Buy Oxygen Cylinder Regulator in Tanzania. Top suppliers, installation, and warranty from Franance Health. Get a quote today.

Contact Sales

Precise Pressure Control

Ensures accurate oxygen delivery to patients with adjustable pressure settings, vital for critical care in Tanzanian health facilities.

Variable Flow Rate

Offers a wide range of adjustable flow rates from 0 to 15 LPM, allowing for tailored oxygen therapy based on individual patient needs.

Universal Compatibility

Features standard CGA fittings for seamless integration with most oxygen cylinders and delivery devices used across Tanzania's healthcare network.

What Is An Oxygen Cylinder Regulator?

An oxygen cylinder regulator is a crucial medical device designed to interface with compressed oxygen cylinders. Its primary function is to safely and precisely reduce the high pressure within the cylinder to a usable and medically appropriate pressure and flow rate for patient administration. Without a regulator, the high-pressure oxygen escaping a cylinder would be hazardous and unmanageable for therapeutic use. It acts as a vital link, ensuring a controlled and consistent supply of oxygen to patients requiring respiratory support.

Clinical ApplicationRole of the Regulator
Hypoxemia (Low Blood Oxygen)Delivers supplemental oxygen to increase blood oxygen saturation levels.
Respiratory DistressAssists patients struggling to breathe by providing a continuous oxygen supply.
Post-Anesthesia RecoveryAids in the re-oxygenation of patients after surgical procedures.
Emergency Medical Services (EMS)Provides critical oxygen therapy during transport and on-site interventions.
Chronic Obstructive Pulmonary Disease (COPD)Manages symptoms and improves quality of life for individuals with chronic lung conditions.

Key Functions of an Oxygen Cylinder Regulator:

  • Pressure Reduction: Safely lowers cylinder pressure from hundreds of PSI to a manageable outlet pressure (typically 50 PSI).
  • Flow Control: Allows healthcare professionals to adjust and set the precise oxygen flow rate (measured in liters per minute, L/min) according to patient needs.
  • Pressure Monitoring: Often incorporates a gauge to display the remaining oxygen pressure within the cylinder, indicating when a refill or replacement is necessary.
  • Safety Valve: Includes a relief valve to prevent over-pressurization of the regulator and downstream equipment.

Who Needs Oxygen Cylinder Regulator In Tanzania?

In Tanzania, the demand for reliable oxygen cylinder regulators spans a wide spectrum of healthcare facilities, from tertiary teaching hospitals to smaller rural clinics. These essential devices are critical for the safe and effective delivery of medical-grade oxygen, ensuring patient well-being across diverse medical settings.

Facility TypePrimary Use Case for Regulators
Tertiary Teaching HospitalsHigh-volume use in ICUs, ERs, surgical theatres, and specialized units; critical for advanced patient care.
Regional & District HospitalsEssential for general patient care, post-operative recovery, respiratory distress management, and emergency interventions.
Rural Health Centers & DispensariesVital for managing acute respiratory conditions, post-natal care, and basic emergency oxygen therapy.
Private Hospitals & ClinicsEnsuring consistent oxygen supply for elective surgeries, diagnostic procedures, and various medical conditions.
Emergency Medical Services (EMS)Portable regulators are crucial for immediate oxygen administration during patient transport.

Key Healthcare Facilities and Departments Requiring Oxygen Cylinder Regulators:

  • Tertiary Teaching Hospitals (e.g., Muhimbili National Hospital, Bugando Medical Centre)
  • Regional Referral Hospitals
  • District Hospitals
  • Rural Health Centers and Dispensaries
  • Private Hospitals and Specialized Clinics
  • Emergency Medical Services (EMS)
  • Surgical Departments
  • Intensive Care Units (ICUs) and High Dependency Units (HDUs)
  • Emergency Rooms (ERs) / Accident & Emergency (A&E) Departments
  • Pediatric Wards and Neonatal Intensive Care Units (NICUs)
  • Pulmonology Departments
  • Anesthesiology Departments
  • Rehabilitation Centers
  • Field Hospitals and Mobile Clinics

Installation Process For Oxygen Cylinder Regulator In Tanzania

Ensuring the safe and effective operation of your oxygen therapy equipment begins with proper installation. Our Oxygen Cylinder Regulators are designed for straightforward setup, but adherence to these steps guarantees optimal performance and patient safety. We recommend that installation be performed by a qualified biomedical technician familiar with medical gas systems.

Site Preparation: Before delivery, ensure the designated area for the oxygen cylinder is well-ventilated, free from flammable materials, and easily accessible. The cylinder should be stored upright and secured to prevent tipping. All connecting tubing and accessories should be at room temperature and clean.

