Background
Verified Service Provider in South Sudan

MRI RF Cage (Faraday Cage) Installation & Testing Service in South Sudan Engineering Excellence & Technical Support

MRI RF Cage (Faraday Cage) Installation & Testing Service High-standard technical execution following OEM protocols and local regulatory frameworks.

Talk To Sales

RF Interference Shielding

Expert installation and rigorous testing of MRI RF cages to ensure optimal shielding effectiveness, eliminating external electromagnetic interference and guaranteeing pristine image quality for diagnostics in South Sudan's challenging environments.

Compliance & Calibration

Adherence to international MRI RF cage performance standards and meticulous calibration services, providing South Sudanese healthcare facilities with certified, reliable shielding solutions that meet global benchmarks for patient safety and diagnostic accuracy.

Specialized Installation & Maintenance

Provision of highly specialized installation expertise and ongoing maintenance support for MRI RF cages, specifically tailored for the unique logistical and environmental conditions present in South Sudan, ensuring long-term operational integrity and minimal downtime.

What Is Mri Rf Cage (Faraday Cage) Installation & Testing Service In South Sudan?

An MRI RF cage, commonly referred to as a Faraday cage in this context, is a specialized metallic enclosure designed to shield the Magnetic Resonance Imaging (MRI) scanner from external radiofrequency (RF) interference. This shielding is critical for acquiring high-quality diagnostic images, as unwanted RF signals can degrade image resolution, introduce artifacts, and compromise diagnostic accuracy. The installation and testing of such a system in South Sudan involves a multi-faceted process to ensure the cage meets stringent electromagnetic compatibility (EMC) standards.

Installation entails the construction of a highly conductive enclosure, typically using copper or aluminum panels, mesh, or conductive fabric. This structure is meticulously assembled to form a sealed environment, preventing external RF waves from penetrating. Key aspects include:

  • Structural Integrity: Ensuring the cage is robust and can withstand the environmental conditions in South Sudan.
  • RF Shielding Integrity: Verifying the complete absence of gaps, holes, or conductivity breaks in the enclosure that could act as entry points for RF noise. This includes proper sealing of all seams, doors, windows, and penetrations (for ventilation, power, and data).
  • Waveguide Filters: Integrating specialized filters on all apertures (e.g., ventilation ducts, electrical conduits, fiber optic cables) to allow necessary airflow and signal transmission while blocking RF energy. This is a critical step often overlooked.
  • Grounding and Bonding: Establishing a comprehensive grounding system to dissipate any induced RF currents and ensure the cage's electrical potential is consistent with the environment.
  • Door and Window Design: Implementing RF-shielded doors with multi-point locking mechanisms and specialized viewing windows (often using fine RF-transparent mesh) to maintain shielding integrity while allowing access and visibility.

Testing is a rigorous process conducted post-installation to quantitatively verify the RF shielding effectiveness (RSE) of the cage across a broad spectrum of relevant frequencies. This typically involves:

  • Pre-Installation Assessment: Sometimes, a baseline RF noise assessment of the intended installation site is performed.
  • RF Shielding Effectiveness (RSE) Measurement: Using calibrated RF signal generators and sensitive receivers, the RSE is measured at various points within the cage, both with and without the MRI scanner operational. Standard test procedures (e.g., IEEE 299, MIL-STD-285) are often referenced. Measurements are typically taken from 1 MHz up to several GHz to cover the operational frequencies of the MRI scanner and potential external interference sources.
  • Penetration Point Testing: Specific testing of all waveguides, filters, and penetrations to ensure they meet attenuation requirements.
  • Door Seal Integrity Testing: Verifying the RF seal of the door and any associated interlocks.
  • Acoustic and Ventilation Testing: While not directly RF related, these are often integrated into the commissioning process to ensure the MRI environment is suitable for patient comfort and scanner operation.

Who Needs It:

  • Healthcare Facilities: Hospitals, specialized diagnostic imaging centers, and clinics in South Sudan operating or planning to operate MRI scanners.
  • Medical Equipment Manufacturers and Installers: Companies involved in the supply and setup of MRI equipment who are responsible for ensuring proper installation and functionality.
  • Government Health Ministries and Agencies: Overseeing the standards and infrastructure for medical imaging services.
  • Research Institutions: If any advanced medical research requiring MRI is conducted.

Typical Use Cases:

The primary use case is the establishment of a functional and reliable MRI diagnostic imaging service. This enables the diagnosis of a wide range of medical conditions, including:

  • Neurological disorders (e.g., tumors, strokes, multiple sclerosis)
  • Musculoskeletal injuries (e.g., ligament tears, joint damage)
  • Cardiovascular diseases
  • Abdominal and pelvic pathologies
  • Oncological staging and monitoring
  • Pre-surgical planning

Effective RF shielding is a prerequisite for performing any of these diagnostic procedures accurately and safely using MRI technology.

AspectDescription in South Sudan ContextCriticality
Installation ComplexityRequires skilled technicians experienced in RF shielding construction, potentially facing logistical challenges for materials and specialized equipment.High - Directly impacts shielding performance.
Environmental ConsiderationsMust account for local climate (humidity, temperature) and potential for dust ingress, which can affect materials and sealing.Medium - Affects long-term durability and performance.
Power Quality and StabilityPotential for unstable power grids necessitates robust grounding and bonding for personnel and equipment safety, and to minimize noise coupling.High - Affects safety and image quality.
Access to ExpertiseMay require international consultation or training due to limited local specialists in advanced RF shielding.High - Essential for proper design and execution.
Maintenance and SupportEstablishing protocols for ongoing maintenance and rapid response to any potential shielding breaches is crucial for sustained operation.High - Ensures continued reliability.
Regulatory ComplianceAdherence to international medical imaging standards is paramount, even in regions with developing local regulatory frameworks for such technologies.High - Ensures diagnostic accuracy and patient safety.

Key Components and Processes of MRI RF Cage Installation & Testing in South Sudan

  • Installation Phases:
    • Site Preparation and Structural Assembly
    • RF Shielding Panel/Mesh Installation
    • Door and Window Integration
    • RF Filter Installation (Waveguides)
    • Electrical and Data Penetration Shielding
    • Comprehensive Grounding and Bonding
  • Testing and Verification Phases:
    • Pre-Installation RF Environment Assessment (Optional)
    • RF Shielding Effectiveness (RSE) Measurement
    • Penetration Point Attenuation Testing
    • Door Seal and Interlock Verification
    • Compliance with International Standards (e.g., IEEE 299)
    • Documentation and Certification

Who Needs Mri Rf Cage (Faraday Cage) Installation & Testing Service In South Sudan?

MRI RF Cage (Faraday Cage) installation and testing services are crucial for any facility in South Sudan that operates or plans to operate an MRI scanner. These cages are essential for protecting the sensitive MRI equipment from external radiofrequency (RF) interference, which can degrade image quality and render scans unusable. Furthermore, they also prevent the MRI scanner's own RF emissions from interfering with other electronic equipment, ensuring a safe and functional healthcare environment.

Target Customer TypeSpecific Departments/Users within the FacilityReason for Needing RF Cage Services
Hospitals and Medical CentersRadiology Department, Imaging Center, Medical Physics DepartmentEnsuring high-quality MRI scans, protecting patient data, preventing equipment malfunction, compliance with international standards.
Diagnostic Imaging ClinicsImaging Technologists, Radiologists, Clinic AdministratorsMaintaining the integrity of diagnostic images for accurate diagnosis, attracting patients seeking high-end imaging, optimizing scanner performance.
Government Healthcare FacilitiesMinistry of Health representatives, Hospital Administration, Radiology StaffProviding reliable and accurate diagnostic imaging for the public, ensuring efficient use of public health resources, upgrading medical infrastructure.
NGO Healthcare ProvidersMedical Directors, Project Managers, Imaging Specialists, Field Hospital StaffDelivering essential diagnostic services in challenging environments, ensuring continuity of care, supporting humanitarian efforts with advanced medical technology.
Research and Academic Medical InstitutionsResearch Scientists, Medical Researchers, MRI Physicists, Imaging TechniciansConducting precise and reproducible research, obtaining reliable data for scientific publications, training future medical professionals on advanced imaging techniques.

Target Customers and Departments for MRI RF Cage Installation & Testing in South Sudan:

  • Hospitals and Medical Centers: The primary clients will be existing and newly established hospitals and medical centers that have or intend to acquire MRI machines.
  • Diagnostic Imaging Clinics: Specialized clinics focused on providing advanced diagnostic imaging services.
  • Government Healthcare Facilities: Public hospitals and clinics managed by the South Sudanese Ministry of Health.
  • Non-Governmental Organization (NGO) Healthcare Providers: International and local NGOs operating medical facilities and providing healthcare services in the region.
  • Research and Academic Medical Institutions: Any institutions involved in medical research or training that utilize MRI technology.

Mri Rf Cage (Faraday Cage) Installation & Testing Service Process In South Sudan

This document outlines the comprehensive workflow for MRI Radio Frequency (RF) Cage (Faraday Cage) installation and testing services in South Sudan, from the initial client inquiry to the final handover. The process is designed to ensure adherence to international standards, minimize disruption, and provide a robust, reliable RF shielding solution for MRI suites.

PhaseKey ActivitiesDescriptionDeliverables/OutcomesTypical Duration
  1. Inquiry & Consultation
Initial Contact, Needs Assessment, Preliminary DiscussionClient expresses interest in an MRI RF cage. Our team engages in an initial discussion to understand their requirements, facility type, existing infrastructure, and any specific challenges in South Sudan (e.g., logistics, local regulations).Understanding of client needs, preliminary feasibility assessment, establishment of communication channel.1-3 Business Days
  1. Site Assessment & Design
Detailed Site Survey, RF Shielding Design, Technical Specification DevelopmentUpon agreement for a site assessment, our engineers visit the facility in South Sudan. They conduct detailed measurements of the MRI room dimensions, structural integrity, power and data cabling pathways, and environmental factors. Based on this, a customized RF shielding design (cage type, materials, door specifications, ventilation, power/data filtering) is developed adhering to international MRI RF shielding standards (e.g., IEC 60601-2-33).Detailed site survey report, comprehensive RF cage design schematics, material specifications, Bill of Quantities (BOQ).5-10 Business Days (dependent on site accessibility and complexity)
  1. Quotation & Agreement
Cost Estimation, Proposal Submission, Contract Negotiation & SigningA detailed quotation is prepared based on the BOQ and service scope. This is submitted to the client along with a comprehensive proposal outlining the project timeline, responsibilities, and terms. Upon negotiation and agreement, a formal contract is signed.Formal quotation and proposal, signed service agreement/contract.3-7 Business Days
  1. Procurement & Logistics
Material Sourcing, Manufacturing, Transportation to South SudanAll required materials (shielding panels, RF-sealed doors, filters, waveguides, etc.) are procured from reputable suppliers. Materials are manufactured as per specifications and then carefully packaged for transportation to the designated site in South Sudan, considering all import/export regulations and logistical challenges.Procured and manufactured materials, shipping documentation, cleared import/customs (where applicable).4-8 Weeks (highly variable based on material availability and shipping logistics)
  1. Installation
Site Preparation, Cage Assembly, Integration of RF-Sealed ComponentsOur certified installation team arrives at the South Sudan site. They prepare the MRI room, ensuring a clean and secure work environment. The RF cage is meticulously assembled according to the design specifications. This includes installing shielding panels, ensuring seamless joints, fitting RF-sealed doors, windows, ventilation systems, and integrating necessary RF filters for power and data lines.Fully installed RF cage structure, integrated RF-sealed components.1-3 Weeks (depending on cage size and complexity)
  1. Testing & Certification
RF Attenuation Testing, Performance Verification, Final ReportPost-installation, rigorous testing is conducted to ensure the RF cage meets or exceeds the required attenuation levels across the specified frequency spectrum. This typically involves specialized RF test equipment (e.g., signal generators, spectrum analyzers, loop antennas). A detailed certification report is generated, confirming compliance with relevant standards.RF attenuation test results, performance verification report, RF cage certification document.2-5 Business Days
  1. Handover & Training
Final Walkthrough, Documentation Review, User TrainingA final walkthrough of the installed RF cage is conducted with the client. All project documentation, including the design, test reports, and maintenance guidelines, is handed over. Training is provided to the facility's technical staff on the proper operation, maintenance, and any potential troubleshooting of the RF cage system.Completed project documentation, trained facility personnel.1-2 Business Days
  1. Post-Installation Support
Warranty, Maintenance Recommendations, Ongoing AssistanceWe provide a warranty period for the installed RF cage. Recommendations for routine maintenance are provided to ensure long-term performance. We also offer ongoing technical support and assistance for any future needs or queries.Warranty coverage, maintenance schedule, accessible technical support.Ongoing

MRI RF Cage Installation & Testing Service Process in South Sudan: Workflow

  • Phase 1: Inquiry & Consultation
  • Phase 2: Site Assessment & Design
  • Phase 3: Quotation & Agreement
  • Phase 4: Procurement & Logistics
  • Phase 5: Installation
  • Phase 6: Testing & Certification
  • Phase 7: Handover & Training
  • Phase 8: Post-Installation Support

Mri Rf Cage (Faraday Cage) Installation & Testing Service Cost In South Sudan

Providing an MRI RF cage (Faraday cage) installation and testing service in South Sudan involves a complex set of factors that influence the overall cost. These cages are critical for ensuring the integrity of MRI scans by blocking external radio frequency interference. The pricing is highly variable due to the specific site conditions, the size and specifications of the MRI machine, the required performance standards of the cage, and the logistics involved in a country like South Sudan. Local currency (South Sudanese Pound - SSP) pricing will be influenced by import costs, labor availability, and the expertise required for such specialized work.

Service ComponentEstimated Range (SSP)Notes
RF Cage Materials & Fabrication (per sqm)1,500,000 - 5,000,000+Highly dependent on material type, complexity, and shielding performance required. Prices are estimates and can fluctuate significantly.
Site Preparation & Structural Modifications2,000,000 - 10,000,000+Varies greatly based on existing infrastructure and the scope of work needed.
Installation Labor (Local & International)3,000,000 - 15,000,000+Includes skilled technicians. International specialist costs can significantly increase this range.
RF Testing & Certification1,000,000 - 4,000,000+Covers specialized equipment rental and expert analysis.
Logistics, Shipping & Import Duties1,000,000 - 6,000,000+Subject to material volume, origin, and South Sudanese import regulations.
Project Management & Consultancy500,000 - 3,000,000+Professional oversight and technical advisory services.
Total Estimated Project Cost (Small to Medium MRI)7,500,000 - 43,000,000+ SSPThis is a very broad estimate. Exact quotes require detailed site surveys and specification analysis.
Total Estimated Project Cost (Large/High-Field MRI)15,000,000 - 70,000,000+ SSPLarger machines and higher performance requirements will push costs towards the higher end.

Key Pricing Factors for MRI RF Cage Installation & Testing in South Sudan

  • Cage Design and Materials: The complexity of the design, the type of shielding materials (e.g., copper, aluminum, perforated metal), and the required attenuation levels significantly impact material costs. Custom designs for specific MRI models are more expensive than standard ones.
  • MRI Machine Specifications: The size and magnetic field strength of the MRI scanner dictate the dimensions and performance requirements of the RF cage. Larger or higher-field machines may necessitate larger and more robust cages.
  • Site Preparation: The existing building structure might require modifications to accommodate the RF cage. This could include structural reinforcements, electrical system upgrades, and modifications to ventilation and cooling systems. The extent of these modifications directly affects labor and material costs.
  • Installation Labor: Skilled technicians with specialized experience in RF shielding installation are required. The availability and cost of such expertise in South Sudan can be a significant factor. This may involve bringing in international specialists, which incurs travel, accommodation, and per diem expenses.
  • Testing and Certification: Rigorous testing is essential to ensure the RF cage meets industry standards (e.g., IEC 60601-2-33). This involves specialized equipment and trained personnel to measure RF leakage. The cost of testing and obtaining certification will be a separate component.
  • Logistics and Import Duties: Transporting specialized materials and equipment to South Sudan can be costly due to infrastructure limitations and potential import duties and taxes. This adds to the overall project expense.
  • Project Management and Consultancy: Professional project management is crucial for coordinating the installation process. Consultancy fees for design review, site assessment, and project oversight are also factored in.
  • Timeline and Urgency: Expedited projects may incur additional costs for overtime labor or accelerated material procurement.
  • Warranty and Maintenance: While not strictly installation cost, some providers may offer post-installation warranty and maintenance packages, which can influence the initial quote.

