Buy OT Pendants & Booms in Nigeria.

Buy OT pendants and booms in Nigeria through Franance. The current category contains six distinct ceiling supply unit listings across operating-theatre single-arm and double-arm categories and ICU pendant/boom equipment. Compare exact models and configurations against your room plan, equipment schedule and utility requirements, then request a written quotation. Franance follows up by phone or email; online payment is not available.

Browse this range

Products

6 models

Filter all 6 products

Which OT pendant and boom products can I request in Nigeria?

The current parent-category filter contains six distinct products from Getinge, Dräger and Mindray. The catalogue has three child groups: operating-theatre pendants with single-arm assignments, operating-theatre pendants with double-arm assignments, and ICU pendant/boom equipment. They are ceiling supply units intended to organize equipment and utility access around a clinical workspace; their assigned names do not establish a complete room design, installation package, included accessories or confirmed availability in Nigeria.

Read more

What is the difference between a ceiling supply unit, pendant and boom?

In this catalogue, “pendant” and “boom” refer to ceiling-mounted medical supply equipment, not an entire operating room or a freestanding cart. Manufacturer language varies: some product families are called ceiling supply units, ceiling pendants, medical supply units or booms. These systems can position carriers for devices and accessories and, depending on the exact configuration, provide connection points for medical gases, vacuum, electrical power or data. Each outlet, service and carrier is configuration-specific and must be named in the technical schedule.

Read more

Which single-arm operating-theatre pendants are listed in Nigeria?

The single-arm child contains the Dräger Ambia Single-Arm Ceiling Supply Unit and the Getinge Maquet Moduevo Operating Room Ceiling Supply Unit. The title of the Dräger record specifies one support arm; Dräger describes Ambia as a modular ceiling-mounted supply unit with multiple workstation components and configurations. The assigned Getinge record is a product family listing without an arm count in its title, despite appearing in the single-arm child. Its exact supply configuration remains to be stated in the offer.

Read more

Buy OT pendants and booms in Nigeria

Franance lists six distinct ceiling supply unit products in the OT Pendants & Booms catalogue. The range includes operating-theatre ceiling units listed under single-arm and double-arm categories, plus ICU ceiling pendants. One Getinge operating-room record is assigned to both arm-count categories, so the child-category totals overlap; it is one catalogue product, and its public record does not specify a final arm count. Review the exact listing and request a configuration-specific quotation before making a project decision. Start with the OT Pendants & Booms category in Nigeria, then compare the single-arm operating-theatre pendant listings, double-arm operating-theatre pendant listings, and ICU pendant and boom listings. Send Franance the exact product, room plan, service schedule and delivery destination. Franance follows up by phone or email with a quote order; this catalogue is not an online checkout.

Which OT pendant and boom products can I request in Nigeria?

The current parent-category filter contains six distinct products from Getinge, Dräger and Mindray. The catalogue has three child groups: operating-theatre pendants with single-arm assignments, operating-theatre pendants with double-arm assignments, and ICU pendant/boom equipment. They are ceiling supply units intended to organize equipment and utility access around a clinical workspace; their assigned names do not establish a complete room design, installation package, included accessories or confirmed availability in Nigeria.

There are two records assigned to the single-arm child, three assigned to the double-arm child, and two assigned to the ICU child. Those child counts add to seven because the Getinge Maquet Moduevo Operating Room Ceiling Supply Unit appears in both operating-theatre child filters. Count it once when planning a shortlist. Its catalogue title and family source do not commit to one delivered arm arrangement. The written quote should identify the exact arm count, support-arm lengths, carrier/column or head style, ceiling attachment, media outlets, accessories and product code.

Browse the child pages by application and arm configuration, but confirm that the chosen unit is represented by the manufacturer’s current regional documentation. Parent-category membership is a discovery aid, not a technical selection or compatibility statement. The design team should confirm which equipment belongs on each carrier, which room and utility interfaces are required, and which work is included in the supplier’s offer.

What is the difference between a ceiling supply unit, pendant and boom?

