Class II biological safety cabinet with clear front sash, stainless-steel work area and support stand

Confirm the exact product reference and supplied package with your quotation.

Esco Lifesciences

Buy Esco Airstream AC2-4E8 Class II Biological Safety Cabinet
in Nigeria.

Class II Type A2 biological safety cabinet

Request a quotation from Franance for the Esco Airstream AC2-4E8 Class II biological safety cabinet in Nigeria. Confirm the cabinet variant, electrical supply, installation opening, room layout, exhaust arrangements and qualification scope required by your laboratory.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • Manufacturer-listed 4 ft / 1.2 m Airstream E-Series model
  • Class II Type A2 product family
  • Manufacturer-listed 220–240 VAC, 50/60 Hz model
Esco Airstream AC2-4E8 Class II Biological Safety Cabinet specifications
ManufacturerEsco Lifesciences
Product familyAirstream Class II Biological Safety Cabinet, E-Series
Model / itemAC2-4E8; item 2010621
Nominal width4 ft / 1.2 m
Cabinet classClass II Type A2, as identified in manufacturer technical literature
Electrical version220–240 VAC, 50/60 Hz
External dimensions1340 mm W; 767 mm D without arm rest or 823 mm D with arm rest; 1400 mm H, technical-table values
Usable work area0.56 m2, manufacturer technical-table value
Site verificationConfirm exact variant, room clearance, services, exhaust requirements and qualification scope

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

Where can I buy the Esco AC2-4E8 in Nigeria?

Review the Esco Airstream AC2-4E8 product listing, the Esco equipment page, and the biological safety cabinet category. The Esco-filtered cabinet listing connects this model to other Esco equipment in Franance’s catalogue. A catalogue listing does not establish stock, local certification, a delivery date or that a particular configuration is currently offered in Nigeria.

Read more

What is the Airstream AC2-4E8 designed to do?

Esco describes the Airstream Gen 3 Class II biological safety cabinet as providing operator, product and environmental protection when used as designed. The AC2-4E8 is part of the E-Series, with glass sidewalls, a multi-piece autoclavable work tray and a nominal 4 ft / 1.2 m size. Esco lists an airflow design with a DC-ECM blower and ULPA filtration for this product family. Its product page states filtration performance of 99.999% at 0.1–0.3 micrometres under the cited standards. Confirm the exact filter, cabinet and certification documents for the quoted unit.

Read more

What exactly does the AC2-4E8 model code identify?

Esco’s Gen 3 product page lists item 2010621 as AC2-4E8, an Airstream Class II E-Series cabinet with nominal width 4 ft / 1.2 m, on the 220–240 VAC, 50/60 Hz model table. The product record is for this Gen 3 AC2-4E8. Esco also lists models with related names such as AC2-4E8-TU in its separate Airstream Plus line, and a later G4 generation uses a model code that adds “G4.” These are not interchangeable model codes. The quote should match the exact requested AC2-4E8 generation and item number, and should explicitly describe any proposed substitute.

Read more

Buy Esco Airstream AC2-4E8 Class II Biological Safety Cabinet in Nigeria

To buy an Esco Airstream AC2-4E8 Class II biological safety cabinet in Nigeria, verify the exact Airstream generation, cabinet width, electrical variant and installation requirements before requesting a quote. Esco lists AC2-4E8 as a 4 ft / 1.2 m Airstream Gen 3 E-Series cabinet, item 2010621, for 220–240 VAC at 50/60 Hz. Franance processes quote orders rather than online purchases. Share your risk assessment, room layout, work process, service connections, delivery location and qualification needs so the proposed cabinet can be reviewed against the facility’s requirements.

Where can I buy the Esco AC2-4E8 in Nigeria?

Review the Esco Airstream AC2-4E8 product listing, the Esco equipment page, and the biological safety cabinet category. The Esco-filtered cabinet listing connects this model to other Esco equipment in Franance’s catalogue. A catalogue listing does not establish stock, local certification, a delivery date or that a particular configuration is currently offered in Nigeria.

