Oxygen Cylinder Regulator in Congo (Kinshasa)
Leading Oxygen Cylinder Regulator Supplier
Buy Oxygen Cylinder Regulator in Congo (Kinshasa). Top suppliers, installation, and warranty from Franance Health. Get a quote today.
Reliable Pressure Control
Ensures consistent and safe oxygen delivery pressure crucial for critical medical procedures.
Precise Flow Meter
Allows healthcare professionals to accurately adjust and monitor oxygen flow rates for individualized patient needs.
Durable Construction
Built to withstand demanding conditions, providing dependable performance in challenging environments.
What Is An Oxygen Cylinder Regulator?
An oxygen cylinder regulator is a crucial medical device designed to control the flow of medical-grade oxygen from a high-pressure cylinder to a patient. It serves two primary functions: firstly, to reduce the high pressure within the oxygen cylinder (typically up to 2000 psi) to a safe and usable lower pressure for patient delivery, and secondly, to precisely regulate the flow rate of oxygen in liters per minute (LPM) as prescribed by a healthcare professional. This ensures that patients receive the correct oxygen concentration and volume needed for therapeutic purposes, preventing both under-delivery and over-delivery of this vital gas.
| Component | Function |
|---|---|
| Pressure Reducer (Diaphragm and Spring) | Safely lowers the high cylinder pressure to a workable level. |
| Flow Meter (Variable Orifice or Bourdon Gauge) | Controls and indicates the precise oxygen flow rate in LPM. |
| Pressure Gauge | Displays the remaining oxygen pressure within the cylinder. |
| Outlet Port | Connects to oxygen tubing or masks for patient delivery. |
Key Clinical Applications:
- Hypoxemia management in patients with respiratory conditions (e.g., COPD, pneumonia, asthma).
- Adjunctive therapy during surgical procedures and post-operative recovery.
- Emergency response and critical care for patients experiencing respiratory distress or failure.
- Support for patients undergoing transportation or in settings where piped medical gas is unavailable.
- Use in hyperbaric oxygen therapy (though often with specialized regulators).
Who Needs Oxygen Cylinder Regulator In Congo (Kinshasa)?
In Congo (Kinshasa), the reliable and safe delivery of medical oxygen is critical across a spectrum of healthcare settings. An oxygen cylinder regulator is an indispensable component for any facility or department that utilizes compressed oxygen cylinders to administer life-saving respiratory support. These regulators are essential for controlling and reducing the high pressure within oxygen cylinders to a safe and usable level for patients, ensuring consistent flow rates and preventing oxygen-induced complications. Their importance spans from large, specialized medical centers to remote community health posts.
Key Facility Types and Departments Requiring Oxygen Cylinder Regulators:
- Public and Private Hospitals: Including general hospitals, provincial hospitals, and national reference hospitals, which form the backbone of healthcare delivery.
- Teaching and University Hospitals: These institutions require robust and accurate equipment for patient care and medical education, particularly in critical care and surgical departments.
- Specialized Medical Centers: Such as cardiology centers, pulmonology clinics, and emergency care facilities where respiratory support is a primary concern.
- Maternity and Neonatal Units: Crucial for premature infants and newborns experiencing respiratory distress, requiring precise oxygen delivery.
- Surgical Theaters and Operating Rooms: Essential for anesthesia administration and immediate post-operative respiratory management.
- Intensive Care Units (ICUs) and Critical Care Units (CCUs): Where continuous and precisely controlled oxygen therapy is a daily necessity for critically ill patients.
- Emergency Rooms and Accident & Emergency (A&E) Departments: For immediate stabilization and treatment of patients with respiratory emergencies, trauma, and acute illnesses.
- Community Health Centers and Clinics: Especially those in underserved or remote areas where oxygen cylinders are the primary source of medical oxygen for a variety of conditions, from pneumonia to chronic respiratory diseases.
- Mobile and Field Hospitals: Often deployed during health crises or in disaster-stricken regions, requiring portable and reliable oxygen delivery systems.
- Rehabilitation Centers and Long-Term Care Facilities: For patients managing chronic respiratory conditions such as COPD or severe asthma.
Installation Process For Oxygen Cylinder Regulator
Ensuring the correct and safe installation of your oxygen cylinder regulator is paramount for optimal performance and patient safety. This section outlines the essential steps involved, from preparing the site to final calibration, tailored for the specific context of Congo (Kinshasa).
Site Preparation
Before delivery and installation, it is crucial to prepare the designated area. This includes:
- Ventilation: Ensure the installation area is well-ventilated to prevent any accidental oxygen accumulation. Avoid confined spaces.
- Cleanliness: The area should be clean and free from dust, oil, grease, and any flammable materials. Oil and grease can react dangerously with high-pressure oxygen.
- Accessibility: The installation site should be easily accessible for routine checks, maintenance, and cylinder changes.
- Stability: The mounting surface or stand for the regulator and cylinder must be stable and capable of supporting the weight of a full cylinder.
- Proximity to Use Point: While ensuring ventilation, the installation should also be reasonably close to the point of use to minimize oxygen delivery line length, reducing pressure drop.
Delivery And Initial Inspection
Upon delivery of the oxygen cylinder and regulator, conduct a thorough visual inspection:
- Packaging: Check for any damage to the packaging.
- Regulator: Inspect the regulator for any visible dents, cracks, or signs of tampering. Ensure all fittings are present and clean.
- Cylinder Valve: Verify that the cylinder valve is intact and free from obstructions.
Installation Steps
Follow these steps carefully for a secure and safe installation:
- Secure the Cylinder: Ensure the oxygen cylinder is upright and securely fastened to a wall bracket or stand to prevent tipping.
- Connect the Regulator:
- Thread Compatibility: Confirm that the regulator's inlet connection is compatible with the oxygen cylinder's outlet valve fitting (e.g., CGA 870 in many regions). Do not force connections.
- Tightening: Gently screw the regulator onto the cylinder valve by hand until snug. Then, using a suitable wrench (avoiding over-tightening), tighten the connection. For safety, ensure you are using the correct type of wrench, preferably one that does not create sparks.
- Leak Check: Before opening the cylinder valve fully, slightly open it to allow a small amount of gas to escape and then immediately close it. Listen for any hissing sounds indicating a leak. If a leak is detected, tighten the connection slightly. If the leak persists, disconnect and re-examine the fittings. Specialized leak detection solutions can also be used.
- Open Cylinder Valve: Slowly and fully open the cylinder valve. Listen for the sound of gas flow.
- Adjust Pressure: Use the regulator's adjustment knob to set the desired outlet pressure or flow rate as required by the medical application.
Calibration And Verification Requirements
Regular calibration and verification are essential for the accurate and reliable functioning of the oxygen regulator:
- Flow Rate Verification: Use a calibrated oxygen flow meter to verify that the regulator delivers the set flow rates accurately. This is critical for patient therapy.
- Pressure Gauge Check: Ensure the pressure gauges on the regulator are functioning correctly and displaying appropriate readings. Compare readings with a known accurate gauge if possible.
- Leak Testing: Perform routine leak tests on the entire system (cylinder connection, regulator, tubing) at regular intervals as per manufacturer recommendations and local protocols.
- Scheduled Maintenance: Adhere to a schedule for professional servicing and recalibration by qualified technicians, especially after prolonged periods of disuse or if any performance anomalies are observed.
- Documentation: Maintain a log of all installation, calibration, and maintenance activities.
Note: In the context of Congo (Kinshasa), it is highly recommended to source regulators and cylinders from reputable suppliers who can provide certified equipment and technical support. For any complex installations or troubleshooting, consult with trained biomedical engineers or technicians.
| Component | Inspection Point | Frequency |
|---|---|---|
| Regulator Inlet | Visual inspection for damage and cleanliness | Before each use |
| Regulator Gauges | Functionality and reading accuracy | Weekly |
| Cylinder Valve | Proper seal and absence of leaks | Before each use |
| Oxygen Flow | Accuracy against set rate | Monthly (or as per clinical protocol) |
| Complete System | Leak test | Monthly |
Key Safety Precautions:
- Never use oil or grease on oxygen equipment.
- Ensure adequate ventilation at all times.
- Always open cylinder valves slowly.
- Perform regular leak checks.
How Much Is An Oxygen Cylinder Regulator In Congo (Kinshasa)?
The price of an oxygen cylinder regulator in Congo (Kinshasa) can vary significantly based on several factors, including whether the unit is new or refurbished, the brand and quality of the regulator, and the specific supplier. For healthcare facilities and distributors in the region, understanding these price ranges is crucial for budgeting and procurement.
<b>New Oxygen Cylinder Regulators:</b> For a brand-new, reliable oxygen cylinder regulator from a reputable manufacturer, you can typically expect prices to range from approximately 150,000 Congolese Francs (CDF) to 500,000 Congolese Francs (CDF) or more. High-end models with advanced features, durable materials, and certifications may fall at the upper end of this spectrum or exceed it. These are ideal for facilities prioritizing the latest technology and longest lifespan.
<b>Refurbished Oxygen Cylinder Regulators:</b> Refurbished regulators offer a more budget-friendly option. These units have been previously used but have undergone inspection, cleaning, and repair to ensure they are in good working condition. Prices for refurbished oxygen cylinder regulators in Congo (Kinshasa) generally range from around 70,000 Congolese Francs (CDF) to 250,000 Congolese Francs (CDF). It's essential to purchase refurbished units from trusted suppliers who can provide assurance of their functionality and safety.
When making a purchase, it is always advisable to obtain quotes from multiple suppliers to compare prices and explore available options. Consider the specific needs of your medical facility, including the type of oxygen cylinders used and the required level of precision and durability.
Affordable Oxygen Cylinder Regulator Options
We understand the critical need for reliable medical equipment, even with budget constraints. That's why we offer a range of cost-effective oxygen cylinder regulator solutions tailored for healthcare facilities in Congo (Kinshasa). Explore our value-focused options, including meticulously inspected and certified refurbished units, practically new demo models, and robust entry-level systems designed to deliver essential oxygen therapy without compromising quality or patient care.
Our Affordable Solutions Include:
- Certified Refurbished Regulators: Offering significant savings with the assurance of rigorous testing and functionality.
- Demo Models: High-quality units used for demonstrations, available at reduced prices.
- Entry-Level Systems: Dependable and straightforward regulators perfect for essential oxygen delivery needs.
Verified Oxygen Cylinder Regulator Suppliers In Congo (Kinshasa)
When sourcing critical medical equipment like oxygen cylinder regulators in Congo (Kinshasa), reliability and trust are paramount. Franance Health stands as a premier choice for healthcare providers seeking assurance in their supply chain. Our commitment to quality is underscored by strategic OEM partnerships, ensuring that the regulators we supply are manufactured to the highest international standards. Furthermore, our dedicated local engineering team provides unparalleled on-the-ground support, offering installation, maintenance, and troubleshooting services tailored to the specific needs and environment of Kinshasa. This local expertise guarantees swift response times and expert handling of your equipment. Every oxygen cylinder regulator purchased from Franance Health is backed by a comprehensive warranty, providing you with peace of mind and protecting your investment. Choose Franance Health for dependable, supported, and certified oxygen cylinder regulators that meet the demanding requirements of healthcare delivery in Congo (Kinshasa).
Standard Configuration & Accessories
When you acquire an oxygen cylinder regulator for your medical facility in Congo (Kinshasa), the standard package is designed to provide immediate functionality and essential support. While specific inclusions may vary slightly between manufacturers and models, a typical box will contain the core regulator unit, ensuring precise control over oxygen flow from your cylinders. We understand the critical nature of medical supply chains in the region, and our offerings are curated to meet these demands.
| Component | Description | Relevance in Congo (Kinshasa) |
|---|---|---|
| Oxygen Cylinder Regulator Unit | The main device for pressure reduction and flow control. | Essential for safe and effective oxygen therapy delivery from standard cylinders. |
| CGA 870 Cylinder Connection | The standard fitting that connects the regulator to most medical oxygen cylinders. | Ensures compatibility with commonly available oxygen cylinders in the DRC. |
| Gauges | High-pressure gauge shows cylinder contents; low-pressure gauge shows output pressure. | Crucial for monitoring oxygen supply levels and ensuring correct delivery pressure for patient safety. |
| Flowmeter | Allows for precise adjustment and measurement of oxygen flow rate (e.g., in liters per minute). | Indispensable for titrating oxygen therapy according to patient needs and medical protocols. |
| Humidifier Connector Port | A port designed to attach a separate humidifier. | Important for patient comfort and to prevent drying of mucous membranes during prolonged oxygen administration, a consideration in varying environmental conditions. |
| User Manual & Warranty | Documentation for operation, maintenance, and proof of purchase. | Provides essential guidance for proper use and ensures support for your investment. |
What's typically included:
- Oxygen Cylinder Regulator Unit (primary device)
- CGA 870 (or relevant regional standard) Cylinder Connection
- Gauges (High-pressure and low-pressure indicators)
- Flowmeter with selection dial
- Humidifier Connector Port (for attaching external humidifiers)
- O-ring seals and necessary washers
- User Manual with operating instructions and maintenance guidelines
- Product Warranty Information
Warranty & Maintenance Plans
We understand the critical nature of reliable medical equipment in healthcare settings across Congo (Kinshasa). To ensure your oxygen cylinder regulators operate at peak performance and longevity, we offer comprehensive warranty and maintenance plans. Our standard warranty provides peace of mind against manufacturing defects, ensuring your investment is protected. Beyond the initial warranty period, our tailored Preventive Maintenance Programs (PPM) are designed to proactively identify and address potential issues before they impact patient care or lead to costly downtime. These plans include regular inspections, calibration, and cleaning by certified technicians familiar with the specific demands of medical oxygen delivery in your region.
| Plan Type | Coverage Details | Ideal For |
|---|---|---|
| Standard Warranty | Covers manufacturing defects for [Specify Duration, e.g., 12 months]. Parts and labor included. | New equipment purchasers seeking initial protection. |
| Preventive Maintenance (PPM) | Scheduled inspections, cleaning, and minor adjustments. Proactive issue identification. | Facilities aiming to minimize downtime and extend equipment lifespan. |
| Comprehensive Service Plan | Includes PPM, priority spare parts, and [Specify other inclusions, e.g., emergency repair call-outs]. | Healthcare providers requiring maximum uptime and operational assurance. |
Key Features of Our Plans:
- Standard limited warranty on all new oxygen cylinder regulators.
- Scheduled preventive maintenance visits to ensure optimal performance.
- Priority access to genuine spare parts for quick replacements.
- On-site troubleshooting and repair services by trained professionals.
- Flexible plan options to suit your facility's budget and needs.
Frequently Asked Questions
Related Products

Ready whenever you are
Let's discuss your Oxygen Cylinder Regulator in Congo (Kinshasa) requirements in Congo (Kinshasa).
Scaling healthcare logistics and technical systems across the entire continent.