In this catalogue, “pendant” and “boom” refer to ceiling-mounted medical supply equipment, not an entire operating room or a freestanding cart. Manufacturer language varies: some product families are called ceiling supply units, ceiling pendants, medical supply units or booms. These systems can position carriers for devices and accessories and, depending on the exact configuration, provide connection points for medical gases, vacuum, electrical power or data. Each outlet, service and carrier is configuration-specific and must be named in the technical schedule.

An arm is the articulated support between the ceiling attachment and the equipment carrier. A single-arm system has one support arm in the specified arrangement; a double-arm system has two connected support arms that can position a carrier through a different reach and movement envelope. “Double arm” does not automatically mean two separate drops, two carriers, a specific payload, or a particular outlet set. Verify the named arm arrangement and all load limits against the current manufacturer documents for the selected model.

An ICU pendant/boom is selected for a bedside care environment. The included catalogue examples include a single-arm column configuration and a Getinge ICU/recovery ceiling supply unit. These are different records and families; a generic ICU label is not enough to compare them. A horizontal bridge is another ceiling supply approach in the wider market, but no bridge model is assigned in this category. Do not assume that a pictured, adjacent or optional system is part of a listing.

Which single-arm operating-theatre pendants are listed in Nigeria?

The single-arm child contains the Dräger Ambia Single-Arm Ceiling Supply Unit and the Getinge Maquet Moduevo Operating Room Ceiling Supply Unit. The title of the Dräger record specifies one support arm; Dräger describes Ambia as a modular ceiling-mounted supply unit with multiple workstation components and configurations. The assigned Getinge record is a product family listing without an arm count in its title, despite appearing in the single-arm child. Its exact supply configuration remains to be stated in the offer.

Open the Dräger Ambia single-arm category and model result and the Getinge Maquet Moduevo operating-room category and model result. Dräger describes Ambia as a ceiling-mounted unit that can be adapted for different acute-care workstations and notes use in operating theatres and intensive care. The page describes a configurable family; it does not establish that every accessory, outlet arrangement, lift or option is part of this exact catalogue item.

Getinge describes Maquet Moduevo as a ceiling supply unit family for operating rooms with configurable workstation components and accessory options. It also presents distinct solutions for anesthesia, endoscopy and hybrid-room use. These references can inform a project conversation, but they do not define the supplied arm count, payload, ceiling interface or package for the Franance record. Ask for a model-specific drawing and schedule before comparing it with a single-arm unit.

Which double-arm operating-theatre pendants are listed in Nigeria?

The double-arm child contains Dräger Ambia Double-Arm Ceiling Supply Unit, Dräger Movita Double-Arm Ceiling Supply Unit, and the cross-assigned Getinge Maquet Moduevo operating-room record. Dräger’s Ambia technical product specification describes single- and two-support-arm arrangements, and its Movita product information and Movita family page describe two-arm availability, with options that vary by installation. The catalogue’s Movita record specifically describes a two-arm configuration; it does not specify the arm lengths or its complete outlet and accessory schedule.

Review the Dräger Ambia double-arm category and model result, Dräger Movita double-arm category and model result, and the Getinge Maquet Moduevo operating-room result. The Getinge model result is the same record linked in the single-arm section; its cross-assignment is not evidence that two alternative units are included.

Two arms may offer a different reach and positioning pattern than one arm, but the real working envelope depends on the ceiling position, arm lengths, joints, carrier orientation, stops, adjacent equipment and manufacturer-defined limits. Have the supplier provide a dimensioned plan showing the proposed mounting point, arm sweep, collision zones, storage position and working positions for the actual theatre. Have the clinical team review workflow around the operating table, lights, anesthesia workstation, monitors and endoscopy equipment. Do not infer payload or compatibility from arm count alone.

Which ICU pendant and boom products are listed in Nigeria?

The ICU child contains the Getinge Maquet Moduevo ICU Ceiling Supply Unit and Mindray HyPort B30 ICU Pendant, Single-Arm Column Configuration. Getinge’s ICU and recovery information describes ceiling supply units that can organize monitors, infusion equipment, shelves and other room supplies, with product variations including pendant, column and bridge approaches. The Franance listing is an ICU ceiling supply unit record; verify the exact configuration and included functions in its written quotation.

