Computed tomography scanner with patient table

Confirm the exact product reference and supplied package with your quotation.

Philips Healthcare

Buy Philips CT 5300 128-Slice CT Scanner
in Nigeria.

Computed tomography scanner

Request a quotation for the Philips CT 5300 computed tomography scanner in Nigeria. Philips lists this platform with up to 128 slices, a 72 cm bore and AI-enabled CT Smart Workflow capabilities. Tell Franance the facility, destination, intended workload, room-readiness stage, required applications and project services so the offered configuration and commercial terms can be reviewed with you.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • Philips lists up to 128 slices, 40 mm coverage and a 72 cm bore for the CT 5300 platform
  • Manufacturer specifications list an 80 kW generator, 8 MHU tube capacity and up to 0.35-second rotation
  • CT Smart Workflow includes manufacturer-described tools for scan preparation, acquisition and reconstruction; option and licence inclusion must be confirmed
Philips CT 5300 128-Slice CT Scanner specifications
ManufacturerPhilips
ModelCT 5300 (HC728285)
Equipment classComputed tomography scanner
SlicesUp to 128 (Philips published specification)
DetectorNanoPanel Precise (Philips published product information)
Bore size72 cm
Coverage40 mm
Generator power80 kW
Tube capacity8 MHU
Rotation speedUp to 0.35 seconds
Reconstruction speedUp to 100 images per second
Clinical applicationsPhilips lists cardiac, bariatric, interventional and trauma applications; offered applications require confirmation

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

Where can I buy a Philips CT 5300 in Nigeria?

Franance lists the Philips CT 5300 product in the 128-slice CT scanner category in Nigeria, under the Philips CT equipment range. These pages identify the catalogue entry and its taxonomic context. They do not establish current stock, local registration, a final configuration or delivery promise.

Read more

What is the Philips CT 5300 128-slice scanner?

The CT 5300 is a Philips computed tomography scanner. Philips describes the platform as combining detector and reconstruction technologies with CT Smart Workflow capabilities intended to support the steps around scan preparation, acquisition and image reconstruction. Its public product page names applications including cardiac, bariatric, interventional and trauma imaging. These are manufacturer descriptions of the platform; they do not mean every software module, licence, accessory, protocol or service is included in every system offered in every market.

Read more

What CT 5300 specifications should a buyer compare?

Philips' public product specifications list up to 128 slices, a 72 cm bore, 40 mm coverage, an 80 kW generator, an 8 MHU tube capacity, rotation up to 0.35 seconds and reconstruction speed up to 100 images per second. Philips also identifies the NanoPanel Precise detector. These are manufacturer-published reference specifications. Ask the supplier to document the exact specifications for the configuration being quoted and to distinguish standard equipment from optional components or software.

Read more

Buy the Philips CT 5300 128-Slice CT Scanner in Nigeria

Buy the Philips CT 5300 in Nigeria through a configuration-specific quotation. Philips lists this computed tomography system at up to 128 slices, with a 72 cm bore, 80 kW generator and CT Smart Workflow tools. A headline specification does not determine the software, licences, service terms, room work or regulatory documents in a particular offer. Franance can review your enquiry and follow up by phone or email; the product is ordered by quotation, with no online payment or automatic confirmation of Nigerian stock, price, delivery or installation.

Where can I buy a Philips CT 5300 in Nigeria?

Franance lists the Philips CT 5300 product in the 128-slice CT scanner category in Nigeria, under the Philips CT equipment range. These pages identify the catalogue entry and its taxonomic context. They do not establish current stock, local registration, a final configuration or delivery promise.

To request a quotation, identify your hospital, diagnostic centre or project, the destination city and state, required quantity, expected patient workload and timeline. Tell Franance whether you need a new scanner project, replacement equipment, or a technical and commercial assessment of defined requirements. Include your name, work email or phone number and the best contact time. Franance follows up to clarify the requirement and prepare a written offer; sending a request is not the same as completing an online purchase.

If a public procurement, donor-funded project or private tender is involved, share the approved technical requirements and bid schedule. Ask the proposed system to be mapped line by line to mandatory and preferred requirements, with deviations and assumptions stated explicitly. For a developing project, say which decisions are still open rather than treating a preliminary enquiry as a final configuration. The purchasing team should retain the documents used to compare offers and record who approved the technical, clinical, engineering and financial requirements.

