
Buy X-Ray Collimator in Nigeria.
Buy X-ray collimators in Nigeria through Franance by identifying the radiography system, tube assembly, field requirements and exact mechanical and electrical interfaces before requesting a quotation. The current category lists Siemens Healthineers ML 03 and Shimadzu R-20J manual collimators. These are components, not complete X-ray systems; check the exact model-specific documentation and compatibility for the proposed configuration. Franance accepts quote orders and follows up by phone or email, with no online checkout.
Products
2 models


Where can I buy an X-ray collimator in Nigeria?
Start with Franance’s X-ray collimator category. Its current catalogue contains two model references: the Siemens Healthineers ML 03 and the Shimadzu R-20J. Review the model information, then send Franance an enquiry with the installed or proposed X-ray system and the configuration you need. A listing is a starting point for a quote request; it does not confirm current stock, Nigerian availability or compatibility with your equipment.
Read moreWhich X-ray collimators are listed by Franance?
The Siemens Healthineers ML 03 is identified by Siemens as a manual X-ray collimator for radiography. Siemens describes its design as modular and lists a long-life, high-brightness LED. The manufacturer explains collimation as shaping the radiation beam emerging from the X-ray tube assembly to the size of the object being displayed. Siemens also describes a wider collimator portfolio for radiographic, fluoroscopic, vascular and cardiovascular applications; those broader applications should not be assumed to describe this particular ML 03 model.
Read moreWhat does an X-ray collimator do?
An X-ray collimator is positioned at the X-ray tube assembly and limits or shapes the beam used for an exposure. Its field is set to correspond to the object or detector area intended for the examination. This makes the collimator an integrated system component: its mechanical fit, controls, light field, power connections and alignment need to be considered with the particular tube assembly and X-ray system. The equipment documentation and qualified engineering team determine the correct configuration and checks.
Read moreBuy X-ray collimators in Nigeria
Buy an X-ray collimator in Nigeria through Franance by identifying the radiography system it must fit, the required field coverage and the exact mechanical and electrical interfaces. The current Franance category lists the Siemens Healthineers ML 03 manual X-ray collimator and Shimadzu R-20J manual collimator. These are collimator components, not complete X-ray systems. Send the tube assembly and system references, field and source-to-image distance requirements, mounting details, quantity and facility destination so Franance can request a quotation for the correct configuration. Franance follows up by phone or email; there is no online checkout.
Where can I buy an X-ray collimator in Nigeria?
Start with Franance’s X-ray collimator category. Its current catalogue contains two model references: the Siemens Healthineers ML 03 and the Shimadzu R-20J. Review the model information, then send Franance an enquiry with the installed or proposed X-ray system and the configuration you need. A listing is a starting point for a quote request; it does not confirm current stock, Nigerian availability or compatibility with your equipment.
For an existing room, include the X-ray system manufacturer, system model and serial number, tube assembly and current collimator references. For a new installation, state the proposed generator, tube support and tube assembly configuration, and share the system specification or room project document. Include the hospital or clinic’s city and state, number of units, preferred project timing and whether the request includes installation or engineering review. Franance will contact you by phone or email to clarify the quote order. Confirm the item, configuration, price, delivery, warranty and service terms in writing before placing an order.
Which X-ray collimators are listed by Franance?
The Siemens Healthineers ML 03 is identified by Siemens as a manual X-ray collimator for radiography. Siemens describes its design as modular and lists a long-life, high-brightness LED. The manufacturer explains collimation as shaping the radiation beam emerging from the X-ray tube assembly to the size of the object being displayed. Siemens also describes a wider collimator portfolio for radiographic, fluoroscopic, vascular and cardiovascular applications; those broader applications should not be assumed to describe this particular ML 03 model.
The Shimadzu R-20J is a manual collimator. Shimadzu’s RADspeed Pro style edition manual brochure lists a maximum irradiation field of 430 × 430 mm at a 100 cm source-to-image distance (SID), a light switch with automatic off function, accessory rails and an LED lamp. These are published brochure details; they do not by themselves confirm fit with another manufacturer’s tube assembly or room.
The category currently lists these two catalogue items. It is not a complete directory of every collimator model or option made by either manufacturer. Use the exact filtered listing and the manufacturer's current documentation to identify a candidate, then ask for a written compatibility review. Do not infer that the ML 03 and R-20J have identical fields, mounting, connectors or controls simply because both are manual X-ray collimators.
What does an X-ray collimator do?
An X-ray collimator is positioned at the X-ray tube assembly and limits or shapes the beam used for an exposure. Its field is set to correspond to the object or detector area intended for the examination. This makes the collimator an integrated system component: its mechanical fit, controls, light field, power connections and alignment need to be considered with the particular tube assembly and X-ray system. The equipment documentation and qualified engineering team determine the correct configuration and checks.
