Larger open-frame medical electrical isolation transformer with multiple copper windings

Confirm the exact product reference and supplied package with your quotation.

Bender

Buy Bender ES710/6300-GL 6.3 kVA Medical IT Isolation Transformer
in Nigeria.

Single-phase medical IT isolation transformer

Request a Franance quotation for the Bender ES710/6300-GL 6.3 kVA medical IT isolation transformer in Nigeria. Provide room classification, supply and output voltage, the connected-load schedule, and the required monitoring, alarm and distribution-panel scope. A transformer alone is not a complete IPS solution. Have a qualified electrical engineer size and validate the whole medical IT system, enclosure, protection, monitoring and installation for the project.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • 6,300 VA single-phase ES710 variant for medical IT systems
  • Bender article number B92090004
  • Manufacturer lists reinforced insulation, temperature sensing and screen winding for the ES710 family
  • Output voltage variant must be selected for the actual system design
  • Requires coordinated medical IT system, protection, monitoring and installation design
Bender ES710/6300-GL 6.3 kVA Medical IT Isolation Transformer specifications
ManufacturerBender
ModelES710/6300-GL
Article numberB92090004
Rated power6,300 VA
PhaseSingle phase
Frequency50–60 Hz
Nominal input230 V AC
Output variants230 V / 115 V AC, per ES710 technical data
Dimensions280 × 225 × 370 mm
Weight65 kg
ApplicationComponent for a medical IT system; not a complete IPS by itself

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

What role does the ES710/6300-GL play?

Bender describes the ES710 series as single-phase isolating transformers for designing medical IT systems. The datasheet says the windings are galvanically isolated, with reinforced insulation and an electrostatic screen connected to an insulated terminal for equipotential bonding. It cites IEC 61558-2-15 and IEC 60364-7-710.

Read more

How does it differ from the 4,000 VA variant?

Per Bender's product page, this model has article number B92090004, a total weight of 65 kg and copper weight of 26 kg. Its listed dimension values are 280, 225 and 370 mm for the first three columns, against 280, 200 and 370 mm and 59 kg for the ES710/4000-GL. Bender does not define the column labels on that page, so use the datasheet drawing for mounting.

Read more

What does the datasheet say about voltage and protection?

The terminal diagram shows a 230 V primary with 115 V and 230 V secondary terminals, and the series is rated for 50–60 Hz at up to 40 °C ambient. Bender states overload protection is not permitted when forming a medical IT system, so short-circuit protection is required. Open IP00 construction is standard, with IP23 enclosures available.

Read more

Buy Bender ES710/6300-GL 6.3 kVA Medical IT Isolation Transformer in Nigeria

The ES710/6300-GL (article no. B92090004) is the 6,300 VA single-phase transformer in the ES710 series from Bender. Franance lists it in the medical IT isolation transformer category. A transformer alone is not a complete isolated power system.

What role does the ES710/6300-GL play?

Bender describes the ES710 series as single-phase isolating transformers for designing medical IT systems. The datasheet says the windings are galvanically isolated, with reinforced insulation and an electrostatic screen connected to an insulated terminal for equipotential bonding. It cites IEC 61558-2-15 and IEC 60364-7-710.

How does it differ from the 4,000 VA variant?

Per Bender's product page, this model has article number B92090004, a total weight of 65 kg and copper weight of 26 kg. Its listed dimension values are 280, 225 and 370 mm for the first three columns, against 280, 200 and 370 mm and 59 kg for the ES710/4000-GL. Bender does not define the column labels on that page, so use the datasheet drawing for mounting.

What does the datasheet say about voltage and protection?

The terminal diagram shows a 230 V primary with 115 V and 230 V secondary terminals, and the series is rated for 50–60 Hz at up to 40 °C ambient. Bender states overload protection is not permitted when forming a medical IT system, so short-circuit protection is required. Open IP00 construction is standard, with IP23 enclosures available.

What should a Nigerian buyer confirm before ordering?

Have a qualified electrical engineer confirm that 6.3 kVA suits your connected load, plus the room classification, selected output voltage, enclosure, protection, insulation monitoring and alarms. Check the space and floor loading for a 65 kg unit. Franance has not verified Nigerian stock, price, approval, warranty, delivery, installation or service for this item, and this guide is not electrical design advice.

How can I request a quote in Nigeria?

Add the ES710/6300-GL to Franance's quote cart at /quote-order.html. State the quantity, your Nigeria destination, supply and output voltage, enclosure needs and the wider medical IT scope. This is a quotation request with no online payment, and availability is not confirmed at this stage. Franance follows up with a written quotation.

Manufacturer source: https://www.bender-uk.com/products/system-components/isolating-transformer-es710/

Related links: Bender products · Relevant product category · Request a quotation

Common questions

What role does the ES710/6300-GL play?

Bender describes the ES710 series as single-phase isolating transformers for designing medical IT systems, with galvanically isolated windings, reinforced insulation and an electrostatic screen.

How does it differ from the 4,000 VA variant?

Article number B92090004, total weight 65 kg and dimension values 280, 225 and 370 mm, against 59 kg and 280, 200 and 370 mm for the ES710/4000-GL. Column labels are not defined on the product page.

What does the datasheet say about voltage and protection?

A 230 V primary with 115 V and 230 V secondary terminals and 50–60 Hz at up to 40 °C ambient. Overload protection is not permitted in a medical IT system, so short-circuit protection is required.

What should a Nigerian buyer confirm before ordering?

That 6.3 kVA suits the load, plus room classification, output voltage, enclosure, protection, monitoring and alarms, and floor loading for 65 kg. Nigerian stock, price, approval, warranty, delivery, installation and service are not verified.

How can I request a quote in Nigeria?

Add the item to the Franance quote cart at /quote-order.html with quantity, Nigeria destination, voltages and enclosure needs. There is no online payment and availability is not confirmed; Franance follows up with a written quotation.

Request your Bender ES710/6300-GL medical isolation transformer quotation from Franance.

Add Bender ES710/6300-GL 6.3 kVA Medical IT Isolation Transformer (ES710/6300-GL (article no. B92090004)) to the Franance quote cart with quantity, destination and required configuration. Franance will confirm the offered specification and terms in writing.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Larger open-frame medical electrical isolation transformer with multiple copper windings

Find equipment.

View cart