Background
Verified Supplier in Zimbabwe

Biosafety Cabinets (Class II) in Zimbabwe Available Biosafety Cabinets (Class II) Models

Buy Biosafety Cabinets (Class II) in Zimbabwe. Top suppliers, installation, and warranty from Franance Health.

Speak to Expert

Certified Protection

Class II Biosafety Cabinets in Zimbabwe ensure operator, product, and environmental protection through HEPA filtration and directed airflow.

Microbiological Containment

These cabinets are essential for safe handling of biological agents in laboratories across Zimbabwe, preventing aerosolized contamination.

Reliable Performance

Zimbabwe's vital research and healthcare sectors rely on the consistent and robust containment performance of Class II Biosafety Cabinets.

What Is A Biosafety Cabinet (Class Ii)?

A Class II Biosafety Cabinet (BSC) is a specialized, enclosed workspace designed to protect both the user and the environment from potentially hazardous biological agents. It achieves this through a carefully engineered system of airflow and filtration. The primary function of a Class II BSC is to provide a sterile work area for handling infectious microorganisms, cell cultures, and other biological materials that pose a risk of infection or contamination. This protection is achieved by drawing air from the laboratory environment into the cabinet and passing it through high-efficiency particulate air (HEPA) filters. These HEPA filters remove at least 99.97% of airborne particles 0.3 micrometers in diameter, including bacteria, viruses, and fungal spores. The filtered air is then recirculated within the cabinet, creating a clean workspace for the user, and a portion of this filtered air is exhausted back into the laboratory, creating a protective air barrier at the cabinet opening.

  • Protection of personnel from infectious aerosols.
  • Protection of the product (e.g., cell cultures) from contamination by airborne microorganisms.
  • Protection of the environment by filtering exhausted air.
  • Facilitation of aseptic techniques in clinical and research settings.
  • Reduction of cross-contamination between samples.

Who Needs Biosafety Cabinets (Class Ii) In Zimbabwe?

In Zimbabwe, the need for Biosafety Cabinets (Class II) extends across a range of healthcare and research facilities where the manipulation of biological agents poses a risk to personnel, the environment, and the community. These advanced containment systems are crucial for safeguarding operations and ensuring accurate diagnostic and research outcomes.

  • Teaching Hospitals and University Medical Centres: Essential for clinical laboratories performing complex diagnostic testing, microbiology, virology, and molecular diagnostics. They also support research departments engaged in infectious disease studies, drug discovery, and advanced cellular research.
  • Public Health Laboratories: Including those managed by the Ministry of Health and Child Care, responsible for disease surveillance, outbreak investigations, and diagnostic testing for a wide spectrum of pathogens. This is vital for national health security.
  • Private Diagnostic Laboratories: Catering to a growing demand for specialized medical testing, these labs require Class II BSCs for safe handling of clinical samples, including those suspected of containing highly contagious agents.
  • Research Institutes and Biotechnology Companies: Facilities involved in cutting-edge biological research, vaccine development, genetic engineering, and the study of emerging infectious diseases will find Class II BSCs indispensable for their critical work.
  • Blood Banks and Transfusion Services: To ensure the safety of blood products and to perform quality control testing on collected samples, minimizing the risk of transmission of blood-borne pathogens.
  • Veterinary Laboratories: When dealing with zoonotic diseases or performing diagnostic tests on animal samples that may harbour human-pathogenic microorganisms.
  • Tertiary Healthcare Facilities and Specialized Clinics: Particularly those with in-house pathology or microbiology departments that handle a higher volume and complexity of biological samples.

Installation Process For Biosafety Cabinets (Class Ii)

Ensuring the optimal performance and safety of your Class II Biosafety Cabinet (BSC) in Zimbabwe begins with a meticulous installation process. Our expert technicians will guide you through each stage, from initial site preparation to final calibration, guaranteeing your facility meets the highest standards for biological safety.