Franance accepts a quote order, then contacts the buyer by phone or email to clarify the requested package. Include the model code AC2-4E8, item code 2010621 if relevant, required 220–240 V supply, laboratory use, width and location. State whether the request includes a base stand, service fixtures, installation, on-site certification, training or recurring service. If you are replacing an older cabinet, provide its dimensions and current exhaust arrangement so the site can be assessed before a proposal is prepared.

Where can I buy the Esco AC2-4E8 in Nigeria? — review checklist
Quote detailWhat to specify
Cabinet identityAC2-4E8 Gen 3, item 2010621; verify exact generation
Use and riskProcedure, agents, risk assessment and required protection
Room designLayout, HVAC, exhaust, clearances and delivery route
PackageStand, fixtures, filters, alarms, installation and field certification
HandoverTraining, acceptance tests, documents, warranty and service

What is the Airstream AC2-4E8 designed to do?

Esco describes the Airstream Gen 3 Class II biological safety cabinet as providing operator, product and environmental protection when used as designed. The AC2-4E8 is part of the E-Series, with glass sidewalls, a multi-piece autoclavable work tray and a nominal 4 ft / 1.2 m size. Esco lists an airflow design with a DC-ECM blower and ULPA filtration for this product family. Its product page states filtration performance of 99.999% at 0.1–0.3 micrometres under the cited standards. Confirm the exact filter, cabinet and certification documents for the quoted unit.

A Class II BSC is selected through a laboratory risk assessment and validated operating method. It is not a substitute for training, safe technique, maintenance, room suitability or certification. A cabinet’s nominal class does not make every microbiological, chemical or toxic-material procedure appropriate for use inside it. Ask your biosafety officer or qualified safety professional to establish which cabinet type, exhaust approach and user practices fit the agents and work involved.

Do not treat a BSC as a chemical fume hood. The specific cabinet configuration and the substances used determine whether volatile chemicals or radionuclides are within an allowed application. If the work involves hazardous chemicals, volatile compounds, toxic powders or other special hazards, name them in the request and obtain a written suitability statement from Esco or a qualified safety professional. Do not rely on generic product marketing to authorize a procedure.

What exactly does the AC2-4E8 model code identify?

Esco’s Gen 3 product page lists item 2010621 as AC2-4E8, an Airstream Class II E-Series cabinet with nominal width 4 ft / 1.2 m, on the 220–240 VAC, 50/60 Hz model table. The product record is for this Gen 3 AC2-4E8. Esco also lists models with related names such as AC2-4E8-TU in its separate Airstream Plus line, and a later G4 generation uses a model code that adds “G4.” These are not interchangeable model codes. The quote should match the exact requested AC2-4E8 generation and item number, and should explicitly describe any proposed substitute.

The “E” series describes the glass-sidewall construction in Esco’s product family. The numeric width segment identifies the 4 ft / 1.2 m model size. The “8” electrical model appears in Esco’s 220–240 V, 50/60 Hz table; the separately listed “9” variants are 110–120 V. For Nigerian procurement, ask the seller to verify the nameplate and current factory configuration rather than inferring supply details from a similar-looking model.

Ask for the model’s technical data sheet and certificate applicable to the offered unit. Esco’s Gen 3 product page identifies the AC2-4E8 and lists certificates for AC2-4E8, but a general line page or a certificate for another suffix does not prove that a particular cabinet is supplied with an identical configuration or current certification. Require the documents to match the exact model, serial number and destination as applicable.

How should I choose the 4 ft cabinet width and layout?

The AC2-4E8 is a nominal 4 ft / 1.2 m cabinet. Select working width based on the largest procedure, the number of operators, equipment placed inside and the required clearance for hands and materials. The width is not equal to usable work surface across the entire cabinet: sidewalls, grilles, sash and equipment reduce the practical zone. Ask the manufacturer for the drawing and usable work-area dimensions for the exact model before laying out instruments or planning a bench.

