
Microbiology Safety Cabinet (Class II) in Guinea-Bissau
Leading Microbiology Safety Cabinet (Class II) Supplier
Buy Microbiology Safety Cabinet (Class II) in Guinea-Bissau. Top suppliers, installation, and warranty from Franance Health. Get a quote today.
Enhanced Biosafety
Provides superior protection for personnel, product, and environment against hazardous microorganisms.
Controlled Airflow
Features HEPA filtered laminar airflow to maintain sterile conditions and prevent cross-contamination.
Robust Construction
Built with durable materials for reliable and long-lasting performance in laboratory settings.
What Is A Microbiology Safety Cabinet (Class Ii)?
A Microbiology Safety Cabinet (Class II) is a vital piece of laboratory equipment designed to provide a sterile working environment for handling infectious agents and ensuring the safety of both the user and the surrounding environment. It achieves this through a sophisticated system of airflow and HEPA filtration. Class II cabinets are the most common type used in clinical microbiology laboratories, offering personnel protection, product protection (preventing contamination of samples), and environmental protection. This is accomplished by drawing air from the laboratory into the cabinet, passing it through a HEPA filter to sterilize it, and then recirculating a portion back into the workspace while exhausting the remainder, also HEPA-filtered, to the outside.
| Feature | Benefit |
|---|---|
| HEPA Filtration | Removes airborne microorganisms and particles, ensuring sterile workspace and preventing cross-contamination. |
| Downflow Airflow | Creates a laminar, sterile barrier over the work surface, protecting the product from external contamination. |
| Inward Airflow | Draws unfiltered air into the cabinet, protecting the operator from exposure to hazardous agents. |
| Exhaust Filtration | Filters expelled air before it is released, safeguarding the laboratory environment. |
Key Clinical Applications:
- Safe manipulation of cultures for bacterial, viral, and fungal identification.
- Preparation of diagnostic specimens, such as blood, urine, and cerebrospinal fluid.
- Performing molecular diagnostic tests, including PCR and nucleic acid amplification.
- Handling of antibiotic susceptibility testing.
- Aseptic techniques for cell culture and tissue culture procedures.
- Working with potentially infectious aerosols generated during sample processing.
Who Needs Microbiology Safety Cabinet (Class Ii) In Guinea-bissau?
In Guinea-Bissau, the implementation of Class II Microbiology Safety Cabinets is crucial for a range of healthcare and research facilities dedicated to safeguarding personnel, the environment, and patient samples from biological agents. These advanced containment systems are particularly vital in settings where infectious diseases are prevalent and diagnostic accuracy is paramount.
| Department/Function | Primary Need for Class II Cabinet |
|---|---|
| Microbiology & Infectious Disease Labs | Containment of airborne particles from pathogenic microorganisms during culturing, sample processing, and testing. |
| Virology Labs | Safe manipulation of viruses, including those requiring Biosafety Level 2 (BSL-2) or BSL-3 containment. |
| Pathology & Histopathology | Handling of tissue samples potentially contaminated with infectious agents. |
| Diagnostic Serology | Safe processing of patient sera for antibody detection, especially when dealing with unknown infectious agents. |
| Molecular Diagnostics (PCR, etc.) | Preventing contamination of samples and amplification products, and protecting personnel from aerosols generated during sample preparation. |
| Outbreak Investigation Teams | Field or laboratory-based analysis of samples collected during disease outbreaks to identify causative agents safely. |
Key Facility Types and Departments Requiring Class II Cabinets:
- Central and Regional Hospitals: Especially those with dedicated infectious disease units, pathology departments, and microbiology laboratories, which handle a high volume of potentially hazardous specimens.
- Teaching Hospitals and Medical Universities: For training medical professionals and conducting research in microbiology, virology, and infectious diseases, ensuring student and researcher safety.
- Public Health Laboratories: Crucial for national disease surveillance, outbreak investigation, and the identification of pathogens, requiring stringent biosafety measures.
- Diagnostic Laboratories (Private and Public): Performing routine and specialized microbiological testing, including cultures, serology, and molecular diagnostics for infectious agents.
- Research Institutions and Centers: Involved in the study of endemic and emerging infectious diseases, requiring controlled environments for sample handling and experimentation.
- Blood Banks and Transfusion Services: For screening donated blood for transmissible infectious agents, mitigating risks to recipients.
- Veterinary Laboratories: Particularly those involved in zoonotic disease surveillance and research, as many infectious diseases can transmit between animals and humans.
Installation Process For Microbiology Safety Cabinet (Class Ii)
Ensuring the proper installation of your Class II Microbiology Safety Cabinet is paramount for safeguarding personnel, products, and the environment in your Guinea-Bissau laboratory. Our specialized installation service guarantees that your equipment is set up correctly and adheres to all relevant safety and performance standards. We handle the entire process, from initial site assessment to final calibration, providing a seamless and efficient experience for your facility.
Site Preparation: Before delivery, a dedicated site assessment will be conducted by our qualified technicians. This involves evaluating the designated installation area to confirm adequate space, appropriate ventilation, access to stable power outlets (with surge protection recommended), and a level, robust surface capable of supporting the cabinet's weight. We will also identify the best location for exhaust ducting if required by your specific model and local regulations. Clear pathways for delivery must be ensured, free from obstructions.
Delivery: Upon confirmation of site readiness, your Class II Microbiology Safety Cabinet will be transported by our trained logistics team. We take extreme care to protect the unit during transit, utilizing specialized packaging and handling equipment to prevent any damage. Our delivery personnel will position the cabinet in the prepared installation area, ready for the next stage.
Installation Steps: Our certified technicians will then proceed with the professional installation. This typically includes:
- Unpacking and meticulous inspection of the cabinet for any visible signs of damage.
- Assembly of any modular components.
- Secure positioning and leveling of the cabinet.
- Connection to the building's exhaust system (if applicable and pre-arranged), ensuring leak-free and compliant ducting.
- Electrical connection to a dedicated, properly grounded power source.
- Initial power-up and system checks to verify basic functionality.
Calibration Requirements: Post-installation, a comprehensive calibration is essential to confirm the cabinet's performance and safety. This includes:
- Airflow Velocity Measurements: Verifying both the downflow and inflow air velocities meet the specified standards (e.g., ISO 14644-1, NSF/ANSI 49).
- HEPA Filter Integrity Testing (Leak Testing): Performing a scan test on the HEPA filters to ensure they are properly sealed and free from leaks.
- Face Velocity Uniformity Tests: Confirming consistent airflow across the work surface.
- Alarms and Interlocks Verification: Testing all safety alarms, such as airflow deviation warnings and UV sterilization timers.
Our calibration services are performed using certified, traceable equipment, and a detailed report will be provided, documenting all test results and confirming the cabinet's compliance. Regular recalibration is strongly recommended to maintain optimal performance and safety throughout the equipment's lifespan.
| Calibration Parameter | Standard/Requirement (Typical) | Verification Method |
|---|---|---|
| Downflow Velocity | 0.3 - 0.5 m/s (60-100 fpm) | Anemometer (Hot-wire or Vane) |
| Inflow Velocity | 0.4 - 0.6 m/s (80-120 fpm) | Anemometer (Hot-wire or Vane) |
| HEPA Filter Integrity | 99.97% efficiency for 0.3 micron particles | DOP/PAO Leak Test (Scan Test) |
| Airflow Uniformity | Within +/- 20% of average | Anemometer array or smoke test |
Key Installation Considerations
- Adequate space and access for delivery and installation.
- Stable, level, and load-bearing installation surface.
- Proximity to suitable, grounded electrical outlets.
- Compliance with local building and ventilation codes for exhaust systems.
- Clear communication with our installation team regarding site specifics.
How Much Is A Microbiology Safety Cabinet (Class Ii) In Guinea-bissau?
The investment in a Class II Microbiology Safety Cabinet in Guinea-Bissau can vary significantly based on several factors, including whether you opt for a brand-new unit or a carefully refurbished model, as well as the specific features and manufacturer. While precise pricing can fluctuate due to import costs, currency exchange rates, and available stock, we can provide a realistic overview of the potential price ranges in local currency.
For new Class II Microbiology Safety Cabinets, expect a substantial investment. These units offer the latest technology, full manufacturer warranties, and guaranteed performance standards. Prices typically range from 1,500,000 XOF to 4,500,000 XOF or more. This range accounts for differences in size, filtration systems (HEPA vs. ULPA), airflow configurations (Type A1, A2, B1, B2), and integrated features.
Opting for a refurbished Class II Microbiology Safety Cabinet can offer a more budget-friendly solution without compromising on essential safety features. Reputable suppliers often source high-quality used equipment, thoroughly inspect it, perform necessary maintenance and upgrades, and ensure it meets operational standards. Refurbished units are generally priced between 750,000 XOF and 2,000,000 XOF. It's crucial to inquire about the extent of the refurbishment process, any remaining warranty, and the service history of the unit.
When budgeting, also consider potential additional costs such as delivery, installation, commissioning by a qualified technician, and ongoing maintenance and filter replacement, which are essential for maintaining the integrity and performance of the safety cabinet.
| Cabinet Type | Estimated Price Range (XOF) |
|---|---|
| New Class II Microbiology Safety Cabinet | 1,500,000 - 4,500,000+ |
| Refurbished Class II Microbiology Safety Cabinet | 750,000 - 2,000,000 |
Factors Influencing Price:
- New vs. Refurbished Condition
- Brand and Manufacturer Reputation
- Cabinet Size and Capacity
- Filtration Technology (HEPA/ULPA)
- Airflow Configuration (Type A1, A2, B1, B2)
- Additional Features (e.g., UV sterilization, specialized gas outlets)
- Import Duties and Taxes
- Supplier and Warranty Offered
Affordable Microbiology Safety Cabinet (Class Ii) Options
Understanding the budgetary constraints faced by healthcare facilities in Guinea-Bissau, we offer a range of cost-effective Class II Microbiology Safety Cabinets designed to meet essential safety standards without compromising on critical protection. Our value-focused options ensure that even with limited resources, laboratories can establish a secure environment for handling infectious agents and protecting personnel and the surrounding environment.
| Option | Key Benefit | Ideal For |
|---|---|---|
| Refurbished Units | Significant cost savings with certified quality and performance | Facilities seeking reliable biosafety at a lower initial investment. |
| Demo Models | Latest features and technology at a reduced price | Laboratories prioritizing modern functionality and aesthetics with budget considerations. |
| Entry-Level Systems | Essential biosafety protection at the most affordable price | Start-up labs, basic research facilities, and educational institutions with limited budgets. |
Explore Our Budget-Friendly Solutions:
- Refurbished Microbiology Safety Cabinets: Invest in high-quality, pre-owned Class II cabinets that have been meticulously inspected, serviced, and certified by our expert technicians. These units offer significant cost savings while still providing reliable performance and meeting stringent safety specifications.
- Demonstration (Demo) Models: Gain access to near-new, state-of-the-art Class II safety cabinets that have been used only for demonstration purposes. These models represent excellent value, offering the latest features and technology at a reduced price point.
- Entry-Level Systems: For foundational needs, our selection of entry-level Class II Microbiology Safety Cabinets provides robust protection and essential functionality at the most accessible price. These systems are ideal for laboratories requiring fundamental biosafety measures for common microbiological work.
Verified Microbiology Safety Cabinet (Class Ii) Suppliers In Guinea-bissau
Navigating the procurement of critical laboratory equipment like Class II Microbiology Safety Cabinets in Guinea-Bissau requires trust and proven reliability. Franance Health stands out as a premier supplier, dedicated to ensuring your research and diagnostic facilities are equipped with the highest standards of biosafety.
When you choose Franance Health for your Class II Microbiology Safety Cabinet needs in Guinea-Bissau, you benefit from a strategic approach that prioritizes your operational success and safety:
Why Partner with Franance Health?
- Exclusive OEM Partnerships: We maintain strong, direct relationships with leading original equipment manufacturers (OEMs) of Class II Microbiology Safety Cabinets. This ensures you receive genuine, certified equipment backed by the manufacturer's commitment to quality and performance. Our OEM partnerships allow us to offer the latest models and guarantee the integrity of every unit we supply.
- Dedicated Local Engineering Team: Understanding the unique logistical and technical landscape of Guinea-Bissau, Franance Health is proud to have a skilled local engineering team. This team is readily available for on-site installation, comprehensive training, and prompt technical support. They are equipped to address any operational challenges, ensuring your safety cabinets are always functioning at optimal levels and meet all local regulatory requirements.
- Robust Warranty and Support: We stand behind the quality of our products and services. Every Class II Microbiology Safety Cabinet procured through Franance Health comes with a comprehensive warranty. Beyond the warranty period, our commitment extends to providing ongoing maintenance and readily available spare parts, ensuring the longevity and uninterrupted performance of your essential biosafety equipment.
Standard Configuration & Accessories
Our Class II Microbiology Safety Cabinets are delivered with a comprehensive standard configuration designed for immediate deployment and optimal laboratory performance. Each unit is meticulously inspected and tested to ensure it meets the highest safety and functionality standards. While specific configurations can be tailored to your laboratory's unique requirements, the standard package typically includes:
| Optional Accessory | Description | Relevance for Guinea-Bissau Laboratories |
|---|---|---|
| Uninterruptible Power Supply (UPS) | Provides stable power during short outages, protecting sensitive equipment and data. | Crucial for maintaining continuous operation and preventing sample loss in regions with intermittent power supply. |
| Additional HEPA Filters | Replacement filters for long-term maintenance of air purity. | Ensures sustained operational efficiency and adherence to microbiological safety standards over time. |
| Workstation Enhancements (e.g., integrated socket strips) | Additional electrical outlets within the cabinet for powering external devices. | Convenient for users needing to connect multiple instruments or analytical tools. |
| Specific Gas Outlets (e.g., Nitrogen, CO2) | Fitted ports for specialized gas supplies required for certain microbiological procedures. | Essential for advanced research or diagnostic protocols that necessitate controlled atmospheric conditions. |
Standard Inclusions:
- Main cabinet unit with integrated blower and filtration system (HEPA filters)
- Pre-installed UV germicidal lamp for surface disinfection
- Adjustable front sash with tempered safety glass and ergonomic lifting mechanism
- Work surface made of high-grade stainless steel for easy cleaning and chemical resistance
- Built-in fluorescent lighting for excellent illumination of the work area
- Service outlets for gas or vacuum (as per specified model)
- Power cord and basic user manual
Warranty & Maintenance Plans
We understand the critical role of your Microbiology Safety Cabinet (Class II) in ensuring laboratory safety and integrity. To support your operations in Guinea-Bissau, we offer comprehensive warranty and maintenance plans designed for reliability and peace of mind. Our standard warranty covers manufacturing defects and component failures for a period of 12 months from the date of installation. Beyond this initial period, we provide flexible Extended Warranty options to ensure continued protection. To maximize the performance and lifespan of your Class II cabinet, we strongly recommend our Preventive Maintenance (PPM) plans. These scheduled services are conducted by certified technicians who perform thorough inspections, calibration, filter integrity testing, and cleaning, adhering to international safety standards. Furthermore, we maintain a robust inventory of genuine spare parts specifically for our Microbiology Safety Cabinets to minimize downtime in the unlikely event of a component failure. Our dedicated support team is readily available to assist with any service requests or inquiries.
| Service Type | Description | Frequency (Recommended) |
|---|---|---|
| Standard Warranty | Covers manufacturing defects and component failures. | 12 months from installation |
| Preventive Maintenance (PPM) | Comprehensive inspection, calibration, filter testing, and cleaning. | Annually (or bi-annually based on usage and environment) |
| Extended Warranty | Post-standard warranty coverage for continued protection. | Variable terms available |
| Spare Parts Availability | Access to genuine, manufacturer-approved components. | In-stock for common wear and tear items and critical components |
Key Features of Our Maintenance Plans:
- Scheduled Preventive Maintenance visits tailored to your usage.
- Performance verification and calibration by certified engineers.
- HEPA filter integrity testing and replacement.
- Priority access to genuine spare parts.
- Remote diagnostic support where applicable.
- Emergency service response options.
Frequently Asked Questions

Ready whenever you are
Let's discuss your Microbiology Safety Cabinet (Class II) in Guinea-Bissau requirements in Guinea-Bissau.
Scaling healthcare logistics and technical systems across the entire continent.