  • Site Preparation: Before delivery, a designated installation area must be prepared. This includes ensuring adequate space for the cabinet and its service connections, a stable and level floor, appropriate ventilation access (if required by the specific BSC model and local regulations), and access to a reliable power supply with surge protection. Consider the clearance required for future maintenance and filter changes. Your facility should also be free of dust and major construction activities during the installation period to prevent contamination.
  • Delivery and Unpacking: Upon arrival, our trained personnel will carefully transport the BSC to its designated location. The cabinet will be unpacked with utmost care to prevent any damage to its sensitive components and exterior. All packaging materials will be removed and disposed of responsibly.
  • Installation Steps:
    • Positioning: The BSC will be precisely positioned in the prepared location, ensuring it is level and stable.
    • Service Connections: Essential connections, including electrical power, will be made according to manufacturer specifications and local electrical codes in Zimbabwe. If the model requires external exhaust or is recirculating with HEPA filtered exhaust, these connections will be established.
    • Initial System Checks: Before power-up, a thorough visual inspection of all components and connections will be performed to identify any potential issues.
    • Power-Up and System Startup: The cabinet will be powered on, and initial system diagnostics will be run to confirm all internal fans, lights, and safety interlocks are functioning correctly.
    • Performance Verification: Basic operational parameters, such as airflow velocity and balance, will be checked using calibrated instruments.
  • Calibration and Certification Requirements:
  • Post-installation, a critical phase of calibration and initial certification takes place. This ensures your Class II BSC meets the rigorous performance standards required for your laboratory operations and complies with international biosafety guidelines applicable in Zimbabwe. This typically involves:
    • Airflow Velocity and Balance Testing: Precise measurements of both inflow and downflow air velocities are taken using specialized anemometers to confirm they fall within manufacturer-specified and relevant international standards (e.g., NSF/ANSI 49, EN 12469).
    • HEPA Filter Integrity Testing: A scan test will be conducted on the HEPA filters to detect any leaks or breaches, ensuring the integrity of the filtration system and the protection it offers.
    • UV Lamp Performance Check (if applicable): For models equipped with UV germicidal lamps, their output and functionality will be verified.
    • Alarms and Interlock Functionality: All safety alarms and interlocks (e.g., airflow failure alarms) will be tested to ensure they are operational and will alert users to any deviations from safe operating conditions.
    • Final Certification Report: Upon successful completion of all tests, a detailed certification report will be provided, documenting the performance of the BSC and confirming its compliance. This report is essential for regulatory compliance and internal quality assurance within your Zimbabwean facility.

How Much Is A Biosafety Cabinet (Class Ii) In Zimbabwe?

The investment in a Class II Biosafety Cabinet (BSC) in Zimbabwe can vary significantly, influenced by factors such as brand reputation, advanced features, size, and the supplier's service package. These essential pieces of laboratory equipment are crucial for protecting personnel, the environment, and the product, making their acquisition a vital consideration for any research, diagnostic, or healthcare facility.

For standard, reliable Class II Biosafety Cabinets, you can generally expect price ranges to fall between ZWL $30,000 and ZWL $150,000. This broad spectrum accounts for models offering fundamental protection with robust build quality, suitable for a wide array of common laboratory applications. More advanced models, equipped with enhanced HEPA filtration systems, real-time monitoring capabilities, energy-efficient designs, and specialized airflow patterns for specific applications like cell culture or IVF, can command higher prices. These premium units may range from ZWL $150,000 to upwards of ZWL $400,000 or more.

It is important to factor in potential additional costs that might not be immediately apparent. These can include:

  • Installation and commissioning fees
  • Ongoing maintenance and service contracts
  • Replacement filter costs
  • Training for laboratory personnel on proper operation and maintenance
  • Shipping and potential import duties if sourced internationally.

Affordable Biosafety Cabinets (Class Ii) Options

Understanding the budgetary constraints healthcare and research institutions in Zimbabwe face, we offer a range of cost-effective Biosafety Cabinet (Class II) solutions without compromising essential safety standards. These value-focused options are ideal for laboratories seeking reliable containment and protection while optimizing their investment.

