Buy Imaging Spare Parts in Nigeria.

Buy medical imaging spare parts in Nigeria through Franance by identifying the exact part and verifying it against the installed equipment. The current imaging-spares parent category groups 12 products into ultrasound probes/transducers, CT tube assemblies, general X-ray tube assemblies and MRI cold heads. A matching brand name or product family is not enough to confirm compatibility.

Browse this range

Products

12 models

Filter all 12 products

Which imaging spare parts are listed by Franance?

The current assignments include four ultrasound transducers: GE HealthCare L4-12t-RS linear probe, GE HealthCare C1-5-RS convex probe, Philips C5-1 PureWave curved-array transducer, and Mindray L12-3E linear transducer.

Read more

How do I confirm an exact replacement part?

Start with the host equipment's manufacturer, model, serial number, system configuration and software or hardware revision. Then provide the full part name, part or material number, serial number of the installed component if visible, service tag, purchase or service history, and a clear label photograph. State the symptom and any diagnostic or service fault code, while excluding patient-identifiable information. Ask the manufacturer or authorized service team to confirm compatibility against the equipment serial number and release level.

Read more

What should I check before buying an ultrasound probe?

Ultrasound probes differ in connector, beamforming interface, element configuration, frequency range, footprint, field of view, application support and system software. The listed GE L4-12t-RS is a linear-array probe; GE identifies selected small-parts, breast, thyroid, musculoskeletal and paediatric applications and compatible LOGIQ/Venue families on its service listing. GE C1-5-RS is a convex-array probe described for abdominal, obstetric and vascular applications. Philips C5-1 is a PureWave curved-array transducer, and Mindray L12-3E is a linear transducer listed in Mindray's DC-70 transducer documentation. Those facts do not imply cross-system compatibility.

Read more

Buy Medical Imaging Spare Parts in Nigeria

Buy medical imaging spare parts in Nigeria through Franance by identifying the exact part and proving that it matches the installed equipment. The current imaging spare parts catalogue groups 12 assigned products into four families: ultrasound probes and transducers, CT X-ray tube assemblies, general X-ray tube assemblies, and MRI cold heads. These are not generic interchangeable parts. A matching brand name or similar model label is not enough to establish fit, software recognition, electrical or thermal compatibility, safe operation, or replacement eligibility. The catalogue records include ultrasound probe/transducer listings, CT tube assemblies, X-ray tube assemblies, and MRI cold heads. Franance takes quote orders rather than online payments. A quote request is not confirmation of stock, price, lead time, compatibility, export/import clearance, or local service. Submit equipment identity and installation information so the part can be reviewed, and require a written offer that states the exact replacement and technical scope.

Which imaging spare parts are listed by Franance?

The current assignments include four ultrasound transducers: GE HealthCare L4-12t-RS linear probe, GE HealthCare C1-5-RS convex probe, Philips C5-1 PureWave curved-array transducer, and Mindray L12-3E linear transducer.

Four CT tube assemblies are assigned: GE MAXIRay CT VCT D3199T, GE MAXIRay CT Ultra D3189T, Siemens Healthineers DURA 422-MV, and GE Performix HD D3703T. Two general X-ray tube assemblies are assigned: Siemens Healthineers DURA 202-MV / 05534750 and GE APOLLON D4193M. Two MRI cold heads complete the current set: SHI RDE-412D4 and GE MRI Shield Cooler 46-294100G1-R.

These listings identify catalogue records only. A part number can be revised, exchanged, refurbished, superseded or restricted to particular equipment generations. Check the written quote against the installed equipment's service records and manufacturer documentation.

How do I confirm an exact replacement part?

Start with the host equipment's manufacturer, model, serial number, system configuration and software or hardware revision. Then provide the full part name, part or material number, serial number of the installed component if visible, service tag, purchase or service history, and a clear label photograph. State the symptom and any diagnostic or service fault code, while excluding patient-identifiable information. Ask the manufacturer or authorized service team to confirm compatibility against the equipment serial number and release level.

Use the part number as a cross-check, not as the only check. A manufacturer may list equivalent or superseding items, but equivalence can depend on system revision, installation instructions, exchange or core-return process, cooling configuration, adapter kit, calibration, software enablement or service bulletin. The offer should identify the supplied item number, whether new, refurbished or exchange, and all required companion parts. Do not fit a part based on a third-party compatibility claim without confirmation from the equipment manufacturer or qualified service provider.

What should I check before buying an ultrasound probe?

Ultrasound probes differ in connector, beamforming interface, element configuration, frequency range, footprint, field of view, application support and system software. The listed GE L4-12t-RS is a linear-array probe; GE identifies selected small-parts, breast, thyroid, musculoskeletal and paediatric applications and compatible LOGIQ/Venue families on its service listing. GE C1-5-RS is a convex-array probe described for abdominal, obstetric and vascular applications. Philips C5-1 is a PureWave curved-array transducer, and Mindray L12-3E is a linear transducer listed in Mindray's DC-70 transducer documentation. Those facts do not imply cross-system compatibility.

