Buy Radiography Patient Table in Nigeria.

Buy a radiography patient table in Nigeria through Franance by matching the table, Bucky assembly, image receptor and X-ray tube support to the examinations and room you plan to run. This category currently lists Siemens Healthineers Radiographic Table and Shimadzu BK-200 references. They are table components, not complete X-ray rooms. Compare the exact model and documented configuration. Franance accepts quote orders and follows up by phone or email; catalogue listings do not confirm stock, price or compatibility.

Where can I buy a radiography patient table in Nigeria?

Start with Franance's radiography patient table category, which currently lists the Siemens Healthineers radiographic Bucky table and Shimadzu BK-200. Review the catalogue references, then send Franance a quote order with the exact requirement and facility destination. A listing identifies a quote-enquiry item; it does not promise current availability, a final configuration or approval for use with a particular X-ray system.

Read more

Which radiography patient tables are listed?

There are two directly assigned products in this category at the time of review. The Siemens Healthineers entry is a configurable radiographic table family rather than a named model code in the Franance record. Siemens describes floating tabletops, height adjustment, a Bucky with stationary or moving grid, and DR, CR and screen-film cassette workflows. The product-family page lists table height from 54 cm to 93 cm, patient weight capacity up to 280 kg, coverage up to 190 cm without repositioning, and tabletop-to-film distance below 55 mm. These are family-page values; confirm them against the exact table and current data sheet in the proposed quotation.

Read more

What does a radiography patient table do?

A radiography patient table supports a patient horizontally and provides a tabletop and positioning mechanism for table-based X-ray examinations. A Bucky table incorporates or works with an image-receptor assembly beneath the tabletop; the selected system may use a digital detector, computed-radiography cassette or another specified receptor workflow. Table movement, Bucky position, grid and the relationship to the X-ray tube must fit the intended examinations and the rest of the room system.

Read more

Buy radiography patient tables in Nigeria

Buy a radiography patient table in Nigeria through Franance by matching the table, Bucky assembly, image receptor and X-ray tube support to the examinations and room you plan to run. The current Franance category has two directly assigned references: the Siemens Healthineers Radiographic Table family and the Shimadzu BK-200 Bucky table. Both are patient-table components for general radiography, not complete X-ray rooms. The manufacturers describe different configuration choices, movement and load values, so compare the exact table and its documented configuration instead of treating “Bucky table” as one universal specification. Franance accepts quote orders and follows up by phone or email. The catalogue is not an online checkout and does not establish stock, a final price or compatibility.

Where can I buy a radiography patient table in Nigeria?

Start with Franance's radiography patient table category, which currently lists the Siemens Healthineers radiographic Bucky table and Shimadzu BK-200. Review the catalogue references, then send Franance a quote order with the exact requirement and facility destination. A listing identifies a quote-enquiry item; it does not promise current availability, a final configuration or approval for use with a particular X-ray system.

For a useful response, say whether the enquiry is for a replacement table, a new X-ray room or a broader radiography project. Identify the installed or proposed system's manufacturer, model and serial number, plus the tube support, detector or cassette workflow and any existing table interface. Include the facility city and state, quantity, room information, and requested site or installation scope. Franance can follow up by phone or email to clarify the enquiry and provide a written quotation for review.

Which radiography patient tables are listed?

There are two directly assigned products in this category at the time of review. The Siemens Healthineers entry is a configurable radiographic table family rather than a named model code in the Franance record. Siemens describes floating tabletops, height adjustment, a Bucky with stationary or moving grid, and DR, CR and screen-film cassette workflows. The product-family page lists table height from 54 cm to 93 cm, patient weight capacity up to 280 kg, coverage up to 190 cm without repositioning, and tabletop-to-film distance below 55 mm. These are family-page values; confirm them against the exact table and current data sheet in the proposed quotation.

The second entry is Shimadzu BK-200, identified in a RADspeed Pro manual brochure as a heavy-duty Bucky table. The brochure lists a 535–850 mm height range, maximum lifting weight of 295 kg, tabletop floating travel of 1,150 mm longitudinally and 250 mm transversely, Bucky-unit travel of 400 mm, a removable grid, and an optional flat-panel-detector (FPD) rotation tray. It also states that vertical movement is not synchronized with the CH-200M ceiling tube support in the documented manual configuration. Confirm the exact system and options in the quotation.

These are the products assigned to this leaf, not every table either manufacturer may offer in other markets or configurations. Open the Siemens filtered listing or the Shimadzu BK-200 filtered listing to inspect those references. The wider X-ray and digital radiography category also includes separate detector, wall-stand, generator and system categories.

What does a radiography patient table do?

A radiography patient table supports a patient horizontally and provides a tabletop and positioning mechanism for table-based X-ray examinations. A Bucky table incorporates or works with an image-receptor assembly beneath the tabletop; the selected system may use a digital detector, computed-radiography cassette or another specified receptor workflow. Table movement, Bucky position, grid and the relationship to the X-ray tube must fit the intended examinations and the rest of the room system.

The table is only one component. A general radiography room may also require an X-ray tube and support, generator, collimator, receptor or cassette and reader, acquisition workstation, controls, room infrastructure and integration. A table description does not tell you which of those other items are included. If you need a complete room, ask the quotation to identify every proposed component and the system boundary rather than reading a table listing as a complete system package.

How should I compare table height and patient-load specifications?

Start with access and transfer needs defined by the clinical and facilities teams. Compare the table's stated minimum and maximum heights, adjustment method, movement controls, patient approach, trolley transfer route and the space available around the table. A low position may support a facility's transfer workflow, but the appropriate range depends on its procedures, staff practices and the selected system. Do not infer a clinical or accessibility outcome from one height figure.

Read load terminology carefully. Siemens describes “high patient weight capacity” up to 280 kg for its table family. Shimadzu's BK-200 brochure states “maximum lifting weight” of 295 kg. These source-specific terms are not interchangeable guaranteed patient ratings for every configuration. Ask the manufacturer or supplier to confirm the permitted patient load for the exact table and applicable documentation. Confirm any load-distribution assumptions or other limits in writing; do not infer them from a brochure summary.

Check whether the table has fixed or adjustable height, its movement range, how movement is controlled, and whether automatic or synchronized functions are part of the proposed configuration. Identify if the table needs to lower for transfer, hold a defined position, or coordinate with the tube support. The imaging and technical teams should compare these requirements with current documentation for the exact configuration.

Buy Siemens Healthineers radiographic Bucky tables in Nigeria

Siemens Healthineers describes its radiographic tables as height-adjustable Bucky tables with four-way low-force tabletop movement. Its product-family page identifies a floating tabletop and height adjustment, a table height range of 54–93 cm, and support for DR, CR and screen-film cassettes. It lists patient weight capacity up to 280 kg, coverage up to 190 cm without repositioning, tabletop-to-film distance below 55 mm, flat tabletop availability, stationary or moving grid options, manual versions and automatic cassette-size-sensing variants. Siemens says the tables are prepared for its 3D V ceiling stands.

This is a family-level page, not confirmation of which model or option is included in a Franance quote. Request the current data sheet and exact model or configuration. Confirm the height-adjustment range, tabletop travel, grid and Bucky arrangement, cassette-size sensing, receptor workflow, tube support and system interface. Ask the supplier to identify every option, accessory and exclusion. Do not assume that all features described on the family page are included in one offered table.

Open the Siemens Healthineers table listing. For a quote request, give Franance the host X-ray system make, model and serial, planned DR or CR receptor, required load rating, table movements and room interface. The official Siemens radiographic-table page supports family-level product facts; it does not establish Nigerian availability, price, lead time, installation, warranty or fit with an unrelated system.

Buy Shimadzu BK-200 Bucky tables in Nigeria

Shimadzu identifies the BK-200 as a heavy-duty Bucky table in its RADspeed Pro manual brochure. The published table values are a 535–850 mm height range, maximum lifting weight of 295 kg, tabletop floating travel of 1,150 mm longitudinally and 250 mm transversely, and Bucky-unit travel of 400 mm. The brochure says the grid is removable and an FPD rotation tray is optional. It also explicitly notes that vertical movement is not synchronized with the CH-200M in that manual configuration. Confirm current documentation and the exact system configuration before using these values as a purchase specification.

