Certified Biosafety
Provides certified Class II biological safety for personnel, product, and environmental protection against airborne contaminants.
HEPA Filtration
Features advanced HEPA filtration to capture microscopic particles, ensuring sterile working conditions and clean exhaust air.
Reliable Operation
Designed for robust and reliable performance with stable airflow, critical for demanding laboratory applications in resource-limited settings.
What Is A Microbiology Safety Cabinet (Class Ii)?
A Microbiology Safety Cabinet (Class II), often referred to as a biological safety cabinet (BSC), is a vital piece of laboratory equipment designed to protect both the user and the environment from potential biohazards. In healthcare settings across Burkina Faso, these cabinets are indispensable for safely manipulating infectious agents, cell cultures, and other potentially hazardous biological materials. Class II cabinets achieve this protection through a meticulously controlled airflow system that draws airborne particles away from the operator and the workspace, filtering them through high-efficiency particulate air (HEPA) filters before exhausting the air. This creates a sterile work environment essential for preventing cross-contamination and ensuring the integrity of sensitive research and diagnostic procedures.
| Feature | Benefit in Burkina Faso Context |
|---|---|
| HEPA Filtration | Ensures a high level of protection against airborne pathogens prevalent in tropical climates, reducing infection risk for healthcare workers. |
| Sterile Workspace | Guarantees reliable diagnostic results by preventing sample contamination, critical for accurate disease identification and treatment planning. |
| Controlled Airflow | Minimizes the spread of infectious agents within healthcare facilities, contributing to overall infection control efforts. |
Key Functions and Clinical Applications:
- Personnel Protection: Prevents exposure of laboratory personnel to aerosols and droplets containing infectious microorganisms.
- Product Protection: Creates a sterile environment to prevent contamination of cultures, samples, and sensitive reagents.
- Environmental Protection: Filters exhaust air to remove potentially harmful microorganisms, safeguarding the surrounding environment.
- Diagnostic Testing: Crucial for handling patient samples in microbiology and virology labs for pathogen identification and susceptibility testing.
- Cell Culture Work: Essential for maintaining sterile conditions in cell culture laboratories for research and therapeutic development.
- Molecular Diagnostics: Supports the safe manipulation of nucleic acids and reagents in PCR and other molecular diagnostic procedures.
Who Needs Microbiology Safety Cabinet (Class Ii) In Burkina Faso?
In Burkina Faso, a Class II Microbiology Safety Cabinet is an essential piece of equipment for a wide range of facilities where biological agents are handled. Its primary role is to protect both the personnel and the environment from exposure to infectious aerosols and microorganisms, while also safeguarding the sample from contamination. This makes it indispensable for laboratories involved in diagnostic, research, and quality control activities.
Key Facilities and Departments Requiring a Class II Safety Cabinet:
- National and Regional Hospitals: Particularly those with dedicated microbiology, virology, and infectious disease departments for diagnostic testing and outbreak investigations.
- University Teaching Hospitals: Supporting both clinical diagnostics and research activities, often involving the study of emerging infectious diseases prevalent in the region.
- Public Health Laboratories: Crucial for disease surveillance, pathogen identification, and public health interventions, especially for diseases like malaria, HIV, and other prevalent infections.
- Research Institutions and Universities: Conducting studies on infectious agents, developing diagnostic tools, or undertaking public health research that requires safe handling of biological samples.
- Veterinary Diagnostic Laboratories: For the diagnosis of zoonotic diseases and animal pathogens that pose a risk to human health.
- Food and Water Quality Control Laboratories: Ensuring the safety of consumables by testing for microbial contamination.
- Specialized Clinics: Particularly those offering advanced diagnostic services or involved in infectious disease management, such as HIV/AIDS clinics or tuberculosis centers.
Installation Process For Microbiology Safety Cabinet (Class Ii)
Ensuring the optimal performance and safety of your Class II Microbiology Safety Cabinet in Burkina Faso begins with a meticulous installation process. Our certified technicians will guide you through each step, from initial site preparation to final calibration, guaranteeing compliance with international safety standards and efficient operation within your laboratory environment.
Site Preparation: Prior to delivery, a suitable location must be identified. This area should be free from excessive dust, vibrations, and drafts, and have adequate electrical power supply conforming to the cabinet's specifications. Access for delivery and installation, including sufficient doorway clearance, must be confirmed. Ventilation requirements, including proximity to exhaust systems if external venting is planned, will also be assessed.
Delivery and Unpacking: Upon arrival, our team will carefully transport the cabinet to its designated location. The cabinet will be thoroughly inspected for any transit damage before unpacking. All packaging materials will be removed, and the cabinet will be positioned according to the prepared site plan.
Installation Steps: The installation involves connecting the cabinet to the power supply, ensuring proper grounding, and, if applicable, connecting to an external exhaust system. Our technicians will verify all electrical connections are secure and meet safety regulations. For cabinets with recirculating airflow, internal fan and filter integrity will be checked. The cabinet will be leveled to ensure stable operation and optimal airflow dynamics. Basic functional checks will be performed to confirm power-up and initial system response.
Calibration Requirements: Post-installation, a comprehensive calibration is essential. This process involves verifying and adjusting critical airflow parameters, including downflow velocity, inflow velocity, and exhaust airflow (if applicable). Filter integrity testing (e.g., HEPA filter leak testing) will be conducted to ensure the highest level of biological containment. Airflow patterns will be visualized and measured to confirm containment effectiveness and operator protection. These calibrations are vital for validating the cabinet's performance against relevant standards (e.g., NSF/ANSI 49 or EN 12469) and are documented thoroughly for your records.
| Parameter | Required Value (Typical) | Testing Method |
|---|---|---|
| Downflow Velocity | 0.4 - 0.6 m/s | Anemometer / Smoke Test |
| Inflow Velocity | 0.5 m/s | Anemometer / Smoke Test |
| HEPA Filter Leakage | < 0.01% | MPPS (Most Penetrating Particle Size) method |
| Noise Level | < 60 dBA | Sound Level Meter |
Key Installation Stages:
- Site assessment and preparation
- Cabinet delivery and unpacking
- Electrical connection and grounding
- Exhaust system integration (if applicable)
- Leveling and final positioning
- Initial functional checks
- Downflow and inflow velocity calibration
- HEPA filter integrity testing
- Airflow pattern verification
- Comprehensive documentation and handover
How Much Is A Microbiology Safety Cabinet (Class Ii) In Burkina Faso?
The investment in a Class II Microbiology Safety Cabinet for your laboratory in Burkina Faso will vary depending on whether you opt for a brand-new unit or a refurbished model. Factors such as brand reputation, specific features, warranty, and the supplier's location and services will also influence the final price. Given the current economic landscape and import logistics, it's essential to obtain direct quotes from reputable medical equipment suppliers operating within or serving Burkina Faso.
New Class II Microbiology Safety Cabinets typically represent a significant investment. Expect prices to range broadly, reflecting the advanced technology, safety certifications, and manufacturer warranties they come with. These units are designed for optimal performance and longevity, offering peace of mind for critical laboratory operations.
Refurbished Class II Microbiology Safety Cabinets can offer a more budget-friendly alternative. These cabinets have been previously used, but have undergone rigorous inspection, servicing, and often have components replaced to ensure they meet functional and safety standards. While generally less expensive, it's crucial to verify the extent of refurbishment, the supplier's reputation for quality control, and the warranty provided.
For accurate pricing, we strongly advise contacting several trusted medical equipment vendors in Burkina Faso. They can provide detailed specifications, current pricing, and discuss delivery and installation options tailored to your specific needs.
| Cabinet Type | Estimated Price Range (XOF) |
|---|---|
| New Class II Microbiology Safety Cabinet | 5,000,000 - 15,000,000+ |
| Refurbished Class II Microbiology Safety Cabinet | 2,000,000 - 7,000,000 |
Factors Influencing Price:
- New vs. Refurbished Status
- Brand and Manufacturer Reputation
- Specific Technical Features and Specifications
- Included Warranty and Service Packages
- Supplier's Location and Logistics Costs
- Customization or Additional Accessories
Affordable Microbiology Safety Cabinet (Class Ii) Options
Recognizing the unique budgetary considerations for healthcare facilities in Burkina Faso, we offer a range of value-focused Microbiology Safety Cabinet (Class II) solutions. These options are designed to provide robust biosafety protection without compromising essential performance, making critical laboratory work accessible to a wider range of institutions.
Our affordable portfolio includes meticulously inspected and certified refurbished units, providing significant cost savings while meeting stringent performance standards. Additionally, we offer ex-demonstration models that have been lightly used and fully serviced, presenting an excellent opportunity to acquire high-quality equipment at a reduced price. For facilities with very specific and essential biosafety needs, our entry-level systems offer foundational Class II protection, ensuring a safe working environment for routine microbiological procedures.
| Option Type | Key Benefit | Ideal For |
|---|---|---|
| Refurbished Units | Significant cost savings | Hospitals, clinics, and research labs with limited capital budgets. |
| Demo Models | High quality at a reduced price | Facilities seeking near-new performance without the premium cost. |
| Entry-Level Systems | Essential biosafety compliance | Smaller labs, educational institutions, or those performing basic microbiological tasks. |
Explore Our Value-Driven Solutions:
- Refurbished Class II Safety Cabinets: Fully reconditioned and tested units offering reliable performance at a fraction of the new cost.
- Ex-Demonstration Models: Near-new cabinets with minimal use, thoroughly inspected and certified for optimal functionality.
- Entry-Level Systems: Cost-effective solutions designed for essential biosafety requirements in budget-constrained environments.
Verified Microbiology Safety Cabinet (Class Ii) Suppliers In Burkina Faso
When investing in a Class II Microbiology Safety Cabinet for your facility in Burkina Faso, partnering with a trusted supplier is paramount. Franance Health stands out as a premier provider, ensuring you receive not only state-of-the-art equipment but also unparalleled support. We understand the critical nature of biosafety and offer a robust solution that prioritizes your laboratory's safety, efficiency, and compliance.
Why Choose Franance Health for Your Class II Microbiology Safety Cabinet?
- Direct OEM Partnerships: At Franance Health, we cultivate strong, direct relationships with leading Original Equipment Manufacturers (OEMs) of microbiology safety cabinets. This ensures that you receive genuine, high-quality products directly from the source, guaranteeing authenticity and adherence to the strictest international safety standards. Our OEM partnerships allow us to offer competitive pricing and access to the latest innovations in biosafety technology.
- Dedicated Local Engineering Team: We believe in providing comprehensive support that extends beyond the initial sale. Franance Health boasts a dedicated team of highly skilled local engineers based in Burkina Faso. This means prompt and efficient installation, on-site maintenance, repair services, and regular servicing, all performed by professionals who understand the local context and are readily available to address your needs. This local presence significantly reduces downtime and ensures the continuous optimal performance of your safety cabinets.
- Comprehensive Warranty and Support: Your investment in a Class II Microbiology Safety Cabinet is protected by our comprehensive warranty. Franance Health offers robust warranty packages that cover parts and labor, providing you with peace of mind. Beyond the warranty period, our commitment to your success continues with ongoing technical support, readily available spare parts, and expert advice to ensure your equipment remains reliable and compliant throughout its lifespan.
Partner with Franance Health and secure a Class II Microbiology Safety Cabinet that meets the highest standards of safety and performance, backed by a team dedicated to your operational excellence in Burkina Faso.
Standard Configuration & Accessories
When you receive your Class II Microbiology Safety Cabinet in Burkina Faso, a comprehensive suite of components is included to ensure immediate and effective operation. Beyond the core cabinet, we equip you with essential features and optional add-ons designed for enhanced functionality and user convenience in your laboratory environment.
| Accessory Type | Description | Applicability |
|---|---|---|
| UPS (Uninterruptible Power Supply) | Provides battery backup to protect against power fluctuations and outages, ensuring continuous operation and sample safety. | Highly Recommended for all installations in Burkina Faso. |
| Ergonomic Stool | Adjustable height stool designed for comfort during extended laboratory work. | Optional, for user comfort. |
| UV Germicidal Lamp | Installed in the work area for post-work disinfection. | Optional, for enhanced decontamination. |
| Additional HEPA Filters | Spare filters for future maintenance and replacement. | Recommended for long-term operational continuity. |
| External Exhaust Blower (if required) | For Class II Type B2 cabinets, this ensures complete removal of exhaust gases from the laboratory. | Required for specific cabinet types (Type B2). |
| Specialized Work Surface Inserts | Options like ceramic or epoxy resin for specific chemical resistance or ease of cleaning. | Optional, for specific application needs. |
Included Standard Components:
- Main cabinet unit with pre-installed HEPA filters (supply and exhaust)
- Integrated LED lighting for optimal workspace illumination
- Durable, scratch-resistant stainless steel work surface
- Ergonomic front-opening sash with safety interlock
- Pre-piped gas or vacuum outlets (depending on model)
- Power cord and user manual
- Basic validation and start-up kit
Warranty & Maintenance Plans
We understand the critical nature of maintaining a sterile environment for your microbiological work. That's why we offer comprehensive warranty and maintenance plans for our Class II Microbiology Safety Cabinets in Burkina Faso. Our standard warranty provides peace of mind for your initial investment, covering manufacturing defects and ensuring your cabinet performs optimally from day one. Beyond the warranty period, our Preventive Maintenance (PPM) plans are designed to prolong the lifespan of your equipment, minimize downtime, and guarantee consistent biosafety performance. These plans include regular inspections, calibration, filter integrity testing, and essential servicing by our certified technicians. Furthermore, we ensure prompt availability of genuine spare parts, minimizing any potential disruptions to your research and clinical operations.
| Service Type | Description | Frequency |
|---|---|---|
| Standard Warranty | Covers manufacturing defects and initial operational performance. | Typically 12-24 months from installation. |
| Preventive Maintenance (PPM) - Basic | Includes visual inspection, filter integrity check, and basic cleaning. | Bi-annually. |
| Preventive Maintenance (PPM) - Comprehensive | Includes all basic PPM services plus calibration, fan motor check, and UV lamp testing (if applicable). | Annually. |
| Spare Parts Availability | Access to genuine OEM parts for timely repairs and replacements. | Guaranteed availability for current models. |
Key Features of Our Service Plans:
- Comprehensive standard warranty covering manufacturing defects.
- Regularly scheduled Preventive Maintenance (PPM) visits.
- HEPA filter integrity testing and replacement.
- Calibration and performance verification.
- On-site technical support and troubleshooting.
- Priority access to genuine spare parts.
Frequently Asked Questions

Ready whenever you are
Let's discuss your Microbiology Safety Cabinet (Class II) in Burkina Faso requirements in Burkina Faso.