Delivery and Inspection: Upon delivery in Tanzania, carefully inspect the oxygen cylinder regulator for any visible signs of damage incurred during transit. Verify that all components are present as per your order and that the regulator is compatible with the type of oxygen cylinder you are using.

Installation Steps:

  • Ensure the oxygen cylinder valve is fully closed before attaching the regulator.
  • Align the regulator's inlet connection with the cylinder valve outlet. For most standard CGA 540 fittings used with oxygen cylinders, this is a simple direct connection.
  • Securely tighten the regulator to the cylinder valve using the provided T-handle or appropriate wrench. Do not overtighten.
  • Slowly open the cylinder valve a quarter turn to release a small amount of oxygen and check for any leaks around the connection. Listen for hissing sounds.
  • If no leaks are detected, fully open the cylinder valve.
  • Connect the oxygen delivery tubing (e.g., nasal cannula, mask) to the regulator's outlet port.

Calibration Requirements:

Our oxygen cylinder regulators are factory-calibrated for accurate flow rate delivery. However, regular checks and recalibration may be necessary to maintain accuracy, especially after prolonged periods of non-use or if the regulator has been dropped or damaged. It is recommended to perform a flow rate verification check at regular intervals as per your facility's medical equipment maintenance schedule, or at least annually, using a calibrated flow meter. This ensures that the prescribed oxygen flow rates are accurately delivered to the patient.

How Much Is An Oxygen Cylinder Regulator In Tanzania?

The cost of an oxygen cylinder regulator in Tanzania can vary significantly depending on whether you are purchasing a brand-new unit or a refurbished one, as well as the specific features and brand. For new, high-quality regulators designed for medical use, you can generally expect to invest in the range of TSh 150,000 to TSh 400,000. This price bracket often reflects the durability, precision, and safety features essential for reliable oxygen delivery in healthcare settings. Factors such as the presence of integrated flowmeters, pressure gauges, and specific connection types will influence the final price.

Refurbished oxygen cylinder regulators offer a more budget-friendly option for facilities or individuals in Tanzania looking to reduce costs. These units, which have been previously used and professionally restored to full working order, typically range from TSh 70,000 to TSh 200,000. While offering significant savings, it's crucial to ensure that refurbished regulators are sourced from reputable suppliers who can provide certification of their functionality and safety standards. Always inquire about any warranty or guarantee offered on refurbished equipment.

It is advisable to obtain quotes from multiple suppliers across Tanzania to compare prices and product specifications. Consider the total cost of ownership, including any potential maintenance or calibration needs, when making your decision.

ConditionEstimated Price Range (TSh)
New Regulator150,000 - 400,000
Refurbished Regulator70,000 - 200,000

Factors Affecting Price:

  • Brand and Manufacturer Reputation
  • Material Quality and Durability
  • Included Features (e.g., flowmeter, gauge, humidifier port)
  • New vs. Refurbished Condition
  • Supplier and Location within Tanzania
  • Warranty and After-Sales Support

Affordable Oxygen Cylinder Regulator Options

We understand that healthcare facilities in Tanzania often operate with budget constraints. That's why we offer a range of value-focused oxygen cylinder regulator options designed to provide reliable performance without compromising essential functionality. Whether you are a small clinic, a rural health post, or a large hospital looking to optimize expenditure, our cost-effective solutions ensure your patients receive the critical oxygen therapy they need.

Option TypeKey BenefitIdeal For
Refurbished RegulatorsSignificant Cost Savings, Proven ReliabilityBudget-conscious clinics, hospitals prioritizing value
Demo ModelsNear-new condition at a lower price, High-quality performanceFacilities with limited upfront capital, Clinics seeking reliable secondary units
Entry-Level SystemsMaximum Affordability, Essential FunctionalityRural health posts, Small clinics, Training facilities

Discover Our Budget-Conscious Solutions:

  • Refurbished Oxygen Regulators: Our expertly refurbished regulators undergo rigorous testing and recalibration to meet stringent safety and performance standards. These units offer significant cost savings while delivering dependable oxygen delivery.
  • Demo Models: Explore gently used demonstration units that have seen minimal use. These are an excellent way to acquire high-quality regulators at a reduced price point, perfect for facilities seeking reliable equipment with a smaller investment.
  • Entry-Level Systems: For organizations prioritizing fundamental functionality and affordability, our entry-level oxygen regulators provide essential features for safe and effective oxygen administration, making critical care accessible.