Shimadzu presents BK-200 alongside, but separately from, the CH-200M tube support and BR-120M Bucky stand. Ask the supplier to state whether the quote covers the table alone or a broader RADspeed Pro configuration, and which tube support, detector, generator, wall stand and options are included. If synchronization, Bucky tracking or a rotation tray matters to the project, state this explicitly and request written confirmation that the function is supported in the proposed combination. The general brochure does not prove compatibility with another manufacturer's equipment.

Review the Shimadzu BK-200 filtered listing and the official RADspeed Pro manual brochure. The manufacturer notes that specifications may change, components shown may include options, and configurations may not be available in every country. The brochure does not confirm Nigerian stock or the commercial terms of a transaction.

How do tabletop travel and Bucky movement affect selection?

Tabletop travel and Bucky movement describe different positioning ranges. A floating tabletop allows staff to move a patient's position relative to the receptor and X-ray field without lifting the patient. Bucky-unit travel shifts the receptor assembly relative to the tabletop. The directions and amounts matter: longitudinal travel runs along the table, while transverse travel runs across it. A larger published range alone does not establish better suitability. Compare the required examinations, positioning workflow, system geometry and the manufacturer's measurement basis.

For BK-200, Shimadzu lists 1,150 mm longitudinal and 250 mm transverse floating range, and 400 mm Bucky-unit movement. For Siemens, the public family page describes a four-way floating tabletop and coverage up to 190 cm without repositioning; request the exact data sheet for specific movement values. Do not compare a coverage length with tabletop travel as though they were the same specification.

Ask the technical team to map required movement to tube positions, source-to-image distance, detector formats, patient access and room layout. If a function depends on a matching tube support or optional tracking equipment, require the exact configuration and compatibility evidence. Manufacturer room-planning tools can help explore a rough arrangement, but do not replace technical review. Shimadzu says its room planner is for reference, cannot guarantee full accuracy and may not represent all system postures or potential collisions.

How do I confirm DR, CR, grid and X-ray system compatibility?

Write down the exact receptor workflow before comparing tables. For digital radiography, provide the detector manufacturer, model, dimensions and intended holder or tray. For computed radiography, identify cassette dimensions, reader, and how the cassette will be loaded and positioned. Include whether the room uses a fixed or moving grid, the required grid specification, cassette-size sensing and detector rotation. A manufacturer's statement that a family supports broad receptor classes does not mean every detector, cassette or grid fits every variant.

Identify the X-ray tube support and its positioning or tracking arrangement, generator and acquisition system. Ask the manufacturer or qualified system integrator to confirm the table, Bucky, detector, grid, tube support and controls as an intended configuration. If existing equipment is retained, include model names, serial numbers and available configuration references. State which parts are new, retained or outside the quote. A shared brand name or matching product family does not substitute for specific compatibility confirmation.

Use the separate radiography wall stand and Bucky category, X-ray generator category and DR detector panel category if the project requires those components. If you request a system rather than a table, ask Franance to itemize each proposed component and state who is responsible for integration and interface confirmation.

What room details should I prepare for a table quotation?

Provide an accurate room plan or measured dimensions for the table, patient-transfer route, staff access, tube support and wall stand. Note ceiling height, clearance around and beneath the table, floor construction and any lift, doorway or delivery-access constraints. Identify room use, control-area location, and whether a trolley or wheelchair needs access. Facility engineers and the equipment manufacturer or qualified integrator should assess mounting, clearances, electrical work and layout.

For an existing room, include the radiography system make, model and serial, tube support, generator, detector or cassette, and any table or Bucky reference. Describe what will be replaced and which components must remain. For a new room or renovation, state whether you request a site survey, layout review, installation, system integration, commissioning, acceptance testing or user training. Keep the supplier's responsibilities separate from building work and tasks assigned to the facility or other contractors.

Shimadzu's room-planner notes state that its tool is a rough reference and cannot guarantee accuracy; actual postures and potential collisions may not be represented. Do not treat a virtual layout or a guide as engineering approval. Request a site-specific review of the exact configuration and room before finalizing installation planning.

