Background
Verified Service Provider in Ivory Coast

IEC 62353 Recurrent Test Service (In-Service Testing) in Ivory Coast Engineering Excellence & Technical Support

IEC 62353 Recurrent Test Service (In-Service Testing) High-standard technical execution following OEM protocols and local regulatory frameworks.

Talk To Sales

Enhanced Patient Safety & Compliance

Our IEC 62353 Recurrent Test Service in Ivory Coast ensures your medical equipment meets the latest international safety standards, minimizing risks to patients and healthcare professionals by verifying essential electrical safety parameters.

Optimized Equipment Performance & Lifespan

Through meticulous in-service testing and calibration according to IEC 62353, we identify and address potential performance degradations before they become critical, extending the operational life and reliability of your medical devices in Ivory Coast.

Streamlined Regulatory Adherence

Leverage our expert IEC 62353 recurrent testing to effortlessly comply with national healthcare regulations in Ivory Coast. We provide comprehensive documentation and reporting, simplifying audits and ensuring continuous operational readiness of your medical facility.

What Is Iec 62353 Recurrent Test Service (In-service Testing) In Ivory Coast?

IEC 62353, "Medical electrical equipment - Medical equipment in grounded equipment - Routine tests and tests after repair," establishes internationally recognized procedures for the recurrent testing (in-service testing) of medical electrical equipment. This standard aims to ensure the continued safety and operational integrity of medical devices once they are deployed in clinical environments. In Ivory Coast, as globally, the implementation of IEC 62353 recurrent test services is crucial for healthcare facilities to comply with regulatory requirements, mitigate patient and operator risks, and optimize equipment lifespan. These services are performed periodically, as specified by the standard and manufacturer recommendations, or after significant repairs or modifications to medical equipment.

Who Needs IEC 62353 Recurrent Test Service?Typical Use Cases/Equipment
Hospitals and Clinics: All healthcare facilities utilizing medical electrical equipment are obligated to ensure its ongoing safety.Diagnostic Imaging Equipment (X-ray, CT, MRI, Ultrasound)Therapeutic Equipment (Radiotherapy machines, Electrosurgical units, Ventilators)Patient Monitoring Systems (ECG monitors, Pulse oximeters)Laboratory Analyzers and EquipmentSurgical Equipment (Electrosurgical generators, Light sources)Anesthesia MachinesDefibrillatorsInfusion Pumps and Syringe DriversRehabilitation and Physiotherapy Equipment
Medical Device Manufacturers (for their service centers): To maintain product compliance and provide documented service.Third-Party Biomedical Engineering Service Providers: Offering specialized testing and maintenance services to healthcare institutions.Regulatory Bodies/Auditors: To verify compliance with national and international safety standards.

What IEC 62353 Recurrent Test Service Involves:

  • Visual Inspection: Thorough examination of the equipment for physical damage, wear and tear, proper labeling, and integrity of electrical connections.
  • Protective Earthing (Grounding) Test: Verification of the continuity and low resistance of the protective earth conductor to ensure effective fault current dissipation.
  • Enclosure Leakage Current Test: Measurement of the current that flows through the protective earth conductor under normal operating conditions.
  • Touch Current Test: Measurement of the current that can flow through a person in contact with accessible conductive parts of the equipment under normal and single-fault conditions.
  • Insulation Resistance Test: Assessment of the electrical insulation between conductive parts and between conductive parts and earth.
  • Functional Performance Tests: Verification of critical operational parameters to ensure the equipment functions as intended and safely.
  • Electrical Safety Parameter Tests: Comprehensive testing of various electrical safety aspects as defined in the standard, including capacitor discharge and insulation monitoring for specific equipment types.
  • Documentation and Reporting: Meticulous recording of all test results, equipment details, and remedial actions, often accompanied by a safety certificate.

Who Needs Iec 62353 Recurrent Test Service (In-service Testing) In Ivory Coast?

IEC 62353, also known as 'Medical electrical equipment - Routine checks and tests after repair of medical electrical equipment,' is a crucial international standard for ensuring the safety of medical devices currently in use. In Ivory Coast, as with any nation, maintaining the safety and reliability of medical equipment is paramount for patient care and the efficiency of healthcare facilities. The 'Recurrent Test Service' (also referred to as 'In-Service Testing') is the practical application of this standard to devices that have been in operation for a period or have undergone maintenance.

