
MRI RF Cage (Faraday Cage) Installation & Testing Service in Cameroon
Engineering Excellence & Technical Support
MRI RF Cage (Faraday Cage) Installation & Testing Service High-standard technical execution following OEM protocols and local regulatory frameworks.
Optimized RF Shielding Performance
We guarantee superior electromagnetic interference (EMI) shielding for your MRI RF cage installation in Cameroon, ensuring optimal image quality and patient safety by preventing external radiofrequency signals from entering the scan room. Our installations meet and exceed international standards.
Comprehensive RF Penetration Testing
Our specialized testing services in Cameroon employ advanced techniques to rigorously assess the integrity and attenuation of your MRI RF cage. We identify and rectify any potential signal leakage points, ensuring the highest level of RF shielding effectiveness and compliance.
Expert Regulatory Compliance & Certification
Navigate Cameroon's regulatory landscape with confidence. Our experienced team provides expert guidance and thorough testing to ensure your MRI RF cage installation meets all relevant national and international compliance requirements, securing necessary certifications for seamless operation.
What Is Mri Rf Cage (Faraday Cage) Installation & Testing Service In Cameroon?
MRI Radiofrequency (RF) Cage, commonly referred to as a Faraday Cage, installation and testing service in Cameroon encompasses the specialized process of designing, constructing, and verifying electromagnetic shielding for Magnetic Resonance Imaging (MRI) suites. This service is critical for ensuring optimal MRI image quality by preventing external RF signals from interfering with the sensitive MR scanner and its data acquisition. The installation involves meticulous engineering and construction techniques to create a continuous conductive enclosure. Testing, a rigorous post-installation procedure, quantifies the cage's shielding effectiveness across the relevant RF spectrum. This service is indispensable for any facility acquiring or upgrading an MRI scanner within Cameroon.
| Who Needs MRI RF Cage Installation & Testing Service? | Typical Use Cases | ||||
|---|---|---|---|---|---|
| Hospitals and Medical Centers acquiring or upgrading MRI scanners. | Diagnostic Imaging Departments in hospitals. | Radiology Clinics specializing in advanced imaging. | Research Institutions utilizing MRI for scientific studies. | Veterinary Hospitals with advanced diagnostic imaging capabilities. | Governmental health facilities. |
| Ensuring diagnostic image quality and accuracy for clinical decision-making. | Preventing RF interference that can lead to image artifacts, noise, and inaccurate diagnoses. | Protecting the sensitive MR scanner hardware from external electromagnetic pollution. | Meeting stringent regulatory and manufacturer requirements for MRI installations. | Facilitating advanced MRI techniques such as functional MRI (fMRI) and diffusion tensor imaging (DTI), which are highly susceptible to RF noise. | Maintaining a safe and efficient operating environment for MRI suites. |
Key Components and Processes of MRI RF Cage Installation & Testing Service:
- Site Assessment & Design: Evaluating the MRI suite's spatial constraints, identifying potential RF ingress points, and developing a customized cage design based on electromagnetic shielding principles and patient safety standards.
- Material Selection: Utilizing highly conductive materials such as copper, aluminum, or specialized perforated panels, chosen for their specific RF attenuation properties and structural integrity.
- Construction & Fabrication: Precision assembly of cage panels, doors, windows, and ventilation systems, ensuring a hermetic seal to prevent RF leakage. This includes specialized RF-gasketed doors and filtered ventilation, which are crucial for maintaining the integrity of the shielding.
- Electrical Grounding & Bonding: Implementing a robust grounding and bonding system to dissipate static electricity and stray RF currents, preventing them from accumulating and causing interference.
- RF Shielded Doors & Windows: Installation of specialized doors and windows designed to maintain the RF shielding integrity of the cage, typically incorporating multiple layers of conductive mesh and specialized seals.
- RF Filtered Ventilation: Integration of RF-filtered ventilation systems to ensure adequate airflow for cooling the MRI equipment and maintaining patient comfort without compromising the shielding effectiveness.
- Waveguide & Cable Entry Management: Implementing RF-tight solutions for all necessary penetrations, including waveguide installations for RF transmission and entry points for power, data, and other essential cables, using specialized connectors and filters.
- Post-Installation RF Attenuation Testing: Conducting standardized tests using calibrated RF signal generators and receivers to measure the cage's attenuation performance at various frequencies within the relevant MR scanner operating spectrum (e.g., 1.5T, 3T). This typically involves sweep tests and single-frequency attenuation measurements.
