MydaxMydax

Buy Mydax MRI cooling equipment
in Nigeria.

Explore Mydax outdoor air-cooled chillers listed for MRI cooling applications, including 1M30A-OD and 1M30AS-OD. Franance can prepare a quotation request around your MRI system, heat-rejection requirements, site conditions and selected model; final suitability depends on the project specification.

Buy Mydax MRI Cooling Equipment in Nigeria

View all 2 products

The Mydax catalogue listings under diagnostic imaging are outdoor air-cooled chillers intended for MRI cooling applications. Franance lists models 1M30A-OD and 1M30AS-OD. Share the MRI system details and project cooling specification when requesting a quotation so the required configuration can be reviewed.

Buy Mydax MRI System Chillers in Nigeria

View all 2 products

Mydax models 1M30A-OD and 1M30AS-OD are listed by Franance as outdoor air-cooled chiller options for MRI cooling. When comparing them, use the MRI equipment specification and project requirements rather than model naming alone; request a quotation with the relevant technical details.

Provide the MRI system make and model, manufacturer cooling requirements, target operating conditions, site climate and installation constraints, preferred Mydax reference and delivery location. Have the final selection checked against the equipment documentation.

Buy Mydax MRI Chiller Units in Nigeria

View all 2 products

Franance lists two Mydax MRI chiller units: the 1M30A-OD outdoor air-cooled MRI chiller and the 1M30AS-OD outdoor air-cooled chiller for MRI cooling. Submit your MRI model and cooling-duty information with the requested reference to obtain a project-specific quotation.

Specify 1M30A-OD or 1M30AS-OD, the MRI system’s required heat rejection and flow conditions, electrical supply, outdoor installation limits, quantities and project site. Ask for written confirmation of compatibility and the quoted technical scope.

Include the exact Mydax model, MRI manufacturer and system configuration, required cooling duty and operating conditions, site location, quantity and project timeline. Request confirmation that the proposed model matches the system and site design.

Where can I buy a Mydax MRI chiller in Nigeria?

Review Franance's Mydax 1M30A-OD filtered MRI chiller listing or the 1M30AS-OD filtered listing. Both routes constrain results by manufacturer, MRI-chiller category and model. Send Franance the MRI scanner make, exact model, OEM chiller specification, required cooling capacity, fluid, flow, pressure, temperature range, ambient conditions, electrical supply, quantity and facility address.

Read more

What is a Mydax 1M30A-OD MRI chiller?

Mydax's current medical page presents the 1M30A-OD as an outdoor air-cooled chiller for MRI cooling. It describes 30,000 Btu/hr cooling and stable operation at a stated 4 GPM and 40 PSI with a 50/50 water-glycol mix. The official Mydax Medical page positions the system as precision cooling for medical and imaging applications. These figures are product information, not proof that a scanner's required load, coolant or setpoints match the chiller.

Read more

What is the difference between 1M30A-OD and 1M30AS-OD?

The manufacturer's product sheet groups both model names under an outdoor-rated air-cooled chiller family. It describes a pump difference: 1M30A-OD uses a vertically mounted leak-free seal-less stainless-steel centrifugal pump, while 1M30AS-OD uses a horizontally mounted stainless-steel centrifugal pump with a mechanical seal. Confirm that this distinction remains current and that it accurately describes the specific unit offered; the document's revision date is 2001.

Read more

Buy Mydax MRI chillers in Nigeria

Franance lists two Mydax outdoor air-cooled MRI chillers in the MRI chiller category: 1M30A-OD and 1M30AS-OD. Browse the Mydax 1M30A-OD filtered listing and Mydax 1M30AS-OD filtered listing to inspect the two catalogue entries. Both are presented by Mydax for medical and MRI cooling, but a listed chiller is not proof of compatibility with a particular scanner or site. The Mydax medical page describes 1M30A-OD at 30,000 Btu/hr with a 50/50 water-glycol mixture and flow of 4 GPM at 40 PSI. The downloadable product sheet includes both 1M30A-OD and 1M30AS-OD and describes differing pump constructions. That sheet is dated 2001, so request a current revision and written manufacturer confirmation before relying on its electrical, hydraulic, dimensions, refrigerant, warranty or installation values. Scanner requirements and site conditions must be checked against the MRI manufacturer's approved cooling specification. No Nigerian stock, approved scanner pairing, local distributor status, price, warranty, delivery, installation, commissioning, service or registration is promised. MRI cooling is a critical system; facility engineering, biomedical engineering, MRI vendor and chiller supplier must validate the complete design. Franance uses a quotation order process: submit scanner and site requirements, and Franance will follow up by phone or email. Confirm the exact model and all local terms in writing before order.

