Luxfer L7X P7040S 3 L Type 2 Medical Oxygen Cylinder
Type 2 hoop-wrapped medical oxygen cylinder
Medical equipment and biomedical engineering.
Abuja, Nigeria.

Browse medical oxygen cylinder models from Luxfer listed by Franance. Confirm the applicable cylinder standard, valve interface, service pressure, filling system and destination before requesting a quotation.

Type 2 hoop-wrapped medical oxygen cylinder

Type 2 hoop-wrapped medical oxygen cylinder
Buy Luxfer Gas Cylinders Respiratory & oxygen therapy in Nigeria through Franance. The current catalogue lists Luxfer L7X P7040S 3 L Type 2 Medical Oxygen Cylinder; Luxfer L7X P7050S 2 L Type 2 Medical Oxygen Cylinder. For a quotation order, specify the 2 L P7050S or 3 L P7040S cylinder, quantity, intended supply setup and compatible valve or regulator requirements. Include quantities and delivery destination; Franance will follow up by phone or email.

Type 2 hoop-wrapped medical oxygen cylinder

Type 2 hoop-wrapped medical oxygen cylinder
Buy Luxfer Gas Cylinders Oxygen Supply Devices in Nigeria through Franance. The current catalogue lists Luxfer L7X P7040S 3 L Type 2 Medical Oxygen Cylinder; Luxfer L7X P7050S 2 L Type 2 Medical Oxygen Cylinder. For a quotation order, specify the 2 L P7050S or 3 L P7040S cylinder, quantity, intended supply setup and compatible valve or regulator requirements. Include quantities and delivery destination; Franance will follow up by phone or email.
Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.

Type 2 hoop-wrapped medical oxygen cylinder

Type 2 hoop-wrapped medical oxygen cylinder
Buy Luxfer Gas Cylinders Oxygen Cylinder in Nigeria through Franance. The current catalogue lists Luxfer L7X P7040S 3 L Type 2 Medical Oxygen Cylinder; Luxfer L7X P7050S 2 L Type 2 Medical Oxygen Cylinder. For a quotation order, specify the 2 L P7050S or 3 L P7040S cylinder, quantity, intended supply setup and compatible valve or regulator requirements. Include quantities and delivery destination; Franance will follow up by phone or email.
Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.
Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.
Franance lists two Luxfer cylinders in the brand-filtered oxygen cylinder category: L7X P7040S and L7X P7050S. Both are quote-order catalogue entries rather than an online checkout. Send the exact part number, quantity, facility city and state, complete delivery destination, intended filling arrangement and required documents. Franance follows up by phone or email to clarify the request and confirm the terms available for that order.
Read moreLuxfer describes the L7X medical series as Type 2 hoop-wrapped cylinders with an aluminium liner and carbon-fibre wrap around the body. It says the construction has a flat base so the cylinder can stand without additional support. The Franance catalogue lists the P7040S as a 3 L model and P7050S as a 2 L model. Luxfer's official tables provide additional size and capacity values, but the pressure conflict for P7050S must be resolved before the system is specified.
Read moreLuxfer's current product page lists P7040S with 3 L water volume, 200 bar service pressure, 111 mm diameter, 425 mm length, 2.1 kg weight, 639.7 L oxygen capacity and 25E thread size. The same page lists P7050S with 2 L water volume, 300 bar service pressure, 97 mm diameter, 390 mm length, 1.9 kg weight, 611.8 L capacity and 25E thread. Those are the live product page values at the time of this research.
Read moreFranance lists two Luxfer L7X Type 2 medical oxygen cylinders: P7040S, the 3 L model and P7050S, the 2 L model. Request a quote order with the exact part number, required quantity, cylinder markings, valve and regulator interface, filling system, facility destination and documentation requirements. Franance follows up by phone or email; the catalogue does not establish stock, price, Nigerian registration or delivery terms. There is a material source discrepancy to resolve before specifying P7050S: Luxfer's current product page lists 300 bar for that part number, while Luxfer's 2026 brochure table lists 200 bar. Because service pressure affects cylinder selection and safe filling, do not rely on either value for the purchase until the manufacturer or supplier confirms the exact part number, markings, standard and permitted service pressure in writing. The guides and current listings are not a substitute for the cylinder label, approved filling procedure or applicable local requirements.
Franance lists two Luxfer cylinders in the brand-filtered oxygen cylinder category: L7X P7040S and L7X P7050S. Both are quote-order catalogue entries rather than an online checkout. Send the exact part number, quantity, facility city and state, complete delivery destination, intended filling arrangement and required documents. Franance follows up by phone or email to clarify the request and confirm the terms available for that order.
Ask the written quotation to state the exact cylinder part number and markings, construction, water volume, verified service pressure, valve and thread, included accessories, applicable standard, price and validity, payment terms, freight, delivery responsibilities, regulatory documents and any exclusions. Confirm whether a valve, regulator or filling equipment is included or needs to be purchased separately. The listing alone does not establish local availability or cylinder compatibility.
Luxfer describes the L7X medical series as Type 2 hoop-wrapped cylinders with an aluminium liner and carbon-fibre wrap around the body. It says the construction has a flat base so the cylinder can stand without additional support. The Franance catalogue lists the P7040S as a 3 L model and P7050S as a 2 L model. Luxfer's official tables provide additional size and capacity values, but the pressure conflict for P7050S must be resolved before the system is specified.
The part numbers are distinct; do not treat “L7X” alone as enough to identify the requested cylinder. Match the part number and marking to the quotation, delivery label and manufacturer documents. Confirm cylinder material, water volume, dimensions, weight, oxygen capacity, service pressure, valve interface and relevant standard for the exact model and intended market. The manufacturer's page includes a product table for EU configurations, which does not by itself establish conformity or suitability in Nigeria.
Luxfer's current product page lists P7040S with 3 L water volume, 200 bar service pressure, 111 mm diameter, 425 mm length, 2.1 kg weight, 639.7 L oxygen capacity and 25E thread size. The same page lists P7050S with 2 L water volume, 300 bar service pressure, 97 mm diameter, 390 mm length, 1.9 kg weight, 611.8 L capacity and 25E thread. Those are the live product page values at the time of this research.
Luxfer's 2026 brochure table lists the same P7050S part number at 200 bar, not 300 bar. It also lists different standards notation than the live product page. The difference is not safe to reconcile by inference. Ask Luxfer or the supplying party to confirm the P7050S marking and correct technical documentation for the exact market and configuration. Until written confirmation is received, treat P7050S pressure and standard as unresolved. P7040S is listed at 200 bar in both tables, but still verify the delivered cylinder markings and current documentation.
Water volume and oxygen capacity describe aspects of the cylinder specification, but they do not determine how long a cylinder will last in a particular clinical use. Duration depends on the applicable filled pressure, usable gas, regulator and flow settings, equipment demands, residual-pressure policy and actual clinical workflow. The facility's oxygen-system and clinical teams should calculate requirements using the verified cylinder documentation and intended use.
Before ordering, state whether the cylinders are for a portable emergency set, transport, homecare, a manifold or another defined oxygen supply arrangement. Specify the expected quantity, filled or empty status, storage and transport plan, refill frequency and compatible filling provider. Ask the supplier to confirm whether cylinders are supplied empty or filled and what packaging or hazardous-goods arrangements apply. Do not use the manufacturer's nominal oxygen-capacity figure as a substitute for local supply planning.
Luxfer's product table lists a 25E thread size for both L7X part numbers, but the exact valve fitted to an offered cylinder and its compatibility with your regulator or filling connector still require confirmation. Give the supplier the regulator and filling-system manufacturer, model, connection standard and operating-pressure rating. Request a written compatibility check for the exact cylinder part number, valve assembly and destination.
Do not force, adapt or interchange gas connections based on appearance. A cylinder must only be filled by a provider using an approved process for the exact cylinder and gas. Confirm that the valve, regulator, filling connection and permitted working pressure match the marked cylinder. If a different connection is needed, request an approved and documented configuration; do not rely on an improvised adapter or an undocumented valve change.
Luxfer describes Type 2 as an aluminium cylinder liner with carbon fibre wrapped around the cylinder body. It says the L7X medical cylinders use an aluminium liner made from its L7X alloy and a flat base that allows freestanding placement. This describes the manufacturer's product family, not a substitute for inspecting the specific cylinder, markings, valve, protective features and current condition.
Ask the supplier to confirm the exact construction and serial or batch identification, and provide the applicable current inspection, use, transport and maintenance instructions. Confirm any restrictions on impact, heat, handling, cleaning, storage, periodic inspection and service life from the manufacturer documentation and the responsible gas supplier. A high-pressure cylinder is a regulated pressure receptacle; follow the marking, manual and local requirements rather than relying on product photography or a short catalogue description.
Luxfer's product page identifies the EU table for medical L7X cylinders and lists TPED for both model rows. Its 2026 company brochure lists EN 12257 / ISO 11119-1 in a separate table. The standard references should be checked against the current documentation for the exact part number, market, manufacturing batch and cylinder marking. This guide does not determine which standard or certificate satisfies Nigerian regulatory requirements.
Request current manufacturer datasheets, applicable conformity certificates, cylinder markings and the instructions for safe use, filling, inspection and transport. Ask your facility's procurement, medical-gas, safety and regulatory professionals to verify whether the documents apply to the exact offered cylinder and meet the requirements for the intended Nigerian use. Confirm whether import, registration, pressure-vessel inspection or other approvals are needed with the responsible authorities and qualified local professionals.
Do not treat an EU table or a general company brochure as proof of local acceptance, registration, filled-gas quality or compatibility with a Nigerian filling station. Obtain the documents and written supplier confirmations before purchase and before putting cylinders into service.
Cylinder handling and use must follow the cylinder marking, current Luxfer instructions, gas supplier procedures and applicable Nigerian rules. Keep oxygen cylinders secured, protected from impact and heat, separated and handled according to the facility's medical-gas safety plan. Oxygen is an oxidizing gas; keep oil, grease and incompatible materials away from oxygen equipment and connections. Only trained personnel should connect, inspect or operate cylinder valves and regulators.
Confirm whether the order is for cylinders only or includes regulators, trolleys, carrying equipment, protective caps or filling. Establish who supplies the oxygen, which filling point will refill the specific part number, what inspection or exchange process applies, and how full and empty cylinders are identified. The product listing does not imply a gas fill, regulator, trolley, delivery of medical oxygen, or local cylinder-exchange service.
For mobile or emergency use, the facility's responsible clinicians and medical-gas professionals should verify the approved setup and calculate the required supply using the confirmed operating pressure and flow. This buying guide is not operational training or clinical instruction.
Before purchase, request a written response that identifies P7050S, the exact cylinder revision or marking, applicable standard and rated service pressure. Point out that the current Luxfer product page displays 300 bar for P7050S, while Luxfer's 2026 cylinder brochure shows 200 bar in its P7050S row. Ask which table applies to the specific part number and market, and request an updated datasheet or formal manufacturer clarification.
Until that mismatch is resolved, do not select a regulator, filling station, pressure setting or transport arrangement based on an assumed value. Have the facility's medical-gas lead and the filling provider review the exact documentation and physical markings. If the offered cylinder does not match the approved specification, do not accept it as interchangeable. This is a technical procurement discrepancy, not an invitation to choose the higher or lower value.
Use the Luxfer-filtered oxygen cylinder category to compare the P7040S listing and P7050S listing, then send Franance a Luxfer medical cylinder quote enquiry. Include the exact part number, quantity, required pressure as verified for the offered cylinder, valve and regulator connection, filling provider, documents, facility city and state, and complete delivery address. Franance follows up by phone or email; online payment is not offered.
Ask for a written quotation that states the exact model and marking, current technical datasheet, verified service pressure, applicable standard, valve, accessories, whether cylinders are full or empty, price and validity, payment terms, transport, import and delivery scope, and exclusions. Confirm that your filling provider accepts the specified cylinder and that your facility's safety and regulatory reviewers approve the documents. Availability, local conformity, filling and delivery terms must be confirmed for the actual order.
Provide the model number P7040S or P7050S, quantity, use case, expected gas demand, storage and transport arrangements, filling-station details, regulator and connection model, cylinder status requested, destination and required documents. Ask for the exact cylinder marking and current datasheet. For P7050S, explicitly request resolution of the 200 bar versus 300 bar conflict before proceeding. For P7040S, verify the stated 200 bar rating and current standard against the delivered markings as well.
Ask Franance to list any unconfirmed items on the quotation so that you can route them to the medical-gas, safety, procurement and regulatory reviewers. Confirm who will supply the oxygen fill, whether a valve or regulator is included, how the cylinders will be transported, and which party handles local conformity or import documents. Do not assume those items from the product description.
Franance can follow up by phone or email to clarify the quote order. The final purchase and use decision should rely on the written supplier response, current manufacturer documents, exact cylinder markings, filling-system compatibility and applicable Nigerian requirements.
Franance lists L7X P7040S and P7050S in its Luxfer-filtered oxygen cylinder category. Submit a quote order with the exact part number, quantity, valve and filling needs, documents and destination. Franance follows up by phone or email; availability and terms are confirmed in writing.
Luxfer lists P7040S as a 3 L model and P7050S as a 2 L model. The official sources disagree on P7050S service pressure, so confirm the exact cylinder marking and rating in writing before specifying or filling it.
Luxfer's current product page lists 300 bar, while its 2026 brochure lists 200 bar. The discrepancy is unresolved; obtain manufacturer clarification for the exact part number and market before ordering, filling or use.
The listing does not establish that a regulator, valve assembly, filling service or oxygen gas is included. Ask for an itemized written quotation and verify the filling provider's compatibility with the exact marked cylinder.
Identify P7040S or P7050S, quantity, verified rating and standard, valve and filling compatibility, documentation and full Nigerian destination. Franance will follow up to clarify the quote order and terms.
Request a Luxfer quoteAdd the models you need to a quote order, or send us your equipment list.