A collimator is not the X-ray tube, tube housing, high-voltage generator, exposure control, patient table, wall stand or digital detector. It does not independently create an image or turn a component into a complete radiography system. If your project concerns a full room, specify each part separately or request an integrated proposal that identifies the exact models and interfaces. Franance has separate listings for X-ray tubes, X-ray tube assemblies, X-ray generators, radiography wall stands, and DR detector panels.
For procurement, distinguish the part being replaced from the larger assembly around it. A service note may identify a collimator while a quotation could require additional parts or technical work. Ask the supplier to list what is included, what is excluded and what must be verified onsite. No generic product description should be treated as a substitute for the device’s manufacturer instructions.
How do I choose a collimator for an X-ray system?
Start with the installed tube assembly and system, not an isolated product image or a brand name. Record the X-ray system make, model and serial; tube assembly make, model and part number; current collimator model; and any system configuration or service references available to your biomedical team. If the collimator is missing or its identification plate cannot be read, share that uncertainty and ask the manufacturer or qualified imaging engineer to identify the required replacement before purchase.
Next, document the required field range and operating geometry from the system specification. Note the SID or range of distances used by the configured system, the field dimensions needed, and any project-defined indication or control requirements. The R-20J brochure’s stated maximum field is specifically tied to 100 cm SID. Do not extend that figure to other distances or assume that the ML 03 shares it; request the exact model datasheet and application-specific specification for the offered item.
Confirm mounting and interfaces. Ask for the mechanical attachment or flange dimensions, clearance, orientation, cable and connector details, electrical supply and control compatibility, and any tube-housing restrictions. Check the light-field function and whether its illumination controls or automatic switch-off behavior match the expected configuration. If accessory rails are required, identify the accessories and their interface; Shimadzu lists rails for R-20J, but that does not establish compatibility with every accessory.
Finally, have the system manufacturer or a qualified imaging integrator confirm the complete match. Request a model-specific statement or configuration schedule that identifies the collimator, tube assembly, system, required accessories and any installation or alignment work. A component that can be mounted physically is not necessarily the correct electrical, optical or approved configuration. Do not modify, install or adjust radiation equipment based only on this guide; follow the applicable manufacturer instructions and qualified service process.
Buy Siemens Healthineers ML 03 manual X-ray collimators in Nigeria
The Siemens Healthineers ML 03 catalogue entry identifies the item as a manual X-ray collimator for radiography. Siemens describes a modular design and a long-life LED with high brightness. Its page explains that collimation shapes the beam from the X-ray tube assembly to the size of the object being displayed. The manufacturer also offers a downloadable ML03 product datasheet on the official X-ray Collimators page.
When requesting a quote, provide the existing or proposed system and tube assembly identifiers, collimator reference, mounting interface, electrical connection, required field and SID, and any required accessories. Ask Franance to identify the exact ML 03 configuration being offered and provide the current model-specific documentation needed for your technical review. Siemens’ page describes OEM integration in broad terms; it does not establish that an ML 03 will fit an arbitrary third-party system or a particular room. Compatibility must be confirmed for the actual equipment and configuration.
Buy Shimadzu R-20J manual X-ray collimators in Nigeria
The Shimadzu R-20J catalogue entry is a manual collimator. Shimadzu’s official RADspeed Pro style edition manual brochure lists a maximum 430 × 430 mm irradiation field at 100 cm SID, a light switch with automatic off function, accessory rails and an LED lamp. The brochure presents the collimator as a component in a broader radiography system range; the listing does not mean that the complete system or every pictured component is included in the R-20J quote.
Give Franance the tube assembly and room/system references, the field and SID requirements, the relevant mounting and electrical interfaces, accessory needs, quantity and destination. Ask the quotation to state whether the exact R-20J item is proposed, what it includes, and which compatibility checks or installation tasks are in scope. The Shimadzu brochure notes that configuration and options may vary by country; it does not establish Nigerian availability, price, delivery, warranty or service for a quote order. Confirm all commercial and technical details in the written offer.
What details should I provide for compatibility checking?
Send the information as a short equipment schedule rather than relying on a general request for “an X-ray collimator.” Include:
- X-ray system manufacturer, model, serial number and configuration.
- Tube assembly and tube housing manufacturer, model, serial and part references.
- Existing collimator manufacturer, model, part number and reason for replacement.
- Required field size, SID or operating distances, and specification source.
- Mechanical mounting dimensions or interface drawing, orientation and clearance.
- Electrical supply, cable/connector and control-interface details available to the facility.