  • Refurbished Units: Benefit from professionally inspected and serviced Class II Biosafety Cabinets that have undergone rigorous testing to ensure full operational functionality and safety compliance. These units provide a significant cost saving over new equipment.
  • Demo Models: Explore our selection of nearly-new demonstration models. These cabinets have been used for a limited time for product showcases and offer the latest features at a reduced price, providing excellent performance and value.
  • Entry-Level Systems: Our entry-level Class II Biosafety Cabinets are designed for essential biosafety applications. These systems deliver reliable containment and protection for routine laboratory work, offering a dependable and budget-friendly option for emerging or smaller research facilities.

Verified Biosafety Cabinets (Class Ii) Suppliers In Zimbabwe

Navigating the procurement of Class II Biosafety Cabinets for your laboratory in Zimbabwe requires trust and expertise. At Franance Health, we stand as your dedicated partner, ensuring you receive not only high-quality, certified equipment but also unparalleled local support. We understand the critical nature of biosafety and are committed to empowering your research and diagnostic operations with reliable and compliant solutions.

  • Direct OEM Partnerships: Franance Health maintains strong, direct relationships with leading Original Equipment Manufacturers (OEMs) of Class II Biosafety Cabinets. This ensures you receive genuine, factory-warranted units, directly from the source, eliminating intermediaries and guaranteeing authenticity and adherence to international safety standards.
  • Dedicated Local Engineering Team: Our investment in a skilled, local engineering team is a cornerstone of our service. These professionals are not only adept at installation and commissioning but are also available for ongoing maintenance, calibration, and essential repairs right here in Zimbabwe. This drastically reduces downtime and provides you with responsive, expert assistance when you need it most.
  • Comprehensive Warranty and Support: Every Class II Biosafety Cabinet purchased through Franance Health comes with a robust warranty. Beyond the initial warranty period, we offer comprehensive service contracts and readily available spare parts, ensuring the longevity and optimal performance of your equipment. Our commitment extends beyond the sale, providing continuous support for your biosafety needs.

Standard Configuration & Accessories

When you invest in a Class II Biosafety Cabinet for your facility in Zimbabwe, you're not just purchasing a protective enclosure; you're acquiring a comprehensive system designed for optimal performance and user safety. Our standard configuration ensures you have the core components necessary for immediate deployment and effective use. While specific models may offer variations, the following typically comes included:

  • Main biosafety cabinet unit (including frame, work surface, sash, and internal filtration system)
  • Pre-installed HEPA filters (supply and exhaust)
  • Integrated UV germicidal lamp with timer
  • Adjustable and inclinable front sash with safety interlock
  • Internal, easy-to-clean stainless steel work surface
  • Adjustable speed exhaust fan
  • Operator presence sensor (in some models)
  • Audible and visual alarms for airflow disruption and sash height
  • Power cord and basic user manual

Warranty & Maintenance Plans

We understand the critical role biosafety cabinets play in your laboratory's operations. To ensure uninterrupted performance and the highest level of safety, we offer comprehensive warranty and maintenance plans tailored to your needs in Zimbabwe. Our standard warranty covers manufacturing defects for a specified period, providing you with peace of mind. Beyond the initial warranty, we offer flexible Preventive Maintenance (PPM) plans. These plans are designed to keep your Class II biosafety cabinet operating at peak efficiency through regular inspections, calibration, and filter checks. Our certified technicians in Zimbabwe are equipped to perform all necessary maintenance tasks, minimizing downtime and extending the lifespan of your equipment.

Furthermore, we maintain a robust stock of genuine spare parts specifically for our range of biosafety cabinets, ensuring prompt replacement if any component requires servicing or repair. This proactive approach to maintenance and readily available parts significantly reduces the risk of unexpected breakdowns and safeguards your research and personnel.

  • Standard warranty covering manufacturing defects.
  • Customizable Preventive Maintenance (PPM) plans for regular servicing and calibration.
  • Certified technicians available locally in Zimbabwe.
  • Prompt availability of genuine spare parts for Class II biosafety cabinets.
In-Depth Guidance

Frequently Asked Questions

Background
Phase 02: Execution

Ready whenever you are

Let's discuss your Biosafety Cabinets (Class II) in Zimbabwe requirements in Zimbabwe.

Speak to Sales