Drive Medical 18302GDEL CGA870 Oxygen Cylinder Regulator
Click-style oxygen cylinder regulator
Medical equipment and biomedical engineering.
Abuja, Nigeria.
Buy oxygen cylinder regulators in Nigeria through Franance. The category lists Drive Medical 18302GDEL with CGA870/DISS, Drive DeVilbiss 18302GMN with CGA870/barb, and GCE MEDISELECT II 0720223 with pin-index/9/16. Verify cylinder valve and service pressure, regulator inlet rating, flow range and downstream connection before ordering. Franance follows up by phone or email; there is no online checkout.
8 models

Click-style oxygen cylinder regulator

Oxygen cylinder mini regulator

High-pressure medical oxygen cylinder regulator



Oxygen Regulator with Flowmeter & Humidifier Bottle

Oxygen Preset Regulator with Pin Index Valve

Regulator Single Stage Singe Gauge with Pin Index Valve
The current Franance category assigns three regulator models:
Read moreThe 18302GDEL and 18302GMN share a CGA870 inlet, 0–15 LPM selector range and specified flow positions: 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12 and 15 LPM. Drive lists 300–3,000 PSI inlet pressure and 50 PSI outlet pressure for this regulator family. Check the exact product’s current manufacturer instructions and label before matching it to a cylinder. The stated pressure range is not a substitute for verifying the cylinder’s marked service pressure and valve type.
Read moreGCE’s article 0720223 is specifically listed in the manufacturer’s medical catalogue as an oxygen MEDISELECT II regulator with 0–25 L/min flow range, pin-index inlet, 9/16 outlet and 200 bar inlet pressure. GCE’s MEDISELECT II product information shows that the broader family is available with multiple flow ranges, inlet connections and outlets. Other family variants include bullnose connections, lower or different flow scales, quick-release connectors and different pressure ratings. Do not use generic family information to substitute a different article number for the assigned 0720223.
Read moreFranance lists three oxygen regulators: Drive Medical 18302GDEL with a CGA870 inlet and DISS outlet, Drive DeVilbiss 18302GMN with a CGA870 inlet and barb outlet, and GCE MEDISELECT II article 0720223 with a pin-index inlet and 9/16 outlet. The Drive models have 0–15 LPM flow selectors and a manufacturer-listed inlet range of 300–3,000 PSI; GCE’s assigned article is a 0–25 L/min model for a 200 bar cylinder. They are different regulator families and connection systems. Match the inlet to the exact cylinder valve and working pressure, then check the outlet against the required equipment. Franance sells by quotation and follows up by phone or email; there is no online checkout.
The current Franance category assigns three regulator models:
- Drive Medical 18302GDEL CGA870 oxygen regulator
- Drive DeVilbiss 18302GMN CGA870 mini regulator
- GCE MEDISELECT II oxygen regulator, article 0720223
Drive’s 18302GDEL is a click-style regulator with a CGA870 cylinder inlet and DISS outlet. The 18302GMN is a mini regulator with the same CGA870 inlet standard but a barb outlet. GCE’s 0720223 is listed as a MEDISELECT II oxygen therapy flow regulator with pin-index inlet, 9/16 outlet, 0–25 L/min settings and a 200 bar inlet-pressure configuration. A general GCE MEDISELECT II family page lists several inlet/outlet and flow variants; the part number, not the family name alone, determines what is being supplied.
These records are regulators, not oxygen cylinders. A regulator does not provide oxygen by itself. Confirm whether the quote includes a cylinder, compatible valve, outlet connector, humidifier or tubing. The category listing does not establish that it does.
The 18302GDEL and 18302GMN share a CGA870 inlet, 0–15 LPM selector range and specified flow positions: 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12 and 15 LPM. Drive lists 300–3,000 PSI inlet pressure and 50 PSI outlet pressure for this regulator family. Check the exact product’s current manufacturer instructions and label before matching it to a cylinder. The stated pressure range is not a substitute for verifying the cylinder’s marked service pressure and valve type.
Their outlet ends differ. Drive describes 18302GDEL as an elongated regulator for a humidifier with a DISS outlet. Drive describes 18302GMN as a mini regulator with a barb outlet, with the mini form factor intended to fit more easily in oxygen carry bags. The barb is not a DISS fitting. If your downstream equipment expects a humidifier connector, tubing barb, quick connector or another standard, name it explicitly and ask for confirmation rather than adding an improvised adapter.
Both models have a contents gauge and built-in pressure relief valve per Drive’s published regulator information. Those features do not replace required cylinder checks, flow verification, maintenance or clinical monitoring. A selector knob setting is not a clinical prescription. The clinical team must determine the prescribed delivery requirement and the selected regulator’s suitability for that application.
