Open-frame electrical isolation transformer with copper windings and terminal block

Confirm the exact product reference and supplied package with your quotation.

Bender

Buy Bender ES710/4000-GL 4 kVA Medical IT Isolation Transformer
in Nigeria.

Single-phase medical IT isolation transformer

Request a Franance quotation for a Bender ES710/4000-GL 4 kVA medical IT isolation transformer in Nigeria. Send the room classification, electrical design, supply/output voltage, load schedule and required IPS panel scope. This transformer is one component of a medical IT system; it does not independently provide a complete isolated power panel, insulation monitoring, alarms or installation. Have a qualified electrical engineer verify the full design against applicable standards and site requirements.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • 4,000 VA single-phase ES710 variant for medical IT systems
  • Bender article number B92090002
  • Manufacturer lists reinforced insulation, temperature sensing and screen winding for the ES710 family
  • Output voltage variant must be selected for the actual system design
  • Requires coordinated medical IT system, protection, monitoring and installation design
Bender ES710/4000-GL 4 kVA Medical IT Isolation Transformer specifications
ManufacturerBender
ModelES710/4000-GL
Article numberB92090002
Rated power4,000 VA
PhaseSingle phase
Frequency50–60 Hz
Nominal input230 V AC
Output variants230 V / 115 V AC, per ES710 technical data
Dimensions280 × 200 × 370 mm
Weight59 kg
ApplicationComponent for a medical IT system; not a complete IPS by itself

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

What is the ES710/4000-GL designed for?

Bender describes the ES710 series as single-phase isolating transformers for the design of medical IT systems. The datasheet states compliance with IEC 61558-2-15 and IEC 60364-7-710 requirements, reinforced insulation, and an electrostatic screen between the windings that is brought out to an insulated terminal.

Read more

Which figures does Bender list for this variant?

The product page gives article number B92090002, a total weight of 59 kg, and dimension columns of 280, 200 and 370 mm for the first three columns, with copper weight of 24 kg. The page does not define the column labels, so check the datasheet drawing. The datasheet shows a 230 V primary, 115 V and 230 V secondary terminals, and a 50–60 Hz rating at up to 40 °C ambient.

Read more

What protection and installation points does the datasheet raise?

The datasheet says overload protection is not permitted when forming a medical IT system, so short-circuit protection is required, and temperature monitoring uses built-in sensors. It lists open (IP00) construction, with IP23 steel enclosures available, and notes the transformers are for dry locations. A qualified electrical engineer must design the full system.

Read more

Buy Bender ES710/4000-GL 4 kVA Medical IT Isolation Transformer in Nigeria

The ES710/4000-GL (article no. B92090002) is the 4,000 VA single-phase member of the ES710 series from Bender. It is listed in the medical IT isolation transformer category. It is one component of a medical IT system, not a complete isolated power panel.

What is the ES710/4000-GL designed for?

Bender describes the ES710 series as single-phase isolating transformers for the design of medical IT systems. The datasheet states compliance with IEC 61558-2-15 and IEC 60364-7-710 requirements, reinforced insulation, and an electrostatic screen between the windings that is brought out to an insulated terminal.

Which figures does Bender list for this variant?

The product page gives article number B92090002, a total weight of 59 kg, and dimension columns of 280, 200 and 370 mm for the first three columns, with copper weight of 24 kg. The page does not define the column labels, so check the datasheet drawing. The datasheet shows a 230 V primary, 115 V and 230 V secondary terminals, and a 50–60 Hz rating at up to 40 °C ambient.

What protection and installation points does the datasheet raise?

The datasheet says overload protection is not permitted when forming a medical IT system, so short-circuit protection is required, and temperature monitoring uses built-in sensors. It lists open (IP00) construction, with IP23 steel enclosures available, and notes the transformers are for dry locations. A qualified electrical engineer must design the full system.

What should a Nigerian buyer confirm before ordering?

Confirm the room classification, load schedule, supply and output voltage, enclosure type, and which monitoring, alarm and distribution equipment completes the medical IT system. Check that 4 kVA suits your load. Franance has not verified Nigerian stock, price, approval, warranty, delivery, installation or service for this transformer, and this guide is not electrical design advice.

How can I request a quote in Nigeria?

Add the ES710/4000-GL to Franance's quote cart at /quote-order.html. State the quantity, your Nigeria destination, supply and output voltage, enclosure needs and the wider medical IT scope. This is a quotation request with no online payment, and availability is not confirmed at this stage. Franance follows up with a written quotation.

Manufacturer source: https://www.bender-uk.com/products/system-components/isolating-transformer-es710/

Related links: Bender products · Relevant product category · Request a quotation

Common questions

What is the ES710/4000-GL designed for?

Bender describes the ES710 series as single-phase isolating transformers for the design of medical IT systems, with reinforced insulation and an electrostatic screen between windings.

Which figures does Bender list for this variant?

Article number B92090002, total weight 59 kg, dimension values 280, 200 and 370 mm (column labels undefined on the page), a 230 V primary, 115 V and 230 V secondary terminals and 50–60 Hz.

What protection and installation points does the datasheet raise?

Overload protection is not permitted in a medical IT system, so short-circuit protection is required. Construction is open (IP00) with IP23 enclosures available, for dry locations. A qualified engineer must design the system.

What should a Nigerian buyer confirm before ordering?

Room classification, load, voltages, enclosure and the monitoring, alarm and distribution equipment needed. Nigerian stock, price, approval, warranty, delivery, installation and service are not verified.

How can I request a quote in Nigeria?

Add the item to the Franance quote cart at /quote-order.html with quantity, Nigeria destination, voltages and enclosure needs. There is no online payment and availability is not confirmed; Franance follows up with a written quotation.

Request your Bender ES710/4000-GL medical isolation transformer quotation from Franance.

Add Bender ES710/4000-GL 4 kVA Medical IT Isolation Transformer (ES710/4000-GL (article no. B92090002)) to the Franance quote cart with quantity, destination and required configuration. Franance will confirm the offered specification and terms in writing.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Open-frame electrical isolation transformer with copper windings and terminal block

Find equipment.