This service is essential for identifying and mitigating potential hazards that may arise from the normal use, aging, or repair of medical electrical equipment. It involves systematic checks and tests to verify that the device continues to meet the applicable safety requirements. The primary goal is to prevent harm to patients, users, and others by ensuring that the equipment is safe to operate in its intended environment.

Customer TypeReason for Needing IEC 62353 Recurrent TestingKey Departments Involved
Hospitals & Clinics (Public/Private)Ensuring patient and staff safety, compliance with national health regulations, risk management, operational efficiency, preventing equipment failure.Biomedical Engineering, Quality Assurance, Clinical Departments (nurses, doctors overseeing equipment use), Administration.
Diagnostic LaboratoriesMaintaining accuracy of diagnostic results, preventing errors due to faulty equipment, safeguarding personnel.Laboratory Management, Technical Staff, Biomedical Engineering (if applicable).
Medical Equipment Service Providers (Local Reps, 3rd Party)Fulfilling service contract obligations, maintaining reputation, ensuring equipment sold or serviced meets safety standards, avoiding liability.Technical Service Teams, Quality Control, Sales & Customer Service Departments.
Government Health AgenciesSetting and enforcing safety standards, overseeing the safety of public healthcare infrastructure, ensuring public trust in healthcare services.Regulatory Affairs, Technical Inspection Departments, Public Health Divisions.
Rehabilitation & Specialized CentersEnsuring the safety and effectiveness of equipment used for patient therapy and treatment, especially for vulnerable patient populations.Therapy Departments, Clinical Staff, Biomedical Engineering.

Who Needs IEC 62353 Recurrent Test Service in Ivory Coast? Target Customers and Departments:

  • {"items":["Public Hospitals and Clinics","Private Hospitals and Clinics","Diagnostic Laboratories","Rehabilitation Centers","Medical Imaging Centers","Dental Clinics","Specialized Medical Practices (e.g., Cardiology, Neurology, Oncology)","Medical Equipment Manufacturers' Local Representatives/Distributors (for devices under warranty or service contracts)","Third-Party Medical Equipment Maintenance and Repair Companies","Government Health Agencies and Regulatory Bodies overseeing healthcare infrastructure"],"title":"Target Customers"}
  • {"items":["Biomedical Engineering Department (or equivalent)","Clinical Engineering Department","Quality Assurance Department","Infection Control Department","Operating Theatres / Surgical Departments","Intensive Care Units (ICUs)","Emergency Departments","Radiology and Imaging Departments","Laboratories (Clinical, Pathology, etc.)","Pharmacy Departments (for specific equipment)","Rehabilitation and Physiotherapy Departments","Outpatient Clinics","Administrative departments responsible for asset management and compliance"],"title":"Target Departments within Healthcare Facilities"}

Iec 62353 Recurrent Test Service (In-service Testing) Process In Ivory Coast

The IEC 62353 recurrent test service, also known as in-service testing, is crucial for ensuring the safety and functionality of medical electrical equipment in Ivory Coast. This process guarantees that devices continue to meet safety standards after deployment and regular use. The workflow from inquiry to execution typically involves several key stages, facilitated by accredited testing laboratories or service providers.

Workflow Stages:

  1. Inquiry and Request for Quotation (RFQ): The process begins when a healthcare facility (hospital, clinic, laboratory) or equipment manufacturer in Ivory Coast identifies a need for recurrent testing of their medical electrical equipment. They will contact a qualified testing service provider with an inquiry. This inquiry typically includes details about the equipment to be tested (type, model, serial number, quantity), the desired testing timeframe, and any specific requirements. The service provider then issues a Request for Quotation (RFQ) based on this information.
  1. Quotation and Agreement: The service provider provides a detailed quotation outlining the scope of work, testing procedures (referencing IEC 62353), estimated timeline, personnel involved, and associated costs. Upon review and acceptance of the quotation by the client, a formal service agreement or contract is established, detailing terms, conditions, and responsibilities.
  1. Planning and Scheduling: Once the agreement is in place, the service provider works with the client to plan and schedule the testing. This involves coordinating access to the equipment, ensuring it is available for testing during the designated period, and confirming the testing location (on-site at the healthcare facility or at the service provider's lab).
  1. Pre-Test Preparation: Before the actual testing begins, the client may be required to provide certain documentation, such as the equipment's user manual, previous test reports, and maintenance logs. The service provider will ensure they have the necessary calibrated testing equipment and qualified personnel ready for the task.
  1. Execution of Tests (IEC 62353 Compliance): The core of the service is the execution of tests as per the IEC 62353 standard. This includes a series of electrical safety tests, such as:
*   **Protective Earthing Resistance:** Verifies the integrity of the protective earth connection.
*   **Enclosure Leakage Current:** Measures the current that flows through the protective earth conductor under normal and single-fault conditions.
*   **Patient Leakage Current (Direct and Indirect Contact):** Assesses the current that can pass through a patient in contact with accessible parts, under normal and single-fault conditions.
*   **Touch Current:** Measures the current that can flow through a person touching accessible conductive parts.
*   **Functional Tests:** Ensures the equipment operates as intended and that safety mechanisms are not compromised by its function.
*   **Visual Inspection:** Checks for any physical damage or wear and tear.
*   **Software Validation (if applicable):** Verifies the integrity and safety of the equipment's software.
  1. Data Recording and Analysis: Throughout the testing process, all measured values and observations are meticulously recorded by the testing technician. This data is then analyzed to determine if the equipment meets the acceptance criteria defined by IEC 62353.
  1. Reporting: A comprehensive test report is generated, detailing the equipment tested, the tests performed, the results obtained (including pass/fail status for each test), the calibration status of the testing equipment, and the qualifications of the personnel who conducted the tests. The report will also include recommendations for any corrective actions if the equipment fails to meet the required standards.
  1. Issuance of Certificate/Report: Upon successful completion of the tests and review of the report, the service provider issues a compliance certificate or a signed test report to the client, confirming that the medical electrical equipment has undergone recurrent testing according to IEC 62353 and is deemed safe for continued use. If corrective actions are required, a follow-up re-test may be necessary after repairs.
  1. Follow-up and Records Management: The client retains the test reports for their records and for future reference. The service provider also maintains their own records for audit purposes and to track the history of tested equipment. The client is responsible for scheduling future recurrent tests as per the recommended intervals.
StageDescriptionKey Activities
Inquiry & RFQClient identifies testing need and requests a quote.Contacting service provider, providing equipment details.
Quotation & AgreementService provider submits a detailed quote and contract is finalized.Reviewing quote, signing service agreement.
Planning & SchedulingCoordinating test dates and locations with the client.Confirming access, equipment availability, testing site.
Pre-Test PreparationEnsuring all necessary documentation and equipment are ready.Gathering manuals, previous reports; calibrating test equipment.
Execution of TestsConducting electrical safety and functional tests per IEC 62353.Performing earth resistance, leakage current, touch current, functional tests.
Data Recording & AnalysisDocumenting all test results and assessing against standards.Recording measurements, comparing against acceptance criteria.
ReportingCompiling a comprehensive report of findings and recommendations.Generating detailed test report with pass/fail status.
Certificate/Report IssuanceProviding official documentation of successful testing.Issuing compliance certificate or signed report.
Follow-up & RecordsClient maintains records, service provider manages history.Storing reports, scheduling future tests.

Key Stages in IEC 62353 Recurrent Test Service in Ivory Coast

  • Inquiry and Request for Quotation (RFQ)
  • Quotation and Agreement
  • Planning and Scheduling
  • Pre-Test Preparation
  • Execution of Tests (IEC 62353 Compliance)
  • Data Recording and Analysis
  • Reporting
  • Issuance of Certificate/Report
  • Follow-up and Records Management

Iec 62353 Recurrent Test Service (In-service Testing) Cost In Ivory Coast

The cost of IEC 62353 recurrent testing services (in-service testing) in Ivory Coast can vary significantly based on several factors. This standard, also known as 'Medical electrical equipment - Routine checks and measurements', is crucial for ensuring the safety and performance of medical devices after they have been put into service. Local service providers, calibration laboratories, and specialized biomedical engineering firms offer these services. The pricing is influenced by the complexity of the medical device, the number of devices to be tested, the location of the testing (on-site vs. in-lab), the urgency of the service, and the reputation and accreditation of the service provider.

Device Category (Example)Estimated Cost Range (XOF - CFA Francs)Notes
Basic Diagnostic Equipment (e.g., ECG, Blood Pressure Monitor)30,000 - 75,000Per device. Simpler tests.
Therapeutic Devices (e.g., Infusion Pumps, Ventilators - basic)50,000 - 120,000Per device. More complex parameters to test.
Imaging Equipment (e.g., X-ray, Ultrasound - smaller units)100,000 - 250,000Per device. Requires specialized equipment and potentially longer testing times.
Complex Life-Support/Monitoring Systems (e.g., Anesthesia Machines, ICU Ventilators)150,000 - 500,000+Per device. Highly complex, extensive testing, specialized knowledge needed.
Large Imaging Equipment (e.g., MRI, CT Scanners)300,000 - 1,000,000+Per device. Significant technical expertise, specialized equipment, and time intensive.
Bulk Testing DiscountNegotiable (typically 10-25% off per-unit cost)Applies when testing a significant number of similar devices.
On-site Visit Surcharge20,000 - 50,000+Per visit, depending on distance and technician time.

Factors Influencing IEC 62353 Recurrent Test Costs in Ivory Coast

  • Type and Complexity of Medical Device: Testing requirements and time vary greatly depending on whether it's a simple defibrillator or a complex MRI machine.
  • Number of Devices: Bulk testing often comes with discounted per-unit pricing.
  • On-site vs. In-Lab Testing: On-site testing incurs additional costs for travel, accommodation (if applicable), and technician time.
  • Urgency of Service: Expedited testing services will typically command higher fees.
  • Service Provider's Reputation and Accreditation: Established and accredited providers may charge more due to their expertise and certified processes.
  • Geographical Location within Ivory Coast: Testing in major cities like Abidjan might have different pricing than in more remote areas due to logistical considerations.
  • Scope of Testing: The specific tests performed as per IEC 62353 can influence the overall cost.
  • Calibration and Maintenance Services Bundled: If the recurrent testing is part of a larger maintenance contract, the pricing structure will differ.

Affordable Iec 62353 Recurrent Test Service (In-service Testing) Options

Ensuring medical equipment is safe and compliant with IEC 62353 (Medical electrical equipment - Routine checks and tests during maintenance of medical electrical equipment) is crucial for patient safety and operational continuity. Regular recurrent testing, also known as in-service testing, helps identify potential hazards before they impact patient care. This document outlines affordable options for IEC 62353 recurrent testing services, focusing on value bundles and cost-saving strategies for healthcare facilities.

Value Bundle OptionDescriptionKey FeaturesEstimated Cost Range (per device/annually)Cost-Saving Strategy
Basic Compliance PackageCovers essential IEC 62353 tests for a defined set of equipment.Annual testing, basic reporting, calibration of test equipment.$50 - $150Bundle larger quantities of the same equipment type for volume discounts. Schedule testing during off-peak hours.
Comprehensive Safety BundleIncludes all basic tests plus more in-depth functional assessments and extended reporting.Annual testing, detailed reports with historical data, minor repair recommendations.$100 - $250Opt for multi-year contracts. Combine with other service needs like equipment calibration.
Preventative Maintenance & Safety BundleIntegrates IEC 62353 testing with scheduled preventative maintenance tasks.Semi-annual or annual testing and PM, full equipment diagnostics, battery health checks.$150 - $300+Leverage existing PM schedules. Negotiate bundled pricing for different equipment categories. Explore in-house training for basic checks to reduce outsourced services.
On-Demand & Critical Equipment FocusPrioritizes testing for high-risk or frequently used equipment with flexible scheduling.As-needed testing, rush service options, priority reporting for critical equipment.Variable (per service call)Invest in a basic in-house testing kit for minor equipment. Establish clear criteria for 'critical' equipment to optimize service calls.
Remote Monitoring & Predictive Analysis (Emerging)Utilizes technology for continuous or frequent monitoring, reducing the need for physical on-site testing.Real-time data collection, anomaly detection, predictive maintenance alerts, limited on-site verification.Subscription-based, potentially higher initial setup cost but lower recurring cost per device.Focus on high-value, high-risk equipment for initial implementation. Analyze ROI based on reduced downtime and failure rates.

Understanding IEC 62353 Recurrent Testing

  • Purpose: To verify the safety of medical electrical equipment after maintenance, repair, or at regular intervals.
  • Key Tests: Includes visual inspection, protective earthing continuity, insulation resistance, touch current (earth leakage, enclosure leakage, patient leakage), and functional tests.
  • Frequency: Determined by manufacturer recommendations, regulatory requirements, and risk assessment.
  • Benefits: Enhances patient safety, reduces risk of equipment failure, ensures regulatory compliance, and supports efficient maintenance programs.

Verified Providers In Ivory Coast

In the Ivory Coast's evolving healthcare landscape, identifying reliable and credentialed providers is paramount for individuals and organizations seeking quality medical services. Franance Health stands out as a leading force, meticulously vetting and certifying healthcare professionals and facilities. This rigorous credentialing process ensures that all Franance Health verified providers meet stringent standards of expertise, ethics, and patient care, offering unparalleled peace of mind to their clientele. Choosing a Franance Health verified provider means opting for a healthcare experience defined by professionalism, safety, and efficacy. Their commitment to maintaining a network of the highest caliber professionals makes them the undisputed best choice for all your health needs in Ivory Coast.

Provider TypeKey Verification CriteriaBenefits of Franance Health Verification
Hospitals and ClinicsAccreditation, infrastructure, medical equipment, hygiene standards, staff qualificationsAccess to state-of-the-art facilities, assurance of safe and effective treatment environments.
Specialist PhysiciansMedical board certification, years of practice, patient reviews, specialized trainingExpert medical advice and treatment from highly qualified specialists.
General PractitionersMedical license, continuous professional development, patient feedbackReliable primary care services and ongoing health management.
Diagnostic LaboratoriesLicensing, equipment calibration, quality control measures, technologist qualificationsAccurate and dependable diagnostic test results for informed medical decisions.
PharmaciesPharmacy license, drug dispensing protocols, pharmacist qualifications, inventory managementSafe and reliable access to essential medications and professional pharmaceutical advice.

Why Franance Health Credentials Represent the Best Choice:

  • Rigorous Vetting Process: Franance Health employs a comprehensive evaluation of healthcare providers' qualifications, experience, and adherence to best practices.
  • Commitment to Quality Care: Verified providers are committed to delivering high-quality, patient-centered medical services.
  • Enhanced Patient Safety: The credentialing process prioritizes patient safety through thorough background checks and verification of medical licenses.
  • Ethical Standards: Franance Health ensures that its verified providers uphold the highest ethical standards in their practice.
  • Access to Expertise: Clients gain access to a network of highly skilled and specialized medical professionals.
  • Trust and Reliability: Franance Health verification offers a mark of trust, assuring clients of reliable and competent healthcare services.

Scope Of Work For Iec 62353 Recurrent Test Service (In-service Testing)

This Scope of Work (SOW) outlines the requirements for providing recurrent in-service testing (IST) of medical electrical equipment (MEE) in accordance with the IEC 62353 standard. The service aims to ensure the continued safety and performance of MEE within a healthcare facility. This document details the technical deliverables, standard specifications, and the overall scope of the testing service.

CategoryStandard SpecificationDescriptionDeliverable
General RequirementsIEC 62353Applies to the recurrent testing of MEE after initial acceptance testing and in the course of normal use. It specifies tests to verify electrical, mechanical, and functional safety. Covers test procedures, measurement techniques, and acceptable limits.Test Report conforming to IEC 62353 (see below).
Visual InspectionIEC 62353 - Clause 5Physical examination of the MEE, including cables, connectors, housings, controls, and any accessories, for signs of damage, wear, or deterioration.Detailed record of visual inspection findings, including photographs of any defects.
Protective Earthing (Grounding) ResistanceIEC 62353 - Clause 6.1Measurement of the resistance of the protective earth connection between accessible conductive parts and the earth terminal of the mains plug or equivalent.Measured resistance value (Ohms) and comparison to specified limits (e.g., < 0.3 Ohms for single-fault conditions).
Enclosure Leakage CurrentIEC 62353 - Clause 6.2Measurement of leakage current flowing through the protective earth to the chassis when the equipment is connected to the mains supply. This tests the integrity of the protective earthing.Measured leakage current (mA) and comparison to specified limits (e.g., < 10 mA for Class I MEE).
Touch CurrentIEC 62353 - Clause 6.3Measurement of current that passes through a patient or operator when they touch accessible conductive parts of the MEE under normal and single-fault conditions. Differentiates between patient and applied part leakage currents.Measured touch current values (mA) under various conditions and comparison to specified limits (e.g., < 0.1 mA for patient leakage current, < 0.5 mA for operator touch current).
Insulation ResistanceIEC 62353 - Clause 6.4Measurement of the resistance between conductive parts that are separated by insulation. This verifies the integrity of the electrical insulation.Measured insulation resistance (MegaOhms) and comparison to specified limits (e.g., > 2 MOhms).
Functional TestsIEC 62353 - Clause 7Verification of the MEE's intended functions as per manufacturer's specifications. This may include operational checks, parameter verification, and alarm system functionality.Confirmation that the MEE performs its intended functions safely and accurately.
Mechanical SafetyIEC 62353 - Clause 8Assessment of mechanical integrity, including stability, moving parts, sharpness of edges, and secure fastening of components.Confirmation of mechanical safety features and absence of mechanical hazards.
Software Verification (if applicable)IEC 62353 - Annex DFor MEE with embedded software, verification of critical software functions, update integrity, and absence of known vulnerabilities that could compromise safety.Confirmation of software integrity and functional safety.
DocumentationIEC 62353Comprehensive documentation of all tests performed, results obtained, any identified deviations from standards, and recommended actions. Includes unique identification of each tested device.A detailed Test Report for each MEE tested, including a certificate of compliance (if applicable) and a list of actions required for non-compliant devices.
Test EquipmentIEC 62353 - Clause 4.1All test equipment used must be calibrated and traceable to national or international standards.Confirmation of calibrated test equipment usage.

Key Objectives of IEC 62353 Recurrent Test Service

  • Verification of electrical safety of MEE.
  • Assessment of mechanical and functional safety.
  • Identification of potential hazards arising from aging, wear, or damage.
  • Ensuring compliance with current safety standards and regulations.
  • Providing a documented record of the safety status of MEE.
  • Minimizing patient and operator risk associated with MEE use.

Service Level Agreement For Iec 62353 Recurrent Test Service (In-service Testing)

This Service Level Agreement (SLA) outlines the guaranteed response times and uptime for the IEC 62353 Recurrent Test Service (In-Service Testing). This service is designed to ensure that medical devices are tested and maintained in accordance with the IEC 62353 standard, guaranteeing their safety and operational integrity during their service life.

Service ComponentUptime GuaranteeResponse Time Guarantee (Critical Incident)Response Time Guarantee (Non-Critical Incident)Response Time Guarantee (New Device Testing Request)
IEC 62353 Recurrent Test Service Availability99.5% (excluding Scheduled Maintenance Windows)N/AN/AN/A
Incident Support (Critical)N/A2 Business HoursN/AN/A
Incident Support (Non-Critical)N/AN/A4 Business HoursN/A
Service Scheduling and ExecutionN/AN/AN/AWithin 5 Business Days of request, subject to availability and Scheduled Maintenance Windows.

Definitions

  • Service: IEC 62353 Recurrent Test Service (In-Service Testing) provided by [Your Company Name].
  • Customer: The entity that has subscribed to the Service.
  • Device: A medical device requiring recurrent testing as per IEC 62353.
  • Scheduled Maintenance Window: Pre-defined periods agreed upon with the Customer for performing recurrent tests to minimize disruption to operations.
  • Critical Incident: An event where a tested Device fails to meet the safety requirements of IEC 62353, posing an immediate risk to patient or user safety.
  • Non-Critical Incident: An event where a tested Device exhibits performance degradation or minor non-compliance that does not immediately pose a safety risk, but requires attention.
  • Response Time: The time taken from the Customer reporting an incident or requesting a service to the initiation of troubleshooting or scheduling of the service by [Your Company Name].
  • Uptime: The percentage of time the Service is available for scheduling and execution of recurrent tests, excluding Scheduled Maintenance Windows and Force Majeure events.
  • Force Majeure: Events beyond the reasonable control of [Your Company Name], including but not limited to natural disasters, acts of war, terrorism, widespread power outages, or pandemics.
In-Depth Guidance

Frequently Asked Questions

Background
Phase 02: Execution

Ready when you are

Let's scope your IEC 62353 Recurrent Test Service (In-Service Testing) in Ivory Coast project in Ivory Coast.

Speak to Sales