- Shielding Effectiveness Verification: Analyzing test data to confirm that the RF cage meets or exceeds the required shielding effectiveness specifications (often measured in decibels, dB) as stipulated by equipment manufacturers and international standards.
- Certification & Reporting: Providing comprehensive documentation, including design specifications, installation records, and detailed RF attenuation test reports, often leading to a certification of compliance.
Who Needs Mri Rf Cage (Faraday Cage) Installation & Testing Service In Cameroon?
The installation and testing of MRI RF cages (Faraday cages) are crucial for ensuring the optimal performance and safety of Magnetic Resonance Imaging (MRI) scanners. These specialized shielded rooms block external radio frequency (RF) interference, which can degrade image quality and compromise diagnostic accuracy. In Cameroon, the demand for these services is growing as healthcare infrastructure advances and more advanced medical imaging capabilities become available. This service caters to facilities that operate or plan to install MRI machines, requiring a protected environment for their sensitive equipment.
| Customer Type | Key Departments Involved | Specific Needs/Reasons for Service |
|---|---|---|
| Hospitals (Public and Private) | Radiology Department, Imaging Department, Facilities Management, Biomedical Engineering | To ensure high-quality MRI scans for diagnosis, patient safety, protect expensive MRI equipment from RF interference, comply with manufacturer specifications. |
| Specialty Clinics (Radiology Centers) | Radiology Department, Technical Operations, Management | To provide specialized MRI services, maintain competitive edge, ensure diagnostic accuracy for referred patients, optimize equipment lifespan. |
| Research Institutions & Universities | Medical Research Departments, Radiology/Imaging Faculty, Facilities and Infrastructure Management | For conducting advanced medical research requiring precise imaging, training medical professionals, ensuring reproducibility of research findings. |
| Medical Equipment Suppliers & Installers | Technical Services Department, Project Management, Sales (in collaboration with RF cage providers) | To offer comprehensive MRI installation solutions, guarantee successful integration of MRI scanners with RF shielded rooms, fulfill contractual obligations. |
| Government Healthcare Agencies | Public Health Infrastructure Development Units, Ministry of Health, Regional Health Authorities | To equip public hospitals with advanced diagnostic capabilities, improve access to MRI services for the general population, standardize imaging quality across public health facilities. |
Target Customers and Departments for MRI RF Cage Installation & Testing Services in Cameroon
- Hospitals (Public and Private)
- Specialty Clinics (e.g., Radiology Centers, Diagnostic Imaging Centers)
- Research Institutions & Universities with Medical Departments
- Medical Equipment Suppliers and Installers
- Government Healthcare Agencies (for public health facilities)
Mri Rf Cage (Faraday Cage) Installation & Testing Service Process In Cameroon
This document outlines the comprehensive workflow for MRI RF Cage (Faraday Cage) installation and testing services in Cameroon, from the initial client inquiry to the final project execution and handover. Our process emphasizes meticulous planning, expert execution, and rigorous testing to ensure optimal MRI performance and compliance with international standards.
| Phase | Activity | Description | Key Deliverables/Outcomes |
|---|---|---|---|
| Phase 1: Inquiry & Initial Consultation | Client Inquiry & Needs Assessment | Client contacts us with a requirement for MRI RF cage installation. We gather initial information about the project scope, location, MRI equipment, and specific needs. | Understanding of client requirements, preliminary project scope defined. |
| Initial Consultation | A meeting (virtual or in-person) with the client to discuss the project in detail, answer questions, and explain our service offering. This may involve preliminary discussions on site access and constraints. | Client engagement, clarification of service capabilities, initial project feasibility assessment. | |
| Phase 2: Site Assessment & Design | Site Survey & Measurement | Our expert team conducts a thorough site survey at the intended MRI room location in Cameroon. This includes precise measurements of dimensions, existing infrastructure, potential interference sources, and structural considerations. | Detailed site survey report, precise room dimensions, identification of potential challenges. |
| RF Cage Design & Engineering | Based on the site assessment and MRI manufacturer's specifications, our engineers design a custom RF cage solution. This includes material selection, structural integrity, ventilation, power filtering, and signal penetration strategies. | Detailed RF cage design blueprints, material specifications, engineering drawings. | |
| Phase 3: Quotation & Contract | Proposal & Quotation Generation | A comprehensive proposal is prepared, outlining the scope of work, design details, materials, timeline, and associated costs. A detailed quotation is then provided to the client. | Formal proposal document, detailed cost breakdown, estimated project timeline. |
| Contract Negotiation & Signing | Discussions and negotiation of contract terms and conditions. Upon agreement, the contract is signed by both parties, formalizing the project. | Signed service contract, mutual understanding of project obligations. | |
| Phase 4: Procurement & Preparation | Material Procurement | All necessary high-quality RF shielding materials, components, and specialized equipment are procured from reputable suppliers, ensuring compliance with international standards. | Procured and verified RF shielding materials and components. |
| Site Preparation & Logistics | Coordination of logistics for material delivery to Cameroon, site access permits, and preparation of the installation area, including any necessary temporary structural modifications. | Materials delivered to site, site access secured, installation area prepared. | |
| Phase 5: Installation | RF Cage Construction | Our skilled technicians meticulously construct the RF cage according to the approved design. This involves precise fabrication, assembly, and integration of all components, including doors, windows, waveguides, and ventilation systems. | Physically constructed RF cage structure. |
| Integration of RF Penetrations | Installation of specialized RF-shielded penetrations for power, data, ventilation, and other services, ensuring signal integrity and shielding effectiveness. | All service penetrations integrated and shielded. | |
| Phase 6: Shielding Effectiveness Testing | Pre-Testing Preparations | Calibration of testing equipment and preparation of the RF cage for rigorous testing. This may involve disabling non-essential services to ensure accurate readings. | Testing equipment calibrated, test environment prepared. |
| RF Shielding Effectiveness Measurement | Utilizing state-of-the-art equipment, we conduct comprehensive RF shielding effectiveness testing across a wide range of frequencies (typically 1 MHz to 10 GHz) as per international standards (e.g., IEEE 299, ASTM F1897). | Raw shielding effectiveness data recorded. | |
| Data Analysis & Reporting | The collected data is analyzed to assess the RF cage's performance against specified requirements. A detailed test report is generated, documenting the results and any observations. | Comprehensive RF shielding effectiveness test report. | |
| Phase 7: Final Inspection & Handover | Client Walkthrough & Inspection | The client is invited to conduct a final walkthrough and inspection of the completed RF cage. Any minor adjustments or clarifications are addressed. | Client satisfaction with the installed RF cage. |
| Project Handover & Documentation | Formal handover of the project to the client. This includes all design documents, test reports, maintenance guidelines, and warranty information. | Complete project documentation delivered, project officially handed over. | |
| Phase 8: Post-Installation Support | Warranty & Maintenance | Provision of warranty coverage for the installed RF cage and offering ongoing maintenance services to ensure continued optimal performance. | Ongoing support and assurance of long-term performance. |
| Troubleshooting & Support | Availability of technical support for any post-installation queries or issues that may arise. | Prompt resolution of any client concerns. |
MRI RF Cage Installation & Testing Service Process in Cameroon
- Phase 1: Inquiry & Initial Consultation
- Phase 2: Site Assessment & Design
- Phase 3: Quotation & Contract
- Phase 4: Procurement & Preparation
- Phase 5: Installation
- Phase 6: Shielding Effectiveness Testing
- Phase 7: Final Inspection & Handover
- Phase 8: Post-Installation Support
Mri Rf Cage (Faraday Cage) Installation & Testing Service Cost In Cameroon
Installing an MRI Radio Frequency (RF) Cage, also known as a Faraday Cage, is a critical and highly specialized process essential for ensuring the diagnostic integrity and safety of Magnetic Resonance Imaging (MRI) equipment. The cost of this service in Cameroon is influenced by several key factors, leading to a range of potential pricing. These factors include the size and complexity of the MRI suite, the materials used for the cage construction (e.g., copper, aluminum, steel), the existing building structure and its suitability for modification, the level of shielding required (specific dB attenuation), the need for specialized ventilation and electrical grounding, and the expertise and reputation of the installation company. Furthermore, logistical challenges within Cameroon, such as transportation of specialized materials and availability of skilled technicians, can also impact the overall cost. Clients can expect a significant investment, reflecting the precision engineering and specialized knowledge required.
| Service Component | Estimated Cost Range (XAF) | Notes |
|---|---|---|
| Consultation & Design | 500,000 - 2,000,000+ | Initial assessment, site survey, and detailed cage design. |
| Material Procurement (Cage Construction) | 5,000,000 - 25,000,000+ | Varies significantly based on material (copper, aluminum, steel) and coverage area. |
| Installation Labor & Expertise | 7,000,000 - 30,000,000+ | Includes specialized technicians, welding, assembly, and finishing. |
| RF Shielded Doors & Windows | 2,000,000 - 8,000,000+ per unit | Highly specialized components crucial for maintaining shielding integrity. |
| Ventilation & RF Filtering | 1,500,000 - 6,000,000+ | Installation of specialized, shielded ventilation systems. |
| Electrical Grounding & Power Filtering | 800,000 - 3,000,000+ | Ensuring safe and interference-free electrical systems. |
| Testing & Certification | 1,000,000 - 4,000,000+ | RF leakage testing, field uniformity tests, and final certification. |
| Contingency & Project Management | 10% - 20% of total | For unforeseen issues and overall project oversight. |
| Total Estimated Project Cost (Small to Medium MRI Suite) | 20,000,000 - 70,000,000+ | This is a broad estimate and can vary significantly. |
| Total Estimated Project Cost (Large/Complex MRI Suite) | 70,000,000 - 150,000,000+ | For larger facilities or highly specialized requirements. |
Key Factors Influencing MRI RF Cage Installation & Testing Costs in Cameroon
- Size and Volume of the MRI Suite: Larger rooms require more material and labor.
- Complexity of the Cage Design: Multi-room shielding or intricate architectural integration increases costs.
- Material Selection: Copper offers superior shielding but is more expensive than aluminum or steel.
- Required Shielding Attenuation (dB): Higher attenuation levels necessitate more robust construction and materials.
- Existing Building Infrastructure: Modifications to walls, floors, and ceilings can add significant expense.
- Ventilation and RF-Filtered Systems: Specialized HVAC systems to maintain airflow without compromising shielding.
- Electrical Grounding and Power Filtering: Essential for safety and preventing RF interference.
- Door and Window Specifications: RF-shielded doors and windows are specialized and costly.
- Logistical Challenges: Transportation of materials and personnel, particularly in remote areas.
- Installer's Expertise and Reputation: Highly experienced and certified companies command higher fees.
- Testing and Certification: Rigorous testing is required to ensure compliance with international standards.
- Project Management and Supervision: Overhead costs associated with managing the installation process.
Affordable Mri Rf Cage (Faraday Cage) Installation & Testing Service Options
Our affordable MRI RF cage (Faraday cage) installation and testing service provides a comprehensive solution to ensure optimal MRI performance and patient safety. We understand the significant investment a Magnetic Resonance Imaging (MRI) system represents, and protecting that investment with a properly functioning RF cage is paramount. Our services are designed to be cost-effective, offering various value bundles and strategic cost-saving measures to meet diverse budget requirements.
| Value Bundle | Description | Includes | Cost Savings |
|---|---|---|---|
| Basic Shielding Package | Essential RF cage installation for standard MRI requirements. | On-site assessment, RF cage design, fabrication, installation, and basic RF leakage testing. | Standardized materials and efficient installation process minimize labor costs. |
| Performance Plus Bundle | Enhanced shielding for critical imaging applications and improved signal-to-noise ratio. | Includes Basic Shielding Package plus advanced shielding materials, comprehensive multi-point RF testing, and initial performance validation. | Proactive identification of potential issues reduces future costly rework. Optimized shielding can improve scan times, indirectly saving operational costs. |
| Full Lifecycle Service | End-to-end solution from initial installation through ongoing maintenance and upgrades. | Includes Performance Plus Bundle plus annual preventative maintenance, remote monitoring options, and priority support for upgrades or repairs. | Bundled pricing offers significant discounts over individual service calls. Predictable maintenance costs prevent unexpected major expenditures. Reduced downtime due to proactive maintenance. |
| Decommission & Relocate Special | Cost-effective solution for moving an existing MRI and its RF cage. | Disassembly of existing RF cage, safe transport, site preparation at new location, reassembly, and re-testing of RF cage. | Streamlined process and specialized equipment for efficient relocation minimize labor and downtime costs. Avoids the expense of building a new cage from scratch. |
Key Service Offerings:
- Professional RF Cage Installation: Expert design and construction to meet stringent MRI shielding requirements.
- Comprehensive RF Cage Testing: Utilizing advanced equipment to verify shielding effectiveness and identify potential RF leakage.
- Decommissioning and Relocation Services: Safe and efficient removal and reinstallation of existing RF cages.
