Background
Verified Supplier in Nigeria

Oxygen Cylinder Regulator in Nigeria Leading Oxygen Cylinder Regulator Supplier

Buy Oxygen Cylinder Regulator in Nigeria. Top suppliers, installation, and warranty from Franance Health. Get a quote today.

Contact Sales

Accurate Pressure Control

Ensures precise oxygen delivery for critical patient care and industrial applications across Nigeria.

Robust & Reliable

Built to withstand harsh Nigerian environmental conditions, guaranteeing consistent performance.

Enhanced Safety Features

Equipped with safety valves to prevent over-pressurization, protecting users and equipment nationwide.

What Is An Oxygen Cylinder Regulator?

In Nigeria's critical healthcare sector, the Oxygen Cylinder Regulator is an indispensable medical device that ensures the safe and precise delivery of medical-grade oxygen from a compressed gas cylinder to a patient. It acts as a crucial intermediary, performing two primary functions: regulating the high pressure within the cylinder to a safe, usable level, and controlling the flow rate of oxygen to the patient. This sophisticated component is essential for maintaining therapeutic oxygen levels in various clinical settings, from emergency rooms and intensive care units to home-based respiratory care. Proper regulation is paramount for patient safety, preventing oxygen toxicity from excessive flow or insufficient oxygen therapy due to inadequate delivery.

Clinical ApplicationPurpose of Regulator
Respiratory Distress (e.g., Pneumonia, Asthma Exacerbations)Provides supplemental oxygen to improve blood oxygen saturation and ease breathing.
Chronic Obstructive Pulmonary Disease (COPD)Manages hypoxemia (low blood oxygen) for patients with long-term lung conditions.
Post-Surgical RecoveryAids in oxygenation and recovery for patients who have undergone surgical procedures.
Emergency MedicineRapidly delivers oxygen to stabilize patients experiencing acute medical emergencies like cardiac arrest or trauma.

Key Functions and Components:

  • Pressure Reduction: Decreases the high internal pressure of the oxygen cylinder (often up to 2200 psi) to a safe and manageable working pressure.
  • Flow Control: Allows healthcare professionals to precisely adjust and monitor the oxygen flow rate in litres per minute (LPM) according to patient needs.
  • Safety Features: Incorporates safety mechanisms like pressure relief valves to prevent over-pressurization and ensures secure connection to the oxygen cylinder.

Who Needs Oxygen Cylinder Regulator In Nigeria?

In Nigeria, a reliable oxygen cylinder regulator is an indispensable piece of equipment across a wide spectrum of healthcare facilities. From large tertiary institutions to remote health posts, the ability to safely and precisely control the flow of medical oxygen from a cylinder is critical for patient care. This vital device ensures that patients receive the correct oxygen dosage, preventing both under- and over-administration, which can have serious consequences. Healthcare providers in all settings, from bustling urban centers to underserved rural communities, rely on these regulators to manage a range of respiratory conditions and during various medical procedures.

Key Facility Types and Departments Requiring Oxygen Cylinder Regulators:

  • Teaching Hospitals & Tertiary Care Centers
  • General Hospitals & District Hospitals
  • Specialty Hospitals (e.g., Cardiac, Pulmonary, Pediatric)
  • Private Clinics & Diagnostic Centers
  • Maternity Homes & Birthing Centers
  • Ambulance Services & Emergency Medical Technicians
  • Remote Health Posts & Community Health Centers
  • Outpatient Departments (OPD)
  • Emergency Rooms (ER) / Accident & Emergency (A&E)
  • Intensive Care Units (ICU) & High Dependency Units (HDU)
  • Surgical & Operating Theatres
  • Anesthesia Departments
  • Respiratory Therapy Departments
  • Pediatric Wards & Neonatal Intensive Care Units (NICU)
  • Geriatric Care Facilities

Installation Process For Oxygen Cylinder Regulator

Ensuring the correct installation of your oxygen cylinder regulator is paramount for patient safety and equipment longevity. We outline a comprehensive process tailored for the Nigerian medical landscape, from initial site preparation to final calibration.

Site Preparation:

Before delivery, designated installation areas should be clean, well-ventilated, and free from combustible materials. Ensure adequate lighting and accessibility for safe handling of the cylinder and regulator. Verify that the area can support the weight of a full oxygen cylinder. Clear any potential obstructions around the cylinder storage location.

Delivery And Initial Inspection:

Upon delivery, our trained technicians will carefully transport the regulator and any associated accessories to the prepared site. A thorough visual inspection will be conducted to confirm the regulator is free from any damage sustained during transit. All components will be accounted for against the delivery manifest.

Installation Steps:

  • Cylinder Preparation: Ensure the oxygen cylinder valve is clean and free from debris. Slightly open and immediately close the cylinder valve (cracking) to purge any dust or impurities from the valve outlet.
  • Regulator Attachment: Align the regulator's inlet connection with the cylinder valve. Hand-tighten the connecting nut securely. For high-pressure connections, use a correct-sized spanner for a final snug fit, avoiding over-tightening.
  • Leak Check: Slowly open the cylinder valve. Listen for any hissing sounds indicating leaks. Apply a leak-detection solution (soap and water) to the connection point; bubbles will confirm a leak. If a leak is detected, immediately close the cylinder valve, disconnect the regulator, and re-attempt the installation or seek technical assistance.
  • Flow Setting: Once a secure, leak-free connection is established, adjust the regulator to the prescribed flow rate using the control knob or dial, referencing the patient's prescription.

Calibration Requirements:

While most modern oxygen cylinder regulators are factory-calibrated and do not require field calibration for basic function, regular functional checks are essential. Our technicians will perform post-installation checks to verify accurate pressure reduction and flow delivery according to specifications. It is recommended to have the regulator serviced and its accuracy re-verified by a qualified technician at least annually, or more frequently in high-usage environments, to ensure continued precision and patient safety.

Key ChecksFrequency
Visual Inspection for DamageUpon Delivery, Pre-use
Leak DetectionImmediately after Installation, Pre-use
Flow Rate Accuracy VerificationPost-Installation, Annually
Pressure Gauge FunctionalityPost-Installation, Annually

    How Much Is An Oxygen Cylinder Regulator In Nigeria?

    The cost of an oxygen cylinder regulator in Nigeria can vary significantly based on several factors, including the brand, features, material quality, and whether the unit is new or refurbished. For businesses and healthcare providers in Nigeria, understanding these price ranges is crucial for budgeting and procurement.

    New regulators generally offer the latest technology, guaranteed performance, and a manufacturer's warranty. Prices for new, quality oxygen cylinder regulators typically fall within the range of ₦25,000 to ₦80,000+. High-end models with advanced pressure gauges, durable materials like brass or stainless steel, and specific safety features will command higher prices. Smaller, basic models for domestic or less demanding clinical use might be found at the lower end of this spectrum.

    Refurbished oxygen cylinder regulators present a more budget-friendly option. These units have been previously used, inspected, repaired if necessary, and restored to a functional condition. The price for refurbished regulators can range from approximately ₦10,000 to ₦40,000. While offering significant cost savings, it's vital to ensure that refurbished units are sourced from reputable suppliers who conduct thorough quality checks and offer a limited warranty for peace of mind. The lifespan and reliability of a refurbished regulator can be influenced by the quality of the refurbishment process.

    When making a purchase decision, consider the specific requirements of your medical facility or application. Factors like the type of oxygen cylinder, required pressure output, and desired durability will influence the best choice and its associated cost.

    Affordable Oxygen Cylinder Regulator Options

    We understand the critical need for reliable oxygen delivery systems, especially for healthcare facilities operating within budget constraints in Nigeria. That's why we offer a range of value-focused oxygen cylinder regulator options designed to provide essential functionality without compromising on quality. Explore our selection of expertly refurbished units, ensuring dependable performance at a significantly reduced cost. Additionally, we often have high-quality demo models available, providing near-new performance from units that have seen minimal use. For facilities prioritizing core needs, our entry-level systems deliver robust and safe oxygen regulation for everyday clinical demands. These options are meticulously inspected and tested to meet stringent safety standards, making advanced oxygen therapy more accessible across Nigeria.

    Option TypeIdeal ForKey Features
    Refurbished UnitsFacilities seeking substantial savings with proven reliability.Thoroughly inspected, repaired, and certified for performance and safety.
    Demo ModelsFacilities wanting near-new condition at a discounted price.Minimal prior usage, often indistinguishable from new, with full functional checks.
    Entry-Level SystemsBasic clinical needs and initial equipment outlays.Robust construction, essential pressure regulation and flow control features, user-friendly design.

    Benefits of Our Value Options:

    • Significant cost savings compared to new units.
    • Reliable performance backed by thorough inspection and testing.
    • Extended equipment lifespan for refurbished and demo models.
    • Essential functionality for effective patient care.
    • Accessible oxygen regulation for budget-conscious facilities.

    Verified Oxygen Cylinder Regulator Suppliers In Nigeria

    When sourcing critical medical equipment like oxygen cylinder regulators in Nigeria, reliability and assurance are paramount. Franance Health stands out as a premier partner, offering unparalleled value and peace of mind to healthcare providers across the nation. Our commitment to excellence is built upon a foundation of strong OEM partnerships, dedicated local engineering expertise, and comprehensive warranty support, ensuring you receive the highest quality products and unwavering service.

    BenefitFranance Health Advantage
    Product AuthenticityDirect OEM Partnerships ensuring genuine parts
    Technical SupportLocal engineering team for tailored solutions
    Investment ProtectionComprehensive warranty and ongoing support

    Why Choose Franance Health?

    • Direct OEM Partnerships: We maintain direct relationships with leading Original Equipment Manufacturers (OEMs) of oxygen cylinder regulators. This ensures we supply genuine, high-quality products that meet international standards and regulatory requirements. Our direct sourcing eliminates intermediaries, guaranteeing authenticity and competitive pricing.
    • Local Engineering Team: Franance Health boasts a team of highly skilled local engineers. This in-house expertise allows us to provide tailored technical support, installation guidance, and prompt troubleshooting services. Our engineers understand the specific operational environments and challenges within Nigeria, offering solutions that are both effective and efficient.
    • Comprehensive Warranty and Support: We stand behind the quality of every oxygen cylinder regulator we supply. All our products come with robust warranty coverage, providing you with confidence in your investment. Beyond the warranty period, our dedicated customer support team is always available to address any queries or concerns, ensuring the long-term performance and reliability of your equipment.

    Standard Configuration & Accessories

    When you purchase an oxygen cylinder regulator in Nigeria, you can expect a comprehensive package designed for immediate and effective use. The standard configuration typically includes the essential components for safe and accurate oxygen delivery from a medical cylinder. While probes, coils, workstations, and UPS systems are separate categories of medical equipment, our oxygen regulators are designed to integrate seamlessly with existing medical infrastructure and power sources when needed. The primary focus of the 'in the box' experience is on the regulator itself and its immediate supporting elements.

    ComponentPurposeNotes for Nigerian Market
    Oxygen Cylinder Regulator UnitControls and reduces high pressure from the oxygen cylinder to a safe, usable level.Ensures consistent and controllable oxygen delivery.
    CGA 870 ConnectorThe standard fitting that attaches the regulator to the oxygen cylinder valve.Crucial for compatibility with most medical oxygen cylinders readily available in Nigeria.
    Flow MeterAllows healthcare professionals to precisely set and adjust the rate of oxygen flow to the patient.Typically features clearly marked incremental settings for ease of use.
    Humidifier Bottle ConnectorA port designed to accept a standard humidifier bottle, which adds moisture to the delivered oxygen.Important for patient comfort, especially during prolonged oxygen therapy. Humidifier bottles are usually purchased separately.
    Oxygen Outlet PortThe connection point where standard oxygen tubing is attached to deliver oxygen to the patient.Designed to securely connect to common medical oxygen tubing.

    What's Typically Included:

    • Oxygen Cylinder Regulator Unit (with pressure gauge)
    • CGA 870 Connector (standard for most medical oxygen cylinders in Nigeria)
    • Flow Meter with Selectable Flow Rates (e.g., 0-15 L/min)
    • Humidifier Bottle Connector (for attaching a separate humidifier)
    • Oxygen Outlet Port (for connecting tubing to the patient)
    • User Manual & Operating Instructions

    Warranty & Maintenance Plans

    We understand the critical nature of reliable oxygen therapy. That's why our oxygen cylinder regulators in Nigeria come with comprehensive warranty and maintenance plans designed to ensure your equipment's longevity and optimal performance. Our standard warranty covers manufacturing defects and faulty materials for a specified period, offering peace of mind and protection for your investment. Beyond the initial warranty, we offer tailored Preventive Maintenance Programs (PPM) to proactively identify and address potential issues, minimizing downtime and extending the operational life of your regulators. Crucially, we guarantee the consistent availability of genuine spare parts, ensuring that any necessary repairs or replacements are swift and efficient, keeping your medical facility operational.

    Warranty PeriodIncluded ServicesPPM Frequency (Recommended)
    12 MonthsCovers manufacturing defects and faulty materials.Annually (or as per usage guidelines)
    24 Months (Optional Extended Warranty)Includes standard warranty plus additional protection.Bi-annually (recommended for high-usage environments)

    Key Features of Our Plans:

    • Standard manufacturer's warranty against defects.
    • Proactive Preventive Maintenance Programs (PPM) to ensure peak performance.
    • Guaranteed availability of genuine spare parts for timely repairs.
    • Extended service contracts for long-term operational assurance.
    In-Depth Guidance

    Frequently Asked Questions

    Background
    Phase 02: Execution

    Ready whenever you are

    Let's discuss your Oxygen Cylinder Regulator in Nigeria requirements in Nigeria.