Respiratory/ICU

Ventilator Fleet Management & PM Service in Nigeria

Preventive maintenance and fleet management for ICU ventilators

Call Service Desk

Turnkey Delivery

Scope, project management & OEM documentation

Certified Engineers

Biomedical & IT teams deployed nationwide

Response Within 24h

Dedicated service desk for Nigerian facilities

Ventilator Fleet Management & PM service in Nigeria

Ventilator Fleet Management & PM Service in Nigeria - Price, Providers, Scope & SLA

Ventilator Fleet Management & Preventive Maintenance (PM) Service is a structured program to ensure your facility's entire fleet of ventilators—from ICU units like the Dräger Evita V300 to transport models like the Hamilton-C1—remains clinically effective, safe, and compliant. This service is essential for any Nigerian hospital, from large federal teaching hospitals in Lagos and Abuja to private clinics and NGO-supported facilities in Kano or Port Harcourt, that relies on ventilators for critical care. It directly solves the pain points of unexpected equipment failure during patient use, spiraling emergency repair costs, loss of accreditation, and the inability to provide accurate uptime reports to management or international donors. By outsourcing, you shift the burden of sourcing certified engineers, managing spare parts logistics, and maintaining complex service records to a specialist partner, allowing your clinical teams to focus on patient outcomes.

Ventilator Fleet Management & PM Service price in Nigeria

Ad-hoc, per-incident ventilator PM service costs between NGN 80,000 - NGN 150,000 per unit, per visit, excluding parts and major travel. A bundled annual PM contract for a small fleet (5-10 units) typically ranges from NGN 750,000 - NGN 2,500,000, while a turnkey comprehensive fleet management contract covering labour, all PM parts, and guaranteed uptime can range from NGN 3,000,000 to over NGN 10,000,000 annually, depending on fleet size and complexity.

Cost drivers include the mix of ventilators (a high-end ICU ventilator like a GE CARESCAPE R860 is more complex and costly to service than a basic transport ventilator), the age and condition of the fleet, and your location, which impacts engineer travel logistics from hubs like Lagos or Abuja. Other factors are the level of documentation required (e.g., for donor reporting or ISO accreditation), the urgency of response times defined in an SLA, the inclusion of parts, and compliance requirements like electrical safety testing and calibration using certified gas flow analyzers.

  • Cost levers you control:
    • Fleet Standardization: Standardizing on fewer models (e.g., focusing on either Philips or Dräger) simplifies training, parts stocking, and service expertise.
    • Contract Duration: Committing to a multi-year contract (2-3 years) often secures a 10-15% annual discount compared to a single-year agreement.
    • Service Bundling: Combining ventilator PM with service for patient monitors, anesthesia machines, or infusion pumps under a single provider can reduce overall costs.
    • Site Readiness: Ensuring easy access to equipment, stable power, and a designated contact person reduces the engineer's time on-site, lowering labour costs.
    • Flexible SLAs: Opting for a next-business-day response for non-critical issues instead of a 4-hour response for everything can significantly lower contract prices.

For a precise cost breakdown tailored to your specific fleet and operational needs, you need a detailed quote.

cheapest Ventilator Fleet Management & PM Service in Nigeria

The cheapest ventilator PM service in Nigeria can be found for as low as NGN 45,000 - NGN 70,000 per unit for a basic "check and clean" visit. This price typically excludes critical tasks like performance verification with a calibrated gas flow analyzer, replacement of mandatory PM kit components (like oxygen sensors, filters, or seals), detailed service reports required for accreditation, and any guarantee on workmanship.

The risks of these minimal-scope services are significant. You often get an uncertified technician with no specific training on your models, like the Hamilton-G5 or Philips Respironics V60. Hidden costs emerge when the "cheap" service fails to identify a developing fault, leading to a catastrophic failure and an expensive emergency call-out (NGN 150,000+). There is usually no documentation to prove maintenance for regulatory bodies or donors, no warranty on the service, and response times for any follow-up issues are unpredictable. This approach prioritizes a low initial invoice over patient safety and asset longevity.

  • Checklist before accepting low quotes:
    • Does the quote explicitly list the test equipment to be used (e.g., Fluke VT900A Gas Flow Analyzer)?
    • Does it include the cost of the manufacturer-specified PM kit for your model?
    • Will you receive a detailed, signed service report with measured values and pass/fail criteria for each test?
    • Is the engineer certified by the OEM (e.g., Dräger, Hamilton, GE) for the specific models in your fleet?
    • Does the provider have valid CAC registration and professional indemnity insurance?
    • Is there a warranty on the labour and any parts installed?

If the answer to most of these is "no," the cheap quote will likely cost you more in the long run.

affordable Ventilator Fleet Management & PM Service in Nigeria

An affordable, value-optimized ventilator service bundle costs between NGN 600,000 and NGN 1,800,000 annually for a small fleet, paid quarterly or annually. This approach moves beyond single-visit pricing to a predictable operational expense that delivers maximum value and uptime.

The core of an affordable bundle is proactive, scheduled maintenance that prevents costly failures. This includes biannual PM visits by certified engineers who follow scheduled routes, reducing travel costs. It also incorporates remote triage via phone or video call to resolve minor issues without a site visit, and a digital asset management portal that provides data on fleet status, service history, and uptime—critical for both internal management and donor reporting. By bundling these services, you get predictable costs, improved equipment reliability, and documented compliance without paying a premium for a fully comprehensive contract.