Map the room around the cabinet, not just its outside dimensions. Consider the route from the delivery point to the laboratory, door and lift clearances, ceiling height, wall proximity, nearby doors, supply-air diffusers, traffic and other equipment that can disturb the cabinet’s airflow. Confirm the clearance needed for exhaust or service access and for routine filter and electrical maintenance. The installation requirements should be reviewed with a qualified cabinet installer and site engineer.

List the devices and consumables used in the procedure, such as microscopes, pipettes, racks, waste containers and small equipment. Ask the biosafety lead whether a 4 ft working area remains workable while keeping front and rear grilles open. Avoid overloading or obstructing airflow. If a stand, caster wheels, leveling feet, service fixtures or IV bar are required, request them as line items; Esco lists these accessories separately across its cabinet family.

What alarms, controls and filter features should I verify?

Esco identifies a Sentinel Gold microprocessor controller on its Gen 3 cabinet page. The manufacturer lists audible and visual alarms, a single-screen display of safety information and selectable Quickstart mode. The page also describes a DC-ECM blower and ULPA filtration. These are product-family descriptions; ask for the precise user interface, filter model, alarm set points, monitoring output and maintenance requirements for the cabinet actually offered.

Esco lists a nominal ULPA filter efficiency of 99.999% at 0.1–0.3 micrometres under the cited IEST standard, or a stated MPPS efficiency under EN 1822. Filter efficiency alone does not establish the protection of a cabinet in a particular room. Performance depends on cabinet integrity, airflow, installation, room conditions, loading and periodic certification. Request the factory documentation and any field-certification plan, including test scope and responsibility.

The Gen 3 page lists a DC-ECM blower and describes energy savings compared with an AC motor. Do not use a marketing comparison as an energy estimate for your room. Ask for the power draw, noise information, plug and circuit requirements from the technical data for AC2-4E8. If your lab requires a BMS alarm interface, remote monitoring or a special data record, state that before quote preparation and verify availability with Esco.

Does the AC2-4E8 require ducting or room exhaust?

The required exhaust arrangement depends on the exact cabinet type, installation method, room design and hazards in the laboratory. Do not assume that the AC2-4E8 can be placed anywhere or that its exhaust configuration is suitable for every containment plan. Ask Esco or a qualified cabinet specialist to specify whether the proposed configuration is recirculating, canopy-connected or otherwise configured, and what services and clearances it requires. If hazardous vapours are part of the work, get explicit confirmation of cabinet suitability and exhaust design before proceeding.

Before ordering, provide a room drawing, supply-air conditions, ceiling height, nearby ventilation outlets, intended exhaust connection and cabinet position. A site assessment should consider disturbances from doors, traffic, HVAC diffusers and cross-drafts. Installation and certification should follow the manufacturer instructions and relevant standards. The buyer should specify whether the quote includes delivery to final position, installation, airflow balancing, field certification and a certification report.

The cabinet’s product page refers to EN 12469 certification for the Airstream Gen 3 series. Verify that the documentation covers the exact AC2-4E8 model and the configuration supplied. A cabinet certificate does not replace commissioning checks or site certification after installation. Agree on acceptance criteria and who will perform the tests before placing the quote order.

What should I plan for electrical supply and maintenance?

Esco lists AC2-4E8 under a 220–240 VAC, 50/60 Hz model table. Confirm the facility supply, outlet, earthing, circuit protection and actual nameplate for the offered cabinet. Have a qualified electrical professional review the room, particularly where a generator or backup power system is used. A matching voltage label does not automatically make installation compliant or establish what plug and cable are included.

Ask for the cabinet’s service schedule and filter replacement plan. Confirm the availability, model and lead time of replacement ULPA filters, prefilters and other service parts. Identify who will conduct field certification, what standards and tests will be applied and whether the technician is qualified for this exact model. These questions matter for lifecycle planning as much as the initial price, especially where laboratories must maintain scheduled recertification.

Specify whether the quote includes user training, cleaning and decontamination guidance, service documentation, calibration or certification. If your laboratory needs a certificate for a quality system, state the format and tests expected. Do not assume a certificate, IQ/OQ package, installation or warranty is included unless the written offer lists it. Have the biosafety officer and facilities team review the package before procurement.

