ICU Medical

Buy ICU Medical infusion pumps and systems
in Nigeria.

Browse ICU Medical CADD infusion systems listed by Franance. Specify the CADD-Solis VIP pump model, delivery modes, compatible consumables and clinical configuration for a quotation.

Buy ICU Medical Anaesthesia & surgical equipment in Nigeria

View all 3 products

Buy ICU Medical Anaesthesia & surgical equipment in Nigeria through Franance. The current catalogue lists ICU Medical CADD-Solis VIP 2120 Ambulatory PCA Infusion Pump. For a quotation order, specify the CADD-Solis VIP 2120 PCA pump, intended infusion workflow, required accessories or consumables, quantities and destination. Include quantities and delivery destination; Franance will follow up by phone or email.

Buy ICU Medical Infusion & Fluid Delivery in Nigeria

View all 3 products

Buy ICU Medical Infusion & Fluid Delivery in Nigeria through Franance. The current catalogue lists ICU Medical CADD-Solis VIP 2120 Ambulatory PCA Infusion Pump. For a quotation order, specify the CADD-Solis VIP 2120 PCA pump, intended infusion workflow, required accessories or consumables, quantities and destination. Include quantities and delivery destination; Franance will follow up by phone or email.

Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.

Buy ICU Medical Syringe Pumps in Nigeria

View 1 product

ICU Medical lists Medfusion 4000 as a syringe infusion pump. Review the product record and manufacturer information, then specify the clinical workflow, required accessories and quantity to be quoted.

Include the Medfusion 4000 reference, intended use area, requested accessories and connections, quantity and destination. Ask Franance to confirm the offered configuration and included components in writing.

Buy ICU Medical Volumetric Infusion Pumps in Nigeria

View 1 product

ICU Medical lists Plum 360 as a large-volume infusion pump. Review its product record and manufacturer information, then define the care workflow and requested configuration for a quotation.

Identify Plum 360, the intended use area, accessories and connection requirements, quantity and destination. Ask Franance to confirm the proposed model configuration and included items in the quotation.

Buy ICU Medical PCA Pumps in Nigeria

View 1 product

Buy ICU Medical PCA Pumps in Nigeria through Franance. The current catalogue lists ICU Medical CADD-Solis VIP 2120 Ambulatory PCA Infusion Pump. For a quotation order, specify the CADD-Solis VIP 2120 PCA pump, intended infusion workflow, required accessories or consumables, quantities and destination. Include quantities and delivery destination; Franance will follow up by phone or email.

Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.

Send exact model references, quantities by location and the intended facility requirements. Ask Franance to confirm the offered configuration, accessories, delivery and any separately requested technical services in the written quotation.

Where can I buy an ICU Medical CADD-Solis VIP in Nigeria?

Open the CADD-Solis VIP category listing, which currently includes the VIP 2120 ambulatory PCA pump. Send Franance the model reference, intended mode, language code, accessories and consumables required, quantity, clinical setting and destination. If replacing or standardising existing pumps, include the current CADD model and compatible consumables, after confirming that information with biomedical engineering and pharmacy. For a tender, provide the non-confidential technical schedule and define the included disposables separately from durable equipment.

Read more

What is the CADD-Solis VIP 2120 ambulatory pump?

ICU Medical describes CADD-Solis VIP as an ambulatory infusion system in the CADD family. The manufacturer's catalogue lists reference 21-2120-0105-XX as a CADD-Solis VIP 2120 ambulatory infusion pump with PharmGuard enabled, and reference 21-2127-0105-XX as a manual-mode pump with standard settings. The “XX” in the catalogue reference is replaced by a language code. These configurations should not be treated as interchangeable: confirm which version matches the facility's medication-safety governance, software and programming workflow.

Read more

Should I request PharmGuard or manual mode?

The official ICU Medical catalogue distinguishes a CADD-Solis VIP 2120 PharmGuard-enabled version, identified with a blue label, from a manual-mode version with standard settings, identified with a black label. The references use language suffixes: the manufacturer says to replace “XX” with the required language code. Confirm the exact order reference, language and software version with current ICU Medical documentation before requesting an offer. The category record reflects the PharmGuard-enabled reference 21-2120-0105; it does not mean every quote automatically includes medication-safety software, configuration, a protocol library or network deployment.

Read more

Buy ICU Medical CADD infusion pumps in Nigeria

Franance lists the ICU Medical CADD-Solis VIP 2120 ambulatory PCA infusion pump, catalogue reference 21-2120-0105, for quotation enquiries in Nigeria. ICU Medical describes the CADD-Solis VIP as an ambulatory infusion system; its catalogue distinguishes a PharmGuard-enabled blue-label version from a manual-mode standard-settings version and shows language-specific order suffixes. Before asking for a quote, specify the intended pump mode and model, PharmGuard or manual configuration, language, compatible CADD reservoirs and administration sets, accessories, quantity and destination. Clinical and biomedical engineering staff must determine whether the configuration suits the facility's approved therapy workflow. Infusion pumps are clinical equipment. This guide is for procurement and specification planning and does not provide dosing, programming or patient-care instructions. Follow the current ICU Medical Instructions for Use, local medication-safety policies and qualified clinical direction. ICU Medical states that products may not be licensed or available for sale in every country. The catalogue listing does not establish Nigerian stock, price, delivery, warranty or local service. Franance accepts quote orders and follows up by email or phone; submitting an enquiry is not an online purchase or a guarantee of supply.

Where can I buy an ICU Medical CADD-Solis VIP in Nigeria?

Open the CADD-Solis VIP category listing, which currently includes the VIP 2120 ambulatory PCA pump. Send Franance the model reference, intended mode, language code, accessories and consumables required, quantity, clinical setting and destination. If replacing or standardising existing pumps, include the current CADD model and compatible consumables, after confirming that information with biomedical engineering and pharmacy. For a tender, provide the non-confidential technical schedule and define the included disposables separately from durable equipment.

Franance can review the quote request and confirm whether it can make an offer for the requested configuration and destination. ICU Medical's international product page and catalogue describe manufacturer configurations but do not establish local Nigerian stock or the terms of any specific offer. Ask the written quote to name the exact VIP model, reference and suffix, PharmGuard or manual-mode status, language, included accessories, reservoirs and sets, software or network components, price, freight, delivery, warranty and service scope. ICU Medical advises that products may not be licensed or available for sale in every country, so ask for destination-specific availability and documentation before approval.

What is the CADD-Solis VIP 2120 ambulatory pump?

ICU Medical describes CADD-Solis VIP as an ambulatory infusion system in the CADD family. The manufacturer's catalogue lists reference 21-2120-0105-XX as a CADD-Solis VIP 2120 ambulatory infusion pump with PharmGuard enabled, and reference 21-2127-0105-XX as a manual-mode pump with standard settings. The “XX” in the catalogue reference is replaced by a language code. These configurations should not be treated as interchangeable: confirm which version matches the facility's medication-safety governance, software and programming workflow.

The pump can be used with compatible reservoirs and administration sets identified by ICU Medical. Its exact application and settings depend on the model, programming configuration, prescribed therapy, institutional protocols and current instructions for use. The product name alone does not state what is included in a kit or which consumables fit. A qualified clinician, pharmacist and biomedical engineering representative should assess the intended service and approve the pump and accessories. This guide does not advise on patient selection, drug dose, route, rate, alarm response or programming; those require current manufacturer instructions and the facility's approved clinical procedures.

Should I request PharmGuard or manual mode?

The official ICU Medical catalogue distinguishes a CADD-Solis VIP 2120 PharmGuard-enabled version, identified with a blue label, from a manual-mode version with standard settings, identified with a black label. The references use language suffixes: the manufacturer says to replace “XX” with the required language code. Confirm the exact order reference, language and software version with current ICU Medical documentation before requesting an offer. The category record reflects the PharmGuard-enabled reference 21-2120-0105; it does not mean every quote automatically includes medication-safety software, configuration, a protocol library or network deployment.

The hospital's medication-safety committee, pharmacy, nursing leadership, clinical engineering and IT team should decide whether a drug library or manual configuration is appropriate for the intended workflow. Ask what software, protocol library, administrative tools, licences, access controls, network components and configuration work are included. If an existing CADD-Solis fleet is involved, check interoperability and version requirements. Do not assume that a pump can be used with a facility's current library or that a blue-label PharmGuard pump arrives preconfigured for a clinical protocol. Have the quote specify the scope and have the responsible clinical team validate any configuration before patient use.

Which infusion modes and workflow should I specify?

ICU Medical's public product information describes CADD-Solis VIP as an ambulatory infusion pump family and references PCA, continuous infusion and clinician-bolus modes. The product record also notes taper, intermittent and step modes. The exact functions available depend on the offered configuration and applicable software. Do not infer that all modes are enabled on a specific unit or appropriate for a particular therapy. Ask the supplier to identify the applicable current instructions and to state which model, software version and configuration correspond to the intended workflow.

Describe the clinical service without transmitting patient-identifiable information: care setting, intended mobility or ambulatory workflow, required pump mode, whether the facility uses a medication-safety library, and the approved consumables. Have the clinical team define the procedures, alarm policies, training and acceptance tests. Ask ICU Medical documentation to confirm mode availability for reference 21-2120-0105-XX and for any optional configuration. Avoid including dose schedules or patient treatment plans in a general quote enquiry. Franance can help clarify the commercial line items, but the care team retains responsibility for clinical suitability, programming and patient-use protocols.

Which CADD reservoirs and administration sets should I request?

ICU Medical's CADD catalogue lists multiple compatible reservoirs, administration sets and accessories, with separate reference numbers and design features. Some sets include Flow Stop free-flow protection, filters, clamps or particular connectors; maximum rates and compatibility vary by pump generation and configuration. A general request for “CADD consumables” is not precise enough for procurement. Ask the hospital's pharmacy, nursing and biomedical engineering teams to identify the exact set and reservoir references used in the approved workflow, and verify them against current ICU Medical documentation for the specific VIP 2120.

List recurring consumables separately from the pump. Specify reservoir size, cassette or set type, connector, filter requirement, extension set, quantity, packaging, intended therapy and any required replacement parts. Ask the quotation to identify what is supplied with the pump, what is a starter pack, and what is recurring stock. Confirm expiry, storage, compatibility and availability for every disposable item. Do not substitute tubing or reservoirs based only on connector appearance or a reference for another CADD model; follow the manufacturer compatibility information and local infection-prevention and medication-safety requirements.

What software, connectivity and power requirements should I check?

The CADD catalogue describes PharmGuard software and related tools, plus optional wireless communication components and other accessories. It also lists power options for CADD-Solis pumps, such as batteries or an AC adapter, depending on the configuration. Confirm which items apply to the requested VIP 2120 and whether software is included, separately licensed, configured or not part of the offer. A catalogue listing does not establish that the facility's IT environment, wireless network or medication library is compatible or ready.

Have IT and clinical engineering assess network security, user access, software versions, protocol-library administration, update management, data retention and downtime procedures before purchasing connected components. Request ICU Medical's current technical, cybersecurity and compatibility documents for the specific model. Specify power accessories, backup plans and charging or battery requirements under the manufacturer's instructions. Ask the quote to itemise communication modules, software, licenses, setup, validation and recurring charges. Do not connect the pump to a hospital network or load a protocol library until the responsible teams have approved configuration and testing.

What training, validation and maintenance should a hospital plan?

Before a pump enters service, the hospital should define which staff will receive the device, verify configuration, maintain it and approve clinical use. Request current instructions for use, user and service documentation, any applicable software guidance and a clear statement of training or implementation services included in the quotation. Have qualified clinical staff validate intended workflows and have biomedical engineering perform the checks and maintenance prescribed for the exact model. If a PharmGuard-enabled configuration is requested, define who owns the medication library and how the facility will review and approve it.

Establish acceptance criteria before ordering: correct model and reference, language suffix, software or mode, included accessories, documentation, electrical and performance checks, configuration review and staff readiness. The exact process should follow ICU Medical instructions and local policy. Ask who handles repair, preventive maintenance, replacement parts and post-service checks, and where those services are performed. No local repair capacity, warranty coverage or response time is confirmed by the public page. Do not use the pump for patient care until clinical governance and biomedical engineering have completed required approvals and validation.

What determines the CADD-Solis VIP price in Nigeria?

The quotation can vary with the exact pump reference and language suffix, PharmGuard or manual configuration, software and protocol-library requirements, accessories, consumables, quantity, delivery destination and any agreed implementation, training or service scope. The category listing does not publish a Nigerian price. An overseas catalogue or supplier price is not an offer for a Nigerian facility and may reflect a different language, market, configuration or package. Request an itemised quotation for the intended model and accessories.

Compare offers on matching references, mode, software, batteries or power accessories, lockbox or pouch, reservoirs, administration sets, delivery and service. Check currency, quote validity, freight, taxes or duties if applicable, payment terms, warranty, exclusions and recurring software or consumable costs. ICU Medical notes that sale availability varies by country, so request written confirmation of the proposed supply route and documents for Nigeria. A quotation request is not a purchase or stock reservation. The final price and terms are those confirmed by Franance for a specific offer.

Can Franance deliver CADD-Solis pumps to my state or city?

Provide the destination hospital or clinic, city, state, receiving contact, site access details, quantity and desired timing. Franance can review the request and confirm proposed delivery terms in writing. The catalogue listing does not establish Nigerian stock, nationwide coverage, freight cost or delivery timing. ICU Medical specifically cautions that products may not be licensed or available for sale in every country; ask Franance to confirm any country-specific availability and documentation before planning installation or clinical deployment.

For multiple facilities, give each site and pump quantity separately, including any site-specific software, consumable or power requirements. Coordinate receipt with pharmacy, nursing, biomedical engineering and IT so the correct model and accessories can be checked before acceptance. Ask the offer to state who is responsible for delivery, receiving inspection, training, setup, validation, warranty and service. Confirm shipping conditions and the process for reporting damage or a discrepancy. Do not treat a general statement about Nigeria as confirmation for a particular state, city or service response.

What should I verify before accepting an ICU Medical quotation?

Confirm the model is CADD-Solis VIP 2120 and identify the exact reference and language suffix. Check whether the offer is PharmGuard-enabled or manual mode; the official catalogue assigns different references to those configurations. Verify software, medication library, network components, power accessories, pouch or lockbox, compatible reservoirs, administration sets and quantities. Ask for current instructions for use, technical documents and destination-market documentation. Have the pharmacy, clinical governance, nursing, IT, biomedical engineering and procurement teams review their respective areas.

Check the commercial terms: price and currency, quote validity, freight, taxes or duties, delivery address and timing, warranty, service, training, implementation, software licences, recurring consumables, exclusions and returns. Ask Franance to identify who will supply the equipment and who will perform any proposed local work. Do not accept a substitute mode or language without approval. Confirm that all clinical and technical configuration is validated under facility procedures before use. Keep the approved quote, device references, software details, serial number, instructions and acceptance records with the asset documentation.

How do I request a CADD-Solis VIP quotation from Franance?

Use the ICU Medical PCA pump listing and submit a quote enquiry for the CADD-Solis VIP 2120. State whether you require PharmGuard or manual mode, the preferred language code, quantity, compatible CADD reservoir and administration-set references, accessories, facility location and any non-confidential tender requirements. Do not include patient names, prescriptions, medication doses, clinical records or other sensitive health information in a general commercial enquiry.

Franance can review the quote order and follow up by email or phone. Ask the written offer to specify the model, reference suffix, software status, package, consumables, price, destination, delivery terms, warranty, training and service scope. ICU Medical's country-specific licensing notice makes it especially important to confirm market availability and required documents for the intended Nigerian site. This is a quotation workflow, not online checkout. Submission does not guarantee availability, delivery or a particular commercial term; accept only after clinical and procurement review.

Common questions

What does the ICU Medical 21-2120-0105 reference indicate?

The manufacturer's catalogue lists the VIP 2120 with 21-2120-0105-XX for PharmGuard-enabled configuration, where XX is replaced by the language code. Verify the exact ordered suffix.

Does the listing include reservoirs and administration sets?

The catalogue entry does not establish included consumables. Specify the exact compatible CADD references and ask Franance to itemise them in writing.

Is CADD-Solis VIP available in Nigeria?

ICU Medical cautions that products may not be licensed or available in every country. Request written confirmation of availability and documentation for your facility.

Request an ICU Medical CADD-Solis VIP quotation

Provide the pump reference and language suffix, configuration, approved consumables, accessories, quantity and destination. Franance can review the quote order and confirm proposed terms in writing.

Request an ICU Medical quotation

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance

Find equipment.

View cart