Where can I buy a Mydax MRI chiller in Nigeria?

Review Franance's Mydax 1M30A-OD filtered MRI chiller listing or the 1M30AS-OD filtered listing. Both routes constrain results by manufacturer, MRI-chiller category and model. Send Franance the MRI scanner make, exact model, OEM chiller specification, required cooling capacity, fluid, flow, pressure, temperature range, ambient conditions, electrical supply, quantity and facility address.

Franance handles requests by quotation rather than online checkout. After receiving your details, Franance will follow up by phone or email to clarify the application and discuss a quotation order. The catalogue does not show live inventory or confirm an approved installation for your scanner. Ask the written proposal to confirm the exact chiller part number, current manufacturer documentation, scanner compatibility, supply and delivery terms, price validity, warranty, commissioning and service scope.

For a new MRI project, involve the scanner supplier and facilities engineer early. For a replacement, identify the existing chiller, its serial number, cooling loop, coolant, alarms and connection points. Share only site details that your facility permits. A chiller should not be selected by capacity or brand alone; the complete operating envelope and scanner-specific requirements must match.

What is a Mydax 1M30A-OD MRI chiller?

Mydax's current medical page presents the 1M30A-OD as an outdoor air-cooled chiller for MRI cooling. It describes 30,000 Btu/hr cooling and stable operation at a stated 4 GPM and 40 PSI with a 50/50 water-glycol mix. The official Mydax Medical page positions the system as precision cooling for medical and imaging applications. These figures are product information, not proof that a scanner's required load, coolant or setpoints match the chiller.

The manufacturer's product sheet lists both 1M30A-OD and 1M30AS-OD in the same outdoor-rated air-cooled family. It provides detailed specifications including cooling capacity under specified rating conditions, adjustable fluid temperature range, temperature stability, pump, reservoir, electrical service, ambient limits, physical parameters and safety interlocks. However, the sheet is dated 30 March 2001. Use it as historical manufacturer documentation to frame questions, not as a current engineering submittal. Request the latest specification and confirm any changes directly for the unit being quoted.

Mydax describes a proportional refrigeration design and integrated pump and reservoir in its product materials. Its current website speaks generally about the 1M30A-OD. Do not extrapolate every technical feature or every promotional performance claim to a particular scanner installation. Require written confirmation of the current configuration, control interfaces, alarms and operating conditions.

What is the difference between 1M30A-OD and 1M30AS-OD?

The manufacturer's product sheet groups both model names under an outdoor-rated air-cooled chiller family. It describes a pump difference: 1M30A-OD uses a vertically mounted leak-free seal-less stainless-steel centrifugal pump, while 1M30AS-OD uses a horizontally mounted stainless-steel centrifugal pump with a mechanical seal. Confirm that this distinction remains current and that it accurately describes the specific unit offered; the document's revision date is 2001.

The two listings should not be treated as identical simply because the product sheet presents shared nominal performance figures. Ask Mydax to state the exact model, pump assembly, service requirements, fluid fittings, flow and pressure curve, maintenance procedure and any relevant scanner-approved configuration. A different pump architecture may affect replacement parts or maintenance planning, even if a published sheet lists common cooling capacity.

Use the 1M30A-OD listing and 1M30AS-OD listing when building separate quote lines. If you are replacing an existing Mydax unit, match the exact model and serial rather than assuming a newer or similar model is a drop-in replacement. Obtain approval from the MRI original equipment manufacturer and facility engineering before substitution.

How do I confirm compatibility with my MRI scanner?

Obtain the scanner manufacturer's approved chiller specification for the exact magnet and system configuration. It should define heat load, required fluid type and concentration, minimum and maximum supply temperature, temperature stability, flow, pressure, connection sizes, alarms, electrical service, communication or interlock needs and environmental limits. Send that document to the chiller supplier and request a model-specific written compatibility assessment. A general “MRI chiller” label or a published cooling capacity is not enough.

Check whether the scanner requires a specific chiller model, an OEM-approved equivalent or an external cooling loop design. Confirm who accepts responsibility for validating the chiller-scanner pairing and whether using an alternative affects scanner warranty, installation acceptance, service or performance. No Mydax scanner approval or specific MRI pairing is established by the Franance listing.