  • Bundle components for value:
    • Scheduled PM: Two planned maintenance visits per ventilator per year.
    • Electrical Safety Testing: Annual testing and certification for all units.
    • Remote Technical Support: A dedicated hotline for immediate troubleshooting.
    • Asset Register & Digital Records: Access to a CMMS portal to track service history and compliance.
    • Discounted Labour: A reduced rate (15-25% off) for any emergency repairs needed outside of PM.
    • Priority Response: Guaranteed response times (e.g., 24-48 hours) for corrective maintenance requests.

This bundled approach provides a strategic balance between cost and quality for most Nigerian healthcare facilities.

Ventilator Fleet Management & PM Service contract cost in Nigeria (AMC vs CMC)

An Annual Maintenance Contract (AMC), which typically covers only labour for preventive and corrective maintenance, ranges from NGN 750,000 - NGN 2,500,000 annually for a fleet of 10 ICU ventilators. A Comprehensive Maintenance Contract (CMC), which includes labour, all required spare parts, and PM kits, costs significantly more, ranging from NGN 4,000,000 - NGN 9,000,000 for the same fleet.

The choice depends on your budget predictability and risk tolerance. An AMC offers a lower initial cost, but you face unpredictable, often high, expenses whenever a major part like a turbine, oxygen sensor, or main PCB fails. This can disrupt your cash flow. A CMC provides total cost predictability—you pay one fixed fee for the year, and the service provider bears the entire risk of component failure. This is often preferred by facilities with strict budgeting, high-stakes critical care units, or donor-funded projects that require fixed costs.

FeatureAnnual Maintenance Contract (AMC)Comprehensive Maintenance Contract (CMC)
CostLower upfront (NGN 750k - 2.5M)Higher upfront (NGN 4M - 9M)
LabourIncludedIncluded
Spare PartsExcluded (Billed separately)Included (All parts covered)
BudgetingUnpredictable (risk of high part costs)Fully predictable (fixed annual cost)
Uptime FocusProvider incentivized by call-outsProvider incentivized to prevent failures
Best ForFacilities with strong in-house parts budgetCritical units needing guaranteed uptime & budget certainty

A CMC aligns the provider's goals with yours—their profitability depends on your ventilators not breaking down.

request Ventilator Fleet Management & PM Service quote in Nigeria (Franance)

Get a detailed, transparent quote for your ventilator fleet from Franance's network of verified service providers today.

where to get Ventilator Fleet Management & PM Service in Nigeria (providers)

You can find qualified ventilator service providers through three main channels: OEM direct service teams (like those from Dräger or GE Healthcare), certified local partners of the OEMs, and reputable independent service organizations (ISOs). Most credible providers have their main operations in Lagos, Abuja, or Port Harcourt but offer nationwide coverage. The selection process should involve a formal Request for Proposal (RFP) that clearly outlines your fleet inventory, required service level (SLA), and documentation needs.

Your due diligence is critical. Insist on seeing a valid Corporate Affairs Commission (CAC) registration certificate (RC number). For technical credibility, demand proof of OEM accreditation or training certificates for the engineers who will service your specific models. Ask for their professional indemnity and public liability insurance certificates. Most importantly, request at least three references from hospitals similar to yours and actually call them to verify the provider's performance, response times, and professionalism. Franance simplifies this by pre-vetting all service partners on its platform, verifying their corporate, technical, and financial standing before they can even submit a quote.

  • Documents to insist on:
    • CAC Certificate of Incorporation.
    • Tax Clearance Certificate (TCC).
    • OEM Training Certificates for named engineers (e.g., "Hamilton Medical Certified Training for C1/T1").
    • Proof of ownership of calibrated test equipment (e.g., calibration certificate for their gas flow analyzer).
    • A list of recent clients with contact persons for reference checks.
    • Certificate of Insurance (Professional Indemnity & Public Liability).

Never engage a provider who cannot produce these basic documents.

Ventilator Fleet Management & PM Service providers in Nigeria — checklist

  • Corporate: Is the company registered with the CAC with a valid RC number?
  • Technical: Are their engineers OEM-certified for your specific ventilator models (e.g., Dräger Savina, Hamilton-G5)?
  • Instrumentation: Do they own and calibrate their own test equipment, especially a gas flow/ventilator analyzer?
  • Documentation: Can they provide sample service reports and calibration certificates that meet international standards?
  • SLA: Do they offer a formal Service Level Agreement (SLA) with guaranteed response times and penalty clauses?
  • Spare Parts: Do they have an established supply chain for genuine OEM parts and common PM kits?
  • Compliance: Do they understand Nigerian regulations from SON, NAFDAC, and NNRA (if applicable)?
  • Nationwide Reach: Can they demonstrate the ability to service your locations outside of Lagos/Abuja/PH?
  • References: Can they provide at least three verifiable references from other hospitals?
  • Insurance: Do they hold valid professional indemnity and public liability insurance?
  • Reporting: Do they offer a digital platform or CMMS for tracking service history and asset performance?
  • Financial Stability: Do they have the financial capacity to stock necessary parts and manage a long-term contract?

verified Ventilator Fleet Management & PM Service provider in Nigeria (Franance)

Franance provides access to a nationwide network of pre-vetted, OEM-certified engineers capable of managing complex ventilator fleets from manufacturers like Dräger, Hamilton, GE, Philips, and Mindray. Our service stack covers the entire lifecycle, from commissioning and preventive maintenance to emergency repairs and compliant decommissioning, with coverage extending from major hubs like Lagos and Kano to more remote locations through a coordinated logistics network.

