Oxygen Cylinder Regulator in Eritrea
Leading Oxygen Cylinder Regulator Supplier
Buy Oxygen Cylinder Regulator in Eritrea. Top suppliers, installation, and warranty from Franance Health. Get a quote today.
Precise Pressure Control
Ensures accurate and stable oxygen delivery vital for patient respiratory support.
Adjustable Flow Rates
Allows medical professionals to fine-tune oxygen flow to meet individual patient needs.
Integrated Safety
Features built-in safety mechanisms to prevent over-pressurization and ensure reliable operation.
What Is An Oxygen Cylinder Regulator?
In Eritrea's healthcare sector, an Oxygen Cylinder Regulator is a critical medical device designed to safely and effectively manage the delivery of medical-grade oxygen from a compressed gas cylinder to a patient. It serves as an intermediary, translating the high-pressure gas stored within the cylinder into a usable, stable, and precisely controlled flow rate suitable for therapeutic administration. Constructed from durable materials, typically brass or stainless steel for longevity and purity, the regulator attaches directly to the cylinder valve.
Its primary function is twofold: pressure reduction and flow control. When attached, the regulator reduces the extremely high pressure (often exceeding 2000 psi) within the cylinder to a safe and manageable working pressure. Simultaneously, it enables precise adjustment and maintenance of the oxygen flow rate, measured in liters per minute (LPM), ensuring that patients receive the exact therapeutic dosage prescribed by clinicians. This controlled delivery is vital for patient safety and treatment efficacy, preventing both under-oxygenation and over-oxygenation, which can have serious health consequences.
Key Clinical Applications:
- Respiratory Support: Providing supplemental oxygen to patients suffering from conditions like COPD, pneumonia, asthma exacerbations, and acute respiratory distress syndrome (ARDS).
- Emergency Medicine: Essential for immediate oxygen administration in trauma, cardiac arrest, and other critical care scenarios where rapid oxygenation is paramount.
- Anesthesia and Surgery: Used to deliver precise oxygen concentrations during surgical procedures, ensuring adequate patient oxygenation.
- Neonatal Care: Facilitating controlled oxygen delivery for premature infants and newborns experiencing respiratory difficulties.
- Chronic Disease Management: Enabling long-term oxygen therapy for individuals with severe chronic respiratory conditions requiring continuous or intermittent oxygen supplementation.
Who Needs Oxygen Cylinder Regulator In Eritrea?
In Eritrea, a reliable oxygen supply is critical for patient care across a spectrum of healthcare facilities. Oxygen cylinder regulators are indispensable components for accurately controlling and delivering medical-grade oxygen from portable cylinders to patients. Their need spans from major urban centers to remote rural areas where oxygen therapy is a cornerstone of treatment.
Facilities requiring these regulators range from large tertiary and teaching hospitals, where complex medical interventions and intensive care are standard, to smaller district hospitals and community health centers. Even mobile medical units and specialized clinics that offer diagnostic or therapeutic services necessitating oxygen support will depend on these devices.
| Facility Type | Primary Need for Regulators |
|---|---|
| Large Hospitals (Tertiary/Teaching) | Sustained, high-volume oxygen therapy, critical care support, surgical procedures. |
| District Hospitals | Emergency oxygen for acute respiratory distress, chronic conditions, and general patient care. |
| Community Health Centers/Clinics | Oxygen for basic life support, management of common respiratory ailments, and stabilization of emergencies. |
| Emergency Services | Rapid and controlled oxygen delivery in pre-hospital and emergency settings. |
Key Facility Types and Departments Requiring Oxygen Cylinder Regulators:
- Tertiary & Teaching Hospitals (e.g., National Referral Hospital)
- District Hospitals
- Community Health Centers & Clinics
- Emergency Medical Services & Ambulance Services
- Surgical Departments
- Intensive Care Units (ICUs)
- Emergency Rooms / Accident & Emergency (A&E) Departments
- Pulmonary/Respiratory Departments
- Pediatric Wards & Neonatal Intensive Care Units (NICUs)
- Anesthesiology Departments
- Rehabilitation Centers
- Mobile & Field Hospitals
Installation Process For Oxygen Cylinder Regulator
Ensuring the proper and safe installation of your oxygen cylinder regulator is paramount for effective medical oxygen delivery in Eritrea. Our team is committed to providing clear guidance and support throughout this process. We recommend following these steps for a smooth and secure setup, whether performed by your in-house biomedical team or a technician arranged through us.
Site Preparation
Before delivery and installation, ensure the designated location is clean, well-ventilated, and free from any potential ignition sources such as open flames, sparks, or smoking materials. The area should be easily accessible for routine checks and maintenance, and the oxygen cylinder should be stored upright and secured to prevent tipping.
Delivery And Inspection
Upon delivery, carefully inspect the oxygen cylinder regulator and all associated components for any signs of damage that may have occurred during transit. Verify that all ordered parts are present and that the regulator's connections are compatible with your oxygen cylinders. Report any discrepancies or damage immediately.
Installation Steps
- Cylinder Connection: Ensure the oxygen cylinder valve is fully closed. Align the regulator's yoke with the cylinder outlet and secure it using the provided screw or hand-tighten the connection nut. Do not overtighten.
- Leak Check: Slightly open the cylinder valve to allow a small flow of oxygen. Apply a soapy water solution to all connections (cylinder valve outlet, regulator inlet, and any other fittings). Observe for bubbles, which indicate a leak. If leaks are detected, close the cylinder valve immediately and re-tighten the connection.
- Flow Adjustment: Once leaks are confirmed absent, slowly open the cylinder valve fully. Adjust the regulator's flow control knob to the desired therapeutic oxygen flow rate as prescribed by a medical professional.
- Connection to Delivery Device: Connect the oxygen tubing from the regulator's outlet to the patient's delivery device (e.g., nasal cannula, mask).
Calibration Requirements
Regular calibration is essential to guarantee the accuracy of the oxygen flow. We recommend:
- Initial Calibration: Immediately after installation, verify the delivered flow rate using a calibrated oxygen flow meter. Ensure it matches the setting on the regulator.
- Periodic Calibration: Calibration should be performed at regular intervals as per the manufacturer's recommendations and local healthcare regulations in Eritrea, typically every 6 to 12 months. This ensures ongoing accuracy and patient safety.
- Post-Maintenance Calibration: Always recalibrate the regulator after any servicing, repair, or part replacement.
For expert installation and calibration services in Eritrea, please contact our dedicated support team.
Key Considerations for Installation
- Ensure a well-ventilated and ignition-free environment.
- Inspect all components for damage upon delivery.
- Perform a thorough leak check before patient use.
- Calibrate the regulator with a certified flow meter.
How Much Is An Oxygen Cylinder Regulator In Eritrea?
The cost of an oxygen cylinder regulator in Eritrea can vary significantly based on factors such as the brand, model, condition (new versus refurbished), and the specific supplier. While precise, up-to-the-minute pricing is difficult to ascertain without direct inquiries to local medical equipment providers, we can offer a realistic broad range in Eritrean Nakfa (ERN). It's important to note that these are estimates and actual prices may differ.
New Regulators: For a brand-new, reliable oxygen cylinder regulator from a reputable manufacturer, you can generally expect prices to fall within the range of 2,500 ERN to 8,000 ERN. Higher-end models with advanced features or specific certifications may be at the upper end of this spectrum or even exceed it.
Refurbished Regulators: Refurbished oxygen cylinder regulators offer a more budget-friendly option. These units have been previously used, inspected, serviced, and restored to good working order. The price range for a refurbished regulator typically spans from 1,000 ERN to 3,500 ERN. It is crucial to ensure that any refurbished regulator purchased comes with a guarantee of functionality and has been professionally serviced to meet safety standards.
Several factors can influence these price points:
- Brand and Quality: Well-known international brands may command higher prices.
- Features: Regulators with integrated flowmeters, pressure gauges, and different connection types will impact cost.
- Supplier: Prices can vary between larger medical supply stores and smaller, independent retailers.
- Availability: Supply and demand dynamics within Eritrea can also play a role.
For the most accurate and current pricing, it is highly recommended to contact local Eritrean medical equipment suppliers directly. They will be able to provide specific quotes based on available inventory and your particular requirements.
Affordable Oxygen Cylinder Regulator Options
We understand the importance of reliable oxygen therapy, especially for healthcare facilities in Eritrea operating with budget constraints. Our commitment is to provide accessible and cost-effective solutions. Explore our range of value-focused oxygen cylinder regulator options, designed to deliver performance without compromising your financial planning. Whether you are equipping a new clinic, expanding existing services, or seeking to upgrade older equipment, we offer solutions tailored to your needs and budget.
| Option Type | Key Benefit | Ideal For |
|---|---|---|
| Refurbished Regulators | Significant Cost Savings | Budget-constrained clinics and hospitals |
| Demo Models | Near-new quality at a lower price | Facilities seeking advanced features affordably |
| Entry-Level Systems | Reliability & Affordability | New facilities or those needing basic, dependable regulation |
Discover Value in Our Range:
- Refurbished Oxygen Regulators: Expertly restored and thoroughly tested, our refurbished regulators offer significant cost savings while meeting stringent quality standards. These units provide the same essential functionality and reliability as new models, making them an excellent choice for budget-conscious institutions.
- Demonstration (Demo) Models: Occasionally, we have high-quality demonstration models available at reduced prices. These units have seen minimal use and are in excellent working condition, offering a near-new experience at a more affordable price point.
- Entry-Level Systems: For facilities requiring essential, dependable oxygen regulation without advanced features, our entry-level systems provide a robust and cost-effective solution. These regulators are designed for durability and ease of use, ensuring consistent oxygen delivery.
Verified Oxygen Cylinder Regulator Suppliers In Eritrea
For reliable and high-quality oxygen cylinder regulators in Eritrea, Franance Health stands as your trusted partner. We understand the critical nature of medical equipment and are committed to providing solutions that meet stringent international standards. When you choose Franance Health, you benefit from our unwavering dedication to excellence, ensuring your medical facility has access to the best possible equipment.
Our commitment to quality is underpinned by several key factors:
Why Choose Franance Health for Oxygen Cylinder Regulators?
- Direct OEM Partnerships: We maintain strong, direct relationships with leading Original Equipment Manufacturers (OEMs) globally. This allows us to source genuine, top-tier oxygen cylinder regulators directly from the factories, guaranteeing authenticity and adherence to the highest manufacturing standards. These partnerships ensure you receive products that are precisely as intended by their designers, offering unparalleled performance and safety.
- Local Engineering Team: Franance Health is proud to have a dedicated local engineering team right here in Eritrea. Our experts possess intimate knowledge of the local healthcare infrastructure and regulatory landscape. They are available to provide on-site technical support, installation guidance, and comprehensive training for your staff. This local presence means faster response times and solutions tailored to your specific operational needs, minimizing downtime and maximizing equipment efficiency.
- Comprehensive Warranty and Support: We back every oxygen cylinder regulator we supply with a robust warranty. This commitment extends beyond the initial sale, providing you with peace of mind knowing that your investment is protected. Our local support team is readily available to assist with any queries, maintenance, or repair needs, ensuring the long-term reliability and optimal functioning of your vital medical equipment.
Standard Configuration & Accessories
When procuring an oxygen cylinder regulator for your healthcare facility in Eritrea, the standard package typically includes the essential components for immediate and safe operation. These regulators are designed for direct connection to medical oxygen cylinders and are built to withstand the rigorous demands of clinical environments.
| Component | Description |
|---|---|
| Regulator Unit | Precisely controls and displays oxygen pressure from the cylinder and delivers oxygen at a controlled flow rate. |
| Cylinder Connection | Ensures a secure and leak-free seal with the oxygen cylinder's outlet valve. |
| User Documentation | Provides crucial information on setup, operation, maintenance, and safety protocols specific to the regulator model. |
Standard Inclusions:
- Oxygen Cylinder Regulator Unit (pressure gauge, flowmeter, and control knob)
- Cylinder Connection Nut and Washer (compatible with common Eritrean cylinder valve types)
- Operating Manual and Safety Guidelines
Warranty & Maintenance Plans
We understand the critical role of reliable oxygen supply in healthcare settings across Eritrea. That's why our oxygen cylinder regulators are backed by comprehensive warranty and maintenance plans designed to ensure uninterrupted operation and long-term value. Our standard warranty covers manufacturing defects, providing peace of mind with your purchase. Beyond the initial warranty, we offer tailored preventive maintenance (PPM) programs. These proactive services are crucial for maintaining optimal performance, extending the lifespan of your regulators, and minimizing the risk of unexpected downtime. Our Eritrea-based service team is equipped to conduct regular inspections, calibrations, and minor adjustments. Furthermore, we maintain a robust stock of genuine spare parts, ensuring that any necessary replacements are handled swiftly and efficiently, minimizing any potential disruption to your patient care services.
| Plan Type | Coverage Details | Frequency |
|---|---|---|
| Standard Warranty | Covers manufacturing defects. | As per product documentation. |
| Preventive Maintenance (PPM) | Includes inspection, calibration, cleaning, and minor adjustments. | Quarterly or Bi-annually (customizable). |
| On-Demand Repair Service | For urgent issues outside of PPM schedule. | As needed. |
Key Benefits of Our Plans:
- Extended equipment lifespan through regular servicing.
- Reduced risk of unexpected operational failures.
- Prioritized access to genuine spare parts.
- Expert technical support from trained professionals.
- Compliance with healthcare standards and regulations.
Frequently Asked Questions
Related Products

Ready whenever you are
Let's discuss your Oxygen Cylinder Regulator in Eritrea requirements in Eritrea.
Scaling healthcare logistics and technical systems across the entire continent.