Shielding Integrity Assurance
Our meticulous installation process utilizes high-conductivity materials and specialized sealing techniques to guarantee the highest level of RF shielding effectiveness, preventing external electromagnetic interference from compromising MRI diagnostic accuracy in Libya.
Precise RF Attenuation Measurement
We employ advanced RF spectrum analyzers and field strength meters to perform rigorous pre- and post-installation testing, ensuring compliance with international standards and delivering documented attenuation levels critical for optimal MRI performance.
Optimized RF Current Path Management
Our expertise lies in designing and implementing RF current paths that are specifically engineered to dissipate stray electromagnetic fields efficiently. This ensures minimal eddy currents and signal degradation within the MRI room, leading to superior image quality for Libyan healthcare facilities.
What Is Mri Rf Cage (Faraday Cage) Installation & Testing Service In Libya?
An MRI RF Cage (Faraday Cage) Installation & Testing Service in Libya refers to the specialized provision of services encompassing the design, construction, and verification of radio-frequency shielded enclosures for Magnetic Resonance Imaging (MRI) facilities. The primary objective is to attenuate external electromagnetic interference (EMI) and radio-frequency interference (RFI) to levels that do not compromise the integrity and diagnostic accuracy of the MRI scanner. This involves meticulous site assessment, material selection, precise fabrication and installation of conductive shielding, and rigorous performance testing to ensure compliance with established electromagnetic compatibility (EMC) standards. The service is critical for the optimal functioning of MRI equipment, preventing signal degradation and artifacts that could lead to misdiagnosis.
| Who Needs This Service? | Typical Use Cases | |||
|---|---|---|---|---|
| Hospitals and Healthcare Facilities: Operating departments with MRI suites, diagnostic imaging centers, and medical research institutions in Libya. This includes both public and private sector facilities. | New MRI Suite Construction: Ensuring a new MRI installation meets all necessary electromagnetic shielding requirements from the outset. | MRI Equipment Upgrades or Relocations: When an existing MRI scanner is upgraded, replaced, or moved to a new location within a facility, the RF cage may require re-evaluation, modification, or complete re-installation to ensure optimal performance. | Addressing RF Interference Issues: Facilities experiencing diagnostic inaccuracies, image artifacts, or equipment malfunctions directly attributable to RF interference. | Compliance with Regulatory Standards: Meeting national and international standards for medical device electromagnetic compatibility. |
| Diagnostic Imaging Centers: Dedicated facilities providing MRI as a primary diagnostic tool. | Research Laboratories: Institutions utilizing MRI for scientific research, requiring high signal-to-noise ratios and minimal interference. | Specialized Medical Clinics: Clinics focused on specific medical specialties that rely heavily on MRI diagnostics (e.g., neurology, cardiology, orthopedics). | Veterinary MRI Facilities: Increasingly, veterinary clinics are adopting MRI technology, requiring similar shielding solutions. | Mobile MRI Units: The installation and ongoing maintenance of RF shielding for transportable MRI units. |
Key Components of MRI RF Cage Installation & Testing Service:
- Site Survey and Design: Comprehensive evaluation of the MRI suite's electromagnetic environment, including analysis of potential RF sources. Development of a detailed design plan for the RF cage, considering architectural constraints, door and window shielding, ventilation, and power line filtering.
- Materials Procurement and Fabrication: Sourcing of high-conductivity materials (e.g., copper, aluminum, galvanized steel) for cage construction. Precision fabrication of panels, waveguides, and other structural components to achieve seamless shielding.
- Installation and Construction: Professional installation of the RF cage structure, ensuring continuity of the conductive barrier. Integration of RF-shielded doors, windows, and pass-throughs for utilities (e.g., ventilation, data cabling, power).
- RF Sealing and Gasketing: Application of conductive gaskets and seals at all joints, seams, and openings to maintain RF integrity. Meticulous attention to detail to prevent RF leakage.
- Power Line Filtering: Installation of specialized RF filters on all incoming power lines to prevent RFI ingress through electrical circuits.