Before requesting a probe, share the ultrasound console model, serial number, software version, probe connector and existing probe reference. State the clinical applications and any accessory such as a biopsy guide, but ask the manufacturer to verify both probe and accessory compatibility. If the transducer has been dropped, its cable is damaged, or the lens shows a defect, do not treat it as serviceable based on visual appearance. Ask about electrical integrity testing, leakage testing, image-quality checks and return/warranty handling by qualified service personnel. Confirm whether the quotation includes a carrying case, cable, needle guide or other accessories; do not assume they are included.

How do I select a CT X-ray tube assembly?

CT tube assemblies are engineered components whose compatibility is tied to the exact CT system and generator, not merely to a broad scanner family. Confirm the CT manufacturer, scanner model, serial number, gantry or tube configuration, existing tube material number, software and hardware revision, and service history. Ask the equipment manufacturer or authorized service provider to verify the proposed tube reference and all system-specific prerequisites in writing.

The catalogue includes GE MAXIRay CT VCT D3199T, GE MAXIRay CT Ultra D3189T, Siemens DURA 422-MV and GE Performix HD D3703T. GE Service Shop identifies D3199T and D3189T as direct replacement products for specific Performix references and publishes compatible scanner-family lists. D3703T has its own listed compatibility and replacement references. Siemens publishes DURA 422-MV as a CT tube assembly with associated material numbers and assembly features. Do not transpose one tube's compatible systems or replacement history to another item, even if both are branded for CT.

Request the manufacturer's item number, compatible-system evidence, required system software or service kit, installation procedure, cooling requirements, acceptance checks, warranty conditions, and any exchange/core-return terms. A tube replacement may require specialist installation, calibration, image-quality verification and radiation-safety checks. Define who performs those tasks and who signs off the equipment before it returns to clinical use. A quotation for a tube alone does not imply installation or commissioning is included.

What matters when replacing a general X-ray tube?

For a radiography system tube, identify the X-ray generator and high-voltage configuration, exact tube insert or complete housing assembly, focal spot or anode configuration, mounting and cooling requirements, cable and interface details, material number and system serial number. Clarify whether the requested part is a tube insert, tube assembly, protective housing or complete replacement kit; these terms can refer to different scopes. Siemens DURA 202-MV item 05534750 is described in Siemens' tube catalogue as a replacement tube assembly with housing and integrated components. GE lists APOLLON D4193M item D4193M as an X-ray tube assembly and specifies equivalent references and exchange/core return terms on its service shop page.

Do not assume that a tube with similar kV or anode characteristics can replace an installed unit. The generator, housing, collimator, mounting, cooling circuit, control electronics and system calibration must match the manufacturer's approved configuration. Provide the equipment model and serial number and ask the manufacturer or authorized service provider to verify each part and installation prerequisite. Request the exact assembly drawing or official service part description when the scope is unclear.

How do I assess an MRI cold head or cryocooler part?

An MRI cold head forms part of the magnet's cryogenic cooling system; it is not a general-purpose refrigeration compressor. Establish the MRI magnet model, serial number, cryocooler configuration, cold-head part number, compressor model, helium service history, operating hours, temperature or pressure alarms and service notes. Confirm whether the request is for a cold head alone, a complete assembly, a shield cooler component, compressor, flex lines or a service exchange. Ask the magnet manufacturer or qualified MRI service provider to verify the parts and installation procedure.

The category lists SHI RDE-412D4 and a GE HealthCare MRI Shield Cooler cold head assembly 46-294100G1-R. SHI's specification identifies the RDE-412D4 as a two-stage Gifford-McMahon 4 K cold head and publishes capacities under defined operating conditions and compressor combinations. GE's listed 46-294100G1-R record identifies a refurbished shield cooler assembly. These are technically distinct equipment roles; do not treat a shield cooler cold head as interchangeable with a main magnet cold head. Confirm whether the component reference is approved for the installed magnet and cryocooler package.

MRI cryogenic work requires specialist skills and manufacturer procedures. Do not open or disconnect a cold head, vent or modify helium circuits, or attempt a field installation without trained authorized personnel. In the quote, identify site access, lifting and handling, downtime window, service engineer qualifications, installation, leak checks, cooldown, magnet operating checks, documentation and restoration-to-service responsibility. Clarify what happens if the part is incompatible or fails the post-installation test.

What installation, calibration and safety work should the quote include?

