Buy Bedhead Unit (BHU) in Nigeria.

Buy bedhead units (BHU) in Nigeria through Franance by preparing the bed-space design and service schedule before requesting a quote. The current category lists Amico Majestic single-tier recessed headwall, a BeaconMedaes patient bedhead example with DIN-style GEM Shield terminals, and Dräger Prana configurable bed-head unit. These are project-configured assemblies, not direct substitutes. Send room elevations, wall and mounting details, gas/vacuum terminal schedule, electrical/data/lighting requirements, quantity and Nigerian destination. Franance follows up by phone or email; online payment is not available.

Products

3 models

Filter all 3 products

Which bedhead units can I buy in Nigeria?

The current Bedhead Unit (BHU) category contains three distinct catalogue records: Amico Majestic Series Single Tier Recessed Headwall, BeaconMedaes Patient Bedhead Unit with DIN-Style GEM Shield Terminals, and Dräger Prana Bed-Head Unit. Each brand/category/model filter returns its matching current product. The catalogue filters help identify the record; they do not establish a completed design, compatible gas outlet, or site-specific approval.

Read more

What does a bedhead unit include?

A bedhead unit, bed-head unit, headwall or medical supply unit is a patient-area enclosure or assembly for services positioned near a bed. Depending on the manufacturer and selected configuration, it may provide places for gas-specific pipeline terminal units, vacuum, power receptacles, communication/data, task or room lighting, and accessory rails. The product names do not mean that every service is included in every quoted unit. Confirm each intended function and interface in the project-specific bill of quantities and shop drawing.

Read more

How do the three listed bedhead options differ?

Amico Majestic single-tier recessed headwall. Amico describes this as a horizontal headwall designed to mount flush with the wall. Its published single-tier recessed specification describes a modular enclosure and length options from 12 to 120 inches (305 to 3,048 mm). It also describes a frame supporting medical-gas piping and a single-point connection arrangement, removable fascia, accessory channels and coordinated service provisions. Treat the published dimensions and component language as manufacturer-specific information for the referenced product sheet; the signed project drawings and current regional technical documents determine the actual configuration. Amico also says medical gas outlet connection type is selected in approved documents. The US-specific electrical and code references in the spec are not evidence of Nigerian installation approval.

Read more

Buy Bedhead Unit (BHU) in Nigeria

Franance lists three bedhead service-unit options for quotation in Nigeria: the Amico Majestic Series Single Tier Recessed Headwall, BeaconMedaes Patient Bedhead Unit with a DIN-style GEM Shield terminal example, and Dräger Prana configurable bed-head unit. These are project-configured room-service assemblies, not interchangeable fixed-SKU devices. To request a quote, provide a bed-space drawing, wall and mounting details, service outlet schedule, local gas-terminal standard, electrical/data and lighting requirements, and delivery location. Franance follows up by phone or email; the site does not take online payment.

Which bedhead units can I buy in Nigeria?

The current Bedhead Unit (BHU) category contains three distinct catalogue records: Amico Majestic Series Single Tier Recessed Headwall, BeaconMedaes Patient Bedhead Unit with DIN-Style GEM Shield Terminals, and Dräger Prana Bed-Head Unit. Each brand/category/model filter returns its matching current product. The catalogue filters help identify the record; they do not establish a completed design, compatible gas outlet, or site-specific approval.

All three offerings are wall-mounted bedhead or patient-room service units that can consolidate some combination of medical-gas terminals, electrical services, lighting, communication/data and accessory mounting. Their exact layouts differ. The Amico listing names a recessed single-tier horizontal headwall; the BeaconMedaes listing is a configured patient bedhead example with DIN-style GEM Shield terminals and no fixed model code in the reviewed source; Dräger Prana is a configurable family available in single- and double-duct arrangements. Project documents and manufacturer submittals determine the final configuration.

What does a bedhead unit include?

A bedhead unit, bed-head unit, headwall or medical supply unit is a patient-area enclosure or assembly for services positioned near a bed. Depending on the manufacturer and selected configuration, it may provide places for gas-specific pipeline terminal units, vacuum, power receptacles, communication/data, task or room lighting, and accessory rails. The product names do not mean that every service is included in every quoted unit. Confirm each intended function and interface in the project-specific bill of quantities and shop drawing.

The unit is also not the entire medical-gas pipeline system. NHS England's Health Technical Memorandum 02-01 describes the broader pipeline system and its design, installation, validation, verification and management. ISO 11197 applies to the basic safety and essential performance of medical supply units; ISO 9170-1 addresses terminal units for compressed medical gases and vacuum. These references help frame the conversations between the facility, designer, medical-gas installer and manufacturer. HTM is UK guidance, not Nigerian law, and citing an international standard does not certify any offered product or installation.