We ensure quality and reliability through a multi-layered approach. Our platform handles the initial due diligence, contract management, and payment processing, while our verified partners execute the on-site technical work according to a mutually agreed Scope of Work (SOW) and Service Level Agreement (SLA). All service activities are tracked on our digital dashboard, giving you real-time visibility into your fleet's status, upcoming PM schedules, and historical service reports—perfect for internal audits and donor reporting.

  • Franance delivery layers:
    • Vetted Partner Network: Access to specialized, OEM-certified biomedical engineering firms.
    • Standardized SOW & SLA: Clear, enforceable contracts that protect your interests.
    • Digital Service Dashboard: A single portal to request service, track progress, and access all documentation.
    • Nationwide Logistics: Coordinated dispatch of engineers and parts across Nigeria.
    • Quality Assurance: Audits of service reports and verification of test equipment calibration.
    • Flexible Financing: Options to spread the cost of your annual service contract over several payments.

best Ventilator Fleet Management & PM Service provider in Nigeria

The "best" provider is the one that combines OEM-certified technical expertise for your specific fleet, has a proven logistical capacity to meet your SLA across all your locations, and provides transparent, auditable documentation. Top-tier providers are typically certified local partners of major brands (Dräger, Hamilton, GE) or highly reputable Independent Service Organizations (ISOs) with a strong track record in critical care equipment.

Evaluation should focus on tangible proof, not just claims. A superior provider will have a high engineer-to-contract ratio, ensuring someone is always available. They will own, not rent, advanced test equipment like the Fluke VT900A or TSI Certifier FA Plus and can show you current calibration certificates. Their reporting will be digital, detailed, and accessible 24/7 via a portal. Critically, they will have demonstrable experience with your exact mix of equipment—servicing a Philips Trilogy transport ventilator is different from servicing a Siemens Maquet Servo-u ICU ventilator.

  • How to validate provider claims:
    • Ask for a live demo: Request a walkthrough of their service reporting platform or CMMS dashboard.
    • Request engineer certificates: Don't just accept a general "we are certified" statement; ask for the actual certificates for the engineers who would be assigned to your account.
    • Verify test equipment: Ask for the serial number and last calibration date of the gas flow analyzer they will use.
    • Conduct deep reference checks: Ask their references specific questions about response times, first-time fix rates, and the quality of their documentation.
    • Review a sample SOW: Check for detailed checklists, inclusion of PM kits, and clear pass/fail criteria.

Ventilator Fleet Management & PM Service scope of work in Nigeria (SOW)

A standard Scope of Work (SOW) for ventilator PM includes a comprehensive set of checks, calibrations, and part replacements performed at a scheduled interval (typically semi-annually). The process begins with an initial assessment and inventory of your fleet, moves to the execution of PM tasks according to manufacturer specifications, includes performance verification and calibration, and concludes with detailed documentation and a formal handover. A typical PM service for a single ICU ventilator takes 2-4 hours.

The SOW is a legally binding document that details every task the engineer will perform. It starts with physical inspection (chassis, casters, mounts), cleaning of filters, and functional checks of all alarms and operating modes (e.g., V-AC, V-SIMV, CPAP). It then proceeds to the replacement of scheduled parts like O2 sensors, gaskets, and filters from an OEM-certified PM kit. The most critical phase is performance verification and calibration, where a gas flow analyzer is used to test delivered tidal volumes, pressures, PEEP, and oxygen concentrations against manufacturer specifications. The final steps are electrical safety testing and providing you with a detailed service report and calibration certificate for each asset.

  • Non-negotiables in the SOW:
    • A specific checklist of tasks to be performed, referencing the OEM service manual.
    • The explicit inclusion of the manufacturer's specified PM kit and parts.
    • Mandatory use of a calibrated gas flow/ventilator analyzer for performance verification.
    • A clause requiring a detailed service report for each ventilator, including as-found and as-left measurements.
    • Requirement for an electrical safety test with a printed or digital report.
    • Clear definition of pass/fail criteria for all tests.

how Ventilator Fleet Management & PM Service works in Nigeria (process & methodology)

The process begins with a kickoff meeting to agree on the SOW, schedule, and logistics. An engineer is then dispatched to your facility on the agreed date. Upon arrival, they report to the designated contact person and conduct the service based on a strict methodology guided by international standards like IEC 60601 and the specific OEM's service manual for that model.

The engineer uses calibrated instrumentation, such as a gas flow analyzer (e.g., Fluke ProSim 8) and an electrical safety analyzer, to perform tests. Data for every check—from alarm functionality to tidal volume accuracy—is captured digitally or on a detailed service sheet. Each parameter is compared against the manufacturer's specified pass/fail thresholds. For example, if a Dräger Savina 300 is set to deliver a tidal volume of 500ml, the measured output must be within the tolerance specified in the service manual (e.g., ±10%). If any parameter fails, the engineer performs troubleshooting and corrective actions, such as calibration adjustments or part replacement, and then re-tests until the unit passes. The process concludes with the affixing of a service tag showing the service date and next due date, followed by the generation of a comprehensive report.

  • Methodology checklist:
    • Pre-service: Confirm schedule, verify PM kit availability, and review the asset's service history.
    • On-site Arrival: Sign in, conduct safety check, and confirm the correct asset with the clinical user.
    • Execution: Follow the OEM service manual checklist step-by-step.
    • Testing: Use calibrated instruments to verify all outputs (volume, pressure, FiO2, etc.).
    • Documentation: Record all findings, measurements, and parts replaced in the service report.
    • Handover: Review the service report with the biomedical lead or clinical head, obtain sign-off, and attach the service sticker.
    • Post-service: Upload the signed report to the central CMMS or customer portal.

