrated into imaging equipment. These measure different things and have separate roles. A personal dosimeter records information for an assigned wearer; it does not shield the wearer, measure every room condition, directly control an X-ray system, or replace local rules, training, equipment controls and room shielding.

What do Hp(10) and Hp(0.07) mean?

Hp(10) and Hp(0.07) are personal dose equivalent quantities at specified depths in tissue-equivalent material: 10 mm for deep dose and 0.07 mm for shallow dose. They are measurement quantities used for personal monitoring, not product model names and not a complete interpretation of an individual worker’s exposure. Mirion describes Instadose 2 as having separate deep Hp(10) and shallow Hp(0.07) measurements for photon and beta sources. A buyer should not infer that every dosimeter has the same channels, radiation response or energy range.

Thermo EPD TruDose’s G, BG and NG designations identify the radiation variants stated on the manufacturer’s page. They do not by themselves define every required dose quantity, approved use, alarm threshold or reporting protocol for a facility. Ask the manufacturer or qualified supplier to provide current model documentation that maps the offered variant to your required radiation types, operational quantities, measurement range, response and calibration status. Have the RSO or medical physicist confirm that the requested configuration fits the monitoring programme.

When a worker wears a protective apron, badge placement and any need for one or more dosimeters should follow the applicable NNRA requirements and the facility’s written policy. Do not choose badge position or infer a dose from a product photograph or an online description. The NNRA’s diagnostic and interventional radiology requirements refer to policies for assigning monitoring badges, reviewing individual doses and defining actions when values exceed reference levels. The responsible local radiation-safety professional should turn those requirements into facility procedures.

How should a hospital choose between EPD TruDose and Instadose 2?

Begin with the programme, not the brand. Document who is monitored, what radiation types and dose quantities must be assessed, how often readings and reports are needed, who reviews results, what action follows an investigation level, how badges are assigned and how records are retained. Then compare each exact model against that written requirement and the current manufacturer documentation.

For EPD TruDose, specify the required G, BG or NG variant and confirm the offered model reference. Thermo’s page describes BLE and IrDA communications and a display with audible, vibration and visual alarms. It also states that the product family is available with or without telemetry and can integrate with certain systems, including ViewPoint and webREMS. The listing alone does not establish that the required reader, telemetry, software, integration, configuration, battery or service is included in a Franance quotation. Confirm the full package and compatibility in writing.

For Instadose 2, Mirion describes wireless data transfer and on-demand reading, dual Hp(10)/Hp(0.07) detectors, and dose-data access through an enabled transmission source and account/platform. Confirm the transmission arrangement and whether compatible hardware, platform access, administrator tools, reporting and ongoing services are part of the offer. The ability to view data in a manufacturer-described workflow does not prove connectivity, account availability, regulatory acceptance or local support for your Nigerian facility.

Compare the approved detector type, radiation response, required dose quantities, readout path, data ownership and access, alarms, reporting, calibration evidence, maintenance, privacy controls, replacement workflow, quantity and total programme cost. If an essential requirement is missing from a manufacturer document or offer, ask for written clarification instead of assuming it is supported. A different brand or electronic format is not automatically suitable merely because it is available in a catalogue.

What should I include in a radiation dosimeter quotation request?

Send Franance enough detail to quote the complete requirement. Identify whether you need electronic personal dosimeters or a passive TLD badge programme, then state the manufacturer and exact model or variant if specified. Include the number of monitored workers, number of devices, intended radiation types, required measurement quantities, facility modality and procedure context, monitoring period, reading/reporting frequency, alarm needs, reader or transmission infrastructure, platform or integration, calibration documents and any training, maintenance or service requirements.

Also describe the existing system and who will operate it. For an electronic model, list required reader, receiver, telemetry, network, software, user accounts, data export, integration and administrator roles. For a passive badge service, state who will issue and process badges, how badges are returned, the schedule for replacement and reporting, how dose results will be delivered, and what provider qualification or accreditation documents the facility requires. A badge without an agreed reading and reporting workflow may not meet the intended operational need.

Include procurement details: facility and procurement contact, quantity by model/variant, facility location, complete delivery address, city and state, requested date, tender or budget documentation requirements, and any required compliance documents. Ask the written quotation to separate product, reader, software/service, accessories, shipping, taxes, calibration, training, maintenance and other scope. Ask it to state validity, availability and delivery terms rather than assuming a catalogue listing establishes them.

Franance handles quote orders and follows up by phone or email. It does not accept online payment through the product catalogue. Use the product-filtered listing to identify the catalogue items and send the exact requirements through the radiation dosimeter enquiry form. Before approving an order, have the offer reviewed by the facility’s RSO or medical physicist and by the procurement team.

What Nigerian radiation-safety requirements should a buyer check?

The Nigerian Nuclear Regulatory Authority (NNRA) publishes minimum requirements for authorization of diagnostic and interventional radiology facilities. Its public information refers to engagement of an NNRA-accredited Dosimetry Service Provider for monitoring staff involved in X-ray operations, policies for assigning monitoring badges, review of individual doses, reference levels and actions when values are exceeded. It also addresses broader radiation-protection programme, local rules and facility requirements. Verify the current NNRA materials and applicable rules with the Authority and a qualified Nigerian radiation-safety professional before choosing equipment or a service arrangement.

