X-Ray Tube Assembly in Chad
Leading X-Ray Tube Assembly Supplier
Buy X-Ray Tube Assembly in Chad. Top suppliers, installation, and warranty from Franance Health. Get a quote today.
Advanced Imaging
Delivers precise, high-resolution X-ray imaging for accurate diagnostic insights.
Robust Construction
Engineered with durable materials for reliable performance in demanding environments.
Enhanced Safety
Incorporates safety features to minimize radiation exposure for both patients and operators.
What Is An X-ray Tube Assembly?
The X-ray tube assembly is the critical heart of any X-ray imaging system. It is a vacuum-sealed glass or metal envelope containing a filament (cathode) and a target (anode). When a high voltage is applied, the filament heats up and emits electrons (thermionic emission). These electrons are then accelerated towards the anode at high speed. Upon striking the anode's focal spot, these electrons interact with the anode material, generating X-rays through two primary mechanisms: Bremsstrahlung (braking radiation) and characteristic radiation. These X-rays are then emitted and shaped by a collimator to direct them towards the patient for diagnostic imaging.
In Chad's healthcare landscape, reliable and efficient X-ray tube assemblies are fundamental for a wide range of diagnostic procedures. Their primary function is to produce the penetrating X-ray beam necessary to visualize internal anatomical structures. The intensity and energy spectrum of the emitted X-rays can be precisely controlled by adjusting the tube voltage (kVp) and current (mA), allowing clinicians to optimize image quality based on the specific examination.
| Key Component | Function |
|---|---|
| Cathode (Filament) | Emits electrons through thermionic emission. |
| Anode (Target) | Converts electron kinetic energy into X-rays. |
| Vacuum Envelope | Prevents arcing and preserves filament integrity. |
| Collimator | Shapes and restricts the X-ray beam. |
Key Clinical Applications in Chad:
- Orthopedic Imaging: Diagnosing fractures, dislocations, and bone abnormalities.
- Chest Imaging: Identifying pneumonia, tuberculosis, and other pulmonary conditions.
- Abdominal Imaging: Detecting organ abnormalities, foreign bodies, and fluid collections.
- Dental Imaging: Assessing tooth and jaw health.
- Fluoroscopy: Real-time imaging for procedures like barium swallows and angiography.
Who Needs X-ray Tube Assembly In Chad?
Reliable X-ray tube assemblies are critical for accurate diagnostic imaging across a wide spectrum of healthcare facilities in Chad. From large urban centers to remote rural clinics, the demand for robust and high-performing X-ray tube assemblies is consistent. These components are essential for a variety of medical specialties, ensuring that healthcare professionals have the tools they need to diagnose and treat a diverse range of conditions. Facilities that rely heavily on radiographic imaging for patient care will find the superior quality and longevity of our X-ray tube assemblies to be an invaluable asset.
| Department/Specialty | Primary Imaging Applications |
|---|---|
| Radiology/Diagnostic Imaging | General radiography (chest X-rays, bone imaging, abdominal X-rays), Fluoroscopy, Interventional radiology |
| Orthopedics | Fracture assessment, joint imaging, post-operative evaluation |
| Cardiology | Cardiac catheterization support, chest X-rays for cardiac conditions |
| Oncology | Tumor staging, monitoring treatment response |
| Emergency Medicine | Trauma imaging (fractures, dislocations, internal injuries), portable radiography |
| Pulmonology | Chest X-rays for pneumonia, tuberculosis, and other respiratory diseases |
| Pediatrics | Imaging of pediatric fractures and developmental abnormalities |
Key Facility Types and Departments Requiring X-Ray Tube Assemblies:
- University Teaching Hospitals and Large Medical Centers
- General Hospitals and Regional Medical Centers
- Specialized Clinics (e.g., Orthopedics, Cardiology, Oncology)
- Diagnostic Imaging Centers
- Rural and Community Health Clinics with Radiography Services
- Emergency and Trauma Centers
- Veterinary Clinics (for advanced imaging needs)
Installation Process For X-ray Tube Assembly
Ensuring the proper and safe installation of your new X-ray tube assembly in Chad is paramount for optimal performance and longevity. Our dedicated service team follows a rigorous process to guarantee a seamless integration with your existing X-ray system.
Site Preparation: Prior to delivery, our technicians will provide detailed specifications for the installation site. This includes requirements for ventilation, power supply, radiation shielding verification, and ensuring adequate space for equipment handling and technician access. Clients are responsible for ensuring the site meets these specifications, which will be confirmed during an initial site survey.