What is the Philips CT 5300 128-slice scanner?

The CT 5300 is a Philips computed tomography scanner. Philips describes the platform as combining detector and reconstruction technologies with CT Smart Workflow capabilities intended to support the steps around scan preparation, acquisition and image reconstruction. Its public product page names applications including cardiac, bariatric, interventional and trauma imaging. These are manufacturer descriptions of the platform; they do not mean every software module, licence, accessory, protocol or service is included in every system offered in every market.

Philips identifies a NanoPanel Precise detector and Precise Image reconstruction among the system's technologies. Other named features include Precise Cardiac and camera-assisted Precise Position. Before making a feature part of the purchase requirement, ask Philips or the supplier to identify its exact availability for the offered hardware and software version, whether it requires an additional option or licence, and any prerequisites. Confirm which workstations, displays, patient supports, injector interfaces, accessories and protocol packages are included. The equipment list and signed configuration schedule should resolve these details.

For procurement, “128-slice” is a starting description, not a complete performance specification. Detectors, acquired data, reconstructed images, coverage, rotation, reconstruction speed and option packages describe different characteristics. A buyer should state which performance matters for the facility's intended services and ask for evidence against that requirement. Do not assume that two systems carrying the same slice-count label have identical hardware, image outputs, workflow or clinical suitability.

What CT 5300 specifications should a buyer compare?

Philips' public product specifications list up to 128 slices, a 72 cm bore, 40 mm coverage, an 80 kW generator, an 8 MHU tube capacity, rotation up to 0.35 seconds and reconstruction speed up to 100 images per second. Philips also identifies the NanoPanel Precise detector. These are manufacturer-published reference specifications. Ask the supplier to document the exact specifications for the configuration being quoted and to distinguish standard equipment from optional components or software.

| Published specification | What to confirm for the quoted system |
| --- | --- |
| Up to 128 slices and 40 mm coverage | System generation and exact acquisition and reconstruction configuration |
| 72 cm bore | Current technical documentation, positioning accessories and room/access implications |
| 80 kW generator and 8 MHU tube capacity | Offered component configuration and the facility's electrical and cooling requirements |
| Rotation up to 0.35 seconds and reconstruction up to 100 images per second | Applicable software and operating conditions, and the workload for which the figures are relevant |

The values in the table should be treated as questions to verify, not a guarantee for a specific quote. Manufacturers can revise product pages, configuration names and regional availability. Ask for the current technical data sheet, system configuration code and applicable product documentation. If a tender uses different terms for slice counts, coverage or reconstruction, ask the bidder to define each term and attach the supporting document. Record any deviations instead of translating unlike measures into a single score without technical review.

What CT 5300 specifications should a buyer compare? — review checklist
Published specificationConfirm for the offer
Up to 128 slices; 40 mm coverageExact system generation, acquisition and reconstruction details
72 cm boreCurrent technical document and room/access implications
80 kW generator; 8 MHU tubeOffered component configuration and facility utility requirements
Up to 0.35-second rotation; up to 100 IPSApplicable system version, protocol, software and workload requirements

How should I assess CT applications and AI workflow options?

Begin with services your facility is authorized and staffed to deliver. Have the radiology lead and relevant clinical users state their anticipated case mix, protocols, patient populations, throughput needs and referral workload. If cardiac or interventional imaging is planned, document the procedures and workflow requirements with qualified clinical staff. Then ask the supplier to map each requirement to the exact CT 5300 software, licence, accessory and service package proposed.

Philips describes Precise Image as an AI-based reconstruction tool and cites performance outcomes from defined evaluation conditions. Philips' disclaimers say actual results depend on the clinical task, patient size and anatomy and that a radiologist and physicist should determine an appropriate dose for diagnostic image quality. Do not turn a manufacturer study percentage into a promise of dose reduction for your patients or a substitute for local protocol validation. Any evaluation should use approved clinical, quality assurance and radiation-safety procedures and the facility's professional oversight.