Verified Oxygen Cylinder Regulator Suppliers In Tanzania

When sourcing critical medical equipment like oxygen cylinder regulators in Tanzania, reliability and quality are paramount. At Franance Health, we distinguish ourselves by offering unparalleled assurance and support to healthcare providers. Our commitment to excellence ensures that you receive not just a product, but a complete solution designed to meet the rigorous demands of medical oxygen delivery.

Why partner with Franance Health for your oxygen cylinder regulator needs?

Our Distinct Advantages:

  • Exclusive OEM Partnerships: Franance Health maintains direct, authorized partnerships with leading Original Equipment Manufacturers (OEMs) globally. This direct line guarantees that every oxygen cylinder regulator we supply is genuine, of the highest quality, and adheres to international safety and performance standards. You can trust that you are receiving equipment from reputable manufacturers with a proven track record in the medical field.
  • Dedicated Local Engineering Team: We understand the unique challenges and operational environments within Tanzania. Our experienced local engineering team is readily available to provide expert installation, calibration, and ongoing technical support for all oxygen cylinder regulators. This localized expertise ensures seamless integration into your existing infrastructure and rapid resolution of any operational queries, minimizing downtime and maximizing efficiency.
  • Comprehensive Warranty and Support: Every oxygen cylinder regulator purchased from Franance Health is backed by a robust warranty. We stand firmly behind the quality and durability of our products. Beyond the warranty period, our commitment continues with accessible repair services and readily available spare parts, ensuring the long-term functionality and reliability of your essential medical equipment.

Standard Configuration & Accessories

When you purchase an Oxygen Cylinder Regulator for your facility in Tanzania, the standard configuration typically includes the essential components for safe and efficient oxygen delivery. While advanced medical setups might involve additional peripherals, the core package is designed for immediate functionality. Please note that specific inclusions can vary slightly between manufacturers and models, so we always recommend confirming with your sales representative.

ComponentDescriptionPurpose
Oxygen Cylinder RegulatorThe primary device that reduces high-pressure oxygen from the cylinder to a safe, usable pressure.Controls the pressure delivered to the patient or equipment.
Pressure GaugeA dial indicating the remaining pressure within the oxygen cylinder.Allows users to monitor oxygen supply levels and plan for refills.
FlowmeterA calibrated tube with a float or indicator that measures and controls the rate of oxygen delivery.Ensures the patient receives the prescribed oxygen flow rate (e.g., liters per minute).
Cylinder ConnectionThe fitting that securely attaches the regulator to the oxygen cylinder valve.Ensures a gas-tight seal for safe oxygen transfer.
User ManualComprehensive guide detailing setup, operation, maintenance, and safety precautions.Essential for proper and safe use of the equipment.

What's Typically Included:

  • Oxygen Cylinder Regulator unit
  • Pressure gauge (typically for cylinder pressure)
  • Flowmeter (calibrated for oxygen, with options for different flow rates)
  • Connecting nut and washer for standard oxygen cylinder valves (e.g., CGA 540 in many regions)
  • User Manual and Operating Instructions

Warranty & Maintenance Plans

We understand the critical role that reliable oxygen cylinder regulators play in healthcare delivery across Tanzania. To ensure your continued operational efficiency and patient safety, we offer robust warranty and comprehensive maintenance plans designed to meet the unique demands of the Tanzanian medical landscape. Our commitment extends beyond initial purchase, providing peace of mind through excellent post-sales support.

ServiceDescriptionBenefits for Tanzanian Healthcare Providers
Standard WarrantyCovers manufacturing defects for a specified period.Protection against unforeseen component failures during the initial ownership phase.
Preventive Maintenance (PPM)Scheduled inspections, cleaning, calibration, and part replacement.Maximizes regulator lifespan, ensures consistent performance, and reduces costly emergency repairs.
Genuine Spare PartsReadily available stock of authentic replacement parts.Guarantees optimal performance and safety of repaired units, avoiding compatibility issues and substandard repairs.

Key Features of Our Support:

  • Standard Warranty: All our oxygen cylinder regulators come with a [Insert Duration, e.g., 12-month] standard manufacturer's warranty covering defects in materials and workmanship.
  • Preventive Maintenance Programs (PPM): We offer tailored PPM packages to keep your regulators in optimal working condition. These proactive services include regular inspections, calibration, cleaning, and timely replacement of wear-and-tear parts, significantly reducing the risk of unexpected failures.
  • Spare Parts Availability: We maintain a dedicated stock of genuine and high-quality spare parts for all the oxygen cylinder regulator models we supply in Tanzania. This ensures prompt repair and minimizes downtime should any component require replacement.
In-Depth Guidance

Frequently Asked Questions

Background
Phase 02: Execution

Ready whenever you are