Background
Verified Supplier in Angola

Radiation Dosimeter (TLD/Badge) in Angola Leading Radiation Dosimeter (TLD/Badge) Supplier

Buy Radiation Dosimeter (TLD/Badge) in Angola. Top suppliers, installation, and warranty from Franance Health. Get a quote today.

Contact Sales

Radiation Protection Monitoring

TLD badges provide essential personal dosimetry to measure cumulative radiation exposure for workers in Angola's nuclear medicine and industrial radiography sectors.

Long-Term Exposure Tracking

The reliable and cumulative nature of TLDs allows for consistent, long-term monitoring of radiation dose in Angola's evolving healthcare and research facilities.

Occupational Health Assurance

These dosimeters are crucial for ensuring the health and safety of personnel handling radioactive materials, supporting regulatory compliance in Angola.

What Is A Radiation Dosimeter (Tld/badge)?

In the context of medical imaging and radiation therapy in Angola, a Radiation Dosimeter, specifically a Thermoluminescent Dosimeter (TLD) badge, is a crucial personal monitoring device. It's designed to accurately measure and record the cumulative ionizing radiation dose received by an individual over a specific period. These small, wearable badges contain a material (typically a crystalline salt) that absorbs energy from ionizing radiation. When the badge is later analyzed in a specialized reader, this stored energy is released as light when heated, and the intensity of the emitted light is directly proportional to the amount of radiation the material was exposed to.

The primary function of a TLD badge is to ensure the safety of healthcare professionals who work in environments where they may be exposed to ionizing radiation, such as X-ray rooms, CT scanners, and radiotherapy departments. By providing a quantifiable record of radiation exposure, these dosimeters are essential for compliance with radiation safety regulations and for implementing ALARA (As Low As Reasonably Achievable) principles. This allows for proactive management of potential overexposures and informs decisions regarding workflow optimization and protective measures.

Key clinical applications for TLD badges in Angolan healthcare facilities include:

Key Clinical Applications

  • Radiology Departments: Monitoring exposure for radiologists, radiographers, and support staff working with diagnostic X-ray, fluoroscopy, and CT equipment.
  • Radiation Oncology: Ensuring the safety of radiation therapists, medical physicists, and oncologists involved in delivering radiation treatment.
  • Nuclear Medicine: Tracking radiation doses for technicians and physicians handling radioactive isotopes for diagnostic and therapeutic purposes.
  • Interventional Cardiology/Radiology: Safeguarding personnel during procedures involving prolonged fluoroscopic guidance and high radiation doses.
  • Research and Development: For personnel involved in studies utilizing ionizing radiation.

Who Needs Radiation Dosimeter (Tld/badge) In Angola?

In Angola, the use of Radiation Dosimeters, specifically Thermoluminescent Dosimeters (TLDs) or personal badges, is crucial for ensuring the safety and compliance of individuals working with ionizing radiation. These devices provide a quantitative measure of cumulative radiation exposure, enabling organizations to monitor occupational doses and implement necessary protective measures. The primary need for TLDs/badges extends across various healthcare and industrial facilities where radiation-generating equipment is in operation or where radioactive materials are handled.

Facility TypeSpecific Departments/Applications
Teaching HospitalsRadiology, Nuclear Medicine, Oncology (Radiotherapy), Cardiology, Interventional Radiology, Surgical Fluoroscopy
General Hospitals & Clinics (with X-ray services)Radiology, Diagnostic Imaging, Orthopedics
Specialized Cancer Treatment CentersRadiotherapy, Medical Physics
Industrial FacilitiesQuality Control, Welding Inspection, Material Testing
Research & DevelopmentLaboratories handling radioisotopes for research purposes

Key Facilities and Departments Requiring Radiation Dosimeters:

  • Hospitals and Diagnostic Imaging Centers
  • Radiotherapy Centers
  • Nuclear Medicine Departments
  • Interventional Cardiology and Radiology Suites
  • Surgical Departments Utilizing Fluoroscopy
  • Industrial Radiography and Non-Destructive Testing Facilities
  • Research Laboratories Working with Radioactive Isotopes
  • Veterinary Clinics Employing X-ray Equipment

Installation Process For Radiation Dosimeter (Tld/badge)

Ensuring the accurate and reliable operation of your radiation dosimeter (TLD/badge) system in Angola is paramount for workplace safety and regulatory compliance. Our comprehensive installation process is designed to be efficient, thorough, and tailored to your specific facility requirements.

Site Preparation: Prior to delivery, we will work with your team to identify optimal locations for dosimeter storage and management. This typically involves assessing areas with controlled access, adequate lighting, and proximity to relevant personnel. For TLD readers, a stable power source and a dedicated workspace are essential.

Delivery and Initial Setup: Upon arrival in Angola, our certified technicians will oversee the secure delivery of all equipment. This includes the dosimeter badges themselves, any necessary readers or analysis equipment, and associated accessories. An initial visual inspection will be conducted to confirm all components are present and undamaged.

Installation Steps: Our technicians will then proceed with the on-site installation, which may include:

  • Setting up and configuring TLD reader units, ensuring proper connection to power and data interfaces.
  • Organizing and distributing dosimeter badges to designated personnel, ensuring proper assignment and recording.
  • Installing any required software for data management and analysis, including user training.
  • Verifying system connectivity and basic functionality.

Calibration Requirements: Calibration is a critical step to guarantee the accuracy of your radiation measurements. All TLD readers will undergo an initial factory calibration before shipment, and we will perform on-site verification upon installation. Ongoing calibration services are essential for maintaining compliance and are available through our Angolan service network. We recommend periodic calibration according to international standards and local regulatory guidelines. Our team will advise on the specific calibration schedule best suited for your operations.

How Much Is A Radiation Dosimeter (Tld/badge) In Angola?

The cost of a radiation dosimeter (TLD/badge) in Angola can vary significantly based on whether you opt for a brand-new unit or a reliable refurbished model. For new TLD badges, you can generally expect prices to range from 25,000 Kz to 75,000 Kz per unit. This price range reflects the latest technology, manufacturer warranties, and often includes initial calibration services. Refurbished TLD badges offer a more budget-friendly option, typically falling between 10,000 Kz and 35,000 Kz. While refurbished units are thoroughly inspected and tested to ensure functionality, it's crucial to source them from reputable suppliers who can provide documentation on their refurbishment process and any remaining warranty.

Several factors influence these price points, including the specific type of TLD badge (e.g., finger rings, whole-body badges), the manufacturer, the included features (such as real-time monitoring capabilities or data logging), and the volume of your purchase. For bulk orders, discounts are often available, making it more cost-effective for facilities requiring multiple dosimeters.

Dosimeter TypeEstimated Price Range (New)Estimated Price Range (Refurbished)
Standard TLD Badge25,000 Kz - 50,000 Kz10,000 Kz - 25,000 Kz
Advanced/Specialized TLD Badge40,000 Kz - 75,000 Kz20,000 Kz - 35,000 Kz

Factors Influencing Price:

  • New vs. Refurbished Status
  • Manufacturer and Brand Reputation
  • Specific Features and Technology
  • Volume of Purchase (Bulk Discounts)
  • Included Services (Calibration, Warranty)

Affordable Radiation Dosimeter (Tld/badge) Options

Understanding the critical need for reliable radiation monitoring while adhering to budgetary constraints, we offer a range of value-focused TLD/badge dosimeter solutions specifically tailored for healthcare facilities in Angola. Our commitment is to ensure that every professional working with radiation has access to essential safety equipment without compromising on quality or performance. Explore our cost-effective options, designed to meet diverse needs and budgets.

Our Affordable Solutions Include:

  • Refurbished TLD/Badge Systems: Fully functional and rigorously tested, our pre-owned dosimeters provide the same level of accuracy and reliability as new units at a significantly reduced price point. Each refurbished system undergoes a comprehensive inspection and certification process to guarantee its performance.
  • Demo Models: Gain access to the latest technology through our carefully maintained demonstration units. These dosimeters have been used for showcasing purposes only and offer a cost-effective way to acquire advanced radiation monitoring capabilities.
  • Entry-Level TLD/Badge Systems: For facilities prioritizing essential safety features and seeking a straightforward, dependable solution, our entry-level models offer robust performance at an accessible price. These systems are ideal for routine monitoring and compliance requirements.

Verified Radiation Dosimeter (Tld/badge) Suppliers In Angola

When seeking reliable radiation dosimetry solutions in Angola, particularly for TLD (Thermoluminescent Dosimeter) badges, partnering with a trusted supplier is paramount. Franance Health stands out as a premier provider, ensuring your personnel are protected with accurate and traceable radiation monitoring.

<b>Why Choose Franance Health for Your Radiation Dosimetry Needs?</b>

  • <b>Exclusive OEM Partnerships:</b> We maintain direct and strong partnerships with leading Original Equipment Manufacturers (OEMs) of radiation dosimeters. This ensures that every TLD badge and associated system we supply in Angola adheres to the highest international standards for quality, accuracy, and reliability. Our OEM relationships guarantee access to the latest technologies and genuine components, eliminating concerns about counterfeit or substandard equipment.
  • <b>Dedicated Local Engineering Team:</b> Understanding the unique operational landscape in Angola, Franance Health has invested in a skilled and responsive local engineering team. This team is equipped to provide on-site installation, calibration, maintenance, and troubleshooting for your TLD/badge systems. Their local presence means faster response times, reduced downtime, and support that is culturally attuned and readily available, ensuring your radiation safety program runs seamlessly.
  • <b>Comprehensive Warranty and Support:</b> We back our commitment to quality with robust warranty provisions for all our radiation dosimeter products. Beyond the initial purchase, Franance Health offers ongoing technical support and service packages tailored to your specific needs. This comprehensive warranty and support structure provides peace of mind, knowing that your investment is protected and that you have a reliable partner for the long term in Angola.

By choosing Franance Health, you are not just purchasing radiation dosimeters; you are investing in a secure, compliant, and continuously supported radiation safety program for your operations in Angola.

Standard Configuration & Accessories

Our Radiation Dosimeter (TLD/Badge) systems for Angola are designed for comprehensive and reliable personal dosimetry. The standard configuration is optimized for ease of use, data management, and regulatory compliance. When you procure a system, you can expect a complete package to get you started immediately. This typically includes:

ComponentDescriptionTypical Role in Angolan Operations
TLD BadgesWearable devices containing TLD crystals to accumulate radiation dose.Essential for individual monitoring in healthcare, industrial, and research settings in Angola.
TLD Reader/AnalyzerDevice to heat TLDs and measure light output, correlating to absorbed radiation.Central to processing exposure data from all monitored personnel.
Software SuiteApplication for data acquisition, analysis, dose calculation, and reporting.Crucial for compliance with Angolan radiation safety regulations and workplace health monitoring.
Calibration StandardsKnown radiation sources for verifying reader accuracy.Ensures the reliability and legal defensibility of reported dose measurements in Angola.
Power SupplyStandard AC power adapter for the reader.Ensures the operational readiness of the primary analysis equipment.

What's Included in the Standard Package:

  • Thermoluminescent Dosimeter (TLD) Badges: A set of individual badges, pre-calibrated and ready for distribution to personnel requiring radiation monitoring. The quantity can be customized based on your operational needs.
  • TLD Reader/Analyzer: The core component for processing the TLD badges. This unit precisely measures the accumulated radiation dose stored within the TLD crystals.
  • Dose Calculation & Reporting Software: User-friendly software designed for importing TLD readings, calculating dose equivalents, managing personnel data, and generating compliance reports as per Angolan regulations.
  • Calibration Standards: Certified calibration sources to ensure the accuracy and traceability of your dosimetry measurements.
  • Personnel Data Management System: Tools to register, track, and manage individual worker dosimetry records.
  • User Manuals & Training Materials: Comprehensive documentation and guidance to facilitate efficient operation and maintenance of the system.
  • Power Cables and Basic Connectivity Hardware

Warranty & Maintenance Plans

We understand the critical nature of reliable radiation dosimetry for your operations in Angola. To ensure the longevity and accuracy of your TLD/Badge readers and associated systems, we offer comprehensive warranty and maintenance plans tailored to meet your specific needs. Our standard warranty provides robust coverage against manufacturing defects, giving you peace of mind from the moment of purchase. Beyond the initial warranty period, our Preventive Maintenance Program (PPM) is designed to proactively identify and address potential issues, minimizing downtime and ensuring consistent performance. We maintain a dedicated stock of genuine spare parts readily available for prompt dispatch to Angola, further reinforcing our commitment to minimizing service interruptions and supporting your ongoing dosimetry requirements.

Service TypeCoverage DetailsAvailability in Angola
Standard WarrantyCovers manufacturing defects for [Duration, e.g., 12 months] post-installation.Included with all new purchases.
Preventive Maintenance (PPM)Scheduled inspections, calibration, cleaning, and performance checks.Offered as a multi-year contract; service visits coordinated based on agreement.
Spare Parts AvailabilityGenuine TLD/Badge reader components and accessories.Maintained in regional stock for rapid deployment to Angola.

Key Features of Our Plans:

  • Standard Manufacturer's Warranty
  • Flexible Preventive Maintenance Contracts
  • On-site and Remote Support Options
  • Priority Access to Genuine Spare Parts
In-Depth Guidance

Frequently Asked Questions

Background
Phase 02: Execution

Ready whenever you are

Let's discuss your Radiation Dosimeter (TLD/Badge) in Angola requirements in Angola.