Maquet Betaclassic Hydraulic Operating Table 1118.01B0
Mobile hydraulic operating-room table
Medical equipment and biomedical engineering.
Abuja, Nigeria.
Compare three hydraulic operating-table records listed by Franance: Getinge Maquet Betaclassic 1118.01B0, Keling 3001 Series and Shanghai Zhenghua MT600. Share your theatre specification, required movements and accessories, room/access details, quantity and destination for a quotation on the exact configuration.
6 models

Mobile hydraulic operating-room table


Manual hydraulic operating table

Hydraulic Operation Table - Side End Control

Hydraulic Operation Table - Head End Control

The category currently contains three assigned records. Getinge's Maquet Betaclassic is recorded as reference 1118.01B0. Its official brochure describes a mobile table with manually operated hydraulic and pneumatic adjustment features, SFC padding and, for that reference, no head rest or leg plates. Getinge also lists reference 1118.01K0 with longitudinal shift; that is a different configuration and is not the reference currently shown in the Franance catalogue. Confirm the exact reference and accessories in the quote.
Read moreThe three current products differ in mechanism details, selection granularity and published configuration. Getinge describes the Betaclassic as a mobile operating table with a pedal-operated hydraulic power unit and selector. Its official page says it does not depend on an external power source. Its brochure sets out particular references and optional accessories, so the family name or product image should not be used to infer that every section is included.
Read moreBegin with the operating-room specification, then compare the named model's technical documents line by line. Getinge's Betaclassic brochure lists an overall height range of 600–950 mm without padding, a tabletop inclination of +25°/−25°, lateral tilt of 15°, back-plate movement of +60°/−50° and leg-plate movement of 0°/90°. It lists a 155 kg maximum overall load and an optional longitudinal shift of 290 mm. These figures apply to the brochure's equipment description; validate the exact version and conditions for the offered table.
Read moreBuy a hydraulic operating table in Nigeria through Franance by comparing the exact table reference, movements, sections and accessories against your theatre specification, then requesting an itemised quotation. The current Franance category lists three direct product assignments: Getinge Maquet Betaclassic 1118.01B0, Keling Medical 3001 Series and Shanghai Zhenghua MT600. These are distinct products and their published specifications are not interchangeable. Franance accepts quote orders rather than online payments. Send the required model or variant, quantity, positioning and accessory schedule, theatre details and destination in Nigeria. The team follows up by phone or email to clarify the request. A catalogue listing is not confirmation of stock, price, delivery, warranty or service; the final written quotation must state what is being offered.
The category currently contains three assigned records. Getinge's Maquet Betaclassic is recorded as reference 1118.01B0. Its official brochure describes a mobile table with manually operated hydraulic and pneumatic adjustment features, SFC padding and, for that reference, no head rest or leg plates. Getinge also lists reference 1118.01K0 with longitudinal shift; that is a different configuration and is not the reference currently shown in the Franance catalogue. Confirm the exact reference and accessories in the quote.
Keling Medical's 3001 Series is a family rather than a selected suffix. The manufacturer lists 3001, 3001A and 3001B as mechanical hydraulic tables. Franance's current model field says “3001 Series,” so it does not select one variant for you. Ask the quotation to identify the exact suffix, construction, tabletop and included sections.
Shanghai Zhenghua's MT600 is listed as a manual hydraulic operating table. The manufacturer publishes measurements and movements for this model. Use these as a starting point for specification review, not as a guarantee that any proposed configuration meets your hospital's requirements.
Browse the hydraulic operating-table listing and use its exact model-filtered pages to identify each record. If you are evaluating another manufacturer or reference that is not listed, send Franance the exact product documentation and procurement requirement for review instead of assuming it is already catalogued or locally available.
The three current products differ in mechanism details, selection granularity and published configuration. Getinge describes the Betaclassic as a mobile operating table with a pedal-operated hydraulic power unit and selector. Its official page says it does not depend on an external power source. Its brochure sets out particular references and optional accessories, so the family name or product image should not be used to infer that every section is included.
Keling describes the 3001 family as mechanical hydraulic, with three model variants and dual-side controls for major functions. The product page distinguishes the 3001, 3001A and 3001B by construction and features; the 3001B listing includes a double top and detachable leg section. These differences are manufacturer descriptions, not a reason to choose one variant without reviewing the hospital's procedural requirements and the current documentation.
Zhenghua identifies the MT600 as manual hydraulic and describes gas-spring control for the individual leg and back plates. Its published specifications include a 500 mm width, minimum length of 2,000 mm, lowest height of no more than 670 mm and a 300 mm elevation range. Review exact measurement definitions, tolerances and table revision before relying on them in a tender response.
These products should not be ranked by the general word “hydraulic.” Compare each exact offer against the same approved criteria: operating mechanism, dimensions, adjustment range, tabletop design, accessories, load conditions, imaging needs, room access, maintenance documents and commercial scope. Where a mandatory requirement is not clearly supported by the public source, keep it as an open question and request current manufacturer evidence. A different model can be considered only if the institution's authorised reviewers approve the variation.
Begin with the operating-room specification, then compare the named model's technical documents line by line. Getinge's Betaclassic brochure lists an overall height range of 600–950 mm without padding, a tabletop inclination of +25°/−25°, lateral tilt of 15°, back-plate movement of +60°/−50° and leg-plate movement of 0°/90°. It lists a 155 kg maximum overall load and an optional longitudinal shift of 290 mm. These figures apply to the brochure's equipment description; validate the exact version and conditions for the offered table.