- Any accessory rail attachments or other required options, named by model if known.
- Quantity, facility city and state in Nigeria, delivery access and project scope.
- Whether the request is for supply only, a compatibility review, installation or other engineering work.
Include photos of labels or installation context only when the facility permits it and no patient-identifying information is visible. Share relevant manuals or service documents with the authorized technical team. Ask the manufacturer or qualified imaging engineer to confirm the proposed item against the exact system revision. If key details are missing, ask what evidence is needed before selecting a part. Do not use a family-level product page to fill gaps in a specific installation’s technical record.
What should an X-ray collimator quotation in Nigeria include?
Ask for a written quotation that identifies the brand, exact model, part number or configuration, description and quantity. It should specify included components and accessories, relevant interfaces and the basis for compatibility with the tube assembly and system. If compatibility is not yet confirmed, the offer should identify the outstanding check or required site information rather than implying that the component is ready to install.
Request separate lines for the collimator, delivery, technical review, installation, system integration, alignment or acceptance work, and any other requested service. Ask who performs each activity and which manufacturer documents are provided. Confirm applicable regulatory and conformity documentation for the specific item through the supplier and your facility’s procurement process; this guide does not make a certification or approval claim.
The commercial section should state the quoted price and currency, taxes or other charges, quote validity, payment terms and delivery conditions. Ask the supplier to state availability and expected timing, warranty period and scope, exclusions, and the route for service support. These facts vary by the specific offer and are not established by a manufacturer brochure or the presence of an item in a catalogue. Franance accepts quote orders rather than online payment and follows up by phone or email. Review the written terms before confirming an order.
How do I request a Franance X-ray collimator quote?
Open the X-ray collimator category and select the relevant Siemens Healthineers ML 03 or Shimadzu R-20J reference. Then send Franance a quotation enquiry with the equipment identifiers, field and SID requirements, mounting and connection details, quantity, destination and requested technical scope.
Franance will follow up by phone or email to clarify the request and quotation. This is a quote order, not an online purchase. Before accepting the offer, have your technical and procurement teams review the exact item, compatibility basis, supply scope, commercial terms, delivery, warranty and service responsibilities. Ask for any assumptions, substitutions or conditions to be stated in the final written quotation.
Sources and limits of this guide
The Siemens Healthineers X-ray Collimators page identifies ML 03 as a manual collimator for radiography and describes selected design and LED features. Shimadzu’s RADspeed Pro style edition manual brochure lists the R-20J field and other component details. Shimadzu’s official medical-device information booklet lists Collimator Type R-20J as a named product. Sources reviewed 21 October 2026.
Manufacturer material supports the identities and specific features stated above, but does not confirm the exact configuration offered by Franance, compatibility with an installed system, Nigerian availability, price, stock, delivery date, warranty, regulatory status, local service or installation scope. Confirm those details in the current model-specific documentation and written quotation. This guide is procurement information; it is not an engineering design, clinical protocol, radiation-safety assessment, compatibility approval or installation instruction.
Common questions
Where can I buy an X-ray collimator in Nigeria?
Review Franance's X-ray collimator category and request a quotation with the X-ray system and tube assembly make, model and serial, existing collimator reference, field and SID requirements, interfaces, quantity and facility destination. Franance follows up by phone or email; the listing does not confirm stock or compatibility.
Which X-ray collimators are listed by Franance?
The current category lists the Siemens Healthineers ML 03 manual X-ray collimator and Shimadzu R-20J manual collimator. Confirm the exact configuration and system fit with current model-specific manufacturer documentation.
What is the maximum field listed for the Shimadzu R-20J?
Shimadzu's RADspeed Pro style edition manual brochure lists a maximum 430 × 430 mm irradiation field at 100 cm SID. This is a model brochure value at the stated distance, not an ML 03 specification or a field-size confirmation for another setup.
Will either collimator fit any X-ray tube?
No universal compatibility is implied. Confirm the exact tube assembly, mounting, electrical and control interfaces, field requirements and system configuration with the manufacturer or a qualified imaging integrator.
Can I pay online for an X-ray collimator?
No. Franance handles quote orders rather than online checkout and follows up by phone or email to clarify the item, configuration and quotation terms.
Request an X-ray collimator quotation in Nigeria.
Send the system and tube assembly identifiers, existing collimator reference, field and SID requirements, mounting and interface details, accessory needs, quantity, facility destination and requested engineering scope. Ask the written offer to name the exact model, compatibility basis, included components, price, availability, delivery, warranty and service responsibilities. Franance will follow up by phone or email; this is a quote order, not an online purchase.
Request an X-ray collimator quoteNeed an equipment quote?
Add the models you need to a quote order, or send us your equipment list.

