Buy Eppendorf CryoCube F570h Ultra-Low Temperature Freezer in Nigeria
To request an Eppendorf CryoCube F570h ultra-low temperature freezer in Nigeria, specify catalogue number F571340031 and ask for confirmation of the electrical variant, storage racks, room heat load, power continuity plan and any backup or remote-monitoring options. Eppendorf’s India product page lists this F570h as a 570 L, air-cooled freezer with vacuum-insulated panels, hydrocarbon refrigerants, five compartments and a 230 V/50 Hz configuration. These specifications identify a regional model; they do not confirm that this exact reference is available for Nigerian supply or that a laboratory site is ready to install it. Review the exact F570h catalogue listing, the F570h product-filtered category listing, or all ultra-low temperature freezer listings. For a Franance quotation for CryoCube F570h F571340031, include the sample-box layout, room and electrical details, delivery city and any separate installation, backup or monitoring request. Franance handles quote orders; there is no online checkout and the listing does not confirm local price or stock.
Where can I buy a CryoCube F570h in Nigeria?
Send Franance a quotation request that names the Eppendorf CryoCube F570h and catalogue number F571340031. Include the quantity, institution, laboratory contact, destination city and state, receiving access and procurement-document requirements. Tell the supplier whether the freezer is for an existing storage room or a new facility, what kinds of sample boxes are planned, the expected rack arrangement and any need for alarms, remote monitoring, backup systems or sample-management tools.
Ask the quote to identify the exact order reference and regional electrical version, freezer, rack and box quantities, backup accessories, monitoring components, installation or handover tasks, and any optional services. Request each line be marked included, optional, separately quoted, excluded or pending technical confirmation. A catalogue image does not prove that racks, boxes, a chart recorder, CO₂ or LN₂ backup, remote monitoring, installation, commissioning or a service agreement is included.
The India product page documents a 230 V/50 Hz version with catalogue reference F571340031. It is evidence for that manufacturer-listed regional variant, not evidence of current Nigerian inventory, distribution, certification, warranty or delivery. The supplier should confirm the exact version and commercial terms in writing. Franance follows up on quotation requests by phone or email; submission does not reserve a freezer or complete an online purchase.
What is the Eppendorf CryoCube F570h?
The CryoCube F570h is an upright ultra-low temperature laboratory freezer in Eppendorf's F570 series. The manufacturer describes a 570 L capacity class and a temperature range of −50 °C to −86 °C. Eppendorf lists the h model with polyurethane foam and vacuum-insulation panels, air cooling and hydrocarbon refrigerants R290/R170. The product reference in this catalogue is F571340031, the listed left-handle, five-compartment ACT-labeled 230 V/50 Hz configuration.
The “h” matters because the F570 family also includes F570n and F570hw. The F570n uses polyurethane insulation without the vacuum panels, while F570hw uses water cooling. Their order references and technical details differ. A seller offering an F570n, F570hw or a different electrical variant is offering a different model configuration. Ask that any proposed substitution be named explicitly and reviewed against the site's heat-removal and utility requirements.
Eppendorf describes the series as a laboratory sample-storage freezer with a five-compartment layout and five insulated inner doors. That design lets users access a compartment while limiting opening of the full external door, but actual temperature recovery in a particular lab depends on operating conditions and load. The product page's dynamic performance language does not guarantee that every sample will remain within a facility's required range during every door opening, power interruption or fault. The laboratory needs an approved storage and contingency plan.
How much sample storage capacity does the F570h provide?
Eppendorf's current F570 series table lists 570 L capacity, five compartments, up to 25 racks and a maximum of 400 freezer boxes at 53 mm box height in the manufacturer's stated rack arrangement. The same table lists different totals for other box heights: up to 300 at 64 mm; 200 at 76 mm; 200 at 102 mm; and 200 at 127 mm. These figures depend on the manufacturer's rack layout and compatible box sizes, not simply the nominal freezer volume.
Build a real inventory plan before selecting racks. Count current boxes by height and footprint, specify the preferred access style, note existing rack references and estimate additional capacity. Ask Eppendorf or the supplier to run the proposed rack and box schedule through the current compatibility tool and provide a drawing. Confirm the rack material (the manufacturer lists aluminum or stainless-steel options), number of racks, drawer or side-access layout and any compartment-height adjustment. Do not assume that every rack in a laboratory fits every ULT freezer.
If the freezer is replacing an existing unit, map its physical rack coordinates and sample-management system to the new rack layout. A freezer with sufficient nominal liters may still require changes to box formats, rack access, labels or inventory records. If additional freezer boxes are needed, quote them separately by exact reference and quantity. Do not treat the maximum box figure as evidence that the freezer ships with 400 boxes or 25 racks.
What are the F570h's power, energy and heat requirements?
The manufacturer lists catalogue F571340031 at 230 V, 50 Hz and type F/type G plugs. The published specification table reports average daily consumption of 7.4 kWh/day at 230 V, heat output of 308 W and noise level of 57.2 dBA under its stated basis. These values help a facility begin planning, but they are not an electrical load study or a guarantee of energy use in a Nigerian lab. Ambient conditions, door openings, load, ventilation, power quality, installation and maintenance affect actual operation.
Have facility engineering review the exact voltage, frequency, circuit rating, plug, earthing, breaker, wiring, protection and supply continuity against the current installation manual. Do not assume that an outlet near the intended location is suitable for a continuous-duty ultra-low freezer. Ask whether the supplier's offer includes a power cord, plug, protective device or any site modification, and have a qualified electrical professional determine the correct connection.
Cooling equipment transfers heat to the room. Use Eppendorf's 308 W listed heat output as a site-planning input, then have mechanical engineering assess room cooling capacity, airflow, clearance and heat load alongside other equipment. The air-cooled F570h relies on the room's ability to remove its emitted heat. A hot, crowded or poorly ventilated room may not meet the environmental conditions required by the manufacturer. For rooms where air cooling is unsuitable, discuss the separate water-cooled F570hw option with the supplier and facility team rather than assuming the F570h can use water cooling.
What clearance and room conditions should I confirm?
The listed F570h dimensions are 110.3 × 89.8 × 195.0 cm, with a footprint of approximately 110.3 × 89.9 cm. The specification notes that additional clearance is needed for hinges, handles and door opening. Measure the room, doorway, lift, corridor, turning space, floor route and final service access before ordering. The freezer weighs about 341 kg as a product and has manufacturer-listed shipping weight of 388 kg, so the receiving route, floor loading and installation handling need qualified review.
Request current installation planning data that specifies side, rear and top clearances, air intake and exhaust, operating ambient limits and service access. Confirm how much door swing space is required and whether the left-side handle configuration suits the room layout. Have the site team verify the floor, level surface, path of travel and any threshold or elevator restrictions. A product page's external dimensions do not replace a full installation drawing.
Because the model is air-cooled, room heat removal and airflow matter. Ask the site engineer to include the freezer's heat output in the total cooling load and define how the room will stay within the manufacturer's environmental limits during normal use and during a power or air-conditioning interruption. The supplier should identify any specific ambient-temperature limits and ventilation requirements from the current installation manual. Do not infer these from the freezer's −86 °C setpoint range.
How should the lab plan power continuity and sample protection?
An ULT freezer protects irreplaceable samples only when the whole storage system is planned. The Eppendorf series page says CO₂ or LN₂ backup systems can be added and remote temperature monitoring can be used. These are optional systems, not part of the F570h base unit by implication. Ask the manufacturer which backup configuration is compatible with catalogue F571340031, which parts are required, how it is installed, and what controls, sensors, gas supply, alarms or monitoring subscriptions are included.
The lab should document its power outage response, alarm escalation, backup-gas availability, monitoring responsibility, emergency contacts, sample-transfer destination and access control. Have the biosafety, quality and laboratory teams set the required storage range and response thresholds for their samples. This guide does not recommend clinical or scientific storage setpoints or a backup duration. Any claimed holdover or autonomy duration must be supported by exact model and test-condition documentation.
Ask whether monitoring is local, remote or network-based, what connectivity and subscription it requires, how notifications are delivered, and who configures and maintains it. A product page's mention of remote monitoring does not establish that a monitoring box, service, network integration or mobile alert is included in a Nigerian offer. For critical repositories, request a separate backup and monitoring proposal that lists compatible parts, utilities, recurring fees and test/maintenance responsibilities.
How should I read Eppendorf's pull-down and recovery data?
Eppendorf reports a pull-down time to −80 °C for the F570h in its product specifications. The published figure comes from defined manufacturer test conditions; the product record notes that its pull-down data use an empty freezer with shelves from stated 21–23 °C ambient conditions. That is not a promise for a loaded freezer, a hot Nigerian room, a specified sample load or a facility with unstable power. Ask for the exact test conditions, data-sheet revision and recovery method if the figure matters to a project.
Similarly, descriptions of fast recovery after openings relate to manufacturer testing and the overall series design. Real use depends on door-open duration, how often staff access the freezer, ambient temperature, load, seals, rack layout and power. Design a sample access workflow that reduces unnecessary door-open time, but rely on facility monitoring and approved procedures rather than assuming the freezer will instantly return to a setpoint after any event.
The freezer is not a substitute for validated storage monitoring, alarm response, backup, maintenance or sample-management procedures. Ask for the temperature-control and alarm specifications, any independent monitoring options, calibration or verification instructions and required service schedule for the exact unit. Have qualified laboratory personnel establish acceptance testing and the sample transfer plan before placing irreplaceable material into service.
Which F570 series variant should I request?
F570h is air-cooled and combines polyurethane foam with vacuum insulation panels. F570n is also air-cooled but lacks the vacuum panels. F570hw uses water cooling with vacuum panels. Eppendorf lists all three at 570 L, five compartments and 230 V/50 Hz for the regional page, but heat output, energy use, weight, dimensions and other specifications differ. The water-cooled F570hw has facility water requirements; Eppendorf lists water flow and inlet-pressure ranges for this option, which should be reviewed in the current documentation if that model is considered.
The present Franance product record is the F570h. If the site depends on a particular cooling configuration, power arrangement, ACT designation, handle direction, display or rack setup, ask the supplier to confirm the offered reference before comparing prices. Do not use an F570n or F570hw fact as if it described F570h. The Eppendorf F570h filter isolates this specific catalogue listing, while the category page shows the current Franance freezer records.
What should the installation and delivery plan include in Nigeria?
Give the final delivery location, site contact, receiving hours, access route, loading dock or lift details, room location, and any institutional import or tender documents in the quote request. Ask the supplier to state packing, shipping, unloading, internal movement and placement responsibilities. Confirm whether door removal, temporary storage, lifting equipment or a site survey is required and which party supplies it. Do not assume delivery to an address includes moving a 388 kg shipping unit through the building or placing it in a laboratory.
Ask whether installation, start-up, commissioning, alarm testing, temperature verification, monitoring setup and operator orientation can be provided at that Nigerian site. If any are offered, require the provider, scope, timing, prerequisites, fees and exclusions in writing. The catalogue and Eppendorf regional page do not establish local installation support, warranty, repair response, spare-part stock or service coverage. Verify these details before purchase, including the responsible party if the equipment has to be serviced after installation.
Discuss shipping and commissioning conditions with the supplier. Confirm that the freezer has the required electrical supply, environmental conditions and clearance before scheduling arrival. Ask for storage, handling and arrival inspection instructions. The facility should plan a contingency for sample storage during transport and installation; this guide does not guarantee immediate readiness after delivery.
What documents should procurement request?
Request the current F570h technical specification, installation manual, rack compatibility data, electrical requirements, environmental limits, alarm/backup documentation and maintenance schedule for catalogue F571340031. Ask the supplier to provide any current certification or conformity documentation required by the facility, but do not assume a label shown in product literature proves Nigerian regulatory approval. If the ACT label or energy figures matter to procurement, ask for the current record and conditions associated with the specific model.
Ask for a detailed contents and accessories schedule listing freezer, racks, boxes, backup system, monitoring equipment, chart recorder, software, power accessories, documentation and services separately. Have laboratory engineering, biosafety, quality, facilities and procurement teams review the relevant elements. The manufacturer's product page contains several F570 versions and accessories; a generic family brochure is not enough to establish the contents of a specific commercial offer.
What should I include in a CryoCube F570h quote request?
To receive a useful quotation from Franance, include:
- Eppendorf CryoCube F570h, catalogue number F571340031, quantity and required 230 V/50 Hz configuration.
- Laboratory, sample repository, procurement contact and delivery city/state in Nigeria.
- Existing and planned freezer-box heights, quantities, rack references and preferred access style.
- Room dimensions, ventilation, ambient conditions, circuit details, power continuity and cooling capacity for site review.
- Required CO₂/LN₂ backup, alarm and remote monitoring scope, each as a separate item to confirm.
- Requested installation, movement into the building, commissioning, monitoring setup, verification and training.
- Current product documentation, rack layout, warranty/service terms and any institutional compliance paperwork.
- Delivery, shipping, unloading, taxes, quote validity, payment and procurement requirements.
Ask the supplier to return an itemised offer and list every assumption or exclusion. A freezer-only quote should be distinguished from a fully equipped storage solution. Begin with the F570h exact catalogue listing and contact Franance for an F570h quotation. This is a quotation request followed by contact, not online payment.
Manufacturer sources and limitations
- Eppendorf India: CryoCube F570 Series ULT Freezer — model reference, regional electrical variant, insulation, capacity, cooling, sample-box capacities and published specifications. Accessed 20 October 2026. - Eppendorf F570 series installation and technical documents — use the manufacturer's current downloads to confirm site, maintenance and accessory requirements for the offered reference.
Published values are Eppendorf specifications for stated models and conditions. They do not establish performance in a specific room, Nigerian supply availability, warranty, regulatory approval, service, sample safety or project suitability. Confirm current documents, compatibility, site readiness and commercial terms for catalogue F571340031 in a written offer.