The NNRA also publishes information on accreditation of dosimetry service providers, including the scope of dosimetry work. This is relevant when an organisation needs a monitoring service; it should not be conflated with buying a device. A dosimeter’s manufacturer specifications or accreditation statements for another country do not establish that the product, provider or service is accepted for a particular Nigerian facility. Ask what documentation applies to the exact device and service, who is responsible for calibration and reporting, and which local approvals or provider qualifications must be verified.

This guide is procurement information, not legal advice, a regulatory determination or an individual radiation-safety recommendation. Rules can change, and requirements depend on facility type and practice. Do not treat the presence of a product on a commercial site as proof of NNRA approval, registration, accreditation, conformity or compliance. Obtain current confirmation from the relevant Nigerian authority and facility’s qualified advisers.

What affects radiation dosimeter prices in Nigeria?

Franance does not publish a confirmed fixed price for these dosimeters or a TLD service. Request a current quotation for the exact model, variant, quantity, software or reader requirements and Nigerian destination. The commercial scope may differ depending on the device, accessories, transmission hardware, account or platform, integration, service arrangement, reporting, calibration documents, shipping and other requested work. The quote should make these items explicit so the facility can compare offers on the same basis.

No price, stock level, lead time, warranty, local calibration, local support, import arrangement or delivery coverage can be inferred from manufacturer product pages or a catalogue card. Ask Franance to confirm availability and delivery for your full destination address and to provide current quote validity and terms in writing. If a dosimetry service is required, separately confirm the provider, its authorization/accreditation scope, reporting workflow and ongoing charges. The device price alone may not represent the total cost of a compliant operational programme.

Can Franance deliver dosimeters to Lagos, Abuja or other Nigerian states?

Send the complete facility address, city and state so Franance can check and state delivery terms in a written offer. A mention of Nigeria, Lagos or Abuja on a page is not a promise of stock, nationwide delivery, installation, setup, local training or service. Confirm what can be supplied to your destination and by when before basing a project schedule on it.

For an electronic system, clarify who configures the variant, readers, telemetry, account, software and data workflow, and who verifies the system is working at the facility. For a badge service, identify the Nigerian provider and how collection, processing, result reporting, replacement and escalation will work. Confirm who trains wearers and administrators and how problems such as a lost, damaged or unreturned badge are handled. These operational responsibilities are separate from shipping a device.

Franance can review a quote enquiry, contact you by phone or email and confirm whether the requested scope can be offered. The written quotation should state delivery destination, dates, scope, exclusions and commercial terms. Do not assume local offices, installation or after-sales coverage unless the offer confirms it.

How do I place a radiation dosimeter quote order with Franance?

Open the category listings, choose EPD TruDose or Mirion Instadose 2, and submit a quote enquiry to Franance. Specify the exact radiation variant or dose-channel requirement, wearer quantity, readout and reporting workflow, local service expectations, destination and procurement timeline. If you require TLD badges or processing, say so plainly, because the two listed products are electronic dosimeters.

Ask Franance to identify the offered manufacturer, model and configuration; all hardware, software and services included; calibration and regulatory documents; availability; price validity; delivery terms; warranty or service scope if offered; and all exclusions. Compare the written offer with the facility’s approved monitoring specification and applicable NNRA requirements. Have the RSO or medical physicist review the technical match before procurement approval. Franance’s catalogue supports quotation orders rather than online checkout; payment and order terms are confirmed outside the catalogue in the written commercial process.

Sources and evidence limits

This guide uses the current manufacturer pages for Thermo Scientific EPD TruDose and Mirion Instadose 2, the NNRA diagnostic and interventional radiology requirements, NNRA dosimetry service provider information, and relevant IAEA recommendations in SSG-46. The current Franance category contains two direct electronic dosimeter assignments; it does not currently list a passive TLD badge product or a badge-processing service.

Manufacturer pages describe product features but do not establish Nigerian availability, service coverage, price, warranty, import status or facility compliance. Regulatory rules and provider status must be checked at the time of procurement. Technical selection and monitoring procedures belong to the facility’s qualified radiation-safety professionals.

Common questions

Does Franance currently list TLD badges?

The current category lists two electronic personal dosimeters, Thermo Scientific EPD TruDose and Mirion Instadose 2. It does not currently list a passive TLD badge product or processing service. State a TLD requirement explicitly and ask Franance to confirm whether that scope can be quoted.

Which electronic dosimeter models are in the category?

The current assignments are Thermo Scientific EPD TruDose and Mirion Instadose 2. EPD TruDose has G, BG and NG radiation variants; Mirion describes Instadose 2 as a wireless dual-detector model with Hp(10) and Hp(0.07) measurements. Confirm exact configuration and commercial scope in writing.

Does buying a personal dosimeter include NNRA-compliant monitoring service?

No such service is established by the product listing. NNRA publishes requirements concerning accredited dosimetry service providers and facility badge-assignment and dose-review policies. Confirm the required provider, calibration, readout, reporting and approvals for the facility with the NNRA and qualified radiation-safety professionals.

Can I buy a radiation dosimeter online from Franance?

No. Use the catalogue to identify the product and submit a quote order. Franance follows up by phone or email; the written offer confirms price, availability, scope and delivery terms.

Request a radiation dosimeter quotation from Franance.

Send the required monitoring method, exact manufacturer/model/variant, wearer quantity, reporting workflow, service-provider and calibration requirements, facility name, full Nigerian address and timeline. State explicitly if you need passive TLD badges or processing, because the current catalogue assignments are electronic dosimeters. Franance will follow up by phone or email; have the RSO or medical physicist review the written technical and commercial offer before procurement approval.

Request a radiation dosimeter quote

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart