Ti-Max Z990L High-Speed Dental Turbine Handpiece
Optic high-speed dental turbine handpiece
Medical equipment and biomedical engineering.
Abuja, Nigeria.
Browse NSK dental equipment listed by Franance, including turbines and dental instruments. Confirm the exact model and coupling compatibility when requesting a quotation.

Optic high-speed dental turbine handpiece
Buy NSK Dental Equipment and Instruments in Nigeria through Franance. The current catalogue lists NSK Ti-Max Z990L High-Speed Dental Turbine Handpiece. For a quotation order, identify the NSK Ti-Max Z990L turbine, dental-unit coupling/interface, required accessories and clinic setup. Include quantities and delivery destination; Franance will follow up by phone or email.

Optic high-speed dental turbine handpiece
Buy NSK Dental Instruments & Tools in Nigeria through Franance. The current catalogue lists NSK Ti-Max Z990L High-Speed Dental Turbine Handpiece. For a quotation order, identify the NSK Ti-Max Z990L turbine, dental-unit coupling/interface, required accessories and clinic setup. Include quantities and delivery destination; Franance will follow up by phone or email.
Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.

Optic high-speed dental turbine handpiece
Buy NSK Dental Handpiece (High-Speed) in Nigeria through Franance. The current catalogue lists NSK Ti-Max Z990L High-Speed Dental Turbine Handpiece. For a quotation order, identify the NSK Ti-Max Z990L turbine, dental-unit coupling/interface, required accessories and clinic setup. Include quantities and delivery destination; Franance will follow up by phone or email.
Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.
Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.
View the NSK high-speed dental handpiece listing, which currently includes the Ti-Max Z990L. Send Franance the required quantity, the exact dental-unit coupling, current hose or connector information, intended clinical use, required accessories and delivery destination. If you are replacing an existing instrument, provide the identification details for the handpiece and coupling, but do not assume a model with a similar name will fit. A photo of the unit's label may help only if shared through an appropriate channel and it contains no patient or confidential data.
Read moreNSK describes the Ti-Max Z990L as an optic high-speed turbine handpiece in its Z990/Z890 series. NSK lists a titanium body with DURAGRIP coating, ceramic bearings, cellular glass optics, Quattro Spray, a DURAPOWER CHUCK and quick-stop features for the Z990L. Its published specifications include 44 W at 0.42 MPa, rotation of 280,000–360,000 per minute and a standard head measuring 12.1 mm in diameter and 12.7 mm high. Verify these values and the model code against the current manufacturer documentation for the exact handpiece being quoted.
Read moreDo not infer coupling compatibility from the Ti-Max Z990 family name alone. NSK's product materials present different variants and coupling options across the Z990/Z890 line. The letter suffix and order code matter. The catalogue entry is Ti-Max Z990L, order code PA23730001, but the facility should still confirm that this exact item mates with its existing NSK coupling or dental unit. If the clinic expects a coupling to be included, specify that requirement and ask the supplier to identify its make, model and code separately.
Read moreFranance lists an NSK Ti-Max Z990L optic high-speed dental turbine handpiece for quotation enquiries in Nigeria. NSK identifies the Z990L with order code PA23730001 and publishes specifications including 44 W power at 0.42 MPa, rotation from 280,000 to 360,000 per minute, a 12.1 mm diameter by 12.7 mm high standard head, Quattro Spray, ceramic bearings, cellular glass optics and a titanium body with DURAGRIP coating. Before requesting a quote, confirm the coupling variant, dental-unit hose, operating pressure, bur requirements, quantity and accessories. The exact configuration governs compatibility. This listing does not confirm Nigerian stock, price, delivery, warranty, local service or authorized dealer status. A product-family page can include multiple coupling and feature variants. Franance handles enquiries as quote orders and follows up by email or phone; submitting a request does not buy the instrument online. Ask for the precise order code and included scope in writing, and have the dental and biomedical engineering teams verify suitability and compatibility before accepting an offer.
View the NSK high-speed dental handpiece listing, which currently includes the Ti-Max Z990L. Send Franance the required quantity, the exact dental-unit coupling, current hose or connector information, intended clinical use, required accessories and delivery destination. If you are replacing an existing instrument, provide the identification details for the handpiece and coupling, but do not assume a model with a similar name will fit. A photo of the unit's label may help only if shared through an appropriate channel and it contains no patient or confidential data.
Franance can review the enquiry and confirm whether it can make an offer for the requested configuration. NSK's product information establishes manufacturer-published characteristics; it does not verify local stock or a Nigerian supply arrangement. Ask for a written quotation naming the Ti-Max Z990L and order code PA23730001, or the exact alternative if you need another coupling. The quote should state price and currency, quantity, freight, delivery terms, warranty, exclusions, included accessories and any service scope. Review compatibility with the dental unit and the current NSK instructions before placing an order.
NSK describes the Ti-Max Z990L as an optic high-speed turbine handpiece in its Z990/Z890 series. NSK lists a titanium body with DURAGRIP coating, ceramic bearings, cellular glass optics, Quattro Spray, a DURAPOWER CHUCK and quick-stop features for the Z990L. Its published specifications include 44 W at 0.42 MPa, rotation of 280,000–360,000 per minute and a standard head measuring 12.1 mm in diameter and 12.7 mm high. Verify these values and the model code against the current manufacturer documentation for the exact handpiece being quoted.
A high-speed handpiece is one part of a dental treatment setup. The compatible coupling, air and water supply, bur type, lighting, infection-control process, maintenance and clinical workflow all matter. Have the dental team specify its intended procedures and the exact instrument properties it needs. Biomedical engineering should confirm the chair unit, hose, coupling, pressure regulation and cleaning/sterilization process. The catalogue entry is not a clinical recommendation and does not establish a full dental-unit package. Ask Franance to state exactly which handpiece, coupling and accessories are included.
Do not infer coupling compatibility from the Ti-Max Z990 family name alone. NSK's product materials present different variants and coupling options across the Z990/Z890 line. The letter suffix and order code matter. The catalogue entry is Ti-Max Z990L, order code PA23730001, but the facility should still confirm that this exact item mates with its existing NSK coupling or dental unit. If the clinic expects a coupling to be included, specify that requirement and ask the supplier to identify its make, model and code separately.
Record the chair unit, hose and current coupling nameplate or part number, and have the dealer or NSK documentation confirm compatibility. Ask the quote to identify whether it is a handpiece-only item or includes a coupling, adapter, tubing or other component. Do not purchase based on visual resemblance, a generic “NSK type” description or a previous unit's compatibility. If the clinic needs a different coupling option, request the exact alternative model and code; the offer may need a separate product listing or supplier confirmation. Before acceptance, dental and engineering teams should agree that the offered configuration is compatible and serviceable within the facility's approved process.
NSK lists 44 W at 0.42 MPa and rotational speed of 280,000 to 360,000 per minute for Ti-Max Z990L. Confirm how the manufacturer defines the pressure measurement and operating conditions in the current technical documents, then compare them with the dental unit's actual specification and the facility's maintenance checks. Do not assume a nominal compressor setting equals the pressure at the handpiece. Ask biomedical engineering to verify air supply, water spray and the relevant connection under the manufacturer's requirements before clinical use.
NSK's product information lists the standard head dimensions as 12.1 mm diameter and 12.7 mm height. Confirm that the head and instrument characteristics fit the intended procedures and operator preference. Verify the required FG bur format, permitted shank dimensions, retention method, speed and operating instructions using current NSK documentation. A bur is not necessarily included in the handpiece price. Ask Franance to show any burs, coupling, maintenance tools or other parts as separately identified quote lines. Check that the package matches the clinic's local instrument reprocessing and maintenance workflows and that staff have access to the manufacturer instructions.
The product listing identifies a handpiece model and selected manufacturer features; it does not define every item in the supply package. Ask the quote to state whether the instrument is supplied alone or with a coupling, adapter, bur, maintenance oil or device, cleaning accessories, light or other component. Confirm the exact order code, lighting specification, spray connection, water and air components and any required service item from NSK's current catalogue. Do not treat a catalogue photograph or family brochure as a package contents list.
List what the clinic already owns and what it requires for a ready-to-use setup. If a coupling is already installed, identify it and ask the supplier to confirm compatibility. If the offer includes optional equipment, request model and part numbers and verify that each is suitable for the intended handpiece. Ask about consumables, replacement parts, maintenance requirements and any recurring costs, but do not assume they are included. A dental practice should also confirm its own approved cleaning, disinfection and sterilization process and ensure that instructions apply to the exact model. Have procurement and clinical teams agree the final package before order acceptance.
Follow current NSK instructions for use and reprocessing for the exact Z990L variant. Dental handpieces are reusable instruments that require handling under the facility's infection-prevention policy. Verify each cleaning, lubrication, disinfection and sterilization step, cycle limits, drying and storage conditions, and any restrictions before use. Do not substitute generic processes or extrapolate from another NSK model. The practice's infection-prevention lead and trained staff should review the manufacturer's instructions and local clinical requirements before adding the instrument to routine use.