- Shielding Upgrades and Modifications: Enhancements to existing cages to meet new technology or regulatory standards.
- Certification and Compliance Reporting: Detailed documentation for regulatory bodies and internal records.
- Preventative Maintenance Packages: Regular inspections and tune-ups to ensure continued optimal performance.
Verified Providers In Cameroon
In Cameroon's evolving healthcare landscape, identifying reliable and accredited medical professionals is paramount. Franance Health has emerged as a trusted name, meticulously vetting and endorsing providers who meet stringent quality and ethical standards. This dedication to verification ensures that patients can access safe, effective, and compassionate care. Understanding the Franance Health credentialing process illuminates why these providers stand out as the superior choice for your health needs.
| Benefit for Patients | Why Franance Health Providers Excel |
|---|---|
| Peace of Mind and Trust | Franance Health's rigorous verification process eliminates guesswork, providing confidence in the quality of care received. |
| Access to Competent Professionals | Verified providers demonstrate a commitment to high standards of medical practice and ethical conduct. |
| Enhanced Patient Safety | The meticulous screening process minimizes risks associated with unqualified or unaccredited providers. |
| Improved Health Outcomes | By partnering with skilled and experienced practitioners, patients are more likely to achieve positive health results. |
| Streamlined Healthcare Navigation | Franance Health acts as a reliable guide, simplifying the process of finding trustworthy medical services. |
Key Components of Franance Health Provider Verification:
- Licensure and Accreditation Checks: Rigorous examination of all required medical licenses and institutional accreditations to ensure they are current and valid.
- Professional Qualifications Review: Detailed assessment of educational background, specialization, and ongoing professional development of healthcare practitioners.
- Experience and Track Record Analysis: Evaluation of clinical experience, patient outcomes, and adherence to best practices.
- Background Checks and Ethical Compliance: Thorough screening for any disciplinary actions, malpractice claims, or ethical violations.
- Infrastructure and Resource Assessment: Verification of adequate facilities, equipment, and support staff for optimal patient care.
Scope Of Work For Mri Rf Cage (Faraday Cage) Installation & Testing Service
This Scope of Work (SOW) outlines the requirements for the professional installation and comprehensive testing of an MRI Radio Frequency (RF) Cage (also known as a Faraday Cage) at the designated facility. The objective is to ensure the RF cage meets all necessary performance standards for optimal MRI operation, preventing external RF interference and minimizing internal RF leakage.
| Section | Description | Technical Deliverables | Standard Specifications |
|---|---|---|---|
| Detailed planning, scheduling, and coordination of all installation and testing activities. This includes site surveys, design review, risk assessment, and communication protocols. | Project schedule, communication plan, risk management plan, site preparation checklist. | Adherence to project management best practices (e.g., PMI). Compliance with facility-specific safety and access protocols. Review and approval of final RF cage design drawings. |
| Review and verification of the RF cage design documentation provided by the MRI vendor or RF cage manufacturer to ensure it meets all performance and structural requirements. | Design review report, compliance matrix against vendor specifications. | MRI vendor's RF cage design specifications (e.g., attenuation levels for various frequencies, material requirements, door and window specifications). Relevant industry standards (e.g., IEC, IEEE). |
| Procurement and delivery of all necessary RF shielding materials, including conductive panels, mesh, gaskets, filters, wave guides, and fasteners. Ensuring materials are free from defects and meet specifications. | Material submittals, material quality control reports, delivery manifests. | Materials specified in the approved RF cage design. Compliance with fire retardancy and environmental standards where applicable. Proper handling and storage of sensitive RF components. |
| Installation of the RF cage structure, including walls, ceiling, floor, and any necessary modifications to the existing building structure. This includes precise assembly and sealing to ensure RF integrity. | As-built drawings, installation progress reports, photographic documentation of key installation stages. | Adherence to approved RF cage design and shop drawings. Precision installation to ensure gapless shielding. Proper grounding and bonding of all conductive components. Compliance with local building codes and regulations. Integration of power and data filters, RF-sealed windows, and RF-sealed doors. |
| Installation of RF-sealed doors and windows, ensuring proper fit, sealing, and functionality. This includes any interlocks or safety mechanisms. | Door and window installation verification reports, operational check records. | MRI vendor's specifications for RF doors and windows. Performance of specified RF attenuation. Smooth and secure operation of doors and windows. |
| Installation of RF-filtered power, data, and ventilation systems to maintain RF integrity while allowing for necessary services. This includes wave guides for ventilation. | Installation records for filters and wave guides, continuity testing of filtered connections. | Correct type and rating of RF filters as per design. Proper installation of wave guides for ventilation openings. Ensuring all penetration points are RF-sealed. |
| Implementation of a comprehensive grounding and bonding system for the entire RF cage structure to ensure electrical safety and RF performance. | Grounding and bonding schematic, continuity test results. | Compliance with electrical codes and RF shielding best practices. Low impedance path to earth ground. |
| Comprehensive testing of the RF cage's shielding effectiveness across the relevant MRI frequency spectrum. This includes measurements of attenuation in various locations and orientations. | RF shielding effectiveness test report (including raw data and summary), attenuation curves, pass/fail analysis against specifications. | Pre-commissioning and post-commissioning testing. Testing conducted by a qualified and independent third-party RF testing company. Minimum required attenuation levels as specified by the MRI manufacturer (typically > 100 dB across the relevant frequency range). Testing procedures as per relevant standards (e.g., IEC 60386). |
| Testing to ensure the RF cage does not interfere with other sensitive electronic equipment within the facility and vice-versa. | EMC test report (if specified). | Relevant EMC standards (e.g., IEC 61000 series). |
| Final inspection, troubleshooting, and handover of the completed RF cage to the client. This includes user training on any specific operational aspects. | Final acceptance certificate, user manual (for RF cage specific maintenance), warranty documentation. | Successful completion of all testing and verification. Client sign-off on the completed installation. Provision of all project documentation and warranties. |
Key Objectives
- To meticulously install a high-performance RF cage that attenuates external RF signals to meet or exceed MRI manufacturer specifications.
- To ensure the structural integrity and longevity of the RF cage, adhering to all relevant building codes and safety regulations.
- To perform rigorous testing and commissioning of the RF cage to verify its RF shielding effectiveness.
- To provide comprehensive documentation of the installation process, test results, and compliance with specifications.
- To ensure minimal disruption to ongoing facility operations during the installation and testing phases.
Service Level Agreement For Mri Rf Cage (Faraday Cage) Installation & Testing Service
This Service Level Agreement (SLA) outlines the terms and conditions for the MRI RF Cage (Faraday Cage) Installation & Testing Service, focusing on response times for incidents and uptime guarantees for the installed and tested RF cage. This SLA aims to ensure the reliable performance and rapid resolution of any issues related to the RF cage's shielding integrity.
| Service Level | Description | Response Time (Business Hours) | Resolution Time (Target) | Uptime Guarantee |
|---|---|---|---|---|
| Critical Incident (Shielding Failure) | Complete or significant degradation of RF shielding affecting MRI operation. | 2 Business Hours | 8 Business Hours | N/A (Focus on rapid resolution) |
| High Priority Incident (Performance Degradation) | Noticeable degradation of RF shielding impacting image quality or increasing noise levels, but MRI operation is still possible with limitations. | 4 Business Hours | 24 Business Hours | N/A (Focus on timely resolution) |
| Medium Priority Incident (Minor Anomaly/Intermittent Issue) | Minor RF shielding anomalies detected during testing or occasional intermittent issues that do not immediately impact MRI operation. | 8 Business Hours | 72 Business Hours | N/A (Focus on scheduled resolution) |
| Low Priority Incident (Request/Inquiry) | General inquiries, requests for documentation, or minor non-critical issues. | 24 Business Hours | As agreed upon, typically within 5 Business Days | N/A |
| Installation & Testing Service | Initial installation and commissioning of a new RF cage. | N/A (Pre-scheduled) | As per project timeline | N/A (Focus on initial successful commissioning) |
| Preventative Maintenance | Scheduled check-ups and minor adjustments to maintain RF cage integrity. | N/A (Pre-scheduled) | As per maintenance schedule | N/A (Focus on proactive prevention) |
Scope of Service
- Installation of new MRI RF cages.
- Retrofitting and upgrading of existing MRI RF cages.
- Comprehensive performance testing and certification of RF cage shielding.
- Scheduled preventative maintenance for RF cage integrity.
- Troubleshooting and repair of RF cage shielding anomalies.
- Post-installation support and consultancy.
Frequently Asked Questions

Ready when you are
Let's scope your MRI RF Cage (Faraday Cage) Installation & Testing Service in Cameroon project in Cameroon.
Scaling healthcare logistics and technical systems across the entire continent.