Ventilator Fleet Management & PM Service SLA in Nigeria (response & uptime targets)

A typical Service Level Agreement (SLA) in Nigeria offers tiered response times based on issue severity: Critical (patient on device, total failure) requires a 2-4 hour telephone response and an 8-24 hour on-site engineer arrival, depending on location. Urgent (device not usable but no patient attached) targets a 24-48 hour on-site response. Routine (minor issues, PM scheduling) is handled within standard business hours.

Your SLA is the most important part of your service contract, as it defines the provider's commitment to you. It should clearly define these tiers, the exact window for on-site arrival (e.g., 24 business hours for Abuja, 48 for a remote site), and the role of remote triage to attempt a faster fix. A strong SLA includes penalty clauses for non-compliance, such as a percentage credit on your next invoice if the provider misses a guaranteed response time. It should also define a target for "Uptime," often aiming for 98% operational availability for the entire fleet, calculated monthly.

  • SLA clauses to include:
    • Definitions: Clear definitions of "Critical," "Urgent," and "Routine" failures.
    • Response Times: Separate, guaranteed times for telephone response and on-site engineer arrival for each severity level.
    • Business Hours: Definition of service hours (e.g., 8am-5pm Mon-Fri) and terms for after-hours support.
    • Penalty Clause: A specific financial penalty (e.g., 5% service credit) for each missed response time target.
    • Uptime Guarantee: A target fleet uptime percentage (e.g., 98%) with remedies if the target is missed for consecutive months.
    • Escalation Path: Named contacts and timelines for escalating unresolved issues.

Ventilator Fleet Management & PM Service SLA in Nigeria (Franance)

Define, monitor, and enforce your ventilator fleet SLA through the Franance platform, with real-time dashboards tracking response times and uptime for full accountability.

Ventilator Fleet Management & PM Service documentation and certificates in Nigeria

Upon completion of a service, you must receive a comprehensive documentation package for each ventilator. This includes a detailed Service Report, a Certificate of Calibration, and an updated asset register.

The Service Report is the most critical document. It should detail the asset's information (make, model, serial number), the work performed, all qualitative checks (pass/fail), and the quantitative results of performance verification tests (e.g., "Set Tidal Volume: 450ml, Measured: 448ml"). It must also list any parts replaced, including their part numbers. The Certificate of Calibration formally attests that the device's performance was tested against a traceable standard using calibrated equipment. Finally, your provider should help you maintain a master asset register or update your CMMS with the latest service date, next PM due date, and a link to the digital service report. This complete documentation trail is non-negotiable for hospital accreditation, legal defense, and satisfying donor audit requirements.

  • Files auditors demand:
    • Signed Service Reports: For every service intervention on every single ventilator.
    • Calibration Certificates: For each device, showing traceability to a known standard.
    • Master PM Schedule: A forward-looking plan showing when each ventilator is due for its next PM.
    • Engineer Qualification Records: Proof that the person who serviced the equipment was certified to do so.
    • Test Equipment Calibration Certificates: The certificate for the gas flow analyzer used during the service.

Ventilator Fleet Management & PM Service compliance in Nigeria (NAFDAC, SON/SONCAP, NNRA, IEC/ISO)

Compliance involves ensuring your ventilators and the service performed on them meet the requirements of several Nigerian regulatory bodies. NAFDAC governs the initial registration and importation of medical devices. The Standards Organisation of Nigeria (SON) enforces technical standards, often through its SONCAP program for imports, ensuring devices meet safety and performance benchmarks, typically aligned with IEC/ISO standards (like IEC 60601). While NNRA (Nigerian Nuclear Regulatory Authority) is not typically involved with ventilators, any service provider working in a hospital must be aware of radiation safety protocols if working near diagnostic imaging suites.

Your service provider's work must not invalidate your device's compliance. They must use OEM-approved parts and follow certified procedures. Their documentation serves as your proof of proper maintenance, which is essential during any inspection by SON or the Ministry of Health. For facilities seeking international accreditation like JCI or COHSASA, the service methodology and documentation must align with global best practices and ISO standards for quality management. A competent provider will understand these intersecting requirements and deliver a service and documentation package that satisfies all of them.

  • Compliance actions per authority:
    • NAFDAC: Ensure your provider uses only NAFDAC-registered spare parts and consumables where applicable.
    • SON: Verify your service provider's procedures and reports align with SON's adopted IEC standards for medical device safety and performance.
    • Ministry of Health (Federal & State): Maintain a complete and accessible file of service reports for all ventilators, as this is a key part of hospital inspections and licensing.
    • ISO/Accreditation Bodies: Ensure your provider's documentation (service reports, calibration certificates) is detailed enough to pass an external audit.

Ventilator Fleet Management & PM Service preventive maintenance checklist in Nigeria

A proper preventive maintenance schedule involves a full PM service every six months or per the OEM's recommendation, whichever is more frequent. The process should be planned weeks in advance to minimize clinical disruption.

The PM visit itself is a structured event. The engineer arrives with the correct PM kit, tools, and calibrated test equipment. They work through a detailed checklist that covers functional, mechanical, and electronic systems. Digital logs are superior as they enforce completion of every step and provide a time-stamped record. The entire process for a single ICU ventilator, from initial checks to final report generation, should take between 2 to 4 hours.

  • Core PM tasks:
    • External Inspection: Check chassis, casters, mounting arms, and accessory integrity.
    • Filter Replacement: Replace all air intake, cooling fan, and patient circuit filters.
    • Pneumatic System: Replace seals, O-rings, and other components included in the OEM PM kit.
    • Alarm Verification: Test all audible and visual alarms (e.g., High Pressure, Low Volume, Apnea).
    • Power System Check: Test battery backup, charging function, and AC power failure alarm.
    • Performance Verification: Use a gas flow analyzer to test and calibrate tidal volume, flow, pressure, PEEP, and FiO2 delivery.
    • Electrical Safety Test: Measure earth leakage, chassis leakage, and ground bond resistance.
    • Cleaning: Clean external surfaces and internal components as specified by the manufacturer.

Ventilator Fleet Management & PM Service emergency repair in Nigeria

The emergency response process begins the moment your clinical staff identifies a critical fault and calls the provider's support hotline. The first step is immediate remote triage: a senior engineer will guide your staff through basic troubleshooting to try and resolve the issue over the phone (e.g., resolving a simple circuit leak or incorrect setting). This can resolve up to 30% of issues without a site visit.

If remote triage fails, the SLA is activated. The dispatcher identifies the nearest available certified engineer and confirms spare part availability. The engineer is dispatched with the goal of arriving on-site within the SLA window (e.g., 8 hours for Lagos, 24 for a remote city). They arrive with common spare parts for the fault described. Upon arrival, they diagnose the unit, perform the repair, and conduct a full performance verification test to ensure the ventilator is safe and ready for clinical use before handing it back.

  • Emergency playbook:
    • Step 1 (0-15 mins): Clinical staff calls the dedicated 24/7 support number with the ventilator's asset ID and a description of the fault.
    • Step 2 (15-60 mins): Remote triage by a specialist engineer to attempt an immediate fix.
    • Step 3 (1-3 hours): If unresolved, a job is logged, an engineer is assigned, and logistics (parts, travel) are confirmed.
    • Step 4 (3-24 hours): Engineer travels to the site and commences diagnosis and repair.
    • Step 5 (On-site): Repair is completed, the unit is fully tested and calibrated, and a service report is signed by hospital staff.
    • Step 6 (Post-visit): The case is closed, and the report is uploaded to the client portal.

Ventilator Fleet Management & PM Service spare parts and logistics in Nigeria

Genuine OEM spare parts availability, lead times, and costs are major challenges in Nigeria. A reliable provider mitigates this by maintaining a local stock of high-failure and routine PM parts (like oxygen sensors, flow sensors, filters, and PM kits) for common ventilator models. Lead time for locally stocked parts can be 24-48 hours. However, for major, non-stocked components (like turbines or main PCBs), the lead time can be 2-4 weeks due to international shipping, customs clearance, and SONCAP processes.

A professional service provider will have a robust logistics system. They will only use authentic, OEM-guaranteed parts to ensure patient safety and device performance—never grey market or refurbished parts unless explicitly agreed upon for older equipment. They manage the entire importation and customs clearance process, providing you with a single, all-inclusive price for the part. You should have visibility into their stocking strategy and be able to query the availability and lead time for critical components for your specific fleet.

  • Spare parts controls:
    • Authenticity Guarantee: A contractual clause guaranteeing that only genuine OEM parts will be used.
    • Local Stocking Agreement: Agreement on which critical parts the provider will hold in-stock locally for your fleet.
    • Transparent Pricing: A clear policy on markup for imported parts.
    • Warranty: Confirmation that the provider will extend the manufacturer's warranty on all parts they install.
    • Chain of Custody: Ability to track parts from order to installation.

Ventilator Fleet Management & PM Service training and handover in Nigeria

Training and handover should cover both clinical use and basic biomedical maintenance. A good service provider will offer role-based training: a 2-4 hour session for clinical staff (nurses, doctors) on proper use, alarm response, and pre-use checks, and a more technical 1-day session for your in-house biomedical staff on first-line troubleshooting, PM principles, and how to escalate issues effectively.

The handover after a PM or repair is a formal process. The service engineer should walk your designated biomedical or clinical lead through the service report, explaining the work done, the results of the performance tests, and any recommendations. They should not just leave a report on a desk. This ensures your team understands the status of the equipment and can confidently put it back into clinical service. Competency should be tracked, and refresher training should be scheduled annually or when new staff join.

  • Training deliverables:
    • User Training Manual: A simplified guide for clinical staff.
    • Technical Training Slides: For the biomedical team.
    • Certificate of Attendance: For all participants.
    • Competency Checklist: To verify understanding of key tasks.
    • Access to Online Resources: Links to manufacturer training videos and materials.

Ventilator Fleet Management & PM Service asset inventory and CMMS in Nigeria

A Computerized Maintenance Management System (CMMS) provides a centralized digital platform to manage your entire ventilator fleet, tracking everything from asset location to service history and performance KPIs. Instead of relying on paper files or spreadsheets, a CMMS gives you a real-time dashboard view of your fleet's health.

The process starts with physical asset tagging of each ventilator with a unique ID (barcode or QR code). This ID is used to log all service activities—PMs, repairs, calibrations—against that specific device. The CMMS then uses this data to track critical KPIs like Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), total downtime, and service costs per asset. This data is invaluable for making informed decisions about equipment replacement, justifying budgets, and proving compliance to auditors and donors. Franance provides a CMMS dashboard as a standard part of its managed service contracts.