Affordable Mri Rf Cage (Faraday Cage) Installation & Testing Service Options

Installing a functional and effective MRI Radio Frequency (RF) cage, also known as a Faraday cage, is crucial for acquiring high-quality MRI images. This shielding prevents external RF noise from interfering with the sensitive signals generated by the MRI scanner. While essential, the cost of professional installation and testing can be a significant investment. This guide outlines affordable installation and testing service options, explores value bundles, and provides cost-saving strategies to help facilities manage their budgets without compromising on performance.

Service Bundle OptionDescriptionPotential Cost Savings StrategyTypical Inclusions
Basic Installation & CertificationStandard RF cage construction and essential performance testing to meet fundamental requirements.Opting for simpler cage designs and materials if performance needs allow. Scheduling during off-peak installation periods.RF cage construction, RF shielding integrity testing, basic RF signal attenuation measurements, certification documentation.
Comprehensive Installation & Advanced TestingFull-scope RF cage installation including advanced features and thorough testing to ensure optimal performance and compliance.Bundling installation, testing, and initial shielding maintenance into one contract. Negotiating bulk discounts for materials.RF cage construction, detailed RF attenuation profiling, electromagnetic interference (EMI) troubleshooting, comprehensive certification report, initial shielding integrity check.
Refurbishment & Re-CertificationUpdating or repairing an existing RF cage to meet current standards and re-certifying its performance.Performing a thorough assessment of the existing cage to identify only necessary repairs, avoiding unnecessary upgrades. Combining re-certification with scheduled maintenance.Assessment of existing RF cage, minor repairs or upgrades, re-testing of RF shielding integrity, updated certification.
Installation, Testing & Long-Term Maintenance SLAA complete package including initial installation, thorough testing, and an ongoing service agreement for regular maintenance and re-testing.Securing a multi-year SLA can often result in preferential pricing and priority service. Proactive maintenance can prevent costly emergency repairs.All services from 'Comprehensive Installation & Advanced Testing' plus scheduled annual or bi-annual RF shielding checks, priority service response for issues, and discounted rates for future re-certifications.

Key Considerations for Affordable MRI RF Cage Installation & Testing:

  • Scope of Work: Clearly define whether you need a new RF cage installation, a refurbishment of an existing cage, or just testing and certification. Bundling services can often lead to discounts.
  • Cage Type and Materials: The complexity of the cage design and the materials used (e.g., copper, aluminum, steel mesh) will impact costs. Discuss options with your provider.
  • Existing Infrastructure: Leverage existing building structures or power infrastructure where possible to reduce new construction or wiring costs.
  • Testing & Certification Requirements: Understand the specific regulatory or manufacturer-required testing protocols (e.g., FCC, IEC standards) to ensure you're not overpaying for unnecessary certifications.
  • Provider Experience & Reputation: While seeking affordability, don't compromise on expertise. Experienced providers are more likely to complete the job efficiently and correctly, avoiding costly rework.
  • Service Level Agreements (SLAs): Consider long-term SLAs for ongoing maintenance and re-testing. These can sometimes offer better value than ad-hoc services.

Verified Providers In South Sudan

Finding reliable and accredited healthcare providers is paramount in any region, and South Sudan is no exception. "Verified Providers in South Sudan: Franance Health Credentials and Why They Represent the Best Choice" delves into the crucial role of verified medical services and highlights Franance Health as a leading example of excellence. In a landscape where quality and trustworthiness are essential, understanding the credentials and commitment of healthcare organizations is key for individuals seeking optimal health outcomes. This document aims to illuminate why Franance Health stands out.

Credential/AspectFranance Health's CommitmentBenefit to Patients
International AccreditationActively seeks and maintains accreditations from recognized global health organizations (e.g., JCI, ISO standards where applicable).Ensures adherence to world-class healthcare practices, safety protocols, and quality management systems.
Medical Staff QualificationsEmploys licensed and board-certified physicians, specialists, and nurses with proven track records and ongoing training.Guarantees that patients receive care from competent and up-to-date medical professionals.
Infrastructure and TechnologyInvests in advanced diagnostic and treatment equipment, ensuring functional and well-equipped facilities.Facilitates accurate diagnoses, efficient treatment, and a comfortable patient experience.
Patient Safety ProtocolsImplements robust patient safety measures, including infection control, medication management, and fall prevention strategies.Minimizes risks and ensures a safe environment for all patients.
Ethical StandardsAdheres to a strict code of medical ethics, emphasizing patient confidentiality, informed consent, and equitable treatment.Fosters trust and provides patients with the assurance that their rights and well-being are respected.
Community EngagementParticipates in public health programs, health education, and outreach initiatives within South Sudan.Contributes to the overall health improvement of the community and provides accessible health information.

Why Franance Health is the Best Choice for Verified Providers in South Sudan:

  • Rigorous Accreditation Standards: Franance Health adheres to the highest international and national accreditation standards, ensuring a baseline of quality care.
  • Experienced and Certified Medical Professionals: Their team comprises highly qualified doctors, nurses, and specialists with verifiable certifications and a commitment to continuous professional development.
  • State-of-the-Art Facilities and Equipment: Investment in modern medical technology and well-maintained facilities guarantees accurate diagnoses and effective treatments.
  • Patient-Centric Approach: Franance Health prioritizes patient well-being, offering compassionate care, clear communication, and personalized treatment plans.
  • Commitment to Ethical Practices: Upholding the strictest ethical guidelines in healthcare delivery builds trust and ensures patient safety.
  • Community Health Focus: Beyond individual care, Franance Health actively participates in and supports community health initiatives, demonstrating a holistic dedication to public well-being.
  • Transparency and Accountability: They maintain transparent operational procedures and are accountable for the services they provide, offering peace of mind to patients.
  • Accessibility and Affordability: Striving to make quality healthcare accessible, Franance Health works to offer services that are as affordable as possible without compromising quality.

Scope Of Work For Mri Rf Cage (Faraday Cage) Installation & Testing Service

This Scope of Work (SOW) outlines the requirements for the installation and testing of an MRI Radiofrequency (RF) Cage, also known as a Faraday Cage. The primary objective is to ensure the RF cage effectively shields the MRI scanner from external RF interference and prevents RF leakage from within the cage, thereby guaranteeing optimal image quality and patient safety. This SOW covers all necessary activities from site preparation and material procurement to final testing and handover.

PhaseActivity DescriptionTechnical DeliverablesStandard Specifications
  1. Planning & Design Review
Review of provided RF cage design drawings, specifications, and site layout. Confirmation of compliance with MRI manufacturer requirements and local building codes. Site survey to identify any potential challenges or modifications needed.Approved Design Drawings & Specifications, Site Survey Report.MRI Manufacturer's RF shielding requirements, relevant building codes (e.g., IEC 60372, ASTM F3052), project-specific RF attenuation targets (e.g., >100 dB @ specific frequencies).
  1. Site Preparation
Preparation of the MRI room to accommodate RF cage installation. This includes but is not limited to: temporary power installation, access for materials, dust control, and basic structural readiness. Installation of any required structural reinforcements or modifications as per design.Ready for RF Cage Installation.As per approved design drawings and site survey report. Ensuring structural integrity and clear access.
  1. RF Cage Fabrication & Installation
Procurement of all materials (e.g., copper or aluminum sheeting, conductive gaskets, RF-tight doors, RF-tight windows, filtered power/data conduits). Fabrication and precise installation of the RF cage structure, ensuring all seams are properly sealed for RF tightness. Installation of RF-tight doors, windows, ventilation systems, and penetrations for power, data, and medical gases.Installed RF Cage Structure, RF-tight Doors, Windows, Ventilation.High-quality, non-corrosive materials. Precise construction with overlap and sealing of all joints. Door and window frames designed for minimal RF leakage. Filtered penetrations to maintain shielding effectiveness.
  1. Electrical & Data Penetrations
Installation of RF-filtered power outlets, data ports, and other necessary electrical penetrations. Ensuring all filters are correctly rated and installed to prevent RF leakage. Connection of filtered systems to the main power and data infrastructure.RF-Filtered Electrical & Data Ports, Connected Systems.RF-tight conduit and filter installation. Filters rated for required attenuation and frequency range. Proper grounding of all components.
  1. Grounding System Installation
Installation of a comprehensive and effective RF grounding system for the entire cage structure and all internal metallic components. Ensuring low impedance paths to earth.Installed RF Grounding System.Low impedance grounding connections. Compliance with electrical grounding standards. Verification of grounding effectiveness.
  1. RF Shielding Effectiveness Testing
Conduct comprehensive RF shielding effectiveness testing of the completed cage. This includes measuring attenuation levels across the specified frequency range using calibrated RF test equipment. Testing at multiple points within the cage and at all penetrations.RF Shielding Effectiveness Test Report.Testing conducted according to recognized standards (e.g., IEEE 299, MIL-STD-285). Specified attenuation levels met or exceeded across the relevant frequency spectrum. Detailed measurement data and analysis.
  1. System Integration & Verification
Verification of seamless integration of the RF cage with the MRI system. This may involve functional tests of the MRI scanner with the RF cage in place to ensure no performance degradation due to shielding. Testing of RF-tight doors, ventilation, and other integrated systems.System Integration & Verification Report.No measurable impact on MRI image quality or system performance. All integrated systems functioning as designed.
  1. Final Inspection & Handover
Final visual inspection of the entire installation. Review of all test reports and documentation. Handover of the completed RF cage to the client, including all warranties and operational manuals.Certified RF Cage, As-Built Drawings, Test Reports, Warranties, O&M Manuals.Compliance with all contractually agreed-upon specifications and deliverables. All required documentation provided in an organized manner.

Key Objectives of the MRI RF Cage Installation & Testing Service

  • To achieve specified RF shielding effectiveness across the relevant frequency spectrum (e.g., 1-400 MHz).
  • To ensure seamless integration with the MRI system's operation and performance.
  • To prevent RF interference from external sources impacting MRI scans.
  • To contain RF emissions generated by the MRI scanner, protecting adjacent areas.
  • To meet all relevant building codes, safety regulations, and MRI manufacturer specifications.
  • To deliver a fully functional, certified, and tested RF cage ready for MRI system commissioning.

Service Level Agreement For Mri Rf Cage (Faraday Cage) Installation & Testing Service

This Service Level Agreement (SLA) outlines the terms and conditions for the MRI RF Cage (Faraday Cage) Installation & Testing Service provided by [Your Company Name] to [Client Name]. It defines the expected response times, resolution targets, and uptime guarantees to ensure optimal performance and reliability of the RF cage.

This SLA is an integral part of the contract for the MRI RF Cage Installation & Testing Service.

Service TypeSeverity LevelResponse Time TargetResolution Time TargetUptime Guarantee
Installation of New RF CageN/AAs per Project ScheduleAs per Project ScheduleN/A (Post-installation acceptance)
RF Cage Testing & CertificationCritical (Major performance degradation impacting MRI operation)2 Business Hours8 Business Hours (for initial diagnosis/work plan)N/A (Testing is a point-in-time event)
RF Cage Testing & CertificationHigh (Minor performance degradation impacting imaging quality)4 Business Hours24 Business Hours (for initial diagnosis/work plan)N/A (Testing is a point-in-time event)
RF Cage Testing & CertificationMedium (Minor deviations from baseline, no immediate impact on imaging)8 Business Hours72 Business Hours (for initial diagnosis/work plan)N/A (Testing is a point-in-time event)
Troubleshooting & RepairCritical (Complete RF shielding failure, MRI unusable)1 Business Hour4 Business Hours (for initial diagnosis and commencement of repair)99.5% (measured monthly, excluding scheduled maintenance)
Troubleshooting & RepairHigh (Significant RF interference impacting image quality and/or MRI operation)2 Business Hours8 Business Hours (for initial diagnosis and commencement of repair)99.5% (measured monthly, excluding scheduled maintenance)
Troubleshooting & RepairMedium (Minor RF leakage, potential for slight image artifacting)4 Business Hours24 Business Hours (for initial diagnosis and commencement of repair)99.8% (measured monthly, excluding scheduled maintenance)
Troubleshooting & RepairLow (Cosmetic issues, non-performance related)8 Business Hours72 Business Hours (for initial diagnosis and commencement of repair)99.8% (measured monthly, excluding scheduled maintenance)

Scope of Service

  • Installation of new MRI RF cages.
  • Testing and certification of existing MRI RF cages.
  • Troubleshooting and repair of RF cage performance issues.
  • Preventative maintenance of RF cage components (as per separate agreement if applicable).
In-Depth Guidance

Frequently Asked Questions

Background
Phase 02: Execution

Ready when you are

Let's scope your MRI RF Cage (Faraday Cage) Installation & Testing Service in South Sudan project in South Sudan.

Speak to Sales