GCE’s article 0720223 is specifically listed in the manufacturer’s medical catalogue as an oxygen MEDISELECT II regulator with 0–25 L/min flow range, pin-index inlet, 9/16 outlet and 200 bar inlet pressure. GCE’s MEDISELECT II product information shows that the broader family is available with multiple flow ranges, inlet connections and outlets. Other family variants include bullnose connections, lower or different flow scales, quick-release connectors and different pressure ratings. Do not use generic family information to substitute a different article number for the assigned 0720223.
The manufacturer’s current family page includes technical data for product configurations up to 300 bar. That does not make the 0720223 assigned item a 300 bar model. Treat the exact article specification and regulator label as controlling. Confirm the pin-index arrangement is correct for the oxygen cylinder valve in the destination facility, and confirm that the cylinder’s own current stamp and working pressure are within the regulator configuration’s rated limits.
GCE specifies 9/16 as one possible outlet in its family technical data and on the assigned article listing. The precise hose, humidifier, flowmeter or downstream connector still needs to be checked against the device and manufacturer instructions. If the facility requires a different connector or flow range, ask Franance to quote the correct GCE article or another approved configuration rather than assuming the 0720223 can be adapted.
Start with the cylinder’s permanent markings and the precise valve outlet. CGA870, pin-index, bullnose and other cylinder connections are not synonyms. Confirm gas type, inlet connection, maximum working pressure, regulator inlet pressure range, required seal or washer, cylinder test status and the specific manufacturer-approved combination. A connector that appears to fit is not proof that it is suitable for the gas, pressure or application. Never force, modify or cross-thread a fitting, and never use an adapter as a workaround without written manufacturer approval.
Drive’s assigned regulators list CGA870 and 300–3,000 PSI inlet pressure. This is a U.S. connection and pressure specification; ask Franance to verify the exact cylinder valve and working-pressure compatibility for the Nigerian-supplied cylinder. GCE’s 0720223 is a pin-index oxygen model listed at 200 bar. Pin-index systems use a particular valve-pin pattern, and the cylinder valve and regulator must match for the intended gas. Do not assume a CGA870 regulator attaches to a Luxfer 25E cylinder valve, or that any pin-index regulator fits any medical cylinder.
Ask the supplier to provide a written fitment schedule listing cylinder manufacturer/model, valve standard, cylinder service pressure, regulator model, inlet rating, outlet type and connected accessory. If the cylinder and regulator are supplied separately, the facility’s biomedical engineering or medical-gas team should validate that combination before accepting it. Each component’s rating matters; a regulator with a higher pressure rating does not increase the cylinder’s approved service pressure.
Identify the exact equipment that will connect to the regulator. Give its inlet or tubing connection, any humidifier requirement, requested flow settings and pressure needs. Drive 18302GDEL has the DISS outlet; Drive 18302GMN has a barb outlet. GCE 0720223 is catalogued with a 9/16 outlet. These outlet forms are not interchangeable. Confirm connectors and tubing are oxygen-service compatible, correctly rated and supplied in the quote. Do not use petroleum-based lubricants, household tubing or unapproved accessories on oxygen equipment.
Check the regulator’s flow increments against the clinical specification. The two Drive 15 LPM models have discrete settings up to 15 LPM, while GCE 0720223 is listed with selectable values from 0 to 25 L/min in its manufacturer catalogue. This does not establish that every downstream therapy device supports those values or that a patient should receive the maximum available flow. The care team must specify the required flow and monitoring. Ask the supplier to clarify the accuracy, operating conditions and required maintenance from the current instructions for use.
Confirm gauge units and visibility, relief-valve service, inspection schedule and what happens if a leak or damage is found. Request the regulator’s current label, manufacturer instructions, warranty and part number. If the quote includes an accessory or adapter, require its exact item code and written compatibility with both the regulator and the connected equipment.
Store regulators clean, dry and protected from impact, dust, heat, oil and grease, with their connections protected as directed by the manufacturer. Keep them associated with the assigned cylinder or equipment set so that different valve and outlet configurations are not mixed. Use trained staff for inspection, fitting and removal; follow manufacturer instructions and facility medical-gas procedures. Do not use a regulator that is damaged, contaminated, leaking, corroded, overdue for inspection or difficult to fit. Remove it from service according to facility process and have it assessed by the supplier or qualified service provider.
