
C-Arm/Fluoroscopy Image Chain Repair Service in Namibia
Engineering Excellence & Technical Support
C-Arm/Fluoroscopy Image Chain Repair Service High-standard technical execution following OEM protocols and local regulatory frameworks.
Rapid On-Site C-Arm Repair
Minimize downtime with our expedited on-site repair service across Namibia. Our certified technicians are equipped to diagnose and resolve C-Arm/Fluoroscopy image chain issues quickly, ensuring your diagnostic capabilities remain operational.
Expert C-Arm Image Chain Expertise
Leverage our deep understanding of C-Arm and Fluoroscopy imaging systems. We specialize in the intricate components of your image chain, from X-ray generators and image intensifiers to detectors and processing units, guaranteeing precise and effective repairs.
Cost-Effective C-Arm Maintenance Solutions
Maximize your budget with our competitive and transparent pricing for C-Arm/Fluoroscopy image chain repairs in Namibia. We offer comprehensive service plans and component replacements designed for longevity, providing exceptional value and reducing long-term operational costs.
What Is C-arm/fluoroscopy Image Chain Repair Service In Namibia?
C-Arm/Fluoroscopy Image Chain Repair Service in Namibia refers to the specialized technical maintenance, troubleshooting, and restoration of the imaging components within a C-arm fluoroscopy system. This service ensures optimal performance and diagnostic accuracy of the X-ray imaging equipment used in various medical procedures. The "image chain" encompasses all the elements that generate, process, and display the X-ray image, including the X-ray generator, image intensifier or flat-panel detector, video camera, image processing hardware, and display monitors. Repair services address hardware malfunctions, software glitches, calibration issues, and component degradation that can impair image quality, introduce artifacts, or lead to system downtime.
| Typical Use Cases for C-Arm/Fluoroscopy Image Chain Repair | Specific Procedures Requiring Intact Image Chain | Potential Issues Addressed by Repair Service |
|---|---|---|
| Orthopedic Surgery (e.g., fracture reduction, spinal surgery, joint replacements) | Image clarity for bone alignment, hardware placement visualization, and surgical navigation. | Low image brightness, excessive noise, image lag, geometric distortions, detector dead pixels/lines, incorrect magnification. |
| Cardiology and Interventional Radiology (e.g., angiography, stent placement, embolization) | High-resolution imaging for visualizing blood vessels, guidewires, and contrast flow in real-time. | Artifacts obscuring vessel lumen, poor contrast resolution, motion blur, flickering image, data acquisition errors. |
| Pain Management (e.g., nerve blocks, epidural injections) | Precise localization of anatomical targets for accurate needle placement. | Inaccurate needle visualization, ghosting artifacts, inconsistent image positioning, loss of image signal. |
| Urology (e.g., retrograde pyelography, lithotripsy) | Visualization of the urinary tract and detection of urinary stones. | Dim or washed-out images, poor detail of internal structures, intermittent image display, radiation output inconsistencies. |
| Emergency Room Procedures (e.g., foreign body removal, chest tube insertion) | Rapid and clear visualization of anatomical structures in acute settings. | Slow image acquisition, system unresponsiveness, display color inaccuracies, calibration drift leading to inaccurate measurements. |
Who Needs C-Arm/Fluoroscopy Image Chain Repair Service?
- Hospitals and healthcare facilities in Namibia utilizing C-arm fluoroscopy systems for diagnostic and interventional procedures.
- Surgical centers and outpatient clinics performing minimally invasive procedures requiring real-time imaging.
- Radiology departments responsible for the maintenance and operational integrity of their imaging equipment.
- Medical equipment maintenance and biomedical engineering departments overseeing the upkeep of C-arm systems.
- Any entity operating C-arm/fluoroscopy equipment that experiences performance degradation or system failure.
Who Needs C-arm/fluoroscopy Image Chain Repair Service In Namibia?
The need for C-arm/Fluoroscopy image chain repair services in Namibia is crucial for maintaining the operational readiness of medical facilities. These sophisticated imaging systems are vital for a wide range of diagnostic and interventional procedures. When they malfunction, it can lead to significant disruptions in patient care, delayed treatments, and increased costs. Therefore, reliable and timely repair services are essential to ensure that Namibian healthcare providers can continue to offer high-quality medical imaging and minimally invasive interventions.
| Department | Specific Medical Procedures Requiring C-Arm/Fluoroscopy | Impact of Malfunction |
|---|---|---|
| Orthopedics | Fracture reduction and fixation, joint replacement surgery, spinal surgery, arthroscopy | Delayed or cancelled surgeries, inability to perform real-time guidance during procedures, increased patient discomfort and risk of complications. |
| Cardiology | Angiography, angioplasty, stent placement, pacemaker implantation, electrophysiology studies | Inability to diagnose and treat cardiovascular blockages and arrhythmias, critical delays in emergency cardiac interventions, leading to increased morbidity and mortality. |
| Pain Management | Nerve blocks, epidural injections, facet joint injections, radiofrequency ablation | Inability to accurately guide needles for pain relief procedures, leading to ineffective treatment and continued patient suffering. |
| Urology | Cystography, urethrography, stent placement, percutaneous nephrostolithotomy | Difficulties in diagnosing and treating urinary tract abnormalities, complications in stone removal procedures, potential for increased patient discomfort and infection risk. |
| Gastroenterology | ERCP (Endoscopic Retrograde Cholangiopancreatography), barium studies | Challenges in diagnosing and treating biliary and pancreatic duct issues, limited ability to perform complex endoscopic interventions. |
| General Surgery | Placement of surgical drains, foreign body localization, some laparoscopic procedures | Increased reliance on open surgery due to lack of intraoperative imaging, potential for complications and longer recovery times. |
| Emergency Departments | Trauma assessments, foreign body localization, initial assessment of fractures | Delays in diagnosing and managing acute injuries, potentially leading to suboptimal patient outcomes. |
| Radiology Departments | Interventional radiology procedures, biopsies, drainages | Reduced capacity to perform minimally invasive image-guided interventions, impacting patient recovery and hospital efficiency. |
Target Customers and Departments Requiring C-Arm/Fluoroscopy Image Chain Repair Service in Namibia
- Hospitals (Public and Private)
- Specialty Clinics
- Diagnostic Imaging Centers
- Surgical Centers
- Government Health Facilities
C-arm/fluoroscopy Image Chain Repair Service Process In Namibia
This document outlines the comprehensive service process for C-Arm/Fluoroscopy image chain repair in Namibia, covering the workflow from initial inquiry to successful execution and follow-up. The process is designed to be efficient, transparent, and to ensure minimal disruption to clinical operations.
| Phase | Stage | Key Activities | Responsible Party | Expected Outcome |
|---|---|---|---|---|
| Phase 1: Inquiry & Initial Assessment | Initial Contact | Client contacts service provider with C-Arm/Fluoroscopy issue. | Client, Service Provider | Acknowledgement of inquiry, basic understanding of the problem. |
| Information Gathering | Service provider collects details: make/model of C-Arm, nature of the image chain defect, urgency, location, previous repair history. | Service Provider | Sufficient information for preliminary assessment and potential remote troubleshooting. | |
| Remote Troubleshooting (Optional) | Guided by service provider to perform basic checks, potentially resolving minor issues without on-site visit. | Client (with guidance), Service Provider | Potential resolution of simple issues, reduced need for on-site service. | |
| Phase 2: Quotation & Scheduling | Diagnosis & Parts Identification | If remote troubleshooting fails, service provider assesses parts needed for repair. | Service Provider | Identification of required spare parts and estimated labor hours. |
| Quotation Generation | Service provider generates a detailed quotation including parts, labor, travel, and any applicable taxes. | Service Provider | Transparent and itemized cost estimate for the client. | |
| Client Approval & Scheduling | Client reviews and approves the quotation. Service provider and client agree on a mutually convenient date and time for the on-site visit. | Client, Service Provider | Formal agreement on service cost and scheduled repair date/time. | |
| Phase 3: On-Site Diagnosis & Repair | Technician Dispatch | Certified technician travels to the client's facility in Namibia with necessary tools and initial spare parts. | Service Provider | On-site presence of qualified technician. |