Distinguish the enclosure from its service components. A gas terminal must match the pipeline gas and the locally specified outlet connection. Electrical sockets and data modules require the appropriate power and IT design. Lighting, nurse-call, rails and accessories must be identified separately. Ask the manufacturer to state inclusions, exclusions and responsibility for each interface rather than assuming that a product-family image represents the delivered scope.

How do the three listed bedhead options differ?

Amico Majestic single-tier recessed headwall. Amico describes this as a horizontal headwall designed to mount flush with the wall. Its published single-tier recessed specification describes a modular enclosure and length options from 12 to 120 inches (305 to 3,048 mm). It also describes a frame supporting medical-gas piping and a single-point connection arrangement, removable fascia, accessory channels and coordinated service provisions. Treat the published dimensions and component language as manufacturer-specific information for the referenced product sheet; the signed project drawings and current regional technical documents determine the actual configuration. Amico also says medical gas outlet connection type is selected in approved documents. The US-specific electrical and code references in the spec are not evidence of Nigerian installation approval.

BeaconMedaes Patient Bedhead Unit with DIN-style GEM Shield terminals. The reviewed BeaconMedaes portfolio shows a patient bedhead unit example using a GEM Shield terminal in DIN style and describes a broader Bedhead Units & Lights family integrating services such as medical-gas outlets, lighting, data and accessory mounting. The catalogue entry is a configured example, not a fixed model-number product with a complete standard bill of materials. Confirm the exact gas outlet family and country standard, quantity, faceplates, electrical/data modules, light, rails, dimensions and wall-mounting details on the manufacturer's current quotation and drawings.

Dräger Prana bed-head unit. Dräger describes Prana as a modular wall supply unit family with single- and double-duct arrangements, configurable faceplates, and potential medical-gas, vacuum, power, IT and lighting options. The manufacturer's product information states that double-duct layouts can place a medical rail on one or both sides, with a central duct for media terminals; the compact single-duct arrangement has a different positioning of lighting, terminals and rail. The cited Prana S/W product-information sheet lists a maximum load of 5 kg on each medical rail and calls for at least 200 mm between gas terminal units for flammable or oxidizing gases and electrical outlets for the described variants. Confirm that these figures apply to the selected variant and current project drawing; do not extend them to another Prana layout, another manufacturer's unit or a local design without manufacturer and project-team review.

The three records are alternatives to assess at the design stage; they are not claims of direct substitution. A recessed headwall may require different wall construction and coordination than another bedhead arrangement. Their terminal standards, service modules, dimensions and documentation may differ. Do not compare them on appearance alone or assume a standard configuration from a product-family image.

How should I specify medical-gas outlets and terminal standards?

Prepare a service schedule that names each required gas or vacuum service at each bed position, the quantity, intended terminal-unit connection system, mounting side/height and applicable project standard. Include any requirements for other services only where the project team has specified them. Have the medical-gas designer and responsible pipeline installer reconcile this schedule against the existing or planned pipeline, system documentation and local requirements before procurement.

ISO 9170-1's published scope addresses gas-specific assembly, mechanical resistance, flow, leakage and pressure drop for terminal units used with compressed medical gases and vacuum, and aims to prevent interchange between different gases/services. This is why a terminal label or colour alone should not substitute for verifying the exact terminal interface and pipeline gas. Do not mix DIN, BS, Schrader, DISS, Ohmeda or other interfaces based on a general “medical gas outlet” description. The required outlet type is a project decision that must be confirmed in writing against the installed pipeline and connected equipment.

The BeaconMedaes catalogue record calls out a DIN-style GEM Shield terminal example, while Amico and Dräger list configurable product families rather than one universal connection set. That evidence does not prove that any of these terminal types are correct for your facility. Obtain a current terminal-unit schedule and confirm product references with the manufacturer and qualified medical-gas contractor before approving the order.

How do electrical, lighting and data services affect a BHU quote?

List normal and critical power needs, socket type and quantity, supply characteristics, data/network points, nurse-call interfaces, reading or examination light, indirect or night lighting, and any accessory rails or mounting points required by the design team. Specify whether modules are supplied, factory-installed, site-installed or provided by other trades. Identify any devices that must be fitted by the hospital IT, electrical or nurse-call contractor.

Amico's published Majestic specification separates components and contractor responsibilities in its project language, and Dräger presents a modular Prana arrangement with distinct terminal and lighting zones. These examples underline that a medical supply unit integrates coordinated services; they do not define one site's design. Facility electrical and IT teams should confirm local supply, grounding/bonding, critical circuits, device plug compatibility, isolation or backup requirements, network/security constraints and other applicable rules. Ask the manufacturer and project's licensed/qualified professionals to confirm compatibility and responsibilities. This guide does not provide an installation wiring design or assert compliance.