For each named feature, request its included status, licence basis, software version, compatible protocols, workstation requirements, user training and any network or remote-service prerequisites. Ask whether a feature requires an active support contract, connectivity or data transfer, and who is responsible for configuration. Clarify where patient information may travel and which privacy and cybersecurity controls apply before enabling remote connectivity. If the facility plans teleradiology or enterprise workflow integration, involve its IT and information-governance staff early and identify the interfaces, responsibilities and recurring fees in writing.

What should a Nigerian facility check before installing a CT scanner?

A CT scanner is a site and infrastructure project as well as an equipment purchase. Before accepting a delivery schedule, have qualified local professionals assess the proposed room, structural capacity, shielding design, controlled areas, access route and installation sequence. The room layout must be coordinated with the scanner, operator console, patient movement, service access and supporting equipment. A product listing cannot determine whether an existing room is suitable or compliant.

Request manufacturer-specific site-planning documentation for the exact proposed configuration. Ask the supplier to identify electrical supply characteristics, grounding, cooling and environmental conditions, network needs, room dimensions, floor loading and clearances. Confirm the route from vehicle unloading to the installation room, including doorways, lifts, corridors, ramps and any temporary works. Clarify who conducts the survey, who approves drawings, what work is excluded from the equipment price, and what must be complete before installation begins.

Radiation protection planning should be led by appropriately qualified professionals and follow applicable Nigerian requirements. The IAEA's SSG-46 covers radiation protection and safety in medical uses of ionizing radiation, including diagnostic radiology. It is a technical reference, not a site-specific design or a substitute for national rules. Establish who reviews shielding, acceptance testing, quality control, radiation surveys, operating procedures and required records. Confirm that the facility's responsible staff and competent service personnel will be available for commissioning and handover.

The project plan should also cover staff training, image storage, backup, uptime planning and service access. Ask what acceptance criteria will be used, how faults are escalated, which spare parts and response arrangements are available locally, and how scheduled maintenance is handled. The written quotation should make responsibility clear among the supplier, facility, construction contractor, IT team and any independent engineer. Never assume installation, training or ongoing service is included simply because a scanner is listed for quotation.

Which documents and regulatory details should I request?

Ask for current manufacturer documentation tied to the precise model and configuration: technical data, product and option list, instructions for use, site-planning requirements, electrical and environmental specifications, cybersecurity information relevant to connected functions, and warranty and service terms. Where an application or software option is proposed, request the document that identifies it and its prerequisites. Ensure the model code and configuration identifiers in those documents match the quotation.

For Nigerian procurement, ask the seller to identify applicable product-registration or import documentation and the responsible party for supplying it. NAFDAC publishes guidance on medical-device registration in Nigeria. A catalogue page, manufacturer product page or quote request does not prove that a specific unit has the required registration or that a particular transaction meets all regulatory requirements. Verify documents directly with the appropriate authority or a qualified Nigerian regulatory professional, especially where a tender or deployment timeline depends on them.

The technical evaluation file should capture the requirements, submitted evidence, compliance response, exceptions, clarification questions and decision record. Separate verified manufacturer specifications from supplier assertions and project assumptions. Ask for a list of included and excluded items, delivery terms, installation responsibilities, training, acceptance tests, warranty start point, service coverage, planned maintenance and end-of-life support. If documents conflict, request a written resolution before award or order placement.

What should the CT 5300 quotation include?

A useful quote should identify the Philips CT 5300 model, configuration code, generation, hardware, software, licences, workstations, accessories and quantities. It should state the included protocols or applications requested, any separately priced options, and the documentation that supports stated performance. Require a compliance matrix against your approved specification, with every deviation and assumption visible. If the proposed system is not exactly the model requested, the supplier should explain the difference rather than relying on a family name.

| Quotation area | Written confirmation to request |
| --- | --- |
| Scanner and configuration | Model, configuration codes, software, licences, compatible components and quantities |
| Site and delivery | Destination, access, site survey, room and utilities prerequisites, delivery assumptions |
| Project services | Installation, commissioning, applications training, acceptance and handover responsibilities |
| Commercial and support | Price basis, availability, taxes or other charges, warranty, maintenance, coverage and exclusions |

Ask the seller to separate the equipment price from site works and other project costs, and state the currency and validity period. Have the offer explain lead-time assumptions and the events that can change them. Ask what happens if the site is not ready at delivery, whether storage or repeat visits incur charges, and what dependencies rest with the facility. For support, seek written coverage hours, response process, preventive maintenance, parts terms and the responsible service organisation. The answers should be specific to your destination and contract, not broad statements of capability.

Franance can review the information you submit and follow up to clarify the requested scope. Any offer should be assessed by the facility's procurement, finance, radiology, biomedical engineering, IT and project teams as appropriate. The listing is not a substitute for tender review, technical evaluation or approval of a major capital project.

What should the CT 5300 quotation include? — review checklist
Quotation itemWritten confirmation to request
Scanner and configurationModel, codes, generation, software, licences and compatible components
Site and deliveryDestination, access, room, utilities, shielding and delivery assumptions
Project servicesInstallation, commissioning, applications training and handover responsibilities
Commercial and supportPrice basis, availability, warranty, maintenance, service coverage and exclusions

What affects the price of a Philips CT 5300 in Nigeria?

The price depends on the exact hardware and software configuration, optional applications and licences, included accessories, delivery destination, import and logistics assumptions, site works, installation and commissioning scope, training, warranty and service terms. Exchange rates, supplier availability and project timing may also affect a written commercial offer. Because the website is a quotation catalogue rather than an online checkout, it does not publish a binding price or guarantee stock for the CT 5300.

For comparable offers, send every bidder the same approved requirement schedule and ask them to separate included items, options, exclusions and assumptions. Compare total project scope and ongoing costs, not only the scanner line. Request the currency, price validity, payment milestones, tax and delivery basis, lead-time assumptions and any conditions that could change the total. If you need an indicative budget, state the project stage and ask Franance what information is required before an estimate can be prepared. No price should be treated as final until stated in a valid written quotation and accepted under its terms.

How do I request a Philips CT 5300 quotation from Franance?

Use the Philips CT 5300 product page or contact Franance about a CT 5300 quote. Include your facility name, contact person, destination city and state, quantity, project timeline, expected service scope and procurement stage. Share the model or approved specification, application requirements, room-readiness status, available site plans and preferred installation window. Do not include patient-identifiable data in a general quote enquiry.

Franance can then follow up by phone or email to clarify the enquiry. Ask the written proposal to identify the exact system and configuration, available options, documents, current availability, price basis, delivery assumptions, installation and training responsibilities, service terms, exclusions and validity period. If you are comparing several systems, provide the same requirement list for each and ask suppliers to state deviations explicitly. A request is a quotation order: there is no online purchase or payment through this page.

Common questions

Is the Philips CT 5300 a 128-slice CT scanner?

Philips lists the CT 5300 at up to 128 slices. The proposed model and current technical documentation should identify the exact acquisition and reconstruction configuration being quoted.

Does every CT 5300 quotation include all listed software and applications?

No. Philips describes system capabilities, but the exact software, licences, workstations, protocols and clinical applications included in a particular configuration must be itemised in the written offer.

Does this page confirm that a CT 5300 is in stock in Nigeria?

No. Submit a quote order so Franance can follow up and confirm current availability, configuration, destination-specific delivery assumptions and commercial terms.

Can Franance confirm the CT 5300 is registered with NAFDAC?

The catalogue entry is not evidence of registration. Ask for the applicable product and transaction documentation and verify regulatory questions with NAFDAC or a qualified Nigerian regulatory professional.

Can I buy the Philips CT 5300 online from Franance?

No. Franance accepts quotation orders and follows up by phone or email; the website does not take online payment for this scanner.

Request your Philips CT 5300 quotation from Franance.

Send the facility name, destination city and state, quantity, required CT applications, expected workload, preferred configuration, project stage, room and utility information, integration requirements, requested installation or training and timeline. Franance can follow up by phone or email to review the enquiry. Ask the written quotation to identify the exact CT 5300 model and configuration, software and licences, regulatory documentation, availability, price basis, delivery assumptions, included services and exclusions.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Computed tomography scanner with patient table

Find equipment.

View cart