- Waveguide Installation: Implementation of RF-tight waveguides for ventilation systems to allow air circulation while blocking RF penetration.
- RF Performance Testing: Conducted by qualified technicians using calibrated RF spectrum analyzers and signal generators. Testing typically involves measuring signal attenuation across a specified frequency range (e.g., 10 kHz to 10 GHz) to verify compliance with industry standards such as IEC 60601-1-2 or local equivalents. This includes testing for RF leakage at critical points, such as door seals and panel joints.
- Certification and Documentation: Provision of detailed test reports and certification confirming the RF cage's compliance with performance specifications. This documentation is essential for regulatory approval and equipment warranty.
Who Needs Mri Rf Cage (Faraday Cage) Installation & Testing Service In Libya?
The installation and testing of MRI RF Cage (Faraday Cage) services are crucial for ensuring the proper functioning and safety of Magnetic Resonance Imaging (MRI) machines. These specialized enclosures are designed to shield sensitive MRI equipment from external electromagnetic interference, which can degrade image quality and even damage the equipment. In Libya, the demand for such services is primarily driven by healthcare institutions, research facilities, and specialized medical imaging centers that operate or are planning to operate MRI scanners. The specific departments within these organizations that would require these services are those directly involved with the acquisition, maintenance, and operation of MRI technology.
| Customer Type | Key Needs Addressed | Typical Department Involvement |
|---|---|---|
| Hospitals & Medical Centers | Image Quality, Equipment Longevity, Patient Safety | Radiology, Biomedical Engineering, Facility Management |
| Specialized Diagnostic Imaging Clinics | High-Resolution Imaging, Operational Efficiency | Imaging Services, Technical Operations |
| Research Institutions & Universities | Data Integrity, Accurate Research Outcomes, Training | Medical Research Labs, Physics, Biomedical Engineering |
| Medical Equipment Suppliers & Integrators | Turnkey Solutions, Compliance with Standards, Client Satisfaction | Installation, Service & Maintenance, Project Management |
| Government & Public Health Organizations | Accessible Healthcare, Public Health Investment, Standardized Care | Ministry of Health, Infrastructure Development, Procurement |
Target Customers and Departments in Libya Requiring MRI RF Cage Installation & Testing Services
- {"title":"Hospitals & Medical Centers","departments":["Radiology Department","Medical Imaging Department","Biomedical Engineering Department","Facility Management / Maintenance Department","IT Department (for network interference considerations)","Procurement Department"],"description":"These are the primary end-users of MRI technology and will have the most significant need for RF cage services. This includes both public and private healthcare facilities."}
- {"title":"Specialized Diagnostic Imaging Clinics","departments":["Imaging Services Department","Technical Operations","Equipment Maintenance Team"],"description":"Clinics focusing exclusively on advanced diagnostic imaging, including MRI, will require these services for their equipment. These may be standalone or affiliated with larger medical groups."}
- {"title":"Research Institutions & Universities with Medical Programs","departments":["Medical Research Laboratories","Physics Departments (specifically for MR physics)","Biomedical Engineering Departments","University Hospitals","Purchasing & Facilities Management"],"description":"Academic institutions conducting medical research or training future medical professionals often utilize MRI scanners. Ensuring the integrity of their research data and educational tools is paramount."}
- {"title":"Medical Equipment Suppliers & Integrators","departments":["Installation & Commissioning Teams","Service & Maintenance Departments","Project Management"],"description":"Companies that sell, install, and service MRI machines in Libya will need to partner with or employ qualified RF cage installation and testing experts. This is often a part of the complete MRI system package."}
- {"title":"Government & Public Health Organizations","departments":["Ministry of Health (or equivalent)","Public Health Infrastructure Development Units","Procurement and Logistics Departments"],"description":"Entities responsible for public health infrastructure and the provision of healthcare services may be involved in the procurement and maintenance of MRI facilities, particularly in underserved areas."}
Mri Rf Cage (Faraday Cage) Installation & Testing Service Process In Libya
This document outlines the comprehensive workflow for MRI RF Cage (Faraday Cage) installation and testing services provided in Libya, from initial client inquiry to final project completion. The process is designed to ensure a seamless, compliant, and high-quality execution, adhering to international standards and local regulations.