Ask whether the price covers supply only or also export packaging, freight, customs documentation, delivery to the facility, removal of the old part, installation, software configuration, calibration, performance tests, safety checks, clinical acceptance and handover. Identify any required service tool, licensed software, test phantom, cooling components, exchange core or return packaging. State the responsible party for each step and the site-readiness prerequisites.

For X-ray tube replacements, clarify the required installation and acceptance protocol, radiation output and image-quality checks, generator calibration and applicable radiation-safety review. For ultrasound probes, clarify electrical safety, element testing, image evaluation and disinfection compatibility. For MRI cold heads, confirm magnet-specific cryogenic work, leak testing, cooldown and system checks. These are examples of scope to confirm with the equipment manufacturer or qualified service team, not generic instructions to perform the work. Applicable Nigerian regulatory and facility requirements should be verified with the responsible authorities.

What service, warranty and lifecycle terms should I confirm?

Ask who will provide technical support in Nigeria and whether the supplier is the manufacturer, an authorized partner, or another source. Confirm the warranty start date, duration, covered components, exclusions, response process, travel costs, remote support, parts availability, return procedure and the validity of the warranty for the destination. For exchange items, request written instructions and deadlines for returning the defective core, packaging requirements, condition criteria, deposits or core charges and consequences if the core is rejected. GE Service Shop listings show that some items are exchanged and impose model-specific core return terms; do not assume the same terms apply to every tube.

For refurbished items, request the condition definition, refurbishment scope, test record, serial number, remaining service-life limitations if stated by the manufacturer, and the warranty in writing. Keep the installed-part history, service report, calibration and acceptance records with the equipment record. If replacement components have a shelf life or require storage controls, ask for manufacturer-defined packaging and storage limits and confirm transit conditions. A product listing cannot guarantee that parts are in stock or that a service engineer can reach a specific state or city.

What should I send for an imaging spare-parts quote in Nigeria?

Provide the healthcare facility, state and city, equipment manufacturer, exact model and serial number, system software/hardware revision, installed component part number and serial number, symptom or maintenance reason, clear identification photographs, quantity and requested replacement scope. For CT or X-ray tubes, include generator/tube housing information and service history. For a probe, include the console model and connector/probe reference. For an MRI cold head, include magnet and cryocooler identifiers, operating status and service history. Do not send patient-identifiable information.

Request a written proposal that states the exact manufacturer part number, compatibility evidence, revision or supersession status, condition (new/refurbished/exchange), included components, exclusions, core return terms, required installation, calibration and acceptance scope, documentation, freight, lead time, warranty and local service arrangements. Specify any required downtime window and site access arrangements. Do not authorize installation until the manufacturer or qualified technical provider confirms the part and system-specific procedure.

Where can I browse imaging spare parts?

Browse the imaging spare parts parent category and then filter by family: ultrasound probes and transducers, CT X-ray tube assemblies, general X-ray tube assemblies or MRI cold heads. Exact manufacturer part references are linked above. These filters describe catalogue assignment and do not replace system-level compatibility confirmation.

Request an imaging spare-parts quotation in Nigeria

Send the equipment identifiers, installed part reference, intended replacement, fault or maintenance context, destination, condition preference and technical scope. Ask for written confirmation of the exact replacement, compatibility basis, exchange/core rules, installation and acceptance responsibilities, warranty, lead time and local service terms. Request an imaging spare-parts quote from Franance.

Common questions

Can I choose an imaging spare part by model name alone?

No. Confirm the part number against the host equipment manufacturer, exact model, serial number, hardware/software revision and installed configuration. A manufacturer or qualified service provider should verify compatibility.

Are refurbished or exchange tube assemblies the same as new parts?

No. The quotation should state the item condition and any exchange/core-return requirements, deadlines, charges, tests and warranty. These terms are SKU- and region-specific.

Can an ultrasound probe from one brand work on another system?

Do not assume so. Connector, system interface, software and transducer configuration are manufacturer-specific. Verify the exact console model and probe reference before ordering.

Does a spare-part quote include installation?

Not necessarily. Ask the supplier to itemize supply, delivery, removal, installation, calibration, acceptance checks, documentation and service responsibility. Specialized work should be confirmed with the equipment manufacturer or qualified service provider.

Can I buy imaging spare parts online from Franance?

No. Submit a quote order with system identifiers, installed part details and destination in Nigeria. Franance will follow up by phone or email; price, availability, compatibility and service terms require written confirmation.

Request an imaging spare-parts quotation from Franance.

Provide the host system model and serial number, installed part reference, software and hardware revision, service context, facility location in Nigeria and requested installation scope. Ask for written compatibility evidence, part condition, exchange/core terms, testing and acceptance responsibilities, delivery, warranty and local service details. Listing a spare part does not guarantee fit or supply.

Request an imaging spare-parts quote

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart