Buy BIOBASE BKM-K18N Tabletop Class N Autoclave in Nigeria
Request a Franance quotation for a BIOBASE BKM-K18N tabletop Class N autoclave in Nigeria. BIOBASE describes this 18 L model as a gravity-displacement sterilizer and lists a scope that includes glassware, bare metal utensils and unwrapped solid instruments. Confirm that this stated scope matches your facility’s approved loads before requesting a quote. Franance handles quote orders by phone or email; online payment is not offered. Browse the BIOBASE BKM-K18N listing, review the tabletop steam autoclave category, or request a quotation.
What is the BIOBASE BKM-K18N?
BKM-K18N is an 18 L tabletop Class N steam sterilizer in BIOBASE’s BKM-K18/23N series. The manufacturer says the series removes chamber air by gravity displacement and lists selectable 121 °C and 134 °C programmes. BIOBASE specifies suitability for glassware, bare metal utensils and unwrapped solid instruments. It does not describe this model as a Class B sterilizer.
Which loads does BIOBASE say it is suitable for?
BIOBASE’s product page names glassware, bare metal utensils and unwrapped solid instruments. It does not establish suitability for wrapped instruments, hollow devices, porous loads or every item that may fit in the chamber. Ask for current instructions that match the exact offered model and compare them with your facility’s approved load and process requirements. Programme temperatures alone do not confirm load compatibility or process validation.
What are the capacity and chamber dimensions?
BIOBASE lists an 18 L capacity and a 250 × 350 mm chamber for BKM-K18N. The series page lists one rack with three trays. Check the usable chamber space, rack and tray arrangement against the items and batch quantities your facility plans to process. The BKM-K23N is a separate 23 L model with a longer chamber, so make sure the quotation identifies BKM-K18N rather than another series member.
| Selection point | Confirm for the quotation |
|---|---|
| Model | BKM-K18N, 18 L; distinguish from BKM-K23N, 23 L |
| Load type | Confirm unwrapped solid, bare metal or glassware requirement against current instructions |
| Cycle and records | Required 121 °C or 134 °C programme and record-review procedure |
| Site | Supply voltage, 1.6 kW demand, outlet/protection, worktop strength, clearance and ventilation |
| Accessories | Aluminum or optional stainless-steel trays, optional printer and any required record export |
What power and accessories should I confirm?
BIOBASE lists 1.6 kW consumption, AC220 V at 50/60 Hz as standard power and AC110 V at 50/60 Hz as optional. Confirm the exact rating plate and offered version, then have a qualified facility engineer check the electrical supply and site requirements. BIOBASE lists an aluminum tray and USB port as standard, with a stainless-steel tray and printer as optional; ask the quotation to itemize what is included.
How do I request a BKM-K18N quote in Nigeria?
Send Franance your intended load types, batch size, required 121 °C or 134 °C programme, tray and record-keeping needs, facility power details, quantity and destination. Ask the written offer to identify the exact model, included accessories, current manufacturer documents and any installation or training scope. The manufacturer page does not establish Nigerian stock, price, registration, delivery, warranty or local support; request confirmation for the specific offer. Franance will follow up by phone or email with written terms.
Use the current BIOBASE instructions and your facility’s approved process for final selection and operation. This page is purchasing information, not a sterilization procedure.
Common questions
Is BKM-K18N a Class B autoclave?
No. BIOBASE explicitly identifies BKM-K18N as a Class N sterilizer. It uses gravity displacement and BIOBASE states suitability for glassware, bare metal utensils and unwrapped solid instruments.
Can BKM-K18N process wrapped instruments?
The cited BIOBASE page states unwrapped solid instruments and does not establish suitability for wrapped loads. Do not assume a wrapped-load cycle; request current written manufacturer confirmation and follow the facility’s validated process.
What is the difference between Class N and Class B?
The class refers to different sterilizer/load-processing capabilities under applicable standards; it is not a size or quality rating. This listing only establishes BIOBASE’s Class N designation for BKM-K18N. If your approved loads require a different class, specify those loads and standards and request evidence for a suitable model rather than treating BKM-K18N as interchangeable.
What is the chamber size and capacity?
BIOBASE lists 18 L capacity and a 250 × 350 mm chamber for BKM-K18N. Validate that usable chamber space and rack arrangement fit the intended unwrapped load.
Can I pay online for this model?
No online checkout is offered. Franance receives a quote order and follows up by phone or email to clarify the load, accessories, site and written commercial terms.
Request your BIOBASE BKM-K18N quotation from Franance.
Send Franance the BKM-K18N model, intended unwrapped load, required programme, record workflow, site power details, tray/printer needs, quantity and delivery destination. We will follow up by phone or email to clarify the quote order and written offer.
Choose quantity