| In-Depth Diagnosis | Technician performs a thorough on-site inspection and diagnostic tests to pinpoint the exact cause of the image chain failure. | Service Provider (Technician) | Accurate identification of the faulty component(s). | |
| Component Replacement/Repair | The technician replaces faulty parts or performs necessary repairs on the image intensifier, camera, digital acquisition system, or other relevant components. | Service Provider (Technician) | Restoration of the faulty image chain components. | |
| Quality Checks | Initial visual and functional checks of the repaired components. | Service Provider (Technician) | Confirmation of basic functionality. | |
| Phase 4: Testing & Calibration | System Testing | Comprehensive testing of the entire C-Arm/Fluoroscopy system, focusing on image quality, signal strength, artifact reduction, and overall performance. | Service Provider (Technician) | Verification of system functionality and performance against specifications. |
| Calibration | Precise calibration of the image chain components to ensure accurate and optimal image acquisition. | Service Provider (Technician) | Ensured accuracy and optimal image output. | |
| Client Demonstration | Technician demonstrates the repaired system's functionality and image quality to the client. | Service Provider (Technician), Client | Client's confirmation of satisfactory repair and performance. | |
| Phase 5: Completion & Documentation | Final Report | Technician prepares a detailed service report including diagnosis, parts used, work performed, test results, and calibration details. | Service Provider (Technician) | Comprehensive record of the repair process. |
| Invoicing | Service provider issues the final invoice based on the approved quotation and actual work performed. | Service Provider | Accurate billing for services rendered. | |
| Client Sign-off | Client formally signs off on the service report, acknowledging the completion of the repair. | Client, Service Provider (Technician) | Formal acceptance of the completed service. | |
| Phase 6: Follow-up & Support | Post-Service Follow-up | Service provider may conduct a follow-up call or email to ensure the client's continued satisfaction and system performance. | Service Provider | Customer satisfaction and early identification of any lingering issues. |
| Warranty & Support | Information on any warranty provided for parts and labor. Offer of ongoing technical support and maintenance contracts. | Service Provider | Client confidence in the repair and assurance of continued support. |
C-Arm/Fluoroscopy Image Chain Repair Service Workflow
- Phase 1: Inquiry & Initial Assessment
- Phase 2: Quotation & Scheduling
- Phase 3: On-Site Diagnosis & Repair
- Phase 4: Testing & Calibration
- Phase 5: Completion & Documentation
- Phase 6: Follow-up & Support
C-arm/fluoroscopy Image Chain Repair Service Cost In Namibia
Repairing C-arm and fluoroscopy imaging chains in Namibia can vary significantly in cost due to several factors. These complex medical devices require specialized knowledge and parts, making the repair process intricate. The pricing is influenced by the type and severity of the malfunction, the specific model and manufacturer of the C-arm/fluoroscopy unit, the availability and cost of replacement parts, and the labor rates of the qualified technicians. Emergency or expedited repairs often incur additional charges. The Namibian market for such specialized medical equipment repair is niche, meaning fewer service providers might lead to higher pricing. It's crucial to obtain detailed quotes from reputable service providers to understand the full scope of work and associated costs.
| Repair Type/Component | Estimated Cost Range (NAD) | Notes |
|---|---|---|
| Minor Calibration/Software Issues | 1,500 - 4,000 | Includes technician's call-out and basic troubleshooting. |
| Connector/Cable Replacement | 3,000 - 7,500 | Cost depends on the specific cable and accessibility. |
| Image Intensifier Repair/Replacement | 25,000 - 150,000+ | Highly variable depending on size, technology, and if it's a repairable component or requires full replacement. This is often the most expensive part. |
| X-ray Tube Repair/Replacement | 30,000 - 100,000+ | Depends on the tube's wattage, type (rotating anode, stationary), and manufacturer. Often requires specialized handling. |
| Detector (Flat Panel) Repair/Replacement | 50,000 - 200,000+ | Cost is highly dependent on the detector size, resolution, and technology (CCD, amorphous silicon, etc.). |
| Power Supply Unit (PSU) Repair/Replacement | 10,000 - 30,000 | Cost varies with the PSU's complexity and output. |
| Full System Diagnostics and General Service | 2,000 - 5,000 | This is a preventative or troubleshooting fee, often a starting point before specific component repair costs. |
| Emergency/Expedited Service | Additional 20% - 50% | On top of the standard repair cost. |
Factors Influencing C-Arm/Fluoroscopy Image Chain Repair Costs in Namibia
- Nature and Complexity of the Fault: Simple issues like connector problems or minor calibration might be less expensive than major component failures (e.g., image intensifier, X-ray tube, detector replacement).
- C-Arm/Fluoroscopy Unit Model and Manufacturer: Different brands and models have varying complexities in their imaging chains and may use proprietary parts that are more expensive or harder to source.
- Availability and Cost of Replacement Parts: Original manufacturer parts are generally more expensive than third-party alternatives, but offer guaranteed compatibility. If parts need to be imported, shipping costs and import duties will also factor in.
- Technician Expertise and Labor Rates: Specialized biomedical engineers with C-arm/fluoroscopy experience command higher hourly rates. The location of the service provider and their overhead costs also contribute.
- Urgency of the Repair: Emergency or same-day service requests typically come with a premium fee compared to scheduled maintenance or standard repairs.
- Diagnostic Fees: Many service providers charge an initial fee to diagnose the problem, which is often then credited towards the total repair cost if you proceed with the service.
- Geographic Location within Namibia: If the repair requires travel to remote areas, transportation and accommodation costs for the technician might be added.
- Warranty Status of the Equipment: If the unit is still under manufacturer warranty, the repair might be covered, significantly reducing out-of-pocket expenses.
Affordable C-arm/fluoroscopy Image Chain Repair Service Options
Maintaining the optimal performance of your C-arm/fluoroscopy imaging equipment is crucial for accurate diagnoses and efficient patient care. When repairs are needed, the cost can be a significant concern for healthcare facilities. This guide explores affordable repair service options, focusing on value bundles and cost-saving strategies to help you manage your imaging chain maintenance budget effectively. We'll look at how proactive maintenance, extended service contracts, and strategic part sourcing can make a difference.
| Service Option | Description | Value Proposition | Cost-Saving Strategy |
|---|---|---|---|
| Third-Party Repair Services | Independent companies specializing in C-arm/fluoroscopy repair, often offering more competitive pricing than OEM (Original Equipment Manufacturer) services. | Lower labor rates, faster turnaround times, access to refurbished parts, specialized expertise. | Obtain multiple quotes, research company reputation and certifications, inquire about warranty on repairs. |
| Refurbished Parts and Modules | Using pre-owned but fully tested and certified parts or complete modules (e.g., image intensifier, camera head) instead of new ones. | Significant cost reduction compared to new parts, reduces equipment downtime by allowing for pre-emptive swapping. | Ensure parts come from reputable suppliers with quality assurance processes and warranties. Verify compatibility with your specific C-arm model. |
| Extended Service Contracts (Third-Party) | Annual or multi-year contracts with third-party providers covering parts, labor, and preventative maintenance. | Predictable annual costs, reduces unexpected repair expenses, proactive maintenance helps prevent major failures. | Negotiate contract terms carefully, understand coverage limitations, compare pricing and service levels across providers. |
| Preventative Maintenance Programs | Regularly scheduled inspections, cleaning, calibration, and minor adjustments to identify and address potential issues before they lead to major breakdowns. | Minimizes unexpected downtime, extends equipment lifespan, maintains image quality, can be integrated into third-party service contracts. | Schedule based on manufacturer recommendations and usage patterns. Consider bundled pricing with repair services. |
| Value Bundles | Packages offered by service providers that combine multiple services, such as preventative maintenance, on-site support, and discounted parts or labor for repairs. | Comprehensive coverage, simplifies vendor management, often offers bundled discounts. | Evaluate the specific services included in the bundle and ensure they align with your facility's needs and equipment usage. |
| Strategic Parts Sourcing | Developing relationships with multiple parts suppliers (OEM and third-party) to leverage competitive pricing and availability. | Access to a wider range of parts, potential for bulk discounts, reduces reliance on a single supplier. | Maintain an inventory of critical spare parts, if feasible, for immediate replacement of common failure points. |
| Remote Diagnostics and Support | Leveraging technology for remote troubleshooting and diagnostics to reduce the need for on-site technician visits for minor issues. | Faster problem resolution, reduced travel costs for technicians, can preempt costly on-site interventions. | Ensure your C-arm is equipped with the necessary remote access capabilities and that your service provider offers this option. |
Key Components of a C-Arm/Fluoroscopy Imaging Chain
- Image Intensifier (II)
- Camera Head (CCD/CMOS)
- Video Processor/Acquisition System
- Monitor(s)
- C-arm Gantry and Mechanics
- X-ray Generator and Tube
- Workstation/Image Management System
Verified Providers In Namibia
Ensuring access to quality healthcare is paramount, and in Namibia, the accreditation and verification of healthcare providers play a crucial role in guaranteeing patient safety and optimal outcomes. Franance Health stands out as a leading entity in this space, rigorously vetting and certifying healthcare professionals and facilities. This verification process not only builds trust but also signifies a commitment to the highest standards of medical practice, ethical conduct, and patient care. Choosing a Franance Health-verified provider means opting for a healthcare experience that prioritizes excellence, expertise, and unwavering dedication to your well-being.
| Credential Category | Verification Criteria | Benefits to Patients |
|---|---|---|
| Medical Professionals (Doctors, Specialists) | Valid medical license, board certifications, proof of ongoing education, peer reviews, criminal background checks. | Access to highly qualified and competent medical expertise, assurance of up-to-date knowledge and skills. |
| Healthcare Facilities (Hospitals, Clinics) | Adherence to national health regulations, quality management systems, infection control protocols, patient feedback mechanisms, availability of essential equipment and resources. | Safe and hygienic environment, access to necessary medical technology and infrastructure, reliable and consistent service delivery. |
| Ancillary Services (Laboratories, Pharmacies) | Licensing, quality control procedures, proper handling and dispensing of medications/tests, adherence to professional standards. | Accurate diagnostic results, safe and effective medication access, reliable support services for medical treatment. |
Why Franance Health Credentials Represent the Best Choice for Healthcare in Namibia:
- Rigorous Vetting Process: Franance Health employs a multi-faceted approach to verification, examining qualifications, experience, and adherence to Namibian medical regulations.
- Commitment to Excellence: Verified providers demonstrate a dedication to continuous professional development and staying abreast of the latest medical advancements.
- Patient Safety First: Accreditation ensures that providers meet stringent safety protocols and maintain a secure healthcare environment.
- Ethical Practice Assurance: Franance Health verifies that providers adhere to the highest ethical standards in their practice and patient interactions.
- Enhanced Trust and Confidence: The verified status provides patients with the assurance that they are receiving care from competent and trustworthy professionals.
- Access to Quality Care: By identifying and promoting verified providers, Franance Health helps individuals navigate the healthcare landscape with confidence, ensuring they find reliable and high-quality medical services.
- Upholding National Health Standards: Franance Health's work is integral to maintaining and elevating the overall standard of healthcare delivery across Namibia.
Scope Of Work For C-arm/fluoroscopy Image Chain Repair Service
This Scope of Work (SOW) outlines the requirements for the repair and servicing of C-arm/Fluoroscopy imaging chains. The objective is to restore the system to optimal operational status, ensuring accurate and reliable image acquisition for diagnostic and interventional procedures. This SOW details the technical deliverables, standard specifications, and associated tasks for a comprehensive repair service.
| System Component | Standard Specification/Requirement | Testing Procedure | Acceptance Criteria |
|---|---|---|---|
| C-Arm Mechanics/Gantry | Smooth, free, and precise movement of gantry and arms. No audible or visible strain during motion. All locks and brakes functional and secure. | Manual manipulation of all gantry axes (rotation, angulation, orbital, vertical). Verification of lock engagement and disengagement. Visual inspection for wear or damage. | Movement is fluid and without resistance. Locks engage firmly and release easily. No unusual noises or vibrations. |
| X-ray Generator | Stable kVp, mA, and exposure time output within manufacturer's tolerances. No excessive noise or arcing during operation. Consistent power delivery. | Operate system at various power settings (kVp, mA, time) and measure output using calibrated dosimetry. Monitor for electrical noise or anomalies. | Measured output within +/- 5% of set values. No audible or visible electrical discharge. Consistent performance across multiple exposures. |
| Image Intensifier/Flat Panel Detector | High signal-to-noise ratio (SNR). Minimal image artifacts (e.g., distortion, veiling glare, noise). Uniform image brightness and contrast. Correct spatial resolution. | Acquire test phantoms (e.g., resolution grids, contrast detail phantoms) at various settings. Visual assessment of image quality. Quantitative analysis of SNR, MTF (Modulation Transfer Function). | SNR meets or exceeds manufacturer's specifications. Artifacts are imperceptible or negligible. Spatial resolution meets or exceeds specified limits for the detector type. |
| Camera/Acquisition Hardware | Accurate video signal acquisition. Minimal signal degradation. Correct color reproduction (if applicable). Stable frame rate. | Acquire test images and videos. Analyze signal fidelity and frame rate using waveform monitors and frame grabbers. Check for color accuracy (if RGB output). | Signal integrity within specified tolerances. Frame rate is stable and consistent with system capabilities. Color reproduction is accurate. |
