Buy Dialysis Water Distribution Components in Nigeria.

Buy dialysis water distribution components in Nigeria through Franance by specifying station connections, pipework, drain arrangement, system interfaces and site scope. The category currently lists Adaptaid WTR-042, a point-of-use dialysis wall box rather than a complete RO plant or distribution loop. Request a quote for the exact variant and Nigerian destination.

Products

2 models

Filter all 2 products

What is a dialysis water distribution wall box?

A dialysis wall box is a point-of-use station at a hemodialysis bay where connections for treated water and waste drainage are made available near the dialysis machine. CDC describes wall boxes as recessed frames at hemodialysis stations that contain connections through which the machine receives treated water (and, depending on the installation, acid and base concentrates) and disposes of waste. The exact content of an individual box depends on the product and facility design. Adaptaid WTR-042 is specifically listed as a dialysis wall-box station with purified-water supply and separate drainage connections.

Read more

Which WTR-042 configuration is listed in Nigeria?

Franance’s product record is Adaptaid WTR-042, but it does not settle which connection variant the facility needs. Adaptaid’s manufacturer page describes a recessed stainless-steel station with single or double purified-water supply and single or double air-gap drain arrangements, with additional options. Listed configurations vary by inlet pipe size and by whether there is one or two connections. The WTR-042 family page identifies options including P001 through P006, and P011/P012 raw-water configurations; the precise part selection must be checked against the manufacturer's current schedule.

Read more

How should I choose single or dual water and drain connections?

Count the machines to be served at the wall box, then trace the actual water supply and waste arrangement on the engineering drawing. Adaptaid describes a single or dual purified-water supply and single or dual drainage options; its page says the dual arrangement allows two simultaneous hemodialysis treatments. That statement describes the station arrangement, not a guarantee that the upstream water plant, distribution loop, drainage or dialysis equipment can support two simultaneous treatments. A qualified designer must check capacity and the whole system.

Read more

Buy Dialysis Water Distribution Loop Components in Nigeria

Buy dialysis water distribution components in Nigeria through Franance by specifying the actual point-of-use stations, water and drain connections, treatment-unit interface, pipework, station count and project scope. The current category lists one item: the Adaptaid WTR-042 Dialysis Wall Box Station. It is a wall-mounted connection and drain station for a dialysis bay, not a complete reverse-osmosis plant or the entire distribution loop. Select its configuration from the facility drawing and request a quotation that states exact fittings and Nigerian delivery destination. Franance follows up by phone or email; there is no online checkout. Review the Adaptaid WTR-042 filtered product listing and the full dialysis water distribution components category. Provide the wall-box location, number of treatment stations, pure-water inlet and drain arrangement, pipe size and material, drainage design, connection standards, and whether the project is new installation or replacement. Have the dialysis-water engineer and clinical water-quality programme define and approve the complete system.

What is a dialysis water distribution wall box?

A dialysis wall box is a point-of-use station at a hemodialysis bay where connections for treated water and waste drainage are made available near the dialysis machine. CDC describes wall boxes as recessed frames at hemodialysis stations that contain connections through which the machine receives treated water (and, depending on the installation, acid and base concentrates) and disposes of waste. The exact content of an individual box depends on the product and facility design. Adaptaid WTR-042 is specifically listed as a dialysis wall-box station with purified-water supply and separate drainage connections.

The WTR-042 is not a reverse-osmosis system, pump, storage tank, dialysis machine or complete recirculating loop. It does not alone define the quality of water delivered at the point of use. The system upstream and the distribution pipes, sampling points, disinfection strategy, monitoring and documented water-quality management remain part of the engineered installation. The manufacturer describes compatibility with heat-disinfected reverse-osmosis systems; that statement does not approve every RO design, connector or material combination.

For a project, use “wall-box station” for the point-of-use item and distinguish it from the full distribution system. If your purchasing brief uses “dialysis loop components,” name the actual station, pipe, fitting, return line, sample port or other component required. This prevents a single wall box product from being mistaken for a complete water treatment package.

Which WTR-042 configuration is listed in Nigeria?

Franance’s product record is Adaptaid WTR-042, but it does not settle which connection variant the facility needs. Adaptaid’s manufacturer page describes a recessed stainless-steel station with single or double purified-water supply and single or double air-gap drain arrangements, with additional options. Listed configurations vary by inlet pipe size and by whether there is one or two connections. The WTR-042 family page identifies options including P001 through P006, and P011/P012 raw-water configurations; the precise part selection must be checked against the manufacturer's current schedule.

Adaptaid describes 16-gauge 316 stainless-steel housing and 316 stainless-steel quick-connect fittings. Its page lists front purified-water fittings and drain fittings, with the specific count and form depending on the configuration. The product page describes external dimensions of 14.875 by 15.75 inches and internal dimensions of 12.5 by 13.5 inches, and a wall-mounting frame width of 1.375 inches. These are product references, not a substitute for an approved mounting drawing or site survey.