Mindray describes HyPort B30 as a medical supply unit family with different application examples, including an ICU pendant using a single arm and column distribution. The Franance record names that specific configuration. Mindray’s family page also discusses a surgical pendant with two arms and an anesthesia pendant with a single arm; those examples are not part of this ICU product record. See the Getinge Maquet Moduevo ICU category and model result and Mindray HyPort B30 ICU pendant category and model result.

For an ICU or recovery project, map each bed space, nurse workflow, monitor and device position, medical-gas and electrical requirement, access route and cable path. Confirm whether a proposed unit serves one bed or multiple bed positions, whether a bridge or column is specified, and whether accessories are part of the offered configuration. The manufacturer's system examples are not a substitute for a room-by-room schedule, and Franance’s current category does not offer a guarantee of suitability for an individual clinical setup.

How should I plan pendant reach, room geometry and equipment layout?

Begin with a current, dimensioned room drawing and the intended work positions, not with the product image. Record the operating table or bed location and movement, patient access, staff routes, ceiling height and obstructions, doors, fixed lights, monitor positions, anesthesia equipment, imaging or endoscopy equipment, carts and existing ceiling services. Identify the parked position and each expected working position of every arm. A ceiling unit can affect the reachable space and movement of adjacent devices even when it is not in use.

For each carrier, list the equipment by make/model or dimensions and weight, its shelf, rail or mounting interface, required orientation and the intended location. Ask the manufacturer or authorized supplier to state the permitted load for the exact assembly and how load is distributed across the arm, carrier and accessories. Include future equipment only when the project team has specified it. Product-family marketing numbers or a load rating from a different lift, arm or configuration must not be applied to the unit being quoted.

Review the whole three-dimensional envelope. Check arm rotation and extension, carrier height, trolley or equipment access, ceiling cover and structure, movement near a surgical light, monitor arm, patient lift, imaging device, sprinkler, HVAC diffuser and service access panel. For ICU, include bed transfer and maintenance access; for theatres, include positioning for each planned procedure and any mobile equipment. The supplier’s drawing should show dimensions and movement for the quoted arrangement. A site survey and coordinated design review may be needed; neither is automatically included in a product quote.

What ceiling, medical-gas, electrical and data details should I confirm?

The ceiling connection is a structural interface. Before a proposal is finalized, the project’s structural engineer and supplier should review the slab or support structure, attachment details, ceiling build-up, reinforcement or backing, load and moment calculations, access for installation and the exact manufacturer installation drawing. A false ceiling or finish panel is not evidence that the structure can support a pendant. Do not reuse a ceiling flange, anchor, load figure or installation assumption from another product family or room.

Create a utility schedule for each drop. List every medical gas and vacuum service, outlet standard and orientation requested, electrical outlet type and rating, data/network or nurse-call point, control or lighting requirement, and the number and position of each. Confirm source availability and route with the facility engineering team. The precise connection, terminal, outlet, electrical specification and allowed arrangement must be verified against the selected unit and the facility’s applicable standards. Do not assume that a unit has an outlet merely because the manufacturer’s family offers it.

Clarify where building services stop and the ceiling unit begins. Record who designs, supplies, connects, tests and signs off each interface: building structure, medical gas pipeline, vacuum, electrical circuits, data, equipment carrier, ceiling closure and accessories. Confirm how an outage, maintenance access, isolation, inspection, commissioning and user training will be handled. An equipment quote may exclude building work, service extensions, ceiling reinforcement, connections or validation; list inclusions and exclusions explicitly instead of presuming an end-to-end installation.

What should I include in a Nigeria OT pendant quotation request?

Send Franance the exact product title, manufacturer, model or family, catalogue URL, requested configuration, quantity and destination state/city. For each room, include a dimensioned plan, ceiling height and construction information, intended mounting point, room photographs or drawings, working and parked positions, equipment schedule with dimensions and weights, service-outlet matrix, electrical and data requirements, accessories and required documentation. Separate confirmed requirements from questions that the supplier must resolve.