| Image Processing Unit/Workstation | Fast and accurate image processing. Correct application of filters and algorithms. Seamless integration with other system components. Responsive user interface. | Perform image acquisition, processing, and display operations. Evaluate processing speed and algorithm effectiveness. Test user interface responsiveness. | Image processing time within acceptable limits. Applied filters produce expected results. User interface is responsive without lag. |
| Connectivity and Networking (DICOM) | Successful transmission and reception of DICOM images to PACS/other modalities. Correct patient and study information association. Network security protocols adhered to. | Send and receive test images to/from a PACS or modality simulator. Verify DICOM header information and object class. Test network connectivity and security settings. | DICOM images are transmitted and received without errors. All metadata is correctly populated. Network communication is secure. |
| Laser Localizer (if applicable) | Accurate and stable laser beam projection. Precise alignment with the central X-ray beam. | Project laser onto a grid or marker at various gantry positions. Measure laser beam accuracy and stability relative to the X-ray beam path. | Laser projection is within +/- 1 mm accuracy of the X-ray beam center. Beam is stable and does not drift. |
| Cooling System | Effective and consistent cooling of X-ray tube and other heat-generating components. Temperature monitoring within safe operating ranges. | Monitor system temperatures during extended operation at high power. Verify cooling system fan speed and fluid levels (if applicable). | Component temperatures remain within manufacturer-specified safe operating limits. Cooling system functions audibly and visibly as designed. |
Key Technical Deliverables
- Comprehensive diagnostic report identifying all faults and required repairs.
- Successful repair and recalibration of the identified faulty components within the imaging chain.
- Verification of image quality and system performance against established benchmarks.
- Updated system documentation reflecting all repairs and modifications.
- Post-repair functional testing and sign-off by authorized personnel.
- Warranty on replaced parts and workmanship.
- Training for on-site technical staff on basic maintenance and troubleshooting (if applicable).
Service Level Agreement For C-arm/fluoroscopy Image Chain Repair Service
This Service Level Agreement (SLA) outlines the terms and conditions for the repair and maintenance services provided for C-Arm/Fluoroscopy Image Chain systems. It defines the expected response times, resolution targets, and uptime guarantees to ensure minimal disruption to clinical operations. This SLA is between [Your Company Name] (hereinafter referred to as "Provider") and [Client Institution Name] (hereinafter referred to as "Client").
| Service Level | Definition | Response Time Target | Resolution Target | Uptime Guarantee |
|---|---|---|---|---|
| Critical System Failure | Complete loss of image acquisition or critical system functionality preventing diagnostic imaging. | Within 4 business hours of notification. | Within 24 business hours of technician arrival. | 98% (excluding scheduled maintenance and outages caused by client-side issues). |
| Major System Degradation | Significant degradation in image quality, intermittent system failures, or loss of non-critical functionalities impacting workflow. | Within 8 business hours of notification. | Within 48 business hours of technician arrival. | 98% (excluding scheduled maintenance and outages caused by client-side issues). |
| Minor System Issues / Routine Maintenance | Minor performance issues, error messages that do not impede core functionality, or scheduled preventive maintenance. | Within 24 business hours of notification or as per scheduled maintenance plan. | During scheduled service window or within 72 business hours of technician arrival. | N/A (focus on proactive prevention of failures). |
Scope of Services
- On-site repair of C-Arm/Fluoroscopy Image Chain components, including but not limited to imaging detectors, image intensifiers, generators, x-ray tubes, gantry, and associated control consoles.
- Preventive maintenance services as per manufacturer recommendations and industry best practices.
- Remote diagnostics and troubleshooting support.
- Replacement of defective parts with genuine or equivalent quality components.
- Post-repair verification and performance testing.
Frequently Asked Questions

Ready when you are
Let's scope your C-Arm/Fluoroscopy Image Chain Repair Service in Namibia project in Namibia.
Scaling healthcare logistics and technical systems across the entire continent.

