Electrochemical oxygen sensor cartridge for an anesthesia workstation

Confirm the exact product reference and supplied package with your quotation.

Dräger

Buy Dräger OxyTrace A Oxygen Sensor 6871028
in Nigeria.

Oxygen sensor for anesthesia workstation

Request a Franance quotation for Dräger OxyTrace A oxygen sensor 6871028 in Nigeria. Dräger lists this reference for Zeus Infinity Empowered. Send the exact workstation model, serial number and installed sensor label so the replacement can be checked against the device configuration before an order is prepared.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • Manufacturer ordering reference 6871028
  • OxyTrace A sensor type
  • Dräger-listed application: Zeus Infinity Empowered
  • Model and serial-number confirmation required before quotation
Dräger OxyTrace A Oxygen Sensor 6871028 specifications
ManufacturerDräger
SensorOxyTrace A
Part number6871028
Listed applicationZeus Infinity Empowered
Measurement range0 to 100 Vol.% oxygen
T10–90 response time5 seconds
Dimensions20 mm diameter × 33.6 mm height

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

Which equipment is 6871028 listed for?

Dräger's ordering table identifies OxyTrace A as part 6871028 and specifies it for Zeus Infinity Empowered. Confirm your Zeus device version, serial number and installed sensor reference before treating it as the right part.

Read more

What specifications does Dräger publish?

The product information gives OxyTrace A a 0 to 100 Vol.% oxygen measuring range, a 5-second T10–90 response time, and dimensions of 20 mm diameter by 33.6 mm height. Dräger lists the OxyTrace A / VE family as electrochemical oxygen sensors, each with its own application and ordering references.

Read more

Is it the same as other Dräger oxygen sensors?

No. This is OxyTrace A 6871028, not OxyTrace VE MX01049, oxygen sensor capsule 6850645 or Oxycell 6872666. Do not order by "oxygen sensor" alone, and do not assume a sensor from another Dräger device will fit.

Read more

Buy Dräger OxyTrace A Oxygen Sensor 6871028 in Nigeria

The OxyTrace A, part 6871028, is an electrochemical oxygen sensor from Dräger listed for the Zeus Infinity Empowered. Sensors are model-specific, so confirming the match matters more than any other detail.

Which equipment is 6871028 listed for?

Dräger's ordering table identifies OxyTrace A as part 6871028 and specifies it for Zeus Infinity Empowered. Confirm your Zeus device version, serial number and installed sensor reference before treating it as the right part.

What specifications does Dräger publish?

The product information gives OxyTrace A a 0 to 100 Vol.% oxygen measuring range, a 5-second T10–90 response time, and dimensions of 20 mm diameter by 33.6 mm height. Dräger lists the OxyTrace A / VE family as electrochemical oxygen sensors, each with its own application and ordering references.

Is it the same as other Dräger oxygen sensors?

No. This is OxyTrace A 6871028, not OxyTrace VE MX01049, oxygen sensor capsule 6850645 or Oxycell 6872666. Do not order by "oxygen sensor" alone, and do not assume a sensor from another Dräger device will fit.

What should a Nigerian buyer confirm before ordering?

Send the Zeus model, serial number and the reference on the installed sensor, and ask about expiry and storage. Replacement, calibration and post-installation function checks must follow current Dräger instructions and be done by qualified personnel. Stock, price, regulatory status and delivery time are not established and are not claimed. The catalogue image is a generic generated visual, not the exact sensor.

How can I request a quote in Nigeria?

Add the item to Franance's quote cart at /quote-order.html. State the quantity, your Nigeria destination and the configuration you need, including the Zeus model and serial number. Franance follows up with a written quotation. Adding an item is a request, not a payment or a confirmation of availability.

Manufacturer source

Dräger O2 sensors product information and ordering table

Related links

- Dräger products
- Relevant product category
- Request a quotation

Common questions

Which equipment is 6871028 listed for?

Dräger's ordering table identifies OxyTrace A as part 6871028 and specifies it for Zeus Infinity Empowered. Confirm your Zeus device version, serial number and installed sensor reference before treating it as the right part.

What specifications does Dräger publish?

The product information gives OxyTrace A a 0 to 100 Vol.% oxygen measuring range, a 5-second T10–90 response time, and dimensions of 20 mm diameter by 33.6 mm height. Dräger lists the OxyTrace A / VE family as electrochemical oxygen sensors, each with its own application and ordering references.

Is it the same as other Dräger oxygen sensors?

No. This is OxyTrace A 6871028, not OxyTrace VE MX01049, oxygen sensor capsule 6850645 or Oxycell 6872666. Do not order by "oxygen sensor" alone, and do not assume a sensor from another Dräger device will fit.

What should a Nigerian buyer confirm before ordering?

Send the Zeus model, serial number and the reference on the installed sensor, and ask about expiry and storage. Replacement, calibration and post-installation function checks must follow current Dräger instructions and be done by qualified personnel. Stock, price, regulatory status and delivery time are not established and are not claimed. The catalogue image is a generic generated visual, not the exact sensor.

How can I request a quote in Nigeria?

Add the item to Franance's quote cart at /quote-order.html. State the quantity, your Nigeria destination and the configuration you need, including the Zeus model and serial number. Franance follows up with a written quotation. Adding an item is a request, not a payment or a confirmation of availability.

Request your Dräger OxyTrace A 6871028 quotation from Franance.

Add Dräger OxyTrace A Oxygen Sensor 6871028 (OxyTrace A / 6871028) to the Franance quote cart with quantity, destination and required configuration. Franance will confirm the offered specification and terms in writing.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Electrochemical oxygen sensor cartridge for an anesthesia workstation

Find equipment.

View cart