Generic refrigerated laboratory centrifuge

Confirm the exact product reference and supplied package with your quotation.

Eppendorf

Buy Eppendorf Centrifuge 5920 R Refrigerated Large-Capacity Centrifuge
in Nigeria.

Refrigerated large-capacity laboratory centrifuge

Request a quotation from Franance for an Eppendorf Centrifuge 5920 R in Nigeria. Specify sample workload, vessel formats, required rotor and adapters, electrical requirements and destination so the requested configuration can be reviewed.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • Refrigerated benchtop centrifuge platform
  • Large-capacity rotor options; confirm exact rotor and adapters
  • Rotor-dependent accommodation for different vessel formats
Eppendorf Centrifuge 5920 R Refrigerated Large-Capacity Centrifuge specifications
ManufacturerEppendorf
ModelCentrifuge 5920 R
Equipment classRefrigerated large-capacity benchtop centrifuge
Maximum listed capacityUp to 4 × 1,000 mL; rotor-dependent
Rotor configurationConfirm selected rotor, buckets and adapters

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

Where can I buy an Eppendorf Centrifuge 5920 R in Nigeria?

Start with the exact 5920 R filtered listing and submit a Centrifuge 5920 R quotation enquiry. Include your organisation, destination city and state, quantity, sample throughput, vessel models, rotor requirement, refrigeration need and project timeline. For an existing laboratory, identify the current centrifuge, electrical version and accessories. For a new site, include a layout, bench specification, access route and power information.

Read more

What is the Eppendorf Centrifuge 5920 R?

The 5920 R is a refrigerated large-capacity benchtop centrifuge. Eppendorf describes the platform for higher-volume workflows and offers fixed-angle, swing-bucket and plate rotor options. Depending on the selected rotor and buckets, the manufacturer lists capacities including up to 4 × 1,000 mL. Other arrangements may suit different tubes, bottles, plates or deepwell plates. This product is not a general-purpose claim that every vessel can be used in every rotor.

Read more

Which 5920 R rotor and vessel formats should I request?

Prepare a vessel schedule before requesting a price. List each tube, bottle, plate or deepwell plate by manufacturer, catalogue reference, material, geometry, nominal size, cap, number per batch and required adapter. If a process uses multiple vessel families, write each one on a separate line and request the exact rotor, bucket and adapter configuration for each. A universal bucket may support certain vessel formats with compatible adapters, but that does not make all vessels interchangeable or guarantee the needed capacity.

Read more

Buy the Eppendorf Centrifuge 5920 R in Nigeria

Buy an Eppendorf Centrifuge 5920 R in Nigeria through a configuration-specific quotation from Franance. Share the samples and vessel formats, batch volume, required rotor and adapters, temperature-control needs, electrical supply, room layout and delivery destination. Eppendorf identifies the 5920 R as a refrigerated, large-capacity benchtop centrifuge with rotor options that can reach four 1,000 mL vessels. That capacity depends on the selected rotor and compatible buckets or adapters. The catalogue record does not identify a specific rotor package, electrical version or accessory set, so ask for each item and the exact regional product code in the written offer. View the exact Eppendorf Centrifuge 5920 R listing in laboratory centrifuges, the laboratory centrifuge category, and the separate research-grade centrifuge category. Franance takes quotation enquiries rather than online payment. A listing does not promise Nigerian stock, a fixed price, lead time, warranty, installation, local service or that the rotor or vessels shown in manufacturer materials are included. Confirm the offered scope and terms in writing.

Where can I buy an Eppendorf Centrifuge 5920 R in Nigeria?

Start with the exact 5920 R filtered listing and submit a Centrifuge 5920 R quotation enquiry. Include your organisation, destination city and state, quantity, sample throughput, vessel models, rotor requirement, refrigeration need and project timeline. For an existing laboratory, identify the current centrifuge, electrical version and accessories. For a new site, include a layout, bench specification, access route and power information.

Franance will follow up by phone or email to clarify the requested package. Ask for the instrument’s exact catalogue number, 230 V or other regional electrical configuration, rotor, buckets, lids, adapters, included consumables, delivery, installation, commissioning, training, warranty and service as separate written line items. Eppendorf’s regional catalogue lists packages with different rotors and adapters; similar family names do not prove that the package you need is included. The final quote must confirm availability and commercial terms for your destination.

What is the Eppendorf Centrifuge 5920 R?

The 5920 R is a refrigerated large-capacity benchtop centrifuge. Eppendorf describes the platform for higher-volume workflows and offers fixed-angle, swing-bucket and plate rotor options. Depending on the selected rotor and buckets, the manufacturer lists capacities including up to 4 × 1,000 mL. Other arrangements may suit different tubes, bottles, plates or deepwell plates. This product is not a general-purpose claim that every vessel can be used in every rotor.

The “R” denotes a refrigerated model. Keep that suffix in the request, quotation and receiving records. The Eppendorf 5920 R is distinct from non-refrigerated centrifuges and from other refrigerated models that may have different rotor capacities, operating limits, power requirements or room footprints. Do not select it solely because the headline capacity sounds suitable. Match the instrument, rotor, vessel and method under current manufacturer documentation.

Eppendorf publishes maximum speed up to 13,700 rpm and maximum RCF up to 21,194 × g for specified configurations; swing-bucket and plate rotors have different published limits. Capacity, speed, RCF and temperature performance do not apply identically across all rotors and loads. The laboratory’s approved method and the current rotor table control whether a proposed configuration is acceptable.

Which 5920 R rotor and vessel formats should I request?

Prepare a vessel schedule before requesting a price. List each tube, bottle, plate or deepwell plate by manufacturer, catalogue reference, material, geometry, nominal size, cap, number per batch and required adapter. If a process uses multiple vessel families, write each one on a separate line and request the exact rotor, bucket and adapter configuration for each. A universal bucket may support certain vessel formats with compatible adapters, but that does not make all vessels interchangeable or guarantee the needed capacity.

Eppendorf’s 5920 R materials describe swing-bucket options for large vessels and universal bucket arrangements for certain tubes and plates. Fixed-angle rotors are another configuration with different vessel counts and performance limits. Ask the supplier to identify whether the proposed package uses S-4×1000, S-4×Universal-Large, FA-6×250 or another exact rotor. Verify the bucket, lid, rotor cover, adapter and balance accessories by part number. Manufacturer product pages can display several packages that have different parts included.

For a high-volume request, state whether you want to process large bottles, many conical tubes, blood collection tubes, microplates or deepwell plates. The maximum vessel count, actual sample volume, adapter compatibility and RCF depend on the chosen rotor and vessel. Ask for the manufacturer’s current compatibility table rather than assuming that “up to 4 litres” means your desired bottle or sample load is approved.

What does refrigeration mean for sample workflow?

The 5920 R has active refrigeration and Eppendorf describes temperature management features for the system. Whether the 5920 R meets a particular temperature-controlled procedure depends on the exact rotor, load, setpoint, ambient conditions, run duration and current manufacturer limits. Do not treat the model’s settable temperature or a product-family claim as evidence that every sample will remain at the required temperature under all operating conditions.

In your quote request, state the relevant temperature requirements from your approved method, whether pre-cooling is part of the workflow, the number and type of vessels, expected starting conditions and run schedule. Ask the supplier to confirm the operating and ambient-condition limits for the exact offered configuration. The user manual includes model-specific ambient, temperature, power and installation guidance; your facility must be assessed against the current manual and site conditions.

If sample temperature is critical, have the method owner determine acceptance monitoring and any additional temperature checks. A centrifuge’s refrigeration function does not validate the process or replace the lab’s temperature records. Do not infer sample suitability, stability or clinical outcome from a feature description.

How should I compare rotor force, speed and capacity?

Compare each quoted assembly at the same level of detail: model and electrical version, rotor, buckets, adapters, vessel, maximum permitted RCF, maximum rpm, capacity and any limits relevant to sample density or temperature. The 5920 R’s top-line specification is not a universal limit that applies to every rotor. Eppendorf lists significantly different maximum RCF values for fixed-angle, swing-bucket and plate rotor classes, illustrating why rotor selection matters.

If the laboratory procedure specifies RCF, preserve that value and the reference rotor in the purchasing brief. The relationship between rpm and RCF depends on rotor geometry, so values from one rotor cannot be transferred by quoting rpm alone. Have the method owner check the proposed rotor’s documented limit, sample vessel rating and adapter compatibility. This guide does not provide operating settings or recommend substitutions to an approved method.

Ask for the exact rotor documentation and loading requirements before accepting a package. Confirm how many positions are available, which bucket arrangement is included, and whether all required adapters and lids are priced. For parallel workflows, compare capacity per run, allowable sample volume and number of runs only after the instrument’s configuration is confirmed.

Does the catalogue listing include the rotor, buckets or adapters?

The product record names the Centrifuge 5920 R but does not assign a rotor or accessory package. Eppendorf’s product page describes separate catalogue configurations, some of which include a rotor, buckets and adapters, while other configurations may differ. A photograph or headline product specification is not an inclusion list. The quote should state whether it is instrument-only or a complete named package.

Ask for manufacturer part numbers for the instrument, rotor, buckets, adapters, rotor lids or caps, any aerosol-tight components, power cord and requested starter accessories. If the lab has existing 5920 R rotors, provide their exact part numbers and condition; do not assume a rotor from a different Eppendorf centrifuge fits. Request manufacturer confirmation for compatibility with the offered model.

If containment is required by the risk assessment, specify the exact aerosol-tight rotor, buckets, caps or lids needed and ask for supporting documentation. Eppendorf’s descriptions of optional aerosol-tight caps for some rotor packages do not mean all packages include them. The laboratory’s biosafety lead must decide containment requirements for its material and process.

What electrical, room and facility checks matter in Nigeria?

The 5920 R is a large and heavy refrigerated benchtop unit. Eppendorf’s technical manual for the 230 V version lists dimensions of approximately 73.7 × 70.7 × 40.3 cm, weight of 139 kg without rotor, current consumption of 12 A and maximum power consumption of 1,650 W. Regional versions differ, so confirm the supplied nameplate and exact electrical configuration. A 120 V package is not a drop-in assumption for a Nigerian facility.

Before ordering, ask for the current installation manual and identify required clearance, bench loading, floor or support requirements, ventilation and access for servicing. Check the full movement route, including door widths, corridors, lift capacity and turning space. Leave room for lid operation and for handling heavy rotors and buckets safely. The 5920 R’s dimensions and weight differ from compact benchtop centrifuges and should be reviewed by facilities staff before delivery.

Share measured voltage and frequency, grounding, phase, outlet type, circuit capacity and local generator or backup-power arrangements with the supplier. Ask whether the exact offered version requires a dedicated circuit or other approved power protection. Have a qualified electrician review the installation against the manufacturer nameplate and applicable local requirements. Do not assume a stabilizer or UPS can support the refrigeration compressor without checking compatibility and capacity.

The manual states ambient and humidity ranges for indoor operation; confirm the current limits for the precise order and assess the laboratory’s air conditioning, heat load and moisture conditions. A warm room or unstable power may affect facility readiness, but this guide does not infer performance at a particular site. Obtain written site requirements and coordinate with the supplier before scheduling installation.

What recurring supplies and maintenance should I plan for?

Build a parts and consumables list around the selected rotor package and laboratory procedures. Items can include compatible bottles or tubes, plates, adapters, seals, lids, rotor parts and cleaning materials specified in the manufacturer instructions. Ask for current references, replacement criteria, available service documentation and local replenishment arrangements. Do not use a vessel because its nominal volume matches a rotor description; compatibility depends on exact geometry and approved documentation.

Include maintenance expectations for the centrifuge, refrigeration system, rotor, buckets and accessories. Request the schedule and any checks or replacement requirements from the current user manual. Ask whether preventive maintenance is available at the Nigerian delivery site, who performs it, what travel or parts are included, response expectations and how repairs are escalated. A product listing does not confirm a local service engineer or spare parts inventory.

Clarify warranty eligibility and duration for the specific product code and destination. Registration promotions, regional statements or manufacturer website terms may not apply to every country or sale route. Ask for the written warranty provider, coverage, exclusions, claim process and service location in the quote. If uptime is critical, request separate options for service, spare rotor parts and backup workflow planning.

How do installation, commissioning and training fit the order?

Specify whether you need delivery only or a complete installation and handover. Ask the quote to include delivery to the facility, positioning, power-up, configuration, checks, demonstration, documentation and any manufacturer-authorised commissioning that is available for the offered configuration. Identify who is responsible for bench preparation, electrician work, access route, temperature and environmental readiness, and disposal of packaging. Do not schedule delivery until the supplier confirms installation prerequisites and the facility confirms readiness.

Agree acceptance criteria in advance. The laboratory may request confirmation of model and electrical version, rotor identification, included accessories, instrument condition, operation of controls and completion of agreed installation checks. Ask whether formal qualification or calibration documents are available, who issues them and what work they cover. Basic operation or a service visit is not the same as method validation.

Training should be tied to the 5920 R version and selected rotors. Request instruction for qualified users on routine controls, rotor identification, loading requirements in the manual, temperature functions, cleaning, inspection, fault response and escalation. Confirm number of users, session duration, language, format, training materials and competency records. The laboratory remains responsible for approving its operating procedures and ensuring that users are trained for their roles.

How do I evaluate method, quality and regulatory fit?

Start with the exact procedure and its requirements: sample type, volume, vessel, rotor, RCF, temperature, run conditions, containment and recordkeeping. Ask the manufacturer or supplier to map those requirements to a documented 5920 R rotor assembly. Have the laboratory’s technical owner verify that all tubes, bottles, plates and adapters meet the current manufacturer limits and the method’s own restrictions.

The category label “laboratory centrifuge” is a catalogue taxonomy term, not a statement that the product is approved for a particular diagnostic, clinical or regulatory purpose. If it will be used for regulated testing, accreditation or production, ask the responsible authority or quality manager to verify requirements for the intended use and jurisdiction. Request current declarations, manuals, installation records and any relevant service documents for the exact regional model; a manufacturer product family page does not establish a particular site’s compliance.

Define which tasks the supplier will perform and which remain with the lab. Installation and operational checks can establish that equipment was set up as agreed. They do not validate an assay, qualify an entire laboratory or prove a clinical result. Keep method validation, staff qualification, risk assessment, quality controls and biosafety decisions under the laboratory’s approved systems.

What should I include in a 5920 R quotation request?

Send Franance the exact model, intended use, number of units, vessel schedule, required batch capacity, rotor and bucket preference, adapters, lids or aerosol-tight needs, temperature requirements, electrical version and site information. Include the facility city and state, bench and access details, measured power, ambient conditions, requested documentation, installation, training, service and delivery schedule. If the order is for a regulated workflow, provide the relevant equipment and method criteria for compatibility review without treating the supplier response as regulatory approval.

Ask for an itemised quotation showing the model and regional product code; exact rotor, buckets, adapters and lids; included consumables; installation, commissioning and training; freight, duties or taxes; warranty and service; and any exclusions. Ask the supplier to confirm local availability, expected timeline and support in writing. Compare only equivalent rotor packages and electrical versions.

Use the Centrifuge 5920 R filtered listing or send a quotation enquiry to Franance. Franance follows up by phone or email; an enquiry is not an online sale or stock reservation.

Frequently asked questions about buying the 5920 R in Nigeria

### What is the maximum capacity of the 5920 R?

Eppendorf lists capacity up to 4 × 1,000 mL in selected rotor configurations. Other vessel formats have different rotor and adapter combinations. Confirm your exact vessel references and package.

### Is the Centrifuge 5920 R refrigerated?

Yes. Eppendorf identifies it as a refrigerated centrifuge. Confirm current temperature and ambient limits for the exact order and discuss the procedure’s requirements with the laboratory owner.

### Does it include an S-4×1000 rotor?

The catalogue record does not specify a rotor package. Request the exact rotor and accessory catalogue numbers in the quotation.

### Can it process plates and bottles with one rotor?

Eppendorf describes universal bucket options for some tubes and plates. Vessel fit depends on the rotor, bucket and adapter combination. Verify each format against manufacturer documentation.

### What electrical supply should a Nigerian facility prepare?

Use the exact unit nameplate and current manual. The cited 230 V manual lists 12 A and 1,650 W maximum, but other regional versions differ. Have a qualified electrician confirm facility readiness.

### Does the category mean it is approved for diagnostics?

No. The category is a catalogue grouping, not a regulatory or intended-use determination. Confirm requirements with the laboratory’s quality lead and relevant authority.

### Can Franance guarantee stock, installation or service?

Those details are not confirmed by the catalogue. Provide the destination and requested scope, then obtain written terms for the specific order.

Sources and limitations

Model and rotor details were checked against Eppendorf’s Centrifuge 5920 R product page, the Eppendorf Centrifuge 5920 R operating manual, and the regional Centrifuge 5920 R product information. Sources reviewed 20 October 2026.

Rotor-specific capacities and limits apply only to the documented assembly. The available catalogue record does not state a selected rotor, electrical version, package, included accessory set or service route. Verify the current product code, compatibility, site requirements, local price, availability, delivery, installation, warranty and support in writing. This is procurement guidance; it does not prescribe centrifugation parameters, validate a method, promise a clinical outcome or establish compliance at a Nigerian facility.

Request your Eppendorf Centrifuge 5920 R Refrigerated Large-Capacity Centrifuge quotation from Franance.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Generic refrigerated laboratory centrifuge

Find equipment.

View cart