The current Franance listing does not specify an exact P-code, pipe size, connection quantity, door, additive ports, or whether any installation materials are included. The manufacturer says custom configurations are available and an installation kit includes mounting hardware for standard wall boxes. Confirm what applies to the offered configuration. Use the WTR-042 brand-filtered listing to request the exact product reference and option schedule.

How should I choose single or dual water and drain connections?

Count the machines to be served at the wall box, then trace the actual water supply and waste arrangement on the engineering drawing. Adaptaid describes a single or dual purified-water supply and single or dual drainage options; its page says the dual arrangement allows two simultaneous hemodialysis treatments. That statement describes the station arrangement, not a guarantee that the upstream water plant, distribution loop, drainage or dialysis equipment can support two simultaneous treatments. A qualified designer must check capacity and the whole system.

The number of treatment stations, expected operating concurrency, connection type and service access should be captured in the schedule. For a single bay replacement, identify the existing supply and drain interfaces and confirm whether the wall opening matches the replacement. For a new unit, specify the chosen tubing or pipe size, rear supply fitting, front quick connect, drain count, spacing, orientation and any optional door or additive ports. Do not select the dual inlet just because it looks future-proof; a configuration should correspond to a defined system design and facility plan.

Clarify whether the wall box is intended to serve one machine at a time or two treatment points, and how each outlet is isolated and labelled under the installed design. Confirm connection references at both ends: the wall box fitting, facility pipework, machine hose and drain. Never assume connectors fit based on appearance. The design and installation team should check manufacturer compatibility, pressure and flow requirements, pipe material, drainage and access before purchase.

What is the difference between a wall box and a dialysis water loop?

The water treatment equipment removes contaminants from the incoming supply; the distribution system carries the treated water to points of use; and the wall box provides a station-level interface and drainage arrangement. These are linked but distinct parts of the project. ISO 23500-2:2024 addresses water treatment equipment and components from the point water is delivered to purification through the point of use, including piping and fittings. ISO 23500-3:2024 addresses water quality and ongoing monitoring. The facility should obtain the current standards and have the design team determine the applicable requirements rather than relying on a catalogue description.

The WTR-042 page says the station is designed for use with heat-disinfected RO systems and periodic heat disinfection. This does not mean that every upstream RO system, loop, drain, accessory or chemical disinfectant is automatically compatible. Verify the disinfection method, temperature, contact conditions, materials and procedure against the instructions for all connected components. Maintain the station within a documented water quality and infection-control plan.

For linked equipment, browse Franance’s separate dialysis RO water treatment systems and the broader dialysis water systems category. The listings are quote enquiries. They do not imply a designed, validated or commissioned system package. Procurement should keep a clear schedule of component boundaries, engineering responsibility, commissioning and acceptance criteria.

What should a dialysis water point-of-use layout include?

Start with a station-by-station drawing. Show the machine position, purified-water supply, drain, wall box location, adjacent chairs and access for clinical staff, cleaning and maintenance. Indicate all pipe and fitting sizes, material specifications, connection type, orientation, branch or return arrangement and the equipment served. Mark pipe routes and any access panels so that inspection, sampling, disinfection and repair can be planned. The exact design must come from the qualified project engineer and dialysis water-quality lead.

The facility should consider how stagnant branches, unused taps, joints and difficult-to-clean surfaces will be avoided and controlled. CDC infection-control guidance highlights regular disinfection and design considerations such as avoiding dead ends and unused branches where practical, and managing distribution systems to limit contamination risks. These references are not a substitute for Nigerian law, applicable current standards or a site-specific water programme. The designer should state the validation, water sampling and monitoring responsibilities for the installed system.

Confirm that the wall box can be cleaned and inspected in its actual location. Adaptaid describes sloped surfaces and an enclosed, removable wastewater compartment intended to reduce splash and support drainage and cleaning. Ask for the current installation and maintenance instructions, access clearances, how the compartment is removed, and which cleaning or disinfection methods are approved. Confirm that the wall construction, recess, frame and mounting kit suit the facility—not simply a standard wall box assumption.

How should I plan a WTR-042 replacement or new installation?

For replacement, record the present wall-box manufacturer and model, actual P-code if available, pipe size, water and drain connections, opening dimensions, wall construction, service access and what lies behind the finished wall. Photograph the existing station and measure the location, but have the installer compare those measurements with Adaptaid’s current drawing. Determine whether existing lines can be reused or whether they need alteration; the product listing alone does not decide that.

For a new installation, define the number of dialysis bays and simultaneous use, treatment-water design, RO system interface, required line and drain arrangement, wall construction and maintenance access. The manufacturer lists the wall box as compatible with heat-disinfected RO systems and provides single or dual connection configurations. The water-treatment engineer must verify that the chosen RO plant and distribution loop can support the number and demand of points while maintaining the specified quality and monitoring plan. A single WTR-042 listing is not proof of that capacity.