Delivery and Unpacking: The X-ray tube assembly will be transported by trained professionals to your facility. Upon arrival, the assembly is carefully unpacked in a controlled environment. Our team will conduct an immediate visual inspection to confirm there is no shipping damage. All packaging materials will be removed and disposed of responsibly.
Installation Steps: The installation involves several critical stages:
- System Integration: Safely disconnecting the old tube assembly (if applicable) and meticulously connecting the new X-ray tube assembly to the X-ray generator and control console.
- Mechanical Mounting: Securely mounting the new assembly to the collimator and gantry, ensuring proper alignment and stability.
- Electrical Connections: Making all necessary high-voltage and low-voltage electrical connections, adhering strictly to safety protocols and manufacturer guidelines.
- Cooling System Integration: Connecting and testing the integrated or external cooling system to maintain optimal operating temperatures.
- System Checks: Performing preliminary power-on tests and verifying all interlocks and safety features are functioning correctly.
Calibration Requirements: Post-installation, comprehensive calibration is essential. This involves:
- Initial Parameter Setting: Configuring the tube parameters within the X-ray generator to match the specifications of the new assembly.
- Exposure Calibration: Performing a series of test exposures to verify consistent radiation output, kVp accuracy, and mAs linearity.
- Image Quality Assessment: Evaluating image quality through phantom scans to ensure optimal contrast, resolution, and absence of artifacts.
- Record Keeping: Documenting all installation and calibration steps, including test results, for your service records and regulatory compliance.
Our team will conduct a thorough handover, providing training on basic operation and maintenance procedures relevant to the new X-ray tube assembly. We are committed to ensuring your facility in Chad is equipped for efficient and safe diagnostic imaging.
| Phase | Description |
|---|---|
| Site Preparation | Confirming all environmental and structural requirements are met. |
| Delivery & Unpacking | Secure transport and initial visual inspection for damage. |
| Installation | Mechanical and electrical integration with the X-ray system. |
| Calibration | Ensuring accurate radiation output and optimal image quality. |
Key Installation Considerations
- Adequate ventilation and power supply.
- Verification of radiation shielding.
- Sufficient space for access and handling.
- Pre-installation site survey confirmation.
How Much Is A X-ray Tube Assembly In Chad?
The cost of an X-ray tube assembly in Chad can vary significantly based on several factors, including the type of tube, its manufacturer, whether it's a new or refurbished unit, and the specific supplier. For new X-ray tube assemblies, you can expect prices to range broadly from approximately 1,500,000 to 4,000,000+ Central African CFA Francs (XAF). This wide range accounts for differences in tube technology, power ratings, and intended applications (e.g., general radiography, fluoroscopy, CT scanners).
Refurbished X-ray tube assemblies offer a more budget-friendly option. Prices for these can typically fall between 600,000 and 1,800,000 XAF. It's crucial to ensure that any refurbished unit comes with a reputable warranty and has undergone thorough testing to guarantee its performance and safety. When making a purchase, it's always recommended to obtain multiple quotes from different suppliers to secure the best value for your specific needs.
| Condition | Estimated Price Range (XAF) |
|---|---|
| New | 1,500,000 - 4,000,000+ |
| Refurbished | 600,000 - 1,800,000 |
Factors Influencing Price:
- New vs. Refurbished Unit
- Tube Manufacturer and Brand Reputation
- Tube Type and Specifications (e.g., power, focal spot size)
- Intended Medical Application
- Supplier and Import Costs
- Warranty and After-Sales Support
Affordable X-ray Tube Assembly Options
Understanding the financial considerations for healthcare providers in Chad, we offer a range of value-focused X-ray tube assembly solutions designed to maximize your investment. Whether you operate a high-volume clinic or a specialized diagnostic center with budget constraints, our selection ensures access to reliable imaging technology without compromising quality. Explore our cost-effective options:
Explore Our Value-Driven Solutions:
- Refurbished X-Ray Tube Assemblies: Expertly reconditioned and tested to meet stringent performance standards, our refurbished units provide a significant cost saving compared to new equipment. These assemblies are a smart choice for facilities seeking dependable imaging capabilities at a fraction of the price.
- Demonstration (Demo) Models: Gain access to virtually new technology with our demo models. These units have been used for demonstration purposes only and offer a blend of cutting-edge features and exceptional value. They are an ideal way to upgrade your imaging infrastructure while adhering to budgetary limits.
- Entry-Level Systems: For facilities requiring essential diagnostic imaging, our entry-level X-ray tube assemblies offer robust performance and essential features at an accessible price point. These systems are designed for reliability and ease of use, making them a practical solution for a variety of clinical needs.
Verified X-ray Tube Assembly Suppliers In Chad
For reliable and high-quality X-ray tube assemblies in Chad, Franance Health stands as your premier partner. We understand the critical nature of these components in diagnostic imaging and are committed to providing superior solutions. When you choose Franance Health, you benefit from:
Why Choose Franance Health for X-Ray Tube Assemblies:
- Exclusive OEM Partnerships: We maintain strong, direct relationships with leading Original Equipment Manufacturers (OEMs) of X-ray tube assemblies. This ensures that we supply genuine, high-performance components directly sourced from the creators, guaranteeing authenticity and adherence to the strictest quality standards.
- Dedicated Local Engineering Team: Our presence in Chad is backed by a skilled local engineering team. They possess in-depth knowledge of the unique healthcare landscape and technical requirements within the region. This allows us to offer tailored support, expert installation guidance, and prompt technical assistance, ensuring seamless integration and optimal performance of your X-ray tube assemblies.
- Comprehensive Warranty and Support: Franance Health provides robust warranty coverage on all X-ray tube assemblies. This peace of mind is further enhanced by our commitment to responsive after-sales support, including troubleshooting, maintenance advice, and timely replacement of parts when necessary. We aim to minimize your downtime and maximize the longevity of your equipment.
Standard Configuration & Accessories
When you receive your X-ray tube assembly in Chad, the standard configuration is designed to be a robust and complete solution for your imaging needs. Each assembly is meticulously packaged to ensure safe transit and immediate integration into your existing infrastructure. Our commitment is to provide you with a high-quality, reliable component ready for operation.
| Component Type | Typical Inclusion | Notes |
|---|---|---|
| Probes | Not Standard | Specific probes are typically part of imaging system accessories or specialized applications, not the core tube assembly itself. |
| Coils | Not Standard | Coils are generally associated with MRI or specialized imaging modalities, not standard X-ray tube assemblies. |
| Workstations | Not Standard | Workstations are separate components of the imaging system; the X-ray tube assembly is a power source. |
| UPS (Uninterruptible Power Supply) | Optional / Recommended | While not always in the box, a UPS is highly recommended for stable power and to protect the equipment from power fluctuations common in some regions. We can advise on suitable UPS solutions. |
| Control Interface Cables | Standard | Essential for connecting the tube assembly to the generator and imaging system. |
| Cooling Fluid | Standard | Pre-filled or provided in a sealed container for the integrated cooling system. |
Typically Included Components:
- High-performance X-ray Tube Assembly
- Cruciform Anode Assembly (if applicable)
- Pre-mounted Shielding
- Cooling System (e.g., oil circulation unit)
- Mounting Hardware and Brackets
- Standard Power and Signal Connectors
- Comprehensive User Manual and Installation Guide
- Quality Control and Test Report
Warranty & Maintenance Plans
We understand the critical nature of reliable X-ray equipment in your medical facility. Our X-ray Tube Assemblies in Chad come with robust warranty and maintenance plans designed to ensure maximum uptime and optimal performance. Each unit is backed by a comprehensive standard warranty, providing peace of mind against manufacturing defects. Beyond the initial coverage, we offer flexible Extended Warranty options tailored to your operational needs. To further safeguard your investment and minimize the risk of unexpected downtime, we highly recommend our Preventive Maintenance Programs (PPM). These proactive service agreements are crucial for identifying and addressing potential issues before they escalate, ensuring your X-ray tube assembly operates at peak efficiency and longevity. Our dedicated service team in Chad is equipped to perform regular inspections, calibrations, and necessary adjustments as part of your PPM schedule. Furthermore, we maintain a strong commitment to spare parts availability, ensuring that any required components for repairs or replacements are readily accessible, minimizing turnaround times and keeping your diagnostic capabilities operational.
| Plan Type | Coverage Details | Ideal For |
|---|---|---|
| Standard Warranty | Covers manufacturing defects for a specified period. | All new X-ray Tube Assemblies. |
| Extended Warranty | Optional extension of standard warranty coverage. | Facilities seeking extended protection beyond the initial period. |
| Preventive Maintenance Program (PPM) | Scheduled inspections, cleaning, calibration, and minor adjustments. | All medical facilities aiming for optimal performance and uptime. |
| On-Demand Service & Spare Parts | Prompt response for repairs and immediate availability of genuine parts. | All users requiring rapid resolution to equipment issues. |
Key Benefits of Our Plans:
- Extended equipment lifespan through proactive care.
- Reduced risk of costly emergency repairs.
- Guaranteed access to genuine spare parts.
- On-site support from certified technicians in Chad.
- Predictable budgeting for maintenance costs.
Frequently Asked Questions

Ready whenever you are
Let's discuss your X-Ray Tube Assembly in Chad requirements in Chad.
Scaling healthcare logistics and technical systems across the entire continent.