| Phase | Stage/Step | Description | Key Activities | Deliverables/Outcomes | Libyan Considerations |
|---|---|---|---|---|---|
| Phase 1: Inquiry & Initial Consultation | Initial Contact | Client expresses interest in MRI RF Cage services. | Receive inquiry (email, phone, website). Initial discussion of project scope, requirements, and client's existing facility. | Understanding of client's needs, preliminary project scope. | Establish communication channels, understand local business practices. |
| Information Gathering | Collect detailed information about the MRI project and facility. | Review architectural drawings, MRI equipment specifications, room dimensions, power requirements, and potential interference sources. | Clarified project scope and technical requirements. | Adherence to local import regulations for specialized equipment. | |
| Phase 2: Site Survey & Design | On-Site Assessment | Thorough inspection of the proposed installation site. | Conduct detailed measurements of the room, assess structural integrity, identify existing electrical and HVAC systems, and evaluate site accessibility for materials and personnel. | Comprehensive site assessment report, identification of potential challenges. | Safety regulations and accessibility for foreign personnel and equipment. |
| RF Cage Design & Engineering | Develop a detailed technical design for the RF cage. | Based on site survey and MRI specifications, design the cage structure, material selection (e.g., copper, aluminum, steel), door sealing mechanisms, ventilation solutions, and power/signal filtering requirements. Comply with relevant international standards (e.g., IEC 60601-1-2). | Detailed design drawings, material specifications, technical blueprints. | Availability of specific materials and compliance with local building codes. | |
| Phase 3: Proposal & Contract | Technical Proposal | Present a detailed technical and commercial proposal to the client. | Outline the proposed solution, materials, scope of work, project timeline, testing methodology, and quality assurance plan. Include cost breakdown. | Formal technical proposal document. | Clarity on currency and payment terms. |
| Contract Negotiation & Agreement | Finalize terms and conditions with the client. | Negotiate pricing, payment schedules, contract duration, warranties, and responsibilities. Formalize the agreement through a legally binding contract. | Signed contract, project commencement agreement. | Legal framework and contract enforcement in Libya. | |
| Phase 4: Procurement & Logistics | Material Procurement | Acquire all necessary materials and components. | Order specialized RF shielding materials, doors, filters, and other components from reputable suppliers. Manage customs clearance and import procedures. | Procured materials ready for shipment. | Navigating import duties, customs clearance complexities, and lead times for specialized materials. |
| Logistics & Transportation | Plan and execute the transportation of materials and equipment to the site in Libya. | Arrange for international shipping, local transportation, warehousing, and secure delivery to the installation site. Ensure compliance with all import/export regulations. | Materials and equipment safely delivered to the site. | Challenges with infrastructure, security, and customs procedures. | |
| Phase 5: Installation | Site Preparation | Prepare the installation area for the RF cage. | Ensure the room is cleared, any necessary structural modifications are completed, and power/HVAC are ready for integration. | Site ready for cage construction. | Coordination with local contractors and facility management. |
| RF Cage Construction & Assembly | Install the RF shielding structure. | Skilled technicians construct and assemble the RF cage according to the approved design. This includes wall, ceiling, and floor shielding, door installation, and sealing. | Physically erected RF cage. | Strict adherence to safety protocols for on-site personnel, including expatriates. | |
| Integration of Services | Incorporate essential services into the RF cage. | Install and properly seal RF-shielded doors, ventilation systems (waveguides, filters), power and signal line filters, and any necessary penetrations. | Integrated and sealed RF cage with all necessary penetrations. | Ensuring all integrated components meet RF shielding integrity. | |
| Phase 6: RF Shielding Performance Testing | Pre-Testing Preparations | Conduct preliminary checks before formal testing. | Visual inspection of the entire cage for any potential leaks or defects. Verify all components are correctly installed and sealed. | Pre-test report. | Availability of specialized testing equipment and calibrated instruments. |
| RF Attenuation Testing | Measure the RF shielding effectiveness of the installed cage. | Using specialized equipment and a defined test protocol (e.g., based on IEC 60601-1-2), measure the attenuation of RF signals across a specified frequency range (typically 10 kHz to 10 GHz). This involves generating RF signals outside the cage and measuring their ingress inside. | Detailed RF attenuation test report, identifying any areas of weakness. | Compliance with international testing standards and reporting requirements. | |
| Leak Detection & Remediation | Identify and fix any RF leakage points. | If the attenuation test reveals deviations from required performance, pinpoint the exact locations of leaks and perform necessary repairs (e.g., additional shielding, improved sealing). Retest as needed. | Resolved RF leaks, re-verified performance. | Ensuring timely and effective resolution of any identified issues. | |
| Phase 7: Final Acceptance & Handover | Client Inspection & Verification | Client reviews the completed installation and test results. | Allow the client to conduct a physical inspection of the cage and review the RF attenuation test reports. Address any client queries or concerns. | Client satisfaction and preliminary acceptance. | Clear communication and transparency with the client. |
| Final Documentation & Handover | Provide all necessary project documentation. | Compile and deliver the final project report, including design drawings, installation records, material certificates, RF attenuation test results, warranty information, and user/maintenance guidelines. Formally hand over the completed RF cage. | Comprehensive project handover package, signed acceptance certificate. | Ensuring all documentation is clear and understandable for the client. | |
| Phase 8: Post-Installation Support | Warranty Period | Provide support during the warranty period. | Address any issues that may arise during the warranty period, ensuring the continued performance of the RF cage. | Resolved post-installation issues. | Establishing clear lines of communication for ongoing support. |
| Maintenance & Future Services | Offer ongoing support and maintenance options. | Propose periodic maintenance checks and re-testing services to ensure the long-term integrity and performance of the RF cage. | Long-term client relationship, potential for future service contracts. | Building trust and a reliable reputation for ongoing support. |
MRI RF Cage Installation & Testing Service Workflow in Libya
- Phase 1: Inquiry & Initial Consultation
- Phase 2: Site Survey & Design
- Phase 3: Proposal & Contract
- Phase 4: Procurement & Logistics
- Phase 5: Installation
- Phase 6: RF Shielding Performance Testing
- Phase 7: Final Acceptance & Handover
- Phase 8: Post-Installation Support
Mri Rf Cage (Faraday Cage) Installation & Testing Service Cost In Libya
Installing an MRI Radio Frequency (RF) cage, also known as a Faraday cage, is a critical and complex undertaking that requires specialized expertise and materials to ensure the integrity of MRI scans. The cost of this service in Libya can vary significantly due to several factors. These factors encompass the size and complexity of the MRI suite, the chosen RF shielding materials, the labor involved, site-specific challenges, and the testing procedures employed to verify performance. It's crucial to obtain detailed quotes from qualified contractors experienced in RF shielding for medical facilities.
| Service Component | Estimated Cost Range (LYD) | Notes |
|---|---|---|
| RF Cage Material Supply (per square meter) | 150 - 500+ | Varies significantly based on material type (copper, aluminum, composites) and thickness. |
| RF Shielding Door (single) | 5,000 - 20,000+ | Includes specialized frame, hinges, and sealing mechanisms. |
| RF Shielding Window (per unit) | 2,000 - 8,000+ | Depending on size, frame material, and shielding effectiveness. |
| HVAC Waveguides & Filters | 1,000 - 5,000+ (per unit) | Essential for maintaining airflow while blocking RF signals. |
| Electrical Filters & Conduit | 500 - 3,000+ (per unit) | For power and data lines to prevent RF leakage. |
| Labor & Installation (per technician, per day) | 300 - 800+ | Reflects specialized skills and experience required. |
| Comprehensive RF Testing & Certification | 3,000 - 15,000+ | Includes equipment rental, technician time, and reporting. |
| Project Management & Design Consultation | 1,000 - 5,000+ | For complex installations or specialized requirements. |
| Total Estimated Cost (Small to Medium MRI Suite) | 40,000 - 150,000+ | This is a broad estimate and can be significantly higher for larger or more complex projects. |
Key Pricing Factors for MRI RF Cage Installation & Testing in Libya:
- Size and Layout of the MRI Suite: Larger rooms or rooms with complex shapes requiring more shielding material and intricate fabrication will naturally increase costs.
- Type and Quality of Shielding Materials: Different materials offer varying levels of RF attenuation. Options can range from standard copper or aluminum sheeting to more advanced composite materials, each with a different price point.
- Wall, Floor, and Ceiling Shielding: The scope of shielding required (e.g., all surfaces or specific areas) impacts the material and labor costs.
- Door and Window Requirements: Specialized RF-shielding doors and windows are significantly more expensive than standard building materials.
- Ventilation and Electrical Penetrations: Creating RF-tight penetrations for HVAC systems, power lines, and other services requires specialized waveguides and filters, adding to the cost.
- Structural Modifications: If the existing building requires structural reinforcement or modifications to accommodate the cage, this will add to the overall expense.
- Labor Costs: The complexity of the installation, the number of technicians, and the duration of the project all contribute to labor expenses. Skilled technicians with experience in RF shielding are essential and command higher rates.
- Site Accessibility and Logistics: Difficult-to-access locations or challenging logistical situations can increase transportation and installation costs.
- Testing and Certification: Comprehensive RF testing is mandatory to ensure the cage meets specified attenuation levels. The thoroughness and type of testing (e.g., swept frequency, site standing wave ratio) will affect the final price.
- Contractor's Experience and Reputation: More established and reputable contractors may have higher rates but often offer greater reliability and expertise.
- Project Timeline: Rush projects may incur premium charges.
Affordable Mri Rf Cage (Faraday Cage) Installation & Testing Service Options
Installing a high-quality MRI Radio Frequency (RF) cage, also known as a Faraday cage, is a critical and often costly component of setting up an MRI facility. Our service goes beyond just installation; we offer comprehensive solutions designed to be both effective and economically viable. We understand that budget constraints are a major factor for many healthcare providers. Therefore, we've developed a range of value bundles and cost-saving strategies to ensure you receive a compliant and reliable RF cage without breaking the bank. Our expert team handles everything from initial site assessment and design to meticulous installation and rigorous post-installation testing, ensuring optimal shielding performance and patient safety. We prioritize delivering exceptional value by combining premium materials with efficient construction techniques and flexible service packages.
| Service Tier | Description | Key Inclusions | Potential Cost Savings |
|---|---|---|---|
| Bronze Bundle | Basic RF Cage Installation & Testing for Smaller/Budget-Conscious Projects. | Standard Shielding Material, Basic Design, Installation, and Standard Leakage Testing. | Minimized upfront material costs, streamlined installation process. |
| Silver Bundle | Enhanced RF Cage Installation & Testing for Mid-Range Projects. | Upgraded Shielding Material, Design Consultation, Installation, Leakage Testing, and Basic Field Uniformity Testing. | Balanced cost-effectiveness with improved performance, optimized material selection. |
| Gold Bundle | Premium RF Cage Installation & Comprehensive Testing for Optimal Performance. | High-performance Shielding Material, Custom Design, Full Installation, Advanced Leakage Testing, Full Field Uniformity Testing, and Pre-Certification Walkthrough. | Reduced risk of costly remediation due to thorough initial testing, long-term performance assurance, optimized system uptime. |
| Custom Solutions | Tailored Packages for Unique Project Requirements. | Flexible combinations of services and materials based on specific needs and budget. | Directly addresses specific project needs, eliminating unnecessary services, economies of scale for specialized materials. |
Our Value-Driven MRI RF Cage Services
- Comprehensive Site Assessment: Detailed evaluation of your facility's unique requirements to optimize cage design and minimize material waste.
- Customized Design & Engineering: Tailored solutions to meet specific MRI system shielding needs and architectural constraints.
- High-Performance Shielding Materials: Utilizing proven, durable materials for superior RF attenuation.
- Expert Installation: Experienced technicians ensuring precise construction and adherence to all industry standards.
- Rigorous Testing & Certification: Comprehensive post-installation testing (e.g., LEED testing, field uniformity scans) to guarantee compliance and optimal performance.
- Post-Installation Support: Ongoing technical assistance and maintenance options.
- Project Management: Seamless coordination of all project phases for timely and efficient completion.
Verified Providers In Libya
Navigating healthcare in Libya requires trust and reliability. 'Verified Providers in Libya' aims to highlight organizations and services that meet stringent standards, ensuring quality and safety for patients. Among these, Franance Health stands out as a leading example, demonstrating a commitment to excellence in healthcare delivery and patient care. Their comprehensive approach, cutting-edge facilities, and dedicated medical professionals make them a cornerstone of the Libyan healthcare landscape. This document outlines the credentials that position Franance Health as the best choice for individuals seeking trustworthy and high-quality medical services in Libya.
| Credential/Aspect | Franance Health's Standing | Why it Matters for Patients |
|---|---|---|
| International Accreditation | Holds recognized international healthcare accreditation (e.g., JCI equivalent standards). | Ensures adherence to global best practices in patient care, safety, and operational efficiency. |
| Medical Staff Expertise | Employs board-certified specialists, fellowship-trained physicians, and experienced nurses. | Guarantees access to highly skilled professionals with expertise in various medical disciplines. |
| Technological Advancement | Utilizes advanced diagnostic and therapeutic equipment, including modern imaging and laboratory services. | Facilitates accurate diagnoses, effective treatments, and improved patient outcomes. |
| Service Portfolio | Offers a wide spectrum of services from primary care to complex surgical procedures and specialized treatments. | Provides a centralized hub for diverse healthcare needs, minimizing the need for multiple providers. |
| Quality Management Systems | Implements robust quality assurance protocols, infection control measures, and patient feedback mechanisms. | Prioritizes patient safety, reduces risks, and continuously strives for service improvement. |
| Patient-Centric Approach | Focuses on personalized care plans, clear communication, and a supportive patient experience. | Ensures patients feel informed, respected, and actively involved in their treatment journey. |
| Ethical Standards | Adheres to a strict code of medical ethics, ensuring transparency in billing and treatment recommendations. | Builds trust and confidence by upholding integrity in all medical practices. |
| Research and Development | Invests in ongoing medical education and potential participation in clinical research. | Stays at the forefront of medical advancements, offering patients access to innovative treatments. |
Key Credentials and Strengths of Franance Health
- International Accreditation and Certifications
- Highly Qualified and Experienced Medical Staff
- State-of-the-Art Medical Technology and Facilities
- Comprehensive Range of Specialized Medical Services
- Commitment to Patient Safety and Quality Assurance
- Strong Reputation and Patient Testimonials
- Ethical Medical Practices and Transparency
- Focus on Continuous Professional Development
Scope Of Work For Mri Rf Cage (Faraday Cage) Installation & Testing Service
This Scope of Work (SOW) outlines the requirements for the installation and testing of an MRI Radio Frequency (RF) Shielded Enclosure, commonly known as a Faraday Cage. The objective is to ensure the RF shielding integrity meets or exceeds industry standards for optimal MRI system performance and patient safety, preventing external RF interference from impacting image quality and internal RF emissions from escaping.
| Phase | Description | Key Activities | Deliverables |
|---|---|---|---|
| Site assessment, design verification, material procurement, and project scheduling. | Review architectural drawings, MRI equipment specifications, and site conditions. Confirm RF cage design and dimensions. Coordinate with site personnel regarding access, power, and ventilation. Order all necessary materials and components. Develop a detailed project schedule. | Site survey report. Verified RF cage design drawings. Procurement list. Approved project schedule. |
| Construction of the RF shielded enclosure, including structural components, door, window, power/data filtering, and ventilation. | Assemble and erect RF shielding panels (e.g., copper, aluminum, steel). Install RF gasketed door and RF shielded window. Install RF filters on all electrical conduits, data lines, and ventilation penetrations. Ensure proper grounding and bonding of all components. | Completed RF shielded enclosure structure. Installed and tested RF door and window. Installed and verified RF filters. Completed grounding and bonding system. |
| Comprehensive testing to measure the RF shielding effectiveness across specified frequency ranges. | Conduct pre-qualification testing (if required). Perform swept frequency testing to measure attenuation from 1 kHz to 10 GHz (or as per MRI manufacturer specifications). Conduct specialized tests for specific frequency bands critical for MRI operation. Document all test results with calibrated equipment. | RF shielding effectiveness test report. Certification of compliance with specified standards. Calibration certificates for testing equipment. |
| Post-installation inspection, system review, and project closure. | Conduct a final visual inspection of the installed RF cage. Review all installation and testing documentation with the client. Address any outstanding issues or punch list items. Provide comprehensive handover documentation. | Final project acceptance sign-off. Complete installation and testing documentation package. As-built drawings (if applicable). |
Key Objectives
- To professionally install a complete RF shielded enclosure designed for a specific MRI system.
- To meticulously test and certify the RF shielding effectiveness of the installed enclosure.
- To ensure all installation and testing procedures adhere to relevant industry standards and manufacturer specifications.
- To provide comprehensive documentation of the installation and testing process.
Service Level Agreement For Mri Rf Cage (Faraday Cage) Installation & Testing Service
This Service Level Agreement (SLA) outlines the response times and uptime guarantees for the MRI RF Cage (Faraday Cage) Installation & Testing Service provided by [Your Company Name] to [Client Name]. This SLA is an addendum to the Master Service Agreement (MSA) dated [Date of MSA].
| Service Category | Severity Level | Response Time (Business Hours) | Resolution Target (Business Hours) | Uptime Guarantee (RF Shielding Effectiveness) |
|---|---|---|---|---|
| Installation (New) | Standard | 24-48 hours for initial site assessment and scheduling | As per agreed project timeline | N/A (Service is performance-based) |
| Installation (New) | Expedited (e.g., critical project deadline) | 12-24 hours for initial site assessment and scheduling | As per agreed project timeline (with expedited provisions) | N/A (Service is performance-based) |
| Testing & Certification | Critical (e.g., scheduled MRI installation imminent, failed previous test) | 4 Business Hours | 24 Business Hours | N/A (Service is performance-based, but testing validates uptime) |
| Testing & Certification | Standard (e.g., routine certification, pre-installation check) | 8 Business Hours | 48 Business Hours | N/A (Service is performance-based, but testing validates uptime) |
| Troubleshooting & Repair | Critical (e.g., complete RF shielding failure impacting MRI operation) | 2 Business Hours | 8 Business Hours | Guaranteed minimum RF shielding effectiveness of [Specific dB Value, e.g., 100 dB] within the MRI room, with a target of [Higher dB Value, e.g., 120 dB] post-repair. |
| Troubleshooting & Repair | High (e.g., intermittent RF interference detected, minor shielding degradation) | 4 Business Hours | 24 Business Hours | Guaranteed minimum RF shielding effectiveness of [Specific dB Value, e.g., 100 dB] within the MRI room, with a target of [Higher dB Value, e.g., 120 dB] post-repair. |
| Troubleshooting & Repair | Medium (e.g., minor RF leakage identified, aesthetic issues affecting shielding) | 8 Business Hours | 72 Business Hours | Guaranteed minimum RF shielding effectiveness of [Specific dB Value, e.g., 100 dB] within the MRI room, with a target of [Higher dB Value, e.g., 120 dB] post-repair. |
| Preventative Maintenance | Scheduled | N/A (Service is scheduled proactively) | As per agreed maintenance schedule | Maintenance aims to preserve and ensure RF shielding effectiveness remains above [Specific dB Value, e.g., 100 dB]. |
Scope of Service
- Installation of new MRI RF Cages (Faraday Cages).
- Testing and certification of existing MRI RF Cages (Faraday Cages) for RF shielding effectiveness.
- Troubleshooting and repair of RF shielding integrity issues.
- Preventative maintenance for RF Cage components.