  • CMMS data points:
    • Asset Details: Make, model, serial number, location, purchase date.
    • Service History: Every PM and repair report ever filed for the asset.
    • PM Schedule: A calendar showing upcoming and overdue maintenance tasks.
    • KPI Dashboard: Real-time charts for Uptime, MTTR, MTBF, and costs.
    • Documentation Library: A repository for user manuals, service manuals, and certificates.
    • Work Order Management: A system to request new service and track its progress.

Ventilator Fleet Management & PM Service power audit and UPS/stabilizer sizing in Nigeria

A power audit is a systematic process to assess the quality and stability of the electrical supply to your critical care equipment. Given Nigeria's power instability, this is a crucial first step in any fleet management program. The audit involves using a power quality analyzer to measure voltage, frequency, surges, sags, and harmonics at the wall sockets powering your ventilators over a period of 24-72 hours.

The outcome is a detailed report that identifies power-related risks to your equipment. Based on this report, the provider will recommend and correctly size mitigation solutions. This isn't just about buying any UPS; it's about sizing a UPS (e.g., a 2kVA online double-conversion unit) to handle the ventilator's specific power draw and provide enough runtime to bridge the gap until the hospital generator kicks in. It may also involve specifying a servo-motor stabilizer to protect the sensitive electronics from constant voltage fluctuations. This proactive step prevents the most common cause of electronic failure in Nigerian hospitals.

  • Power audit outcomes:
    • A detailed report with graphs showing voltage and frequency stability over time.
    • Identification of specific risks like frequent over-voltage, under-voltage, or "dirty" power.
    • Specific recommendations for UPS type (e.g., online vs. line-interactive), KVA rating, and required battery runtime.
    • Recommendations for voltage stabilizers or other power conditioning equipment.
    • An implementation plan to protect your entire ventilator fleet.

Ventilator Fleet Management & PM Service relocation and commissioning in Nigeria

The relocation and commissioning process involves the safe de-installation, transport, and re-installation of ventilators, typically taking 2-5 days depending on distance and complexity. This service is critical when moving equipment to a new ward, a new hospital building, or even a different city.

The process is meticulous. An engineer first performs a full functional test of the ventilator at the old location to establish a performance baseline. The unit is then properly de-installed, and sensitive components are secured. It is professionally packaged with anti-static and shock-absorbent materials for transport. Upon arrival at the new site, the engineer unpacks, reassembles, and installs the ventilator. The most critical step is the final commissioning: a full performance verification and calibration are performed to ensure the unit was not damaged in transit and is performing to OEM specifications in its new environment. Only after this validation is the ventilator handed over for clinical use.

  • Relocation safeguards:
    • Pre-move validation: A full PM check to confirm the unit is working before it's moved.
    • Professional packaging: Use of custom crates or manufacturer-specified packaging.
    • Insured transport: Using a logistics partner with "goods in transit" insurance.
    • Post-move commissioning: A complete performance verification and calibration at the new site.
    • Documentation: A report confirming the successful relocation and performance validation.

Ventilator Fleet Management & PM Service deinstallation and disposal in Nigeria

The deinstallation and disposal process is a formal procedure to safely remove end-of-life ventilators from service in compliance with environmental and data security regulations, costing between NGN 50,000 - NGN 120,000 per unit.

The process begins with a certified engineer safely de-installing the unit from its gas and power supplies. If the ventilator contains any patient data, the internal memory or hard drive must be securely wiped or physically destroyed to comply with data privacy standards. The unit is then stripped of any hazardous materials (like certain batteries) which must be disposed of according to environmental regulations. A formal chain-of-custody document, or "Certificate of Disposal," is issued, which serves as your legal proof that the asset was disposed of responsibly. This is a critical step to remove the asset from your hospital's official inventory.

  • Decommission essentials:
    • Safe De-installation: Performed by a qualified engineer.
    • Data Sanitization: A certificate confirming that all patient data has been destroyed.
    • Hazardous Waste Management: Proper handling of batteries and electronic waste.
    • Asset Tag Removal: Removing all hospital identification from the device.
    • Certificate of Disposal: A legal document confirming the compliant disposal of the asset.

Ventilator Fleet Management & PM Service quality control and performance verification in Nigeria

Quality control and performance verification is a continuous process, not a one-time event. It involves scheduled checks, typically semi-annually during PM, to ensure each ventilator is performing within the manufacturer's original specifications.

The core of QC is objective measurement. An engineer uses a calibrated ventilator analyzer to precisely measure the parameters the ventilator is delivering—tidal volume, respiratory rate, PEEP, peak pressure, and oxygen concentration. These measured values are compared against the settings on the ventilator. The results are recorded, and any deviation outside the acceptable tolerance (e.g., +/- 5%) triggers a calibration or repair. This rigorous, data-driven process is the only way to be certain that a ventilator is safe and effective for patient use. Trend analysis of this data over time can also predict future failures.

  • QC checkpoints:
    • Tidal Volume Accuracy: Is the delivered volume within 5-10% of the set volume?
    • PEEP Accuracy: Does the measured PEEP match the set PEEP within +/- 2 cmH2O?
    • FiO2 Accuracy: Is the delivered oxygen concentration within +/- 3% of the set value?
    • Alarm Function: Do all critical alarms trigger at their correct setpoints?
    • Leak Test: Does the pneumatic circuit pass the internal leak test?