Confirm who will perform routine cleaning and maintenance, what products and equipment are approved, what records will be kept and how wear or damage will be identified. Ask the supplier to identify the applicable maintenance kit, replacement components and service procedures, if relevant, and confirm the parts are correct for Z990L. Inspect the handpiece and accessories on receipt; isolate any item with visible damage, abnormal vibration, overheating, leakage or poor operation and follow the manufacturer's troubleshooting guidance. Do not open, alter or repair the device outside an approved service process. Ask Franance to identify any maintenance or support terms specifically included in its quote.
The price requested for a Ti-Max Z990L may depend on the exact order code and configuration, whether a coupling or accessories are included, quantity, delivery destination and any agreed service or training scope. Franance's listing does not publish a Nigerian price. A manufacturer page or overseas price should not be treated as an offer for Nigeria because taxes, freight, currency, availability and commercial terms may differ. Submit the required configuration and request an itemised quote in the currency and validity period relevant to your procurement.
When comparing offers, check that each proposal contains the same Z990L optic version, coupling compatibility, accessories, quantities, delivery and warranty terms. Make sure price, freight, taxes or duties, payment terms and exclusions are visible. Ask whether any replacement parts, maintenance tools or service visits are included and request recurring charges to be disclosed where applicable. Do not assume that warranty or local repair support is available because the brand is established globally. A quote enquiry is not an online purchase and does not reserve stock; approve only after clinical, engineering and procurement review of the written scope.
Provide the practice or hospital address, city, state, receiving contact, access restrictions, quantity and requested timing. Franance can review the destination and confirm any proposed supply and delivery terms in writing. The product listing and NSK's UK product information do not prove Nigerian stock, nationwide coverage, delivery timing, a local NSK representative or service capability. Ask the quotation to specify who supplies the instrument, how delivery is handled, what documentation accompanies it and how the facility should report damage or a discrepancy.
For a multi-branch group, provide each clinic's location and requested quantity separately. Coordinate with the dental-unit technician or biomedical engineering team so the coupling and chair connection can be checked before an instrument is sent to a site. Confirm receiving inspection, asset recording, reprocessing instructions and staff orientation responsibilities. If service or warranty is important, request the exact coverage, provider, location, response terms and exclusions in writing. Do not treat a general claim about Nigeria coverage as proof that every state or city is served under the proposed terms.
Check manufacturer, family, model suffix and order code. Confirm whether the quote specifies Ti-Max Z990L, PA23730001, or names another requested variant. Match the coupling to the practice's chair unit and hose, verify the expected operating pressure, head dimensions, bur type, optics and spray arrangement, and confirm accessories as separate lines. Ask for the current NSK instructions and technical documents for the offered model. The dental team should confirm clinical suitability; biomedical engineering should validate the equipment interface and pressure; infection prevention should approve the reprocessing process.
Review quantity, price and currency, quote validity, freight, taxes or duties, delivery location and timing, warranty, service arrangements, returns, exclusions and payment terms. Confirm that any included coupling, maintenance tool or other accessory has a correct part number. Ask whether replacement parts and repairs are available under the proposed arrangement without assuming that they are. If the quote substitutes a model or leaves coupling unspecified, ask for a revised offer before acceptance. Retain the accepted quotation, product documentation, serial or lot details, maintenance instructions and receiving inspection record with the equipment file.
Open the NSK high-speed dental handpiece listing and request a quote for Ti-Max Z990L. Include the order code PA23730001, quantity, required coupling or existing dental-unit information, intended use, operating pressure requirements, accessory needs and Nigerian destination. If your technical team has a purchase specification, share the non-confidential model and interface requirements. Avoid sharing patient-identifiable information or confidential clinical records through a general commercial enquiry.
Franance can review the request and follow up by email or telephone to clarify the specification and prepare any proposed quotation. Ask for exact model and coupling, included components, unit price, taxes, freight, delivery, warranty and service scope in writing. Compare the offer with current NSK documentation and have dental, engineering, infection-prevention and procurement stakeholders approve the configuration. This is a quote-order process; no online payment is taken and a submitted enquiry does not guarantee stock or supply. Accept only when the model, compatibility, package and commercial terms satisfy the facility's requirements.
NSK identifies Ti-Max Z990L with order code PA23730001. Confirm the code and coupling in the written offer before acceptance.
Compatibility depends on the exact coupling and unit connection. Identify the installed coupling and ask NSK documentation or the supplier to verify the offered model.
The listing is for quote enquiries and does not confirm price or stock. Provide the required configuration and destination and request written terms from Franance.
Provide order code PA23730001, quantity, coupling and dental-unit details, required accessories, operating requirements and destination. Franance can review the quote order and confirm the proposed offer in writing.
Request an NSK quotationAdd the models you need to a quote order, or send us your equipment list.