What should Nigerian laboratories confirm before ordering?

Confirm the exact AC2-4E8 generation and item number, voltage and frequency, stand and accessories, filter set, delivery and installation scope. The manufacturer’s product page lists model options and accessories; it does not establish current Nigerian inventory, delivery schedule, local certification service, warranty or price. Ask Franance to confirm each point in writing for the proposed offer. If the quoted item is AC2-4E8-TU or AC2-4E8 G4, treat it as a different model and request a side-by-side technical comparison.

Discuss regulatory and facility requirements with the appropriate Nigerian authorities and qualified safety professionals for the actual use and transaction. NAFDAC’s medical-device registration guideline describes device registration and import documentation within its scope; this guide does not establish that a specific BSC is registered or that every laboratory cabinet follows the same regulatory path. The laboratory should also follow its biosafety and occupational-safety obligations.

Prepare a procurement checklist covering project use, room assessment, required width, utilities, exhaust method, accessory list, field certification, training and after-sales service. Ask the supplier to identify the party responsible for customs and documentation, delivery into the facility, unpacking, final placement and installation. Clarify warranty conditions and who will respond to an alarm, airflow failure or filter issue. This prevents a quote from treating “cabinet delivered” as equivalent to a commissioned containment workstation.

What does an Esco AC2-4E8 cost in Nigeria?

Franance uses quotation-based ordering and does not promise a public online price. Cost depends on the exact cabinet generation and electrical configuration, stand, service fixtures, delivery, installation, field certification, training, warranty and service. A quote for AC2-4E8 is not directly comparable to one for the Plus AC2-4E8-TU or G4 model unless the cabinet type, dimensions, power, filter and service scope are matched.

For an accurate offer, share the room location, risk assessment, exhaust approach, required accessories, acceptance tests, quantity and preferred delivery date. Ask for itemized pricing, price validity, availability, delivery conditions, installation assumptions and service exclusions. Franance will follow up by phone or email to clarify the quote order; the product page is not proof of stock or final price.

How do I request an Esco AC2-4E8 quote from Franance?

Visit the Esco AC2-4E8 product listing or contact Franance about the Airstream cabinet. Include item code 2010621, the intended laboratory procedure, nominal 4 ft size, voltage and frequency, service fixtures, stand, room drawing, exhaust design, destination city and state, delivery route, field certification and training requirements.

Franance will call or email to clarify the request and prepare a written quotation. Ask the offer to state the exact model and generation, electrical rating, accessories, certificate documents, delivery and installation, commissioning and certification, warranty, price, availability and service scope. The Esco brand page and biological safety cabinet category link the cabinet to related catalogue equipment.

Manufacturer references

- Esco Airstream Gen 3 Class II BSC E-Series product page - Esco Airstream Plus Class II BSC E-Series product page for comparison with the distinct TU model - NAFDAC medical-device registration guideline

Common questions

What size is Esco Airstream AC2-4E8?

Esco lists the Gen 3 E-Series AC2-4E8 at nominal 4 ft / 1.2 m and item 2010621. Confirm the latest drawing and working-area dimensions before site planning.

Is AC2-4E8 the same as AC2-4E8-TU or AC2-4E8 G4?

No. Esco lists these as different Airstream line or generation variants. Require the quotation to state the exact model and generation.

Can a biological safety cabinet be used as a fume hood?

Do not assume so. Have the intended agents and procedures assessed by a qualified biosafety professional and confirm the exact cabinet configuration and exhaust requirements.

Request your Airstream AC2-4E8 quotation from Franance.

Request a quotation from Franance for the Esco Airstream AC2-4E8 Class II cabinet in Nigeria. Include the exact generation and item code, procedure and risk assessment, voltage, room layout, exhaust, accessories, field certification, quantity and destination. Franance will follow up by phone or email to clarify the quote order and confirm the proposed installation and written terms.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Class II biological safety cabinet with clear front sash, stainless-steel work area and support stand

Find equipment.

View cart