For rails and accessories, name the exact support rail type, length, location, accessory list and any load requirement. Dräger's product information provides a maximum load for the specified Prana rail configurations; verify the exact variant and mounting arrangement before specifying accessories. Do not transfer the manufacturer's value to Amico, BeaconMedaes or another rail system.

What room and wall information should be ready before ordering?

Provide architectural room elevations, bed-space plans, number of bed positions, wall construction and thickness, clear opening dimensions, mounting method, finished-floor datum, bed and trolley locations, and the proposed service centreline. Show nearby doors, windows, headboards, cabinets, medical equipment, lighting, ceiling systems and access paths. For recessed systems, confirm the cavity and framing arrangement against manufacturer drawings; for surface or wall-mounted units, clarify attachment structure and clearance.

Coordinate the headwall with medical-gas pipe routes and first-fix terminations, electrical conduits and circuits, data and nurse-call routes, lighting controls, and installation sequencing. Ask whether the selected model requires a support frame, single-point connection, separate service compartments or access panel. Such requirements vary by product and selected design. Do not begin cutting a finished wall from a catalogue picture or generic dimensional diagram.

The design team should issue coordinated shop drawings showing all terminal positions, power/data points, fascia, accessory channels and interfaces before manufacture. Include a clear process for approving revisions, documenting as-built conditions and resolving differences between existing site conditions and tender drawings. A headwall quotation cannot replace a site survey or establish that the facility's pipeline and electrical services are ready.

What should a Nigerian hospital include in the bedhead-unit quotation request?

For a Nigeria quotation, send the hospital/project name, delivery address, city and state, room type, number of bed spaces and required quantity. Attach dimensioned room elevations and wall details. Identify the preferred product/family and requested recessed, surface, single-tier, single-duct or double-duct layout as applicable. List every medical gas/vacuum terminal, connection standard, quantity, electrical/data point, lighting function, rail/accessory and finish requirement.

Ask the supplier to confirm the exact manufacturer product family and configuration code, if one exists; items included and excluded; current technical sheets and terminal schedule; length and dimensions; required wall opening and mounting frame; service interface and connection points; and required third-party works. For BeaconMedaes, explicitly ask for the fixed project model/part references because the catalogue record does not show a single ordering code. For all manufacturers, ask for project-specific drawings and a written configuration confirmation before manufacture.

The quote should also state unit pricing and currency, quote validity, taxes/duties, packing, freight and insurance, delivery terms to the Nigerian site, estimated production and transit timelines, warranty conditions and country-specific documentation. Request separate line items for design, site survey, installation, medical-gas connection, electrical/data connection, commissioning, pipeline validation/verification, training, maintenance and service if those are requested. Do not assume any of these are included with the wall unit. Franance's guide and catalogue do not establish local stock, authorization, installation capability, regulatory status, or lead time.

How should a bedhead project be coordinated and handed over?

Assign clear responsibility for the product submittal, room measurements, pipeline design, gas-terminal standard, electrical engineering, IT/nurse-call integration, installation, and inspection/testing. The facility should identify its local statutory and technical requirements and approve project drawings before fabrication. The manufacturer should confirm the exact unit and services; qualified local contractors should confirm what they install and test.

HTM 02-01 is published by NHS England as guidance for medical gas pipeline systems and covers design, installation, validation, verification and operational management in its jurisdiction. Use it as a technical reference only where the project team determines it is appropriate; it is not a Nigerian legal determination. ISO 9170-1 and ISO 11197 likewise provide scope references for terminal units and medical supply units. Ask the project's competent design and compliance professionals to identify the applicable Nigerian requirements and relevant current standards.

Handover documents should be agreed before order placement. Depending on the project scope, they may include approved shop drawings, exact outlet schedule and labels, manufacturers' instructions, electrical and gas connection documents, traceability, test/inspection reports, as-built plans, warranty documents and training records. The relevant project professionals—not a product title or supplier image—determine which records are necessary and whether the complete installation is ready for service.

What affects bedhead-unit price and delivery in Nigeria?

The cost depends on the exact manufacturer and configuration, unit length, room count, quantity and type of gas/vacuum outlets, electrical and data modules, lighting, rails/accessories, finishes, project-specific drawings, installation scope, shipping and destination. A recessed arrangement may involve different fabrication and wall-preparation requirements than another mounting solution. These are factors to disclose for a comparable quotation, not a price estimate.