Ask the quotation to state the exact manufacturer product code, arm count and lengths, carrier/column/head configuration, outlet types and count, electrical and data fittings, accessories, load ratings for the specified build, finish, drawings, manuals and any other required documentation. Request the current model-specific datasheet and installation planning information. If a family page shows options, ask the seller to identify which are included, optional, unavailable for the offered region or excluded from the scope.

For Nigeria, provide the delivery city and state, site readiness, receiving contact, access or offloading constraints, target delivery window and whether the project is a new theatre, ICU, recovery area, renovation or replacement. Ask Franance to confirm availability for the destination, starting-price basis or itemized price, currency, quote validity, freight and delivery terms, taxes or other charges, warranty, spare parts, local service coverage and response route. If installation, commissioning, testing, structural work, medical-gas connection, training or acceptance documentation is required, request each as a named line item with the responsible party and stated exclusions. These are questions for the quote; catalogue presence alone does not confirm Nigerian stock, regulatory status, installation capacity or service availability.

Have the facility’s clinical, biomedical-engineering, medical-gas, electrical, structural, infection-prevention and procurement teams review the final proposal as appropriate to the project. Confirm regulatory and market documentation applicable to the intended procurement with the responsible buyer and relevant authorities. Franance can clarify the listed product and quote request, but the customer’s project team must verify site suitability and approve the final coordinated design.

Can I buy OT pendants or booms online from Franance?

No. These are quote-order products. There is no online payment or instant order checkout for the listed ceiling units. Submit the product names, configuration, quantities and site requirements through the Franance contact page for an OT pendant quotation. Franance follows up by phone or email to clarify the project and provide a quotation. Place an order after the written offer identifies the exact configuration, scope, delivery terms and exclusions.

Where can I browse OT pendants and booms in Nigeria?

Use the OT Pendants & Booms category to view all six distinct assigned products, then narrow by single-arm operating-theatre pendants, double-arm operating-theatre pendants, or ICU pendants and booms. The operating-room Getinge Maquet Moduevo record is cross-assigned to the two theatre child categories, so the category result totals overlap.

The wider Anaesthesia & surgical equipment catalogue includes separate equipment families such as anesthesia systems, operating tables and surgical lights. Those categories should be coordinated at room-planning stage, but they are not additional pendant products in this guide. For a project quotation, send Franance the exact model links and an itemized room/utility schedule, then request written confirmation of configuration, availability, service and scope for your Nigerian destination.

Common questions

How many OT pendant and boom products are listed?

The parent category contains six distinct product records. Leaf assignment counts total seven because the Getinge Maquet Moduevo operating-room record is cross-assigned to both single-arm and double-arm categories.

Does the Getinge Maquet Moduevo operating-room listing specify an arm count?

Its current catalogue title does not state an arm count. Ask for the exact arm configuration and product code in the quotation.

Are a single-arm pendant and a double-arm pendant interchangeable?

No compatibility or interchangeability is established by category labels. Compare the exact manufacturer configuration, dimensions, loads, movement envelope, outlets and site interface with qualified project review.

Does the Mindray HyPort B30 ICU listing refer to the surgical pendant?

No. The assigned product is the HyPort B30 ICU pendant with a single arm and column distribution. Mindray presents OR anesthesia and double-arm surgical examples separately.

Does a Franance OT pendant quotation include installation?

The listing does not establish an installation scope. Ask Franance to identify in writing whether surveys, structural work, utility connections, installation, commissioning, testing, training and service are included or excluded.

Can I buy an OT pendant online from Franance?

No. Franance accepts quote orders and follows up by phone or email. A written quotation confirms the product configuration and commercial terms.

Request an OT pendant or boom quotation from Franance.

Send exact product titles, arm and carrier configuration, quantities, Nigerian destination, room drawings, equipment schedule, ceiling and utility requirements, and the installation or commissioning scope you need confirmed. Franance will follow up by phone or email with a quote order.

Request an OT pendant quotation

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart