Round adhesive ECG electrodes with conductive gel centers and metal snap connectors

Confirm the exact product reference and supplied package with your quotation.

Ambu

Buy Ambu BlueSensor P Single-Use ECG Electrode P-00-S/50
in Nigeria.

Single-use adhesive ECG electrode

Request a Franance quotation for Ambu BlueSensor P ECG electrodes, reference P-00-S/50, in Nigeria. Ambu describes this single-use wet-gel electrode for short-term applications and says it can be used on children. Confirm the intended monitor connection, application requirements and required pack quantity before ordering.

Your quotationPrice on request

Call to order, or add items for one quotation. We’ll confirm pricing and delivery.

Call to order+234 906 408 1910
Add a note or configuration
View your quote cart

Add to cart to review your items and request a quotation. We’ll follow up by phone or email.

Specifications

  • Single-use wet-gel ECG electrode
  • Offset connector design described by Ambu
  • P-00-S/50 is a listed manufacturer reference
  • Manufacturer describes short-term use and notes the electrode can be used on children
Ambu BlueSensor P Single-Use ECG Electrode P-00-S/50 specifications
ManufacturerAmbu
Product familyBlueSensor P
ReferenceP-00-S/50
Use formatSingle use
Electrode gelWet conductive gel
ConnectorOffset connector
Application durationShort term, as described by the manufacturer
Pack quantityConfirm the current package specification with the quotation

Reference: Manufacturer product information ↗. Regional options may vary. Confirm the exact model configuration, accessories and documentation with the quotation.

Quote before you order.

Tell us the quantity and configuration. Price and availability are confirmed with you before an order is agreed.

Delivery in Nigeria.

Include your facility address and required date so delivery arrangements can be included in the quotation.

Equipment support.

Ask for installation, training or maintenance to be specified where needed. The agreed scope will be listed in writing.

Where can I buy Ambu BlueSensor P P-00-S/50 in Nigeria?

Request a quotation from Franance for Ambu BlueSensor P Single-Use ECG Electrode P-00-S/50. This exact-filter listing shows the assigned Ambu model in the ECG electrodes category. Include the number of pouches or units needed, your ECG monitor/lead-wire connector information, delivery destination and any facility purchasing requirements.

Read more

What is Ambu BlueSensor P P-00-S/50?

BlueSensor P P-00-S/50 is a single-use ECG electrode. Ambu describes the BlueSensor P family as a small wet-gel electrode with an offset connector and adhesive intended for short-term applications. The manufacturer says the P electrode can be used on children, but this is not a patient-specific selection recommendation. Use the device instructions and local clinical protocol to determine whether this size and configuration are appropriate for a particular patient or monitoring task.

Read more

How do I decode the P-00-S/50 reference and pack size?

Use the complete model code in the enquiry. Ambu’s product page lists P-00-S/50 among BlueSensor P product numbers, while its datasheet explains that S denotes a stud connector. The /50 variant is listed with 50 units per pouch, one unit per liner, and the document’s packaging table also gives inner- and outer-box quantities. Ambu cautions that some configurations may not be available worldwide. Therefore, specify P-00-S/50 exactly and have Franance confirm the quoted order unit and outer packaging; do not assume that “/50” means a carton of 50 pouches.

Read more

Buy Ambu BlueSensor P P-00-S/50 ECG electrodes in Nigeria

Buy Ambu BlueSensor P P-00-S/50 ECG electrodes in Nigeria through Franance by confirming that the electrode’s connector and product reference match the facility’s ECG lead wires, then requesting a quote for the required pouch and box quantities. Ambu identifies P-00-S/50 as a single-use BlueSensor P electrode with conductive wet gel and an offset stud connector. The manufacturer describes this BlueSensor P model as suitable for short-term applications and says it can be used on children; clinicians and the facility protocol determine patient use and placement. The product is an electrode, not an ECG monitor or complete lead set. The supplied P-00-S/50 is listed as non-wired: the electrode connector mates with a compatible lead wire selected for the monitor. Check the physical connector type and instructions for the specific ECG system before ordering. Ambu’s datasheet lists 50 electrodes per pouch for P-00-S/50, with larger inner- and outer-box quantities; its catalogue notes that some configurations may not be available worldwide. Confirm the current pack configuration and order unit in the Franance quotation.

Where can I buy Ambu BlueSensor P P-00-S/50 in Nigeria?

Request a quotation from Franance for Ambu BlueSensor P Single-Use ECG Electrode P-00-S/50. This exact-filter listing shows the assigned Ambu model in the ECG electrodes category. Include the number of pouches or units needed, your ECG monitor/lead-wire connector information, delivery destination and any facility purchasing requirements.

Franance uses a quote-order process for this product, not an online purchase or card checkout. The team follows up by phone or email to clarify the request and commercial terms. A public manufacturer page listing the model is not proof of current Nigerian stock, delivery time, local distribution status or price. Ask the quotation to confirm what can be supplied, the pack size, validity and delivery terms for your destination.

What is Ambu BlueSensor P P-00-S/50?

