Buy Precision Medical 1MFA1002 Chrome Oxygen Flowmeter in Nigeria
Request a Franance quotation for the Precision Medical 1MFA1002 Chrome Oxygen Flowmeter in Nigeria. Precision Medical’s ordering tables identify this code as an oxygen flowmeter with a 0–15 L/min range and DISS female hex-nut connection. Share the outlet, pressure and exact variant required; Franance will follow up by phone or email to clarify the quote order. Browse the Precision Medical catalogue or oxygen flowmeters.
What does Precision Medical 1MFA1002 identify?
1MFA1002 is a specific model in Precision Medical’s Chrome Flowmeter series. The manufacturer identifies it as oxygen, 0–15 L/min, with a DISS female hex-nut connection. Precision Medical describes the series as pressure compensated and fitted with a polycarbonate flow tube and needle valve. Check the exact part and connection against your facility specification in the manufacturer’s Chrome Flowmeter catalogue and current flowmeter instructions.
Which alternatives should I compare before ordering?
The same manufacturer table distinguishes 1MFA1001, 1MFA1002, 1MFA1003 and 1MFA1004 by connection, and separately lists variants with right or left inlets and a power take-off. It also lists 1MFA1102 as a different oxygen range (2–26 L/min). These are not interchangeable just because the names are similar. Tell Franance the exact code, outlet standard and any suffix shown on the required unit.
What flow range and pressure should I specify?
Precision Medical lists a 0–15 L/min range with half-litre graduations from 0–5 L/min and one-litre graduations from 5–15 L/min. Its ISO catalogue presents pressure variants and suffixes, while the plain 1MFA1002 code alone does not confirm the calibration pressure for the unit being quoted. State the facility’s specified pressure and ask the offer to name the exact variant and its marked calibration.
Is a standard 1MFA1002 suitable for an MRI suite?
Do not assume so. The manufacturer instructions warn that flowmeters may contain magnetic, ferrous material that can affect MRI results; their MR Conditional statement is limited to MRI-labelled 1MFA and 8MFA series models. Ask for the exact MRI labelling and documentation if this is an MR-area requirement. The general 1MFA1002 listing is not evidence of MR Conditional status.
How do I request a 1MFA1002 quotation in Nigeria?
Send Franance the exact model code and suffix, quantity, facility outlet and pressure requirement, destination and requested accessories. We will follow up to clarify the quote order and provide written terms for the offered item. The manufacturer documents do not establish Nigerian stock, price, registration, delivery, warranty or local service; confirm those details in the quotation.
Common questions
Is 1MFA1002 the same as 1MFA1001?
No. Both are oxygen 0–15 L/min Chrome flowmeters in the manufacturer tables, but 1MFA1001 has no adaptor and a 1/8-inch NPT female connection, while 1MFA1002 has the DISS female hex-nut inlet.
Does the plain code state the calibration pressure?
Not in the ISO ordering system, which adds C, AU or CI for 50 psi, 4.14 bar or 5 bar. The 2026 standard catalog lists 50 psi. Confirm the pressure marked on the offered unit.
Is a humidifier bottle included?
Not unless the quotation lists it. Precision Medical lists humidifiers, tubing nipples and the Night Check as separate items.
Request your 1MFA1002 Chrome Oxygen Flowmeter quotation from Franance.
Send Franance the complete 1MFA1002 code and suffix, quantity, outlet type and supply pressure, inlet position, knob colour convention, any accessories and the Nigerian delivery destination.
Choose quantity