When regulators move between locations, protect the inlet and outlet from dirt and impact, and identify the gas and connection type clearly. If regulators travel with cylinders, verify that cylinder and regulator remain a compatible matched set, and follow transport requirements for the cylinder. The regulator itself does not make a cylinder safe to transport or store. Facility biomedical engineering should maintain a record of model, serial number where applicable, test/service date, assigned cylinder and repair history.
Before procurement, ask whether service and replacement seals, gauges, relief valves and other parts are available in Nigeria. Confirm warranty period, service location, response time, inspection requirement and whether the regulator is repairable or must be replaced. Do not infer local support or regulatory authorization from an international manufacturer listing. Franance can state what is included in its quote; the supplier or manufacturer should confirm technical support and spare-part terms for the exact model.
Send Franance the exact model number, quantity and delivery destination. State the cylinder brand and model, permanent valve connection, service pressure, current test status and regulator pressure requirement. For Drive 18302GDEL, specify the DISS outlet and any compatible humidifier connection. For Drive 18302GMN, specify the barb outlet and the downstream tubing or accessory. For GCE 0720223, specify the pin-index oxygen inlet, 9/16 outlet, 0–25 L/min requirement and confirmation of the 200 bar configuration.
Ask the quote to itemize the regulator, cylinder if required, valve or adapter, outlet connector, humidifier, tubing, carrying case or trolley, protective caps, inspection or calibration, installation, staff training, delivery, warranty, service and spare parts. Request current instructions, product data, conformity documents required by your procurement policy, and written confirmation of the complete cylinder-to-regulator-to-device compatibility. Include the intended facility department, city, quantity, purchasing schedule and any required delivery or service support.
Do not assume that a pictured cylinder, humidifier, tubing, regulator accessory or adapter is bundled. Ask Franance to distinguish supplied items from components that must be sourced separately. Confirm stock status, lead time, quote validity, payment terms and after-sales service in writing. For an established fleet, include the current regulator model and connector standard so that replacements do not create incompatible mixtures at the point of care.
Franance accepts quote orders for catalogue products; there is no online checkout. Select the model that matches the documented inlet, pressure and outlet needs, then send your cylinder and downstream equipment details with the quote request. Franance will contact you by phone or email to clarify the configuration and commercial terms. Do not approve a regulator based on flow range alone. Confirm the exact valve, cylinder pressure, outlet connection and included accessories in writing before purchase.
For a facility-wide requirement, make a schedule of cylinders, valve types, regulator models, required flow settings and outlet accessories by department. Have clinical engineering or the medical-gas team verify the schedule, and ask Franance to quote only validated combinations. Browse all oxygen cylinder regulators listed by Franance or request an oxygen regulator quotation.
Browse Franance’s oxygen regulator category and submit a quote order with the exact model, cylinder valve and pressure, outlet configuration, quantity and destination. Franance follows up by phone or email; there is no online checkout.
The current category assigns Drive 18302GDEL CGA870/DISS, Drive 18302GMN CGA870/barb, and GCE MEDISELECT II 0720223 pin-index/9/16. Confirm the exact item in the quote.
Both are 0–15 LPM regulators with CGA870 inlet. The GDEL is elongated with DISS outlet; the GMN is a mini model with barb outlet.
The exact article 0720223 is listed by GCE at 200 bar. The broader MEDISELECT II family has other pressure variants; check the exact article label and current instructions.
No. They are different inlet systems. Verify the exact cylinder valve and regulator inlet, and do not use an unapproved adapter.
The assigned catalogue records are regulators. Ask Franance to itemize cylinders and all accessories and confirm the full compatibility chain.
No. A flow selector is an equipment setting. Clinical staff determine the required prescription and monitoring.
No. Franance accepts quotation requests and contacts the requester by phone or email.
Send the cylinder valve and pressure, regulator model, outlet requirements, quantity and Nigerian destination. Franance will follow up by phone or email to clarify your quote order.
Request an oxygen regulator quoteAdd the models you need to a quote order, or send us your equipment list.