Keling lists 750–950 mm table-height adjustment, Trendelenburg of at least 20°, reverse Trendelenburg of at least 15°, and lateral tilt of at least 15° in each direction for the 3001 Series. It says height, tilt, headboard and backboard controls are accessible from either side. The series page also states a ±50 mm height tolerance; preserve the manufacturer's wording and verify the current technical sheet when a minimum or maximum is important.
For the MT600, Zhenghua publishes a length of at least 2,000 mm, width of 500 mm, lowest tabletop height of at most 670 mm and 300 mm elevation range. It lists Trendelenburg and reverse Trendelenburg, lateral tilt, head, back and leg plate movements, plus kidney bridge elevation. Confirm the required angles and how the manufacturer defines them from the latest product documentation.
Do not treat similar numbers as proof that two tables are equivalent. The measured height may be specified with or without padding; “maximum load” may have model-specific conditions; and motion ranges may use different reference positions. Ask for the relevant technical sheet and clarify tolerances, operating state, configuration and any limitation that affects the tender. The clinicians and biomedical engineers responsible for the project should decide which criteria are mandatory and how proposed evidence is evaluated.
Prepare an accessory schedule separately from the base-table request. Identify required head support, leg plates, arm supports, positioning accessories, restraints, mattress or padding, side-rail attachments, transfer equipment and any specialty components. State quantities and, where known, manufacturer references. Ask the written offer to mark each requested item as included, optional, unavailable or requiring a separate review.
This matters because the official Betaclassic brochure describes 1118.01B0 without head rest and leg plates, while listing several optional items and a distinct 1118.01K0 variant with longitudinal shift. A photo of a table in a particular position does not define the supplied package. Likewise, the Keling 3001 Series name does not resolve which suffix or tabletop configuration is offered, and a general MT600 description does not identify every accessory in a specific quote.
Map the accessory schedule to procedures and approved positioning needs with the responsible theatre team. Check attachment interfaces and compatibility with the exact table, not only with a manufacturer family name. If the requirement is specialised, ask for a manufacturer document or written confirmation identifying the supported configuration. Do not infer that an accessory is included because it appears in a brochure, illustration or demonstration setup.
For multiple theatres, assign accessories to each room and distinguish shared or spare sets. Request an itemised proposal with quantities, reference codes and exclusions. This makes it possible for procurement, users and biomedical engineering to assess the same package and reduces ambiguity when equipment is received.
State the imaging workflow and equipment identity in the enquiry. Tell Franance whether the table must be evaluated for C-arm use, specify the required access region or movement, and include the imaging system's make/model and any approved theatre layout constraints. Ask for written confirmation that the exact table reference and accessory configuration support the requested arrangement.
Getinge's public Betaclassic page and brochure describe an optional longitudinal shift and the brochure gives its listed travel. The manufacturer's product page says this option enables C-arm usage. This is a useful model-specific fact, but it does not establish that the Franance-listed 1118.01B0 includes the option or meets every C-arm workflow. The brochure separately identifies the longitudinal-shift 1118.01K0 reference. Do not silently substitute that reference; ask for the exact table configuration and written offer.
The Keling and Zhenghua sources cited here do not, by themselves, establish compatibility with a particular imaging system or clinical workflow. Do not infer radiolucency, clear imaging access or compatibility from the phrase “operating table.” Request current technical drawings and written manufacturer evidence for the precise tabletop, accessories and imaging arrangement being proposed.
Have clinical, engineering and imaging teams review the complete setup and any accessory changes before procurement approval. The catalogue helps organise the enquiry; it does not determine clinical suitability or validate an equipment integration.
Translate the equipment schedule into reviewable requirements. Start with the specialties and room workflow, patient transfer method, table positions, tabletop sections, height needs, load requirements and accessories. Then check the room drawing, staff access, equipment placement and routes through doors, corridors, lifts and receiving areas. Request dimensions for the table as offered, plus packaging or handling information if receiving plans need it.
Ask the biomedical engineering team to review the operating mechanism, manufacturer instructions, maintenance tasks, inspection schedule, cleaning compatibility and availability of technical documentation for the exact model. Theatre users should evaluate controls and positioning arrangements through the approved institutional process. Procurement should check that the stated reference and all components match tender requirements. These reviews serve different purposes; no single brochure or catalogue card substitutes for them.
Hydraulic or manual operation should be assessed against the hospital's workflow, operator requirements, intended procedures and backup-power expectations. Getinge states that the Betaclassic does not depend on an external power source, while the cited Keling and Zhenghua pages describe mechanical/manual hydraulic tables. Verify these statements for the exact offer and ask about any powered accessories or separate site needs. Do not assume that the category description resolves every utility requirement.
For a project, include the site name, state, city, room count, quantities, construction status, access restrictions and requested timing. Identify installation, assembly, commissioning, user orientation, warranty and maintenance as separate scope questions. The public sources reviewed for these three products do not establish that Franance provides any particular project service or coverage; include it in the enquiry and obtain a written response.
Franance does not publish a fixed price or guaranteed delivery time for this category. The quotation depends on the exact manufacturer reference, selected variant, included tabletop sections and accessories, quantity, destination and requested project scope. A price for one base table cannot be compared fairly with another package that includes different sections, supports, delivery or technical services.
Send the approved equipment schedule, exact model or variant, accessory list, facility address and target procurement timeline. Include the destination state and city, receiving hours, offloading arrangements and access limitations. If a tender sets currency, validity, delivery basis, warranty or documentation requirements, state them so the response can address the same criteria. Ask the quotation to show price and currency, validity, included and excluded components, delivery estimate, taxes or charges, warranty wording and responsibilities for any requested installation or handover.
Do not use a foreign website price or a manufacturer's international product page as evidence of Nigerian stock, local distribution rights, delivery capacity or service terms. No such commercial terms are established by the technical pages cited in this guide. Franance will need to confirm the proposed terms for your specific enquiry. If an alternative model is offered, request a separate technical comparison and written acceptance rather than treating it as the original reference.
Ask for a written schedule naming the manufacturer, exact model/reference, selected options, tabletop sections, accessories, quantities and any documentation included. The quote should identify unresolved requirements, exclusions, alternatives and commercial assumptions. For Getinge Betaclassic, make clear whether the requested reference is 1118.01B0 or another version, and whether a longitudinal shift or optional accessories are included. For Keling, specify 3001, 3001A or 3001B once the intended version is determined. For Zhenghua, name MT600 and list the required movement and accessory criteria.
If delivery, assembly, commissioning, installation, user orientation or ongoing service is required, list each item as an explicit request. Ask who is expected to perform it, what is included, where it applies and what records or deliverables the facility should expect. Verify warranty coverage and exclusions against the written offer. The existence of a manufacturer product page does not mean those services are part of the local transaction.
At receipt, compare the delivered identity, reference, serial details, table sections and accessories with the accepted order and record discrepancies through the facility's process. Have qualified staff review the delivered documents and condition before institutional acceptance. This is procurement guidance rather than a clinical protocol; the facility remains responsible for the professional evaluation and acceptance requirements applicable to its equipment.
Choose the manufacturer reference from the hydraulic operating-table category or open its filtered record: Getinge Betaclassic 1118.01B0, Keling 3001 Series or Zhenghua MT600. Send the exact product name, model or variant and quantity.
Include the intended theatre use, mandatory table movements, sections and accessory references, imaging needs, site drawing or access information, facility contact, destination state and city, and any requested delivery or handover work. Attach the tender schedule or approved technical specification if available. Clearly distinguish mandatory requirements from preferences and identify acceptable alternatives only if your institution permits them.
Franance receives the request as a quote order and follows up by phone or email to clarify details. The website does not take online payment. Before agreeing, review the written offer for exact model, scope, price, validity, delivery assumptions, documents, warranty and responsibilities. Use the contact page to request a quotation; availability and terms remain subject to confirmation for your order.
Manufacturer-specific figures in this guide come from Getinge's Maquet Betaclassic product page, its technical brochure, Keling Medical's 3001 Series page and Shanghai Zhenghua's MT600 product page. Review the current instructions and technical records for the exact model and configuration before purchase.
The category contains only the three direct product assignments stated above at the time of review. It is not a full inventory of all products made by those companies. This guide does not claim product suitability, Nigerian stock, local authorization, registration, certification, price, delivery timing, installation, warranty, training or service coverage. Franance must confirm any proposed commercial or support terms in writing. The responsible hospital teams must assess equipment against their technical and procurement requirements.
The category has three direct assignments: Getinge Maquet Betaclassic reference 1118.01B0, Keling Medical 3001 Series and Shanghai Zhenghua MT600. Confirm the exact offered configuration and commercial terms in a Franance quotation.
No. Franance receives quote orders and follows up by phone or email to clarify the model, requirements and terms; the catalogue does not take online payment.
The three listed records are described as manual or mechanical hydraulic designs, but their operation and adjustments differ. Confirm the exact configuration from the manufacturer documents for the offered reference.
No. Getinge's brochure describes reference-specific configurations and optional accessories. For example, the listed 1118.01B0 configuration is described without head rest and leg plates; the quotation should itemise supplied and optional components.
No. Getinge describes optional longitudinal shift for Betaclassic, but imaging access depends on the exact table, configuration and workflow. Obtain written confirmation for the equipment combination being proposed.
Provide the receiving facility, state, city and access details. Franance must confirm the delivery arrangement, timing, charges and any handover scope in the specific written quotation.
Send the exact manufacturer reference, required table movements and accessories, quantity, theatre and access requirements, and destination in Nigeria. Franance will follow up by phone or email to clarify the quote order; no online payment is taken.
Request a quotationAdd the models you need to a quote order, or send us your equipment list.