BlueSensor P P-00-S/50 is a single-use ECG electrode. Ambu describes the BlueSensor P family as a small wet-gel electrode with an offset connector and adhesive intended for short-term applications. The manufacturer says the P electrode can be used on children, but this is not a patient-specific selection recommendation. Use the device instructions and local clinical protocol to determine whether this size and configuration are appropriate for a particular patient or monitoring task.

Ambu’s datasheet for BlueSensor P specifies a 40 × 34 mm electrode, a 34 mm skin-contact diameter, wet-gel system, silver/silver-chloride (Ag/AgCl) sensor and 154 mm² gel area. The datasheet identifies the connector option “S” as a stud and lists P-00-S/50 as a 50-unit pouch configuration. It also identifies P-00-S/10, P-00-S/12 and alternatives with other connector options as separate references. Confirm the reference printed on the package rather than treating every BlueSensor P code as interchangeable.

How do I decode the P-00-S/50 reference and pack size?

Use the complete model code in the enquiry. Ambu’s product page lists P-00-S/50 among BlueSensor P product numbers, while its datasheet explains that S denotes a stud connector. The /50 variant is listed with 50 units per pouch, one unit per liner, and the document’s packaging table also gives inner- and outer-box quantities. Ambu cautions that some configurations may not be available worldwide. Therefore, specify P-00-S/50 exactly and have Franance confirm the quoted order unit and outer packaging; do not assume that “/50” means a carton of 50 pouches.

The same product family includes multiple part-number variants: for example, P-00-S/10 and P-00-S/12 are different pouch references, while P-00-A/50 and P-00-F/50 use other connector options. The prefix P identifies the BlueSensor P family. The manufacturer’s datasheet identifies “S” as a stud connector, “A” as a 4 mm fitting and “F” as a 3 mm fitting. The complete reference is essential to prevent substitution of a connector that does not match the department’s lead wire.

Check the package label for expiry or use-by information and storage conditions, and follow the current manufacturer instructions. Remaining shelf life is lot-specific and cannot be determined from the model code. If your procurement standard requires a minimum remaining period, state that requirement in the quotation request and confirm it against the offered lot.

Will P-00-S/50 fit my ECG monitor lead wires?

The model is listed with a stud connector, but compatibility depends on the lead wire end as well as the monitor system. Before ordering, check the ECG monitor’s lead set or accessory manual for the electrode connection required, and compare it with the actual P-00-S/50 connector. If the facility uses a 4 mm banana fitting or 3 mm fitting rather than a stud, ask the supplier about the correct BlueSensor P reference instead of forcing a connection or relying on an image.

Provide the ECG monitor make and model, lead-wire reference, connector type and department use in the quote enquiry. For legacy systems, share a clear description or documentation of the lead end; do not send patient data. Ask Franance to confirm the specified electrode is compatible with that lead-wire configuration based on supplier/manufacturer documentation. This guide cannot confirm every monitor, adapter or third-party lead combination.

The electrode itself does not include the ECG monitor or lead wires. Ambu identifies this reference as a non-wired connector option. Confirm whether the requested order is only electrodes or whether compatible patient cables, leads or accessories are being quoted separately. Keep the actual electrode and accessory product numbers visible on the final quote.

How does BlueSensor P compare with other ECG electrode types?

Choose by the product’s documented connection, size, gel, adhesive and application characteristics, not by brand alone. Ambu’s P-00-S/50 has a stud connector and short-term-use positioning. BlueSensor P also appears in other pack and connector variants. The product page lists BlueSensor P-00-A/50 and P-00-F/50 separately; the datasheet says A is a 4 mm fitting and F is a 3 mm fitting. Those references should not be substituted without checking the receiving lead-wire connector.

Ambu describes BlueSensor SP as a different, medium-sized electrode for stress-test and short-term monitoring; it is a distinct product family, not another name for P-00-S/50. Ambu BlueSensor R is described as extra-large. BlueSensor N is described as small and narrow and recommended for pediatric monitoring. These manufacturer descriptions show that model families can differ in size and positioning. They do not determine which electrode is clinically appropriate for an individual patient or procedure; follow the clinical service’s protocol and the relevant product instructions.

The wider category also lists ECG electrodes from other brands and product lines. A generic description such as “snap ECG electrode” is not enough to establish equivalent dimensions, gel, adhesive, intended duration or connector. When comparing alternatives, verify exact SKU, connector and package count with the responsible biomedical/clinical team and require the offered product to match the approved technical specification.

What do the wet gel and offset stud connector mean?

Ambu says conductive wet gel helps lower skin impedance and optimize contact, and identifies an Ag/AgCl sensor in the BlueSensor P datasheet. Its offset connector is positioned away from the center of the electrode. Ambu describes the offset design as mitigating the effect of external forces such as lead-wire pulling or pressure on the electrode, and as allowing connection/disconnection without applying pressure directly to the sensor area. These are manufacturer-described design benefits, not a guarantee of a noise-free trace or a substitute for correct application, lead management, device setup or clinical interpretation.

The electrode is single use. Ambu’s datasheet says the product is not made with natural rubber latex and the packaging is PVC-free; it separately lists PVC-containing materials in the electrode construction. If a patient or institution has material sensitivities or restrictions, review the exact datasheet and IFU with the responsible clinician and procurement team rather than relying on a broad “latex-free” or “PVC-free” shorthand. Do not reuse an electrode or apply it outside the manufacturer’s instructions.

How should facilities handle ECG electrode procurement and use?

For procurement, standardize the exact product reference, connector, pouch and box quantities, intended monitoring context, delivery destination and reorder trigger. Confirm the receiving stockroom can identify BlueSensor P P-00-S/50 distinctly from other P-family variants. Agree how the department checks the product code and package expiry on receipt, and how it follows manufacturer storage and disposal instructions. These are supply-process decisions for the facility; this guide does not replace the manufacturer’s IFU or institutional procedure.

For use, follow Ambu’s current instructions for use and local clinical protocols for skin preparation, placement, lead connection, monitoring duration, removal and disposal. The manufacturer’s product page provides the wet-gel ECG-electrode IFU download. The product listing’s statement that BlueSensor P can be used on children does not specify pediatric sizing by age, weight or body site, and it is not a placement guide. A clinician should determine the electrode arrangement and appropriateness for the patient and recording.

The datasheet states the electrode is not radiolucent and is not MR Conditional. Do not treat the electrode as suitable for MRI or X-ray imaging workflows on the basis of the BlueSensor name. If monitoring is required during imaging, ask the responsible imaging and biomedical teams to identify an electrode and lead system documented for that environment, and verify exact product instructions and device compatibility.

What should I include in an Ambu P-00-S/50 quotation request in Nigeria?

Send Franance the exact product name and reference, desired number of individual electrodes or 50-unit pouches, quantity of cartons if known, required connector and the ECG monitor/lead-wire make and model. State the facility name, destination city/state, delivery contact and any receiving, documentation or lot/expiry requirements. If the site already uses an Ambu electrode, include the existing reference from the package label so the quote can be checked against it.

Ask the quotation to state the supplied model code, pouch and box configuration, quantity basis, product expiry or remaining shelf-life information where available, delivery charges and timing, quote validity, payment terms, any substitution policy, and what happens if the requested configuration cannot be supplied. Ask for substitutions to be presented for approval rather than silently replacing the reference. Confirm whether the item is being quoted as a consumable only or with separate ECG cables/accessories.

No stock, price, lead time, Nigerian regulatory status, distributor relationship or local service entitlement is asserted by this guide. These are commercial or market-specific facts and must be confirmed for the actual order. For a broader product comparison, browse the ECG electrodes category. To submit the quote order, contact Franance about Ambu BlueSensor P P-00-S/50; the team will follow up by phone or email. There is no online checkout for this product.

Frequently asked questions about Ambu BlueSensor P P-00-S/50

### Is P-00-S/50 a 50-piece pouch? Ambu’s datasheet lists P-00-S/50 as 50 units per pouch, with 1 unit per liner and separate inner/outer box quantities. It notes that some configurations may not be available worldwide. Confirm the current order unit and packaging in the Franance quote.

### Is the P-00-S/50 connector a stud or banana fitting?
The Ambu datasheet defines S as a stud connector. Ambu lists A as a 4 mm fitting and F as a 3 mm fitting under other product references. Confirm the ECG lead-wire connector before ordering.

### Can I use this electrode on children?
Ambu states BlueSensor P can be used on children. That statement does not specify individual patient selection, age-based sizing or placement; follow the clinician’s decision, product instructions and local procedure.

### Is this product suitable for MRI or X-ray imaging?
Ambu’s datasheet lists this electrode as not radiolucent and not MR Conditional. Do not assume it is appropriate for those settings. Have the imaging and biomedical teams verify an exact alternative and its documentation if needed.

### Can the electrode be reused?
No. Ambu identifies the BlueSensor P as single use. Follow the current IFU for application, removal and disposal.

### Does it include an ECG monitor or lead wire?
No. It is a single-use electrode with a non-wired stud connector. Confirm that the facility has a compatible lead wire; quote cables or other accessories separately if required.

### Can I order it online?
No. Submit a quote request through Franance. The team follows up by phone or email to confirm the order details and commercial terms.

Sources and product limitations

Ambu manufacturer references reviewed: BlueSensor P product page, BlueSensor P datasheet, BlueSensor catalogue, and the product page’s current wet-gel ECG electrodes instructions for use download. Product distinctions were checked against Ambu’s official BlueSensor SP, BlueSensor R and BlueSensor N product pages.

Technical details in this guide are limited to Ambu’s current publicly listed product information and the referenced datasheet. Confirm the label, packaging, revision-specific IFU, compatibility and commercial terms for the item actually quoted. The guide does not provide ECG setup or patient-placement instructions, diagnose or interpret results, establish patient suitability, or claim Nigerian registration, stock, price, delivery timing or local distribution.

Request your Ambu BlueSensor P ECG electrode, P-00-S/50 quotation from Franance.

Choose quantity

Need an equipment quote?

Add the models you need to a quote order, or send us your equipment list.

Contact Franance
Round adhesive ECG electrodes with conductive gel centers and metal snap connectors

Find equipment.