Ventilator Oxygen Sensor in Congo (Brazzaville)
Leading Ventilator Oxygen Sensor Supplier
Buy Ventilator Oxygen Sensor in Congo (Brazzaville). Top suppliers, installation, and warranty from Franance Health. Get a quote today.
Accurate O2 Monitoring
Ensures precise delivery of oxygen therapy by continuously measuring patient's fractional inspired oxygen (FiO2).
Critical Ventilation Support
Essential component for mechanical ventilators, enabling clinicians to maintain optimal oxygen levels during respiratory support.
Reliable Performance
Provides dependable and accurate readings in demanding clinical environments, vital for patient safety in Brazzaville's healthcare facilities.
What Is A Ventilator Oxygen Sensor?
A ventilator oxygen sensor, also known as an oxygen "puck" or "probe," is a critical component integrated into modern mechanical ventilators. Its primary function is to continuously and accurately measure the concentration of oxygen (FiO2) being delivered to a patient. This measurement is essential for ensuring the correct and safe oxygen levels are administered, preventing both hypoxemia (dangerously low blood oxygen) and hyperoxemia (dangerously high blood oxygen), which can lead to tissue damage and other complications.
These sensors utilize electrochemical principles to detect oxygen molecules. By analyzing the electrical current or voltage generated in response to the oxygen concentration, the sensor provides real-time data that is displayed on the ventilator's interface. This allows clinicians to monitor and adjust the FiO2 delivered, ensuring optimal patient respiratory support.
| Sensor Type | Principle of Operation | Typical Lifespan |
|---|---|---|
| Electrochemical (Galvanic/Clark-type) | Generates a current proportional to oxygen partial pressure. | 6-12 months (dependent on usage and environment) |
| Paramagnetic | Measures oxygen's magnetic properties. | Longer lifespan, often integrated into the ventilator unit. |
Key Clinical Applications:
- Precise management of FiO2 in critically ill patients requiring mechanical ventilation.
- Titration of oxygen therapy to meet specific patient needs, from neonates to adults.
- Monitoring and alarm functions to alert caregivers to deviations from prescribed oxygen levels.
- Support for a wide range of ventilation modes, including volume-controlled, pressure-controlled, and spontaneous breathing modes.
- Facilitating weaning from mechanical ventilation by ensuring appropriate oxygen support during the process.
Who Needs Ventilator Oxygen Sensor In Congo (Brazzaville)?
In Congo (Brazzaville), critical care and respiratory support are paramount for patient survival. The reliable functioning of ventilators is directly dependent on accurate oxygen sensing. Therefore, a wide range of healthcare facilities and departments require high-quality ventilator oxygen sensors to ensure optimal patient outcomes. These essential components are vital for monitoring and adjusting oxygen levels, preventing hypoxemia or hyperoxemia, and supporting patients with respiratory distress.
| Facility Type | Key Departments/Units |
|---|---|
| University/Teaching Hospitals | ICU, NICU, ED, OR, Respiratory Therapy |
| General Hospitals | ICU, ED, Surgical Wards, Respiratory Therapy |
| Specialized Respiratory Centers | Ventilator Management Units, Inpatient Wards |
| Emergency Departments | Trauma Bays, Resuscitation Areas |
| Neonatal Intensive Care Units | Incubators with Ventilator Support |
| Surgical Wards/ORs | Recovery Rooms, Post-Anesthesia Care Units (PACU) |
| Anesthesiology Departments | Operating Rooms |
Key Healthcare Facilities and Departments Requiring Ventilator Oxygen Sensors:
- University Hospitals and Teaching Hospitals: These institutions are typically equipped with advanced critical care units and serve as referral centers, necessitating a robust supply of reliable oxygen sensors for their intensive care units (ICUs), neonatal intensive care units (NICUs), and emergency departments.
- General Hospitals: All general hospitals with established intensive care units or surgical wards where patients may require mechanical ventilation are prime consumers of these sensors. This includes facilities in both urban and larger semi-urban centers.
- Specialized Respiratory Care Centers: Facilities dedicated to the management of chronic respiratory conditions or acute respiratory failure will have a consistent need for functional oxygen sensors to support long-term ventilation or during exacerbations.
- Emergency Departments (EDs): The rapid assessment and stabilization of critically ill patients in EDs often involves immediate intubation and mechanical ventilation, making accurate oxygen sensing an urgent requirement.
- Intensive Care Units (ICUs): This is the primary location where ventilators are most frequently utilized. ICU teams rely on precise oxygen measurements to manage patients with severe respiratory failure, sepsis, trauma, and post-operative complications.
- Neonatal Intensive Care Units (NICUs): Premature infants and newborns with respiratory issues often require mechanical ventilation. NICUs demand highly sensitive and accurate oxygen sensors to manage the delicate respiratory needs of these vulnerable patients.
- Surgical Wards/Operating Rooms (ORs): Post-operative patients, especially those undergoing major surgery, may require ventilation. Oxygen sensors are crucial during and immediately after surgical procedures to ensure adequate oxygenation.
- Anesthesiology Departments: Anesthesiologists utilize ventilators during surgical procedures, making functional oxygen sensors a critical component of their equipment.
Installation Process For Ventilator Oxygen Sensor
Ensuring the accurate and reliable performance of your ventilator is paramount, and the proper installation of the oxygen sensor is a critical step. This guide outlines the essential procedures for site preparation, delivery, installation, and calibration of your Ventilator Oxygen Sensor in Congo (Brazzaville).
Site Preparation
Before the sensor arrives, ensure the installation area is clean, dry, and free from potential contaminants. The ventilator itself should be in its designated location and powered off. Confirm that all necessary accessories and tools, as provided by the manufacturer, are readily available. A stable, level surface for the ventilator is crucial to prevent any movement during installation.
Delivery And Unpacking
Upon delivery, carefully inspect the packaging for any signs of damage. Once satisfied, unpack the Ventilator Oxygen Sensor in a controlled environment. Handle the sensor with care, avoiding direct contact with the sensing element to prevent contamination or damage. Compare the received unit against the order confirmation and packing slip to ensure accuracy.
Installation Steps
The installation process is straightforward and typically involves the following steps:
- Locate Sensor Port: Identify the designated oxygen sensor port on your specific ventilator model. This is usually clearly marked.
- Connect Sensor: Carefully align and insert the sensor's connector into the port. Ensure a secure and snug fit. Avoid forcing the connection.
- Secure Sensor: Depending on the model, there may be a locking mechanism or screw to secure the sensor in place. Follow the manufacturer's instructions to ensure it is firmly attached.
- Route Cable: Gently route the sensor's cable away from moving parts and potential pinch points on the ventilator.
- Power On Ventilator: Once the sensor is securely installed and the cable is routed, power on the ventilator.
Calibration Requirements
Calibration is a vital step to guarantee the accuracy of oxygen readings. The specific calibration procedure will vary by ventilator model and sensor type. Always refer to the official manufacturer's user manual for detailed instructions.
- Initial Calibration: Most sensors require an initial calibration upon first installation or after a significant period of non-use.
- Post-Installation Check: A post-installation calibration ensures the sensor is functioning correctly within the ventilator's system.
- Routine Calibration: Regular calibration checks, as recommended by the manufacturer (e.g., daily, weekly, or monthly), are essential to maintain accuracy.
- Alarm Verification: During calibration, verify that the ventilator's low and high oxygen alarms are functioning correctly.
For any specific calibration procedures or troubleshooting in Congo (Brazzaville), please consult your authorized service representative or the ventilator manufacturer's technical support.
| Step | Description | Notes |
|---|---|---|
| Site Preparation | Clean and prepare the installation area. | Ventilator must be powered off. |
| Delivery Inspection | Check for visible damage to packaging. | Verify order against received item. |
| Sensor Connection | Carefully insert sensor connector. | Do not force the connection. |
| Securing Sensor | Engage any locking mechanisms. | Ensure a firm attachment. |
| Calibration | Follow OEM manual for procedure. | Crucial for accurate readings. |
Key Considerations for Installation
- Ensure a sterile environment during unpacking and handling.
- Confirm compatibility between the sensor and your specific ventilator model.
- Always refer to the original equipment manufacturer's (OEM) manual.
- Keep a record of installation and calibration dates.
How Much Is A Ventilator Oxygen Sensor In Congo (Brazzaville)?
The cost of ventilator oxygen sensors in Congo (Brazzaville) can vary significantly based on several factors, including the sensor's brand, model, technological specifications, and whether it is a brand-new unit or a certified refurbished option. For new, high-quality oxygen sensors compatible with a range of modern ventilators, you might expect prices to range broadly from 200,000 to 750,000 Congolese Francs (XAF). Refurbished sensors, while offering a more budget-friendly alternative, typically fall within a range of 100,000 to 350,000 XAF. It's important to note that these are general estimates, and actual pricing can be influenced by supplier margins, import duties, and current market availability. For the most accurate and up-to-date pricing, direct inquiries with reputable medical equipment suppliers in Congo (Brazzaville) are recommended.
| Sensor Type | Estimated Price Range (XAF) |
|---|---|
| New Ventilator Oxygen Sensor | 200,000 - 750,000 |
| Refurbished Ventilator Oxygen Sensor | 100,000 - 350,000 |
Factors Influencing Price:
- Brand and Manufacturer
- Sensor Technology and Accuracy
- Compatibility with Specific Ventilator Models
- Condition (New vs. Refurbished)
- Supplier and Import Costs
- Volume of Purchase
Affordable Ventilator Oxygen Sensor Options
Understanding the critical need for reliable respiratory support in Congo (Brazzaville), we offer a range of cost-effective ventilator oxygen sensor solutions designed to meet the demands of budget-constrained healthcare facilities. Our value-focused options ensure you can maintain essential patient care without compromising quality or performance. Explore our selection of high-quality refurbished units, gently used demo models, and robust entry-level systems that provide accurate and dependable oxygen monitoring. Each option is meticulously inspected and tested to guarantee operational excellence, empowering your medical teams with the tools they need to effectively manage patient ventilation.
| Option Type | Benefits | Ideal For |
|---|---|---|
| Refurbished Units | Significant cost savings, fully tested and certified. | Facilities prioritizing performance with strict budgets. |
| Demo Models | Near-new condition, substantial price reduction. | Clinics and hospitals seeking advanced features at a lower entry point. |
| Entry-Level Systems | Essential functionality, lowest initial investment. | Smaller clinics, transitional care units, or facilities with basic ventilation requirements. |
Value-Added Options Include:
- Certified Refurbished Ventilator Oxygen Sensors: Restored to original specifications and rigorously tested for optimal performance.
- Demo & Open-Box Models: Practically new units with minimal use, offered at significant savings.
- Entry-Level Systems: Cost-effective solutions providing essential functionality for general ventilation needs.
Verified Ventilator Oxygen Sensor Suppliers In Congo (Brazzaville)
When sourcing critical components like ventilator oxygen sensors in Congo (Brazzaville), reliability and trust are paramount. Franance Health stands out as your premier partner, offering unparalleled advantages to healthcare providers and medical equipment distributors.
Why choose Franance Health for your Ventilator Oxygen Sensor needs?
- Exclusive OEM Partnerships: We leverage our strong, established relationships with original equipment manufacturers (OEMs) to ensure you receive genuine, high-quality ventilator oxygen sensors that meet stringent industry standards. This direct sourcing minimizes the risk of counterfeit or substandard products, guaranteeing performance and patient safety.
- Dedicated Local Engineering Team: Our commitment extends beyond just supply. Franance Health boasts a skilled local engineering team in Congo (Brazzaville) who are readily available for installation support, calibration, troubleshooting, and ongoing maintenance of your ventilator oxygen sensors. This localized expertise ensures rapid response times and minimizes downtime.
- Comprehensive Warranty and Support: We stand behind the quality of our products. All ventilator oxygen sensors supplied by Franance Health come with a comprehensive warranty, providing you with peace of mind and protection against unforeseen issues. Our dedicated customer support is always on hand to address your inquiries and ensure seamless operation of your medical equipment.
Standard Configuration & Accessories
Each [Your Brand Name] Ventilator Oxygen Sensor, designed for critical care applications in Congo (Brazzaville), is meticulously packaged to ensure immediate deployment and comprehensive functionality. Our commitment is to provide a complete solution that meets the rigorous demands of healthcare professionals.
| Optional Accessory | Description | Availability in Congo (Brazzaville) |
|---|---|---|
| Extended Sensor Cables | For greater reach and flexibility in operating room setups. | Available upon request. |
| Calibration Gas | High-purity calibration gases for accurate sensor performance verification. | Available through authorized distributors. |
| Replacement Sensor Probes | To ensure continuous operation and minimize downtime. | Available for immediate dispatch. |
| Ventilator Interface Adapters | Specific adapters to ensure seamless integration with a wider range of ventilator models. | May be required depending on specific ventilator compatibility. |
| Power Adapter/UPS Compatibility Unit | While ventilators typically have integrated power solutions, compatible UPS units can be recommended for extended backup. | Consult your local sales representative for compatible recommendations. |
Typically Included in the Standard Package:
- Ventilator Oxygen Sensor Probe (Main Unit)
- Sensor Cable (with appropriate connectors for your specified ventilators)
- User Manual and Quick Start Guide
- Calibration Syringe or Calibration Gas Adapter
- Protective Carrying Case (for portable units or frequent relocation)
- Assorted Sensor Adhesives or Mounts (depending on probe type)
Warranty & Maintenance Plans
We understand the critical nature of reliable ventilator operation in healthcare settings across Congo (Brazzaville). Therefore, we offer comprehensive warranty and maintenance plans designed to ensure optimal performance and longevity for your ventilator oxygen sensors. Our standard warranty covers defects in materials and workmanship under normal operating conditions. For extended peace of mind and proactive care, we highly recommend our Preventive Maintenance Program (PPM). This program includes scheduled inspections, calibration, and cleaning by certified technicians, minimizing the risk of unexpected downtime. Furthermore, we maintain a robust inventory of genuine spare parts to facilitate prompt repairs and replacements, ensuring minimal disruption to your patient care services.
| Service Offering | Description | Availability in Congo (Brazzaville) |
|---|---|---|
| Standard Warranty | Covers manufacturing defects for a specified period. | Included with all new purchases. |
| Preventive Maintenance (PPM) | Scheduled inspections, calibration, and cleaning. | Available via on-site service contracts. |
| Spare Parts Availability | Access to genuine replacement parts. | Maintained locally for rapid dispatch. |
Key Features of Our Service Plans:
- Standard Manufacturer Warranty
- Optional Extended Warranty Packages
- Regularly Scheduled Preventive Maintenance (PPM)
- On-Demand Repair Services
- Certified Technical Support
- Genuine Spare Parts Availability
Frequently Asked Questions

Ready whenever you are
Let's discuss your Ventilator Oxygen Sensor in Congo (Brazzaville) requirements in Congo (Brazzaville).
Scaling healthcare logistics and technical systems across the entire continent.