Ask each supplier to quote against the same approved room schedule and drawings, and to identify the sales unit and every inclusion/exclusion. Compare like for like: same outlet standard and counts, same electrical/lighting/data scope, same rail and finish, same site services and same delivery terms. Confirm local availability and timeline in the current written offer; manufacturer websites and regional product pages do not prove Nigerian inventory or service.

Can I buy a bedhead unit online from Franance?

No. Franance handles quote orders and follows up by phone or email. The category listing does not offer online checkout or reserve a configured unit. Since these products depend on room and pipeline interfaces, send the design schedule and request a written project configuration and quotation before proceeding.

How do I request a bedhead unit quotation from Franance?

Browse the Bedhead Unit (BHU) category and review Amico Majestic, BeaconMedaes DIN-style GEM Shield bedhead example and Dräger Prana. Include the room elevations, wall details, bed positions, gas and vacuum terminal schedule, electrical/data/lighting needs, rail/accessory requirements, quantity and delivery city/state in your Franance Nigeria quotation enquiry.

Ask the project engineer and gas-system contractor to confirm the terminal standards and interfaces for the specific installation. Require manufacturer drawings and a written quote that names the selected unit, exact configuration, interfaces, exclusions, shipping and any separately quoted site work. Franance will follow up by phone or email with a quote order.

Frequently asked questions about bedhead units in Nigeria

### What is the difference between a bedhead unit and a medical-gas outlet?

A bedhead unit is the broader wall-mounted assembly that may contain gas terminals and other services. A medical-gas terminal unit is a gas-specific connection component within the pipeline distribution system. Confirm its exact type and interface separately from the enclosure.

### Are the Amico, BeaconMedaes and Dräger units interchangeable?

No. They are distinct configurable families with different mounting, layout and terminal options. The project team must compare exact drawings, outlet standards, dimensions, services and documentation before choosing.

### Does the BeaconMedaes record have a fixed model number?

No fixed model code was present in the manufacturer sources reviewed for the configured DIN-style GEM Shield example. Request the exact project reference, bill of materials and current drawings in the quotation.

### Does DIN-style GEM Shield terminal mean it fits my hospital's gas system?

No. It describes the terminal configuration example in the catalogue entry. The pipeline designer and manufacturer must verify the outlet connection standard for the specific gas and existing or planned pipeline.

### Does a bedhead-unit quotation include gas installation and verification?

Not unless the written offer explicitly states that scope. Ask which contractor connects the unit, which local requirements apply and what installation, inspection, testing and handover documents are included.

### Can I specify one unit from a product-family picture?

No. Product images illustrate a family or example configuration. Provide room drawings and a complete service schedule, then approve the manufacturer's project-specific submittal.

### Does this guide confirm Nigerian approval, stock or service coverage?

No. Franance must confirm current availability and commercial terms in a quotation. The project team must determine local approvals, design requirements and qualified installation responsibilities.

Common questions

What is the difference between a bedhead unit and a medical-gas outlet?

A bedhead unit is the broader patient-area assembly that may contain gas terminals and other services. A terminal unit is a gas-specific connection component in the pipeline system; confirm its exact type separately from the enclosure.

Are Amico, BeaconMedaes and Dräger bedhead units interchangeable?

No. They are distinct configurable families with different mounting, layout and terminal options. Compare exact drawings, standards, dimensions, services and documentation for the project.

Does the BeaconMedaes record have a fixed model number?

No fixed model code was found in the reviewed sources for the DIN-style GEM Shield example. Request the project-specific reference, bill of materials and drawings.

Does DIN-style GEM Shield prove compatibility with a hospital pipeline?

No. It identifies the listed terminal example only. The pipeline designer, manufacturer and qualified installer must verify the required gas-specific connection for the site.

Does the quotation include gas installation and verification?

Only when the written offer explicitly includes those services. Request separate scope and responsibility for installation, connection, testing, commissioning and handover.

Can I order a bedhead unit from its product picture?

No. Product-family images show examples. Provide room drawings and an approved service schedule, then review the project-specific manufacturer's submittal.

Does this guide confirm Nigerian approval, stock or service?

No. Franance must confirm availability and terms in a current quote, and the project team must establish local requirements and qualified installation responsibilities.

Can I pay online for a Franance bedhead unit?

No. Franance accepts quote orders and follows up by phone or email rather than taking online payment.

Request a project-specific bedhead-unit quotation.

Send room elevations, wall details, bed count, terminal schedule and connection standards, power/data/lighting requirements, rail and accessory needs, quantity and delivery location in Nigeria. Ask Franance for a written configuration, current manufacturer drawings, commercial terms and explicit installation/commissioning exclusions or scope.

Request a bedhead-unit quotation