Ask for interface drawings and a responsibility matrix. Identify who supplies hoses, fittings, valves, filters, expansion tank or reservoir, coolant, sensors, control cable, remote alarms and connection labor. Confirm pressure-drop assumptions for the installed pipe run and the chiller's actual performance at the site's ambient temperature and elevation. Have the MRI vendor and qualified mechanical engineer approve the final design before purchase.

What cooling capacity and fluid requirements should I check?

Mydax's current medical page describes the 1M30A-OD at 30,000 Btu/hr and states 4 GPM at 40 PSI using a 50/50 water-glycol mixture. The manufacturer's product sheet gives a net cooling capacity of 8,798 watts or 30,000 Btu/hr under stated rating conditions, including a fluid outlet of +16°C and ambient air at +49°C. It lists a fluid adjustment range of +4.5°C to +21°C and temperature stability of ±0.5°C. Request current values and test conditions for the exact model, since the reviewed technical sheet is dated 2001.

Verify the scanner's required coolant type and exact glycol chemistry and concentration. Do not substitute ethylene glycol, propylene glycol, water quality or additive package based on a generic “50/50” description. Ask the MRI OEM to define acceptable fluid and flushing, fill, sampling and replacement procedures. Confirm whether the quote includes coolant, fill material, hoses, fittings, strainers, filters or water-treatment accessories.

Confirm flow and pressure at the scanner inlet after accounting for pipe length, elevation and fittings, not only at the chiller outlet. Request a current pump curve and minimum flow protection information. Establish alarm thresholds for low flow, high temperature, reservoir level and pressure faults. A mismatch can risk scanner trips or downtime; design and acceptance should be managed by qualified engineering and the MRI vendor.

What electrical and environmental conditions must be confirmed?

The manufacturer's older data sheet lists 208/240 VAC, 60 Hz, three-phase electrical service at 30 amperes. This information is particularly important for a Nigerian installation, where site supply may be based on a different frequency, voltage or phase arrangement. Do not assume that the listed chiller will operate directly from a facility's supply or that a transformer or frequency converter is an approved solution. Ask Mydax for the current regional electrical option and obtain written approval from the MRI OEM and a qualified electrical engineer.

The old sheet lists an ambient use range of approximately -28°C to +49°C, condenser airflow of 5,000 CFM directed upward, and an outdoor-rated enclosure with a NEMA 4 control panel. Confirm current ratings, airflow clearance, weather exposure, service access, noise and heat rejection. The chiller needs an outdoor location capable of rejecting heat and maintaining airflow; a rooftop or enclosure installation may need structural review and weather protection.

The data sheet also lists dimensions of about 63 inches high by 45 inches wide by 48 inches deep and dry weight of about 850 lb. These values need confirmation from a current drawing and packaging schedule. Check slab or roof load, lifting points, crane or forklift access, route clearance, vibration control and service side clearance. Do not plan transport based solely on an old brochure.

What installation and connection details belong in a quote?

Request a mechanical schedule and interface drawing showing the chiller connections, supply and return, pipe size, flow direction, valves, isolation, expansion or reservoir arrangement, sensors and any control or alarm wiring. Confirm whether the unit includes pump, reservoir, controls and safety interlocks in the quoted configuration. The historical sheet describes a stainless-steel reservoir and safety interlocks such as reservoir-empty, refrigerant pressure, fluid flow and over-temperature switches, but those items must be confirmed for the exact current model.

Clarify which party is responsible for civil works, electrical feeders, isolators, protection, cabling, piping, supports, coolant, insulation, flushing, leak tests, commissioning and coordination with the scanner vendor. State whether installation, start-up and performance testing are included or separately quoted. Ask for the commissioning acceptance criteria and records, including flow, pressure, setpoint stability, alarm test and scanner interface test as applicable.

If an existing chiller is being replaced, document the current pipe size, coolant, pressure, pump arrangement, electrical service and alarm connection before removing it. Confirm whether existing hoses and fittings can be reused; do not assume connection compatibility. Obtain written approval for any change in equipment or control interface from the MRI OEM.

What maintenance, warranty and service should I confirm?

Ask for the current operation and maintenance manual, service intervals, filter or strainer replacement schedule, refrigerant service details, pump maintenance instructions, coolant monitoring requirements and alarm troubleshooting procedure. Establish who will perform checks, what remote monitoring is available and which spare parts are needed. The manual should identify safe isolation steps and the qualifications needed for electrical and refrigeration work.

The older 2001 manufacturer data sheet advertises an OEM warranty of 14 months for parts and labor at the installation site. That dated statement does not prove that a current unit, a Nigerian installation or this transaction receives the same coverage. Request the current written warranty, start date, geographic coverage, response process, travel and freight responsibility, labor terms, exclusions and required commissioning conditions from the supplier.

No local Nigerian service coverage, installation team or parts inventory is established by the Franance listing. Ask who can service the chiller at your location, how faults are escalated, whether remote diagnostics are supported, which parts are stocked and whether a loan unit exists. If uptime or local response is mandatory, require the support commitment in the quotation before approval.

What does a Mydax MRI chiller cost in Nigeria?

Franance does not publish a fixed online price for the 1M30A-OD or 1M30AS-OD. Request a quote for the exact model, scanner application, electrical version, accessories, quantity and destination. Ask the supplier to itemize the chiller, pump configuration, reservoir, controls, coolant, hoses and fittings, electrical components, installation, commissioning, freight, insurance and any optional support contract.

The proposal should state currency, validity period, payment terms, taxes, import charges, delivery estimate and exclusions. Do not treat a U.S. manufacturer price or an old budget quote as the delivered Nigerian cost. For a hospital project, include the scanner specification and delivery site in your enquiry so the supplier can confirm engineering assumptions before commercial pricing is finalized.

Franance will follow up by phone or email to clarify requirements and discuss a quotation order. That does not guarantee inventory, the specific electrical version, scanner approval or a lead time. Review all technical and commercial conditions together and obtain engineering acceptance before order.

Can Franance deliver Mydax chillers across Nigeria?

The catalogue makes no blanket promise of Nigerian stock or nationwide delivery. Send Franance the full site address, city and state, receiving hours, lifting access, installation location, electrical readiness, delivery timeline and site contact. Ask for written confirmation that the exact configuration can be supplied there, expected lead time, freight, insurance, customs or other charges, unloading, lifting and any installation exclusions.

An outdoor chiller may be a large and heavy shipment. Confirm packed dimensions, shipping weight, lifting instructions, route, crane or forklift requirements, weather protection during transport and temporary storage conditions. For a rooftop installation, plan access and structural approval before dispatch. Do not assume that delivery to the hospital entrance includes lifting, positioning, pipework or commissioning.

For a multi-site program, provide a separate model and schedule for each scanner and site. Coordinate arrival with the MRI vendor, civil works and electrical installation. Record serial number, condition and accessories when received, and ensure installation acceptance is planned before the scanner commissioning window.

How do I request a Mydax MRI chiller quote from Franance?

Open the Mydax 1M30A-OD filtered listing or the 1M30AS-OD listing. Send the MRI OEM chiller specification, scanner model and configuration, requested chiller model, fluid, cooling load, flow and pressure, electrical supply, ambient conditions, pipe and connection details, quantity, site location and required commissioning date.

Franance will follow up by phone or email to clarify requirements and discuss a quotation order. Ask the quote to identify the current chiller revision, exact electrical option, pump, rated performance conditions, accessories, installation and commissioning responsibilities, delivery terms, warranty and local service arrangements. Have the MRI OEM, facilities engineer and biomedical engineering team approve the complete design before accepting an equivalent model.

Do not approve a chiller based only on nominal capacity or a general MRI label. Confirm the scanner-specific heat rejection, electrical service, glycol loop, alarms and support plan in writing. That review prevents an online catalogue description from being mistaken for a verified system pairing.

Common questions

Which Mydax MRI chillers are in the Franance catalogue?

The current catalogue lists the Mydax 1M30A-OD and 1M30AS-OD. The brand-filtered MRI chiller listing groups the current models.

Will either model automatically fit my MRI scanner?

No compatibility should be assumed. Send the scanner make, exact model, chiller interface requirements and service documentation so the proposed configuration can be checked by qualified technical teams.

Can I connect the published Mydax electrical configuration in Nigeria?

Do not assume so. The legacy manufacturer sheet specifies a 60 Hz three-phase electrical configuration; confirm the actual current model nameplate and an engineered electrical solution against the site supply before ordering.

Does Franance guarantee local chiller stock or service?

No stock or local-service commitment is implied by the manufacturer literature. Franance can review the specific request and confirm any supply, delivery, installation or service terms in writing.