What should a radiography patient table quotation include?

Ask for manufacturer, exact model or product-family variant, table configuration, quantity and condition. The offer should state the height range, the manufacturer's applicable patient-load or lifting-capacity rating, tabletop movement, Bucky travel, grid, cassette or detector interface, and all options and accessories. For Shimadzu BK-200, ask whether an FPD rotation tray is included or optional and how tube-support movement is configured. For Siemens, request the model-specific data sheet and identify which features from the family page are part of the proposed unit.

The quotation should explain compatibility with the existing or proposed tube support, generator, detector or CR workflow and acquisition system. Ask the supplier to document the basis for compatibility and list unresolved interfaces. It should separate the table from any wall stand, tube support, detector, generator, workstation and installation work. Request applicable technical and regulatory documents for the specific offer; do not infer regulatory status from a product brochure.

Ask the written offer to state price and currency, taxes and charges, validity, payment terms, delivery destination and terms, expected lead time, installation scope, acceptance responsibilities, warranty duration and exclusions, and support arrangements. Franance handles quote orders and contacts customers by phone or email. No online purchase is completed through the catalogue. Availability and final price are confirmed only in the actual written quotation.

What does a radiography patient table cost in Nigeria?

There is no verified public price in this category. Cost depends on the exact model, configuration, options, other system components, site requirements, delivery and service scope. The Siemens record is a product family rather than one fixed model; BK-200 may be offered as a component or within a larger system proposal. Do not infer the quotation from manufacturer specifications or a product image.

To request a useful estimate, include model preference, required height and load specification, movement, detector or cassette workflow, grid, existing system details, quantity, site location and requested installation or acceptance services. Ask Franance for a dated quotation that identifies assumptions, excluded items, taxes, delivery and validity. Confirm final terms directly before placing an order.

How do I request a Franance quotation?

Open the radiography patient table category, choose the Siemens Healthineers table reference or Shimadzu BK-200 reference, then submit a radiography patient table quote request. Include equipment and room information, facility city and state, quantity, contact details and requested project scope.

Franance will follow up by phone or email to clarify the request. Before accepting a proposal, check the exact configuration and compatibility, component boundaries, installation responsibilities and commercial terms. Ask that substitutions, exclusions and unresolved technical details appear in writing. This process is an enquiry followed by a quotation, not online payment or confirmation of stock.

Manufacturer sources and limits

Siemens Healthineers' Radiographic Tables product-family page provides the family-level features and values summarized above. Shimadzu's RADspeed Pro manual brochure identifies BK-200 and lists its specifications, options and relationship to the manual tube-support configuration. Shimadzu's Room Planner remarks describe limitations of its planning tool. The WHO user guide for technical specifications for medical devices explains that technical specifications support medical-equipment tendering and procurement.

Manufacturer literature describes product facts and options; it does not prove Nigerian availability, stock, price, delivery, warranty, installation, local support, regulatory status of the offered system or compatibility with a facility's equipment. Specifications may vary by variant, option, site or market. Have the manufacturer or qualified imaging integrator confirm the exact table and system. This guide supports procurement planning; it is not clinical advice, room design, radiation-safety approval, compatibility certification or installation instruction.

Common questions

Does the 295 kg BK-200 maximum lifting weight mean every configuration has a 295 kg patient rating?

The Shimadzu brochure calls 295 kg the maximum lifting weight. Confirm the applicable permitted patient load for the exact table and configuration in current manufacturer documentation; do not assume those terms are interchangeable.

Are the Siemens table features listed for every variant?

No. Siemens describes a product family with options and variants. Request the exact model and data sheet, and have the supplier identify which height, grid, receptor and sensing features are included in the offer.

Does Shimadzu BK-200 include synchronized movement with every tube support?

No. The manual brochure states that vertical movement is not synchronized with the CH-200M in the described configuration. Confirm synchronization or tracking requirements for the exact system and configuration in writing.

Can I buy a radiography patient table online from Franance?

No. Franance accepts quote orders and follows up by phone or email. Submit the equipment, room and destination requirements, then review the written quotation and its terms.