Compact benchtop PCR thermal cycler with heated lid and front touchscreen

Confirm the exact product reference and supplied package with your quotation.

Bio-Rad

Buy Bio-Rad T100 Thermal Cycler 186-1096
in Nigeria.

96-well PCR thermal cycler

Request a quotation from Franance for the Bio-Rad T100 Thermal Cycler, catalog 186-1096, in Nigeria. State whether you use tubes, strips or 96-well plates, the reaction volume, gradient needs and local power requirements so the package can be checked against your research workflow.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • 96-well 0.2 ml block for tubes, strips or one 96-well plate
  • Temperature range of 4–100°C and thermal gradient capability
  • Research-use-only instrument; confirm exact regional supply configuration
Bio-Rad T100 Thermal Cycler 186-1096 specifications
ManufacturerBio-Rad Laboratories
Model / catalog numberT100 Thermal Cycler; 186-1096
Sample capacity96 × 0.2 ml tubes, tube strips or one 96-well plate
Reaction volume1–100 µl supported; manufacturer recommends 15–100 µl for best reproducibility
Temperature range4–100°C
Maximum ramp rateUp to 4°C/sec
GradientIncluded; gradient range 30–100°C, differential 1–25°C
Temperature accuracy±0.5°C of programmed target
Display5.7-inch VGA colour touchscreen
Input power100–150 VAC or 220–240 VAC, 50–60 Hz; confirm supplied version
Intended useResearch use only

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

What is the T100 designed to do?

It is a conventional PCR thermal cycler rather than a real-time instrument. Bio-Rad highlights a 5.7-inch touch screen, graphical protocol programming, a built-in library of standard protocols and a gradient for optimising assays in a single run. Compare it in the thermal cyclers category or under Bio-Rad.

Read more

Which specifications does Bio-Rad document?

The block takes 96 × 0.2 ml tubes, tube strips or one 96-well plate, with reaction volumes of 1–100 µl. Temperature range is 4–100 °C, maximum ramp rate is 4 °C/sec and temperature accuracy is ±0.5 °C. The gradient covers 30–100 °C with a 1–25 °C differential. It measures 26 × 47 × 23 cm and weighs 9 kg.

Read more

What is included, and what power does it need?

Bio-Rad's ordering table lists 186-1096 as the T100 with a 96-well thermal cycler, power cord and T100 tube support ring. The bulletin gives input power as 100–150 VAC or 220–240 VAC, 50–60 Hz, 670 W maximum. Confirm the supplied voltage version and plug type for your site.

Read more

Buy Bio-Rad T100 Thermal Cycler 186-1096 in Nigeria

The T100 Thermal Cycler, catalog 186-1096, is Bio-Rad's compact 96-well PCR thermal cycler with a touch screen and thermal gradient. This guide summarises the manufacturer's bulletin and what to confirm before requesting a quotation from Franance.

What is the T100 designed to do?

It is a conventional PCR thermal cycler rather than a real-time instrument. Bio-Rad highlights a 5.7-inch touch screen, graphical protocol programming, a built-in library of standard protocols and a gradient for optimising assays in a single run. Compare it in the thermal cyclers category or under Bio-Rad.

Which specifications does Bio-Rad document?

The block takes 96 × 0.2 ml tubes, tube strips or one 96-well plate, with reaction volumes of 1–100 µl. Temperature range is 4–100 °C, maximum ramp rate is 4 °C/sec and temperature accuracy is ±0.5 °C. The gradient covers 30–100 °C with a 1–25 °C differential. It measures 26 × 47 × 23 cm and weighs 9 kg.

What is included, and what power does it need?

Bio-Rad's ordering table lists 186-1096 as the T100 with a 96-well thermal cycler, power cord and T100 tube support ring. The bulletin gives input power as 100–150 VAC or 220–240 VAC, 50–60 Hz, 670 W maximum. Confirm the supplied voltage version and plug type for your site.

What should a Nigerian buyer confirm before ordering?

The bulletin does not state an intended-use classification, and no clinical or diagnostic claim is made here, so confirm suitability for your application independently. Also confirm consumables such as tubes, strips, plates and seals, since the block is a 0.2 ml format.

How can I request a quote in Nigeria?

Add the item to Franance's quote cart at /quote-order.html. State the quantity, Nigeria destination, voltage and plug requirements, and consumables. Franance follows up with a written quotation. This guide does not confirm availability, price, warranty, service or installation.

Manufacturer source: https://www.bio-rad.com/sites/default/files/webroot/web/pdf/lsr/literature/6065.pdf

Supporting Bio-Rad document: https://www.bio-rad.com/sites/default/files/2021-08/10000145577.pdf

Common questions

What is the T100 designed to do?

It is a 96-well PCR thermal cycler (not a real-time instrument) with a 5.7-inch touch screen, graphical programming, a built-in protocol library and a gradient for assay optimisation.

Which specifications does Bio-Rad document?

A 96 × 0.2 ml block, 1–100 µl volumes, 4–100 °C, 4 °C/sec maximum ramp, ±0.5 °C accuracy, a 30–100 °C gradient with 1–25 °C differential, 26 × 47 × 23 cm and 9 kg.

What is included, and what power does it need?

Bio-Rad lists the thermal cycler, power cord and tube support ring. Input is 100–150 VAC or 220–240 VAC, 50–60 Hz, 670 W maximum; confirm the supplied version and plug type.

What should a Nigerian buyer confirm before ordering?

Confirm intended-use suitability, since the bulletin states no classification, and consumables such as tubes, strips, plates and seals for the 0.2 ml format.

How can I request a quote in Nigeria?

Add the item to Franance's quote cart at /quote-order.html with quantity, Nigeria destination, voltage and consumables. Franance follows up with a written quotation; availability and price are not confirmed.

Request your Bio-Rad T100 Thermal Cycler quotation from Franance.

Add Bio-Rad T100 Thermal Cycler 186-1096 (T100; catalog 186-1096) to the Franance quote cart with quantity, destination and required configuration. Franance will confirm the offered specification and terms in writing.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Compact benchtop PCR thermal cycler with heated lid and front touchscreen