State who is responsible for design, supply, installation, system flushing or disinfection, acceptance testing, documentation and staff handover. Confirm where the wall-box scope ends and the RO supplier, pipework contractor, building contractor and dialysis-machine supplier scopes begin. If the quote needs site engineering or installation, request those services as separate explicit line items. Franance’s listing does not promise that installation or commissioning is included.

What information is needed for a Nigerian quotation?

Send the exact Adaptaid product name and WTR-042 model, desired P-code or required interface, quantities and facility delivery location. Attach the wall detail or connection schedule and state whether this is a new project, replacement or extension. Include the single- or dual-supply need, drain count, pipe size/material, front connection requirements, rear interface, optional door or additive ports, wall opening, installation kit requirements and any requested engineering scope. If your team is still selecting a configuration, share its design criteria and ask for a supplier clarification rather than guessing a variant.

Ask the written quote to show the exact part reference and every included fitting, gasket, bracket and mounting component; product dimensions and drawing revision; material specification; installation and maintenance instructions; compatibility assumptions; lead time and current availability; freight and packaging; taxes; warranty; and exclusions. Confirm if any items are supplied separately. Ask whether the offered component requires installation by a specified qualified person and whether project work is separately priced.

For water-treatment systems, the procurement schedule should also identify who delivers design calculations, water-quality baseline and sampling plan, disinfection procedures, commissioning and acceptance records, operating documentation and ongoing maintenance. These are project deliverables to assign to the responsible parties; do not assume the wall box supplier or Franance has included them unless the quote states so. Include Nigerian destination city and state to receive an accurate delivery and commercial response.

How do I buy dialysis water distribution components in Nigeria?

Browse the Dialysis Water Distribution Loop Components category and the Adaptaid WTR-042 product listing. Send a quote request with your configuration, drawings, quantities and Nigerian delivery location. Franance will follow up by phone or email to clarify the order and confirm current price, availability and commercial terms in writing. The enquiry does not place an online order or certify a system design.

If you require a complete dialysis-water project, identify the wall-box station as one component within a wider engineered request. Link the quote to the RO water-treatment plant, return loop, distribution piping, sampling points, monitoring and commissioning scope as separate items. The facility’s dialysis water lead should review technical documents before the procurement order is accepted. Never describe WTR-042 by itself as a full dialysis loop or as a complete purification system.

Frequently asked questions about dialysis water distribution components

Is the WTR-042 a complete dialysis RO plant? No. It is a point-of-use wall station for connections and drainage; treatment and the complete distribution system are separate.

Does one WTR-042 serve two dialysis stations? The manufacturer describes a dual-connection variant that can allow two simultaneous treatments. Confirm the exact P-code and have the designer verify the capacity and full system.

Does the current Franance listing identify the exact P-code? No. Request the specific water and drain connection configuration in the quotation.

Is the WTR-042 compatible with every RO plant? The manufacturer describes it for heat-disinfected RO systems. Compatibility with the actual plant, pipework, fittings and disinfection cycle must be checked against current technical instructions.

What material is specified? Adaptaid states 16-gauge 316 stainless-steel housing and 316 stainless-steel quick-connect fittings. Confirm the offered version and documentation.

Does the quote include installation? The listing does not establish that. Ask the written quotation to itemise installation, engineering, commissioning and acceptance work separately.

Manufacturer and reference sources

Product configuration, materials and dimensions are based on Adaptaid’s WTR-042 dialysis wall-box product page, reviewed 20 October 2026. System boundaries and standards references are grounded in ISO 23500-2:2024, ISO 23500-3:2024, and CDC guidance on dialysis wall boxes and drains and water use in dialysis. Requirements are project-specific; the current applicable standards, regulations and design must be determined by qualified project professionals.

Common questions

Is the WTR-042 a complete dialysis RO plant?

No. It is a point-of-use wall station. The water treatment plant, distribution loop and other system components are separate.

Does one WTR-042 serve two stations?

The manufacturer describes a dual-connection arrangement for two simultaneous treatments. The system designer must confirm the selected configuration and upstream system capacity.

Does Franance’s listing identify a specific P-code?

No. Request the exact supply and drain variant in the quote.

Is WTR-042 compatible with every RO system?

Adaptaid describes it for heat-disinfected RO systems. Confirm compatibility with the actual water plant, components and disinfection procedures using current technical documents.

Does the product include installation?

The category record does not establish that installation is included. Have the quote list installation, engineering and commissioning scope separately.

Request a dialysis water distribution quotation from Franance.

Send the exact station connections, P-code or required specification, site drawing, quantities, Nigerian destination and requested installation scope. Franance will follow up by phone or email with a quote order.

Request a WTR-042 quotation

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart