C-Arm/Fluoroscopy Image Chain Repair Service in Gambia
Engineering Excellence & Technical Support
C-Arm/Fluoroscopy Image Chain Repair Service High-standard technical execution following OEM protocols and local regulatory frameworks.
Advanced Component-Level Repair
We specialize in intricate component-level diagnostics and repairs for C-arm and fluoroscopy image intensifiers and detectors. Our expert technicians utilize specialized tools and schematics to restore critical imaging components, ensuring optimal image quality and diagnostic accuracy for Gambian healthcare facilities.
X-Ray Tube & Generator Expertise
Our service addresses common issues with X-ray tubes and high-voltage generators, critical for fluoroscopic imaging. We provide thorough calibration and repair, guaranteeing consistent radiation output and image stability, crucial for safe and effective patient procedures in Gambia.
Integrated Image Chain Diagnostics
We offer comprehensive troubleshooting and repair of the entire C-arm image chain, from image acquisition hardware to display monitors. Our integrated approach ensures all components work harmoniously, minimizing downtime and restoring full diagnostic capability for medical imaging in The Gambia.
What Is C-arm/fluoroscopy Image Chain Repair Service In Gambia?
C-Arm/Fluoroscopy Image Chain Repair Service in Gambia refers to the specialized maintenance and restoration of the imaging components within a C-arm fluoroscopy system. This service is crucial for ensuring the optimal functionality and diagnostic accuracy of these medical imaging devices. The 'image chain' encompasses all elements responsible for generating, processing, and displaying the fluoroscopic image, including the X-ray generator, image intensifier or flat-panel detector, video camera or digital acquisition system, and associated signal processing hardware and software. Repair services address issues such as image degradation, signal loss, component failure, calibration drift, and system errors that impede diagnostic imaging capabilities. This maintenance is essential for healthcare facilities in Gambia utilizing C-arm fluoroscopy for various interventional and diagnostic procedures.
| Who Needs C-Arm/Fluoroscopy Image Chain Repair Service? | Typical Use Cases for C-Arm Fluoroscopy Requiring Image Chain Integrity | |||||
|---|---|---|---|---|---|---|
| Hospitals and Clinics in Gambia equipped with C-arm fluoroscopy systems. | Orthopedic Surgery: Intraoperative guidance for fracture reduction, hardware placement (screws, plates, rods), and joint replacement procedures. | Cardiology: Percutaneous Coronary Interventions (PCI), pacemaker implantation, and electrophysiology studies (EP studies). | Pain Management: Fluoroscopically guided injections for spinal procedures, nerve blocks, and facet joint injections. | Gastroenterology: Biliary and pancreatic interventions, such as stent placement and stone removal. | Urology: Percutaneous nephrolithotomy, ureteral stent placement, and cystography. | Emergency Medicine: Assessment of acute injuries, foreign body localization, and procedural guidance in trauma situations. |
| Biomedical Engineering Departments responsible for medical equipment maintenance. | Radiology Departments: Diagnostic fluoroscopy examinations, such as barium studies and contrast imaging. | Surgical Departments: Providing real-time imaging support during various surgical interventions. | Interventional Radiology Units: Performing minimally invasive procedures requiring precise image guidance. |
Key Aspects of C-Arm/Fluoroscopy Image Chain Repair Service:
- Diagnostic Assessment: Comprehensive evaluation of the entire image chain to identify the root cause of malfunctions.
- Component Repair/Replacement: Repair or replacement of faulty components such as X-ray tubes, detectors (image intensifiers, flat-panel detectors), video cameras, acquisition boards, and power supplies.
- Calibration and Alignment: Precise recalibration and realignment of all imaging components to ensure accurate image acquisition and display.
- Software and Firmware Updates: Updating or troubleshooting system software and firmware to resolve bugs and enhance performance.
- Image Quality Optimization: Adjustments and fine-tuning to achieve optimal image contrast, resolution, and signal-to-noise ratio.
- Preventive Maintenance: Scheduled servicing to identify and address potential issues before they lead to system failure.
- On-site and Off-site Services: Offering repair services either at the healthcare facility or at a dedicated service center.
- Training and Support: Providing training to in-house biomedical technicians on basic troubleshooting and maintenance.
Who Needs C-arm/fluoroscopy Image Chain Repair Service In Gambia?
In Gambia, the need for C-Arm/Fluoroscopy image chain repair services arises primarily within healthcare facilities that utilize this advanced imaging technology for diagnostic and interventional procedures. The image chain is a critical component of these systems, responsible for capturing, processing, and displaying high-quality X-ray images. When it malfunctions, it directly impacts the ability of medical professionals to accurately diagnose conditions and perform necessary treatments, leading to potential delays, increased costs, and compromised patient care.
| Customer Type | Key Departments Utilizing C-Arm/Fluoroscopy | Typical C-Arm Usage |
|---|---|---|
| Public Hospitals | Radiology, Orthopedics, Surgery (General, Vascular, Neurosurgery), Cardiology, Emergency | Diagnostic imaging, surgical guidance, interventional procedures, trauma assessment |
| Private Hospitals | Radiology, Orthopedics, Cardiology, General Surgery, Pain Management | Elective surgeries, specialized interventional procedures, advanced diagnostics |
| Specialized Surgical Centers | Orthopedic Surgery, Interventional Radiology, Cardiology | High-volume, specific surgical interventions requiring precise imaging |
| Government Health Initiatives | Radiology, Surgery (limited) | Basic diagnostic imaging and procedural support in underserved areas |
Target Customers & Departments for C-Arm/Fluoroscopy Image Chain Repair Service in Gambia:
- {"title":"Hospitals (Public & Private)","description":"These are the primary consumers of C-Arm/Fluoroscopy technology due to the broad range of surgical and diagnostic applications they support."}
- {"title":"Specialized Surgical Centers","description":"Facilities focused on specific surgical disciplines that heavily rely on real-time imaging."}
- {"title":"Radiology Departments","description":"The central hub for diagnostic imaging, where C-arms are extensively used for various fluoroscopic procedures."}
- {"title":"Orthopedic Departments","description":"Crucial for fracture repair, joint replacements, and other orthopedic surgeries where precise instrument placement is vital."}
- {"title":"Cardiology Departments","description":"Essential for interventional cardiology procedures like angioplasty and stent placement, requiring continuous fluoroscopic guidance."}
- {"title":"Pain Management Clinics","description":"Used for targeted injections and nerve blocks, demanding accurate visualization."}
- {"title":"Emergency Departments (ED)","description":"For rapid diagnosis and procedural guidance in acute trauma cases and other emergent situations."}
- {"title":"Government Health Initiatives & Clinics","description":"Larger government-run facilities or regional health centers that may be equipped with C-arm technology to serve a wider population."}
- {"title":"Medical Training Institutions (with clinical components)","description":"Teaching hospitals or institutions that use C-arms for both patient care and the training of future medical professionals."}
C-arm/fluoroscopy Image Chain Repair Service Process In Gambia
This document outlines the comprehensive workflow for C-Arm/Fluoroscopy Image Chain Repair Services offered in Gambia. The process is designed to be efficient, transparent, and customer-centric, ensuring minimal disruption to medical operations. It covers all stages from the initial customer inquiry to the successful completion and handover of the repaired equipment.
| Stage | Key Activities | Responsible Party | Deliverables |
|---|---|---|---|
| Inquiry & Assessment | Contact, Information Gathering, Remote Diagnosis, Quotation Generation | Client, Service Provider | Quotation, Service Agreement/Work Order |
| On-Site Service & Technical Execution | Scheduling, Travel, Diagnosis, Repair, Replacement, Testing, Calibration | Service Provider (Technicians) | Repaired Equipment, Test Results |
| Post-Repair & Handover | Quality Assurance, Client Verification, Documentation, Invoicing, Payment | Service Provider, Client | Signed Work Order, Service Report, Invoice, Paid Invoice |
C-Arm/Fluoroscopy Image Chain Repair Service Workflow
- 1. Initial Inquiry & Assessment:
- Contact Initiation: The process begins when a healthcare facility in Gambia contacts the repair service provider (either directly or through an authorized representative) to report a malfunction or request maintenance for their C-Arm/Fluoroscopy equipment.
- Information Gathering: The service provider gathers crucial details, including the specific model and serial number of the C-Arm, a detailed description of the problem (symptoms, error messages, operational issues), the urgency of the repair, and the facility's contact information.
- Preliminary Diagnosis (Remote): Based on the provided information, the service provider may attempt a remote preliminary diagnosis to understand the potential nature and complexity of the issue. This might involve guiding the facility's technical staff through basic troubleshooting steps.
- Quotation & Service Agreement: Following the initial assessment, the service provider prepares a detailed quotation outlining the estimated costs for labor, parts, and any travel expenses. Upon agreement on the quotation, a service agreement or work order is generated.
- 2. On-Site Service & Technical Execution:
- Scheduling & Logistics: Once the service agreement is in place, the repair service provider schedules the on-site visit. This involves coordinating the availability of qualified technicians, arranging travel to Gambia, and ensuring necessary tools and equipment are prepared.
- Equipment Inspection & On-Site Diagnosis: Upon arrival, the technician(s) conduct a thorough inspection of the C-Arm/Fluoroscopy system. They perform detailed diagnostics to pinpoint the exact cause of the malfunction within the image chain (e.g., X-ray tube, image intensifier, flat panel detector, camera, monitor, cabling).
- Parts Procurement (if necessary): If specific replacement parts are required and are not readily available on-site, the service provider initiates the procurement process. This may involve sourcing parts internationally, which can impact the repair timeline.
- Repair & Replacement: The technician(s) proceed with the necessary repairs, which can include cleaning, recalibrating, replacing faulty components, or re-establishing connections within the image chain.
- Testing & Calibration: After the repair is completed, rigorous testing is performed to ensure the C-Arm/Fluoroscopy system is functioning optimally. This includes image quality assessment, dose verification, and calibration to meet manufacturer specifications.
- 3. Post-Repair & Handover:
- Quality Assurance Check: A final quality assurance check is conducted by the technician(s) or a supervisor to confirm all aspects of the repair have been successfully executed and the equipment meets all performance standards.
- Client Verification & Sign-off: The healthcare facility's authorized personnel are invited to verify the repair's success and the equipment's functionality. Once satisfied, they provide a formal sign-off on the completed work order.
- Documentation & Reporting: A comprehensive service report is generated, detailing the problem, the steps taken for repair, the parts used, and the results of the testing and calibration. This report is provided to the client for their records.
- Invoicing & Payment: The final invoice is issued based on the agreed-upon quotation and any approved additional work. Payment terms are then followed as per the service agreement.
- Follow-up & Support: The service provider may offer post-repair support or maintenance advice to ensure the longevity and continued optimal performance of the repaired equipment.
C-arm/fluoroscopy Image Chain Repair Service Cost In Gambia
Providing an exact cost for C-arm/Fluoroscopy image chain repair service in Gambia is challenging due to several influencing factors. However, we can outline the typical pricing structure and provide estimated ranges in Gambian Dalasi (GMD). The 'image chain' in a C-arm fluoroscopy system refers to the entire process of image acquisition, processing, and display, encompassing components like the image intensifier or flat-panel detector, video camera, image processing hardware, and the monitor. Repairs can range from minor component replacements to extensive overhauls.
Key Pricing Factors:
- Nature and Severity of the Damage: Is it a minor software glitch, a failing component (e.g., a specific board, power supply), or a major hardware failure (e.g., a cracked image intensifier or damaged detector)? The more complex and critical the component, the higher the cost.
- Type of C-arm/Fluoroscopy System: Different manufacturers (Siemens, GE, Philips, etc.) and models have varying parts availability and costs. Older or less common systems might have more expensive or harder-to-find parts.
- Availability of Spare Parts: Importing specialized medical equipment parts into Gambia can incur significant shipping costs, customs duties, and lead times. This directly impacts the final repair price.
- Technician Expertise and Labor Costs: The skill level and experience of the biomedical technician performing the repair are crucial. Certified technicians with specialized knowledge of these complex systems will command higher labor rates.
- Diagnostic Fees: An initial assessment and diagnosis fee is usually charged to identify the problem. This is often separate from the actual repair cost.
- Urgency of the Repair: Emergency or same-day services, if available, will typically come with a premium.
- Location of Service: If the repair requires the technician to travel to a remote location within Gambia, travel expenses will be added.
- Warranty Status: If the equipment is still under warranty, the repair might be covered, negating direct costs for the user.
- Replacement vs. Repair: In some cases, it might be more cost-effective to replace a severely damaged component rather than repair it, especially if repair parts are scarce or prohibitively expensive. This decision impacts the overall cost.
Estimated Cost Ranges in Gambian Dalasi (GMD):
It's important to reiterate these are estimates. Actual costs can vary significantly. It is highly recommended to obtain quotes from multiple certified biomedical repair services operating in Gambia or those who service the region.
- Minor Repairs (e.g., calibration, software updates, minor component replacement like a fuse or small board): 5,000 GMD - 20,000 GMD
- Moderate Repairs (e.g., replacement of power supply, specific circuit boards, minor adjustments to image processing units): 20,000 GMD - 80,000 GMD
- Major Repairs (e.g., replacement of image intensifier tube, flat-panel detector, significant system overhaul): 80,000 GMD - 300,000+ GMD (and potentially much higher for complete system component failures).
Note on High-End Components: The image intensifier or flat-panel detector is often the most expensive component of the image chain. Replacement of these can easily exceed the higher end of the 'major repairs' range, sometimes reaching several hundred thousand Dalasi.
| Repair Category | Estimated Cost Range (GMD) | Description of Potential Issues |
|---|---|---|
| Minor Repairs | 5,000 - 20,000 | Software glitches, calibration issues, minor component replacements (e.g., fuses, small boards), connector repairs. |
| Moderate Repairs | 20,000 - 80,000 | Power supply unit replacement, specific circuit board failures, image processing unit adjustments, video camera component issues. |
| Major Repairs | 80,000 - 300,000+ | Image intensifier tube replacement, flat-panel detector replacement, significant system failures requiring extensive part sourcing and labor. |
Factors Influencing C-Arm/Fluoroscopy Image Chain Repair Costs in Gambia
- Nature and severity of the damage
- Type of C-arm/Fluoroscopy system (manufacturer and model)
- Availability and cost of spare parts (including import duties and shipping)
- Technician expertise and labor rates
- Diagnostic fees
- Urgency of the repair service
- Travel and accommodation expenses for technicians
- Warranty status of the equipment
- Decision to repair versus replace components
- Age and overall condition of the C-arm system
Affordable C-arm/fluoroscopy Image Chain Repair Service Options
Maintaining the operational integrity of your C-arm/fluoroscopy imaging chain is crucial for uninterrupted patient care and revenue generation. When equipment malfunctions, prompt and cost-effective repair is paramount. This guide explores affordable C-arm/fluoroscopy image chain repair service options, highlighting the value of service bundles and effective cost-saving strategies. We'll delve into why choosing the right service provider can significantly impact your budget and minimize downtime.
| Service Strategy | Description | Benefits | Cost-Saving Potential |
|---|---|---|---|
| Preventive Maintenance Contracts | Scheduled inspections, cleaning, calibration, and minor part replacements to proactively identify and address potential issues before they lead to failure. | Reduces unexpected breakdowns, extends equipment lifespan, ensures optimal image quality, and can prevent costly emergency repairs. | Lower overall repair costs by avoiding major component failures. Predictable budgeting for maintenance expenses. |
| Bundled Service Packages | Combining multiple services (e.g., preventive maintenance, on-site repairs, parts discounts, extended warranties) into a single contract or offering. | Streamlined service management, potentially lower per-service cost compared to individual services, and comprehensive support. | Significant discounts on individual services when purchased as a bundle. Reduced administrative overhead in managing multiple contracts. |
| Used or Refurbished Parts | Utilizing high-quality, pre-owned or professionally refurbished components for repairs instead of always opting for new parts. | Substantially lower material costs for repairs. | Direct reduction in the cost of replacement parts, making repairs more affordable. |
| Third-Party Service Providers | Engaging independent service organizations (ISOs) that specialize in C-arm/fluoroscopy repairs, often with lower overhead than original equipment manufacturers (OEMs). | Competitive pricing, often with faster response times and greater flexibility in service scheduling. | Generally lower labor rates and often more competitive pricing on parts compared to OEM services. |
| Remote Diagnostics and Support | Leveraging technology for initial troubleshooting and support, allowing for remote assessment of issues before an on-site visit is necessary. | Faster initial response, can resolve minor issues without a technician visit, and helps in dispatching the correct technician and parts. | Reduces unnecessary on-site visit charges. Optimized technician deployment, saving travel time and costs. |
| Extended Warranties (Strategic Purchase) | Carefully consider purchasing extended warranties, especially for critical components or after the manufacturer's warranty expires. | Protects against unexpected, high-cost repairs after the initial warranty period. | Can be more cost-effective than paying for major repairs out-of-pocket if issues arise within the warranty period. |
Understanding C-Arm/Fluoroscopy Image Chain Components
- Image Intensifier/Flat Panel Detector: The core component responsible for capturing X-ray images.
- Image Processing Unit: Handles signal amplification, digital conversion, and image enhancement.
- Monitor/Display: Presents the processed images to the radiologist or surgeon.
- Camera/Acquisition System: Captures the image data from the detector.
- Power Supply and Control Systems: Provides the necessary power and operational control for all components.
Verified Providers In Gambia
In The Gambia's healthcare landscape, ensuring you are engaging with verified and credible providers is paramount for receiving quality medical care. Franance Health stands out as a leading organization that meticulously vets and credentials healthcare professionals and facilities. This commitment to verification not only safeguards patients but also elevates the standard of healthcare services available. Understanding Franance Health's credentialing process and the reasons why their approved providers are the best choice is crucial for informed healthcare decisions in The Gambia.
| Franance Health Credentialing Process Components | What it Means for Patients |
|---|---|
| Verification of Medical Education and Degrees | Ensures providers have received legitimate and recognized medical training. |
| Validation of Professional Licenses and Certifications | Confirms that providers are legally authorized and possess the necessary specialized qualifications. |
| Thorough Background Checks and Reference Reviews | Assesses professional history, ethical conduct, and peer recommendations. |
| Assessment of Clinical Competence and Experience | Evaluates practical skills and the depth of experience in relevant medical fields. |
| Review of Facility Standards (for clinics and hospitals) | Ensures that healthcare facilities meet safety, hygiene, and equipment requirements. |
Why Franance Health Verified Providers are the Best Choice:
- Unwavering Commitment to Quality: Franance Health's rigorous vetting process ensures that only providers who meet stringent quality standards are credentialed. This includes an in-depth review of educational background, professional experience, licenses, and certifications.
- Patient Safety as a Priority: By verifying credentials, Franance Health significantly reduces the risk of patients encountering unqualified or fraudulent practitioners, thus enhancing patient safety and trust.
- Access to Specialized Expertise: The credentialing process often identifies specialists with proven track records, ensuring patients can access the most appropriate and skilled care for their specific needs.
- Ethical Practice and Professionalism: Franance Health looks for providers who adhere to high ethical standards and demonstrate a commitment to professional conduct, offering patients peace of mind.
- Facilitated Access to Reliable Healthcare: For individuals and organizations seeking healthcare services, Franance Health acts as a trusted intermediary, connecting them with verified and reliable providers.
- Continuous Monitoring and Re-evaluation: Franance Health doesn't stop at initial credentialing. They often implement ongoing monitoring and re-evaluation processes to ensure providers maintain their standards over time.
Scope Of Work For C-arm/fluoroscopy Image Chain Repair Service
This Scope of Work (SOW) outlines the requirements for the repair of a C-arm/Fluoroscopy imaging chain. It details the technical deliverables and standard specifications to ensure the successful restoration of the equipment's functionality and image quality. The service provider will be responsible for diagnosing, repairing, and testing the imaging chain components to meet or exceed original manufacturer specifications.
| Component | Standard Specification | Acceptance Criteria |
|---|---|---|
| Image Intensifier | Resolution: Minimum 4 lp/mm (center), 2 lp/mm (periphery) at specified dose rate. | Image acquisition with no visible noise, artifacts, or geometric distortion. Contrast ratio within manufacturer's specified range. |
| Camera (CCD/CMOS) | Sensitivity: Manufacturer's specified lux level for optimal signal-to-noise ratio. | Sharpness and clarity of image. No dead pixels or blooming. Accurate color reproduction (if applicable). |
| Video Processor | Frame Rate: Minimum 30 frames per second for real-time imaging. | Lag-free video display. Accurate contrast and brightness adjustments. No visible compression artifacts. |
| Monitor | Resolution: Minimum 1920x1080 (Full HD) for diagnostic imaging. | Uniform brightness and contrast across the entire screen. Accurate grayscale reproduction. No dead pixels or screen burn-in. |
| Collimation | Accuracy: Within +/- 1% of indicated field size. | Accurate and precise control of the X-ray beam. No light-field/X-ray field mismatch. |
| Image Acquisition System | Dose Rate: Within manufacturer's specified range for optimal image quality and patient safety. | Consistent and reproducible image acquisition. Appropriate dose management features functioning correctly. |
| DICOM Compliance | Full adherence to DICOM 3.0 standards for image storage and retrieval. | Successful transmission and reception of images to PACS. Correct patient and study information embedded in DICOM headers. |
Key Deliverables and Specifications
- Comprehensive diagnostic report detailing all identified issues and proposed solutions.
- Repair or replacement of faulty imaging chain components (e.g., image intensifier, camera, video processor, monitor).
- Calibration and alignment of the imaging chain to ensure optimal image quality and accuracy.
- Performance testing and validation against established image quality benchmarks.
- Updated system documentation reflecting all repairs and modifications.
- Post-repair training for hospital technical staff on system operation and basic troubleshooting (if applicable).
Service Level Agreement For C-arm/fluoroscopy Image Chain Repair Service
This Service Level Agreement (SLA) outlines the terms and conditions for the repair service of C-Arm/Fluoroscopy image chains provided by [Your Company Name] (hereinafter referred to as "Provider") to [Client Name] (hereinafter referred to as "Client"). This SLA defines response times, uptime guarantees, and associated penalties to ensure optimal performance and minimal disruption to the Client's operations.
| Service Level | Definition | Target | SLA Metric | Remedy for Breach |
|---|---|---|---|---|
| Critical Failure Response Time | For issues preventing all C-Arm/Fluoroscopy functionality. | 2 Hours | Time from service request to technician engagement. | 10% discount on the next monthly service fee for each instance exceeding the target response time. |
| Major Failure Response Time | For issues significantly impacting C-Arm/Fluoroscopy functionality but allowing some limited use. | 4 Business Hours | Time from service request to technician engagement. | 5% discount on the next monthly service fee for each instance exceeding the target response time. |
| Minor Failure Response Time | For issues impacting image quality or non-essential functions. | 8 Business Hours | Time from service request to technician engagement. | No direct financial remedy, but priority escalation for future issues. |
| Uptime Guarantee | The percentage of scheduled operating time the C-Arm/Fluoroscopy image chain is operational. | 98.5% (Monthly Average) | Percentage of uptime calculated over a calendar month. | For each full 0.5% below 98.5% but above 97%, a credit of 2% of the monthly service fee will be applied. For any downtime below 97%, a credit of 5% of the monthly service fee will be applied. |
| Resolution Time (Critical/Major) | Time to restore functionality for critical and major failures. | 24 Business Hours (for Critical/Major failures requiring on-site visit) | Time from service request to resolution. | For each 24-hour period exceeding the target resolution time for Critical/Major failures, a credit of 5% of the monthly service fee will be applied. This is capped at 20% of the monthly service fee per incident. |
Key Service Components
- Scope of Service: This SLA covers the repair and maintenance of the C-Arm/Fluoroscopy image chain components, including but not limited to the X-ray generator, image intensifier/flat panel detector, video processing unit, monitor, and associated cabling.
- Service Hours: Standard service hours are Monday through Friday, 8:00 AM to 5:00 PM local time, excluding national holidays.
- Exclusions: This SLA does not cover accidental damage, misuse, or repairs performed by unauthorized personnel. Routine preventative maintenance and consumables are covered under a separate agreement.
- Definitions:
- Downtime: Any period during which the C-Arm/Fluoroscopy image chain is non-operational and cannot be used for its intended medical purpose due to a failure covered by this SLA.
- Resolution Time: The time from when a service request is acknowledged by the Provider to when the C-Arm/Fluoroscopy image chain is restored to operational status.
- Response Time: The time from when a service request is logged by the Provider to when a qualified technician begins actively working on the issue.
- Uptime Guarantee: The percentage of time the C-Arm/Fluoroscopy image chain is expected to be operational and available for use.
- Service Request Procedure: Client shall initiate a service request by contacting the Provider's dedicated support line at [Phone Number] or via email at [Email Address]. All requests must include a detailed description of the issue, C-Arm/Fluoroscopy unit serial number, and location.
Frequently Asked Questions

Ready when you are
Let's scope your C-Arm/Fluoroscopy Image Chain Repair Service in Gambia project in Gambia.
Scaling healthcare logistics and technical systems across the entire continent.