Ventilator Fleet Management & PM Service electrical safety testing in Nigeria

Electrical safety testing is a mandatory, non-negotiable part of any ventilator service, performed at least annually. The process involves using a specialized electrical safety analyzer to test the device's electrical systems to ensure they are safe for both patients and clinical staff, in line with IEC 60601-1 standards.

The engineer performs a series of tests, including measuring the resistance of the protective earth connection (ground bond), and checking for any dangerous levels of current leakage from the chassis or patient connections. The test results, along with the pass/fail status, are recorded in the service report. A passing unit is affixed with an electrical safety sticker indicating the test date and the next due date. This documentation is your primary evidence of electrical safety compliance during any hospital audit or in the event of an adverse incident.

  • Electrical safety deliverables:
    • Protective Earth Resistance Test: Ensures the device is properly grounded.
    • Insulation Resistance Test: Checks for degradation in wiring insulation.
    • Leakage Current Test: Measures chassis and patient-applied part leakage currents.
    • A Detailed Test Report: Showing the measured values and pass/fail status for each test.
    • A Dated Safety Tag: Affixed to the device's power cord or chassis.

Ventilator Fleet Management & PM Service KPIs and reporting in Nigeria

The key metrics (KPIs) tracked for ventilator fleet management are Uptime Percentage, Mean Time To Repair (MTTR), Mean Time Between Failures (MTBF), and First Visit Fix Rate. Reporting is typically provided monthly via a digital dashboard and a summary report.

These KPIs tell you the story of your fleet's health and your service provider's performance. Uptime % (ideally >98%) shows the operational availability of your fleet. MTTR measures how quickly your provider fixes a broken device from the moment it's reported. MTBF indicates the reliability of the equipment itself. A high First Visit Fix Rate (>90%) shows your provider is effective at diagnosing issues and bringing the right parts the first time. Access to a real-time dashboard allows you to monitor these metrics yourself, while a monthly report provides a strategic overview for management meetings and budget planning.

  • KPIs to review monthly:
    • Fleet Uptime %: The percentage of time the entire fleet was available for use.
    • Mean Time To Repair (MTTR): The average time taken from reporting a fault to completing the repair.
    • Mean Time Between Failures (MTBF): The average time a specific device works without failing.
    • SLA Attainment %: The percentage of times the provider met the guaranteed response times.
    • PM Completion Rate: The percentage of scheduled PMs completed on time.
    • Cost per Asset: The total maintenance cost (labour + parts) for each ventilator.

Ventilator Fleet Management & PM Service payment terms in Nigeria

Payment options typically include quarterly or semi-annual payments in advance for service contracts (AMCs/CMCs), or payment upon completion for ad-hoc repairs. Milestone billing is common for large, multi-site projects.

For annual contracts, the total contract value is usually divided into 2 or 4 equal payments, due at the beginning of each service period. Some providers may require a performance bond from their bank to guarantee service delivery, especially on large government or NGO contracts. For high-value, multi-year CMCs, some providers, like Franance, can offer financing options that spread the cost into more manageable monthly payments. All terms, including billing cycles, payment due dates, and penalties for late payment, should be clearly defined in the service contract.

  • Finance clauses to agree:
    • Billing Cycle: Monthly, quarterly, or semi-annually.
    • Payment Due Date: E.g., "Net 30 days from date of invoice."
    • Currency: Specify NGN or USD and the agreed exchange rate mechanism if applicable.
    • Advance Payment: The percentage of the contract value required upfront.
    • Withholding Tax (WHT): A clause stating that the client will provide a WHT credit note.
    • Financing Options: Availability of third-party financing to spread costs.

Ventilator Fleet Management & PM Service near me in Nigeria (nationwide coverage)

Service is available nationwide, with primary engineering hubs in Lagos, Abuja, Port Harcourt, and Kano, and satellite support covering most state capitals. This hub-and-spoke model allows for rapid response in major cities and scheduled, cost-effective service delivery to facilities in more remote areas.

Franance leverages this model to provide comprehensive national coverage. Our Lagos and Abuja hubs serve as primary logistics and engineering centers, supporting the South-West, North-Central, and North-West regions. Our Port Harcourt hub covers the South-South and South-East, while our Kano presence anchors service delivery across the North. For facilities outside these immediate zones, we use a combination of scheduled service routes to bundle PM visits for multiple clients in a region, reducing travel costs, and a robust remote support desk for immediate troubleshooting. This ensures that whether you are in Ikeja or Ikot Ekpene, you have access to the same high standard of ventilator support.

  • Coverage highlights:
    • Major Hubs: On-site response within 8-24 hours in Lagos, Abuja, Port Harcourt.
    • State Capitals: On-site response within 24-48 hours.
    • Remote Locations: Scheduled PM visits and a 48-72 hour target for emergency response.
    • Remote Support: Immediate 24/7 telephone and video support available to all locations.
    • Parts Logistics: Overnight shipping of parts from central hubs to regional locations.
Ready when you are

Let's scope your Ventilator Fleet Management & PM project

Share your requirements for rollout, training and SLAs. Our service desk will prepare budgets, documentation and timelines aligned to your facility.

Call service desk

30+ Years

Experience delivering healthcare projects in Nigeria

OEM Certified

Biomedical & IT teams for installation, calibration & support

Nationwide

Coverage across Lagos, Abuja, Port Harcourt, Kano & beyond

Ventilator Fleet Management & PM Service in Nigeria – Frequently Asked Questions

Honest answers about scope, pricing, delivery and support so you can plan with confidence.

How much does a ventilator Annual Maintenance Contract (AMC) cost in Nigeria?

A ventilator AMC in Nigeria costs between ₦150,000 and ₦400,000 per unit annually, excluding parts. The price depends on the model's complexity and age. For example, a contract for a newer Hamilton-C1 will be on the lower end, while an older, more complex GE CARESCAPE R860 may be higher. A Comprehensive Maintenance Contract (CMC), which includes parts, typically costs 10-15% of the equipment's value.

What is the typical response time for emergency ventilator repair in Lagos?

The standard response time for emergency ventilator repair in Lagos is 4-6 hours for providers with a local service team. A strong Service Level Agreement (SLA) should guarantee an engineer on-site within this window for critical equipment like a Dräger Savina 300. For facilities outside major hubs like Ikeja or VI, expect a 12-24 hour response unless a premium SLA is in place. Always confirm the provider’s engineer and parts depot location.

What's included in a standard ventilator Preventive Maintenance (PM) service?

A standard ventilator PM service includes a full functional check, calibration of flow and pressure sensors, battery performance testing, and replacement of scheduled parts like O-rings and filters. For a model like the Philips Respironics V60, this involves running a full Performance Verification Test (PVT) using a certified gas flow analyzer. You will receive a detailed service report and a calibration certificate for your records.

Should my hospital choose an OEM or third-party provider for ventilator service?

A certified third-party provider is often more cost-effective and flexible for Nigerian hospitals with multi-brand ventilator fleets. While an OEM provides deep expertise on their specific models, like Hamilton Medical for the G5, a third-party can service your entire fleet of Dräger, GE, and Mindray ventilators under one contract. This simplifies procurement and can reduce overall maintenance costs by 15-25% annually.

How do I verify a ventilator service provider's qualifications in Nigeria?

Verify a provider's qualifications by requesting OEM training certificates for their engineers on your specific models, like the Mindray SV300. Ask for references from other Nigerian hospitals of similar size, such as Reddington or EKO Hospital. Also, confirm they use calibrated, industry-standard testing equipment like the Fluke VT900A Gas Flow Analyzer and can provide proof of recent calibration for their tools.

What is the difference between an AMC and a CMC for ventilators?

An Annual Maintenance Contract (AMC) covers only labour for scheduled preventive maintenance and emergency call-outs. A Comprehensive Maintenance Contract (CMC) includes both labour and the cost of all required spare parts. For a high-use ventilator like the GE Engström Carestation, a CMC provides predictable budgeting by eliminating unexpected costs from expensive component failures, such as an O2 sensor or exhalation valve.

How can I finance a large ventilator fleet service contract?

You can finance a large service contract through specialized healthcare equipment financing solutions like those from Franance. This converts the large, upfront annual cost into predictable quarterly or monthly operational payments. This approach allows you to implement a comprehensive PM program for your entire fleet of, for example, 20+ Hamilton and Dräger ventilators without draining your capital budget, ensuring compliance and uptime.

What documentation should I receive after a ventilator PM service?

After each PM service, you must receive a detailed service report and a calibration certificate. The report for a ventilator like the Hamilton-C1 should list all tests performed, parts replaced (e.g., filter, O2 cell), and final calibration values for flow, pressure, and oxygen concentration. This documentation is critical for internal quality assurance, hospital accreditation, and demonstrating regulatory compliance.

How often should a hospital ventilator undergo preventive maintenance?

Hospital ventilators require preventive maintenance at least once a year, though some manufacturers recommend semi-annual service. The OEM service manual for your specific model, such as the Dräger Evita V300, dictates the exact schedule and required part replacements. High-usage environments, like ICUs in major Lagos or Abuja hospitals, should strictly adhere to a semi-annual schedule to prevent unexpected failures.

What are the key terms to look for in a ventilator service SLA?

Key SLA terms include guaranteed uptime (e.g., 98%), maximum response time (e.g., 4 hours in-city), and resolution time (e.g., 24 hours for critical issues). The SLA should also specify the availability of loaner units if a repair on your primary ventilator, like a Philips Trilogy Evo, is expected to exceed 48 hours. Also, ensure it clearly defines penalties for non-compliance with these terms.

Is it better to have an in-house biomedical team or outsource ventilator maintenance?

Outsourcing is generally better unless your hospital has over 50 ventilators and a dedicated, OEM-certified in-house team. The cost of specialized test equipment, like a ₦5-7 million gas flow analyzer, plus continuous training for diverse models like the GE CARESCAPE and Mindray SV series, makes outsourcing more financially viable. It provides access to a wider range of expertise and parts inventory without the high overhead.

How long does a typical on-site ventilator PM service take?

A typical on-site PM service for a single ventilator takes between 2 to 4 hours. This includes disassembly, cleaning, parts replacement, calibration, and safety testing. For a model like the Mindray SV600, the engineer will run a full diagnostic and performance verification cycle. Scheduling this during off-peak hours minimizes disruption to your ICU or critical care workflow.

What is the process for onboarding a new ventilator fleet management provider?

The onboarding process takes 2-4 weeks and involves four key steps. First is the initial asset audit, where the provider inspects and tags each ventilator (e.g., your Dräger and Hamilton units). Second is contract finalization (SLA and pricing). Third is scheduling the first round of PMs. Finally, the provider integrates your facility into their service call system for logging repair requests and tracking.

Can a single provider manage a mixed fleet of different ventilator brands?

Yes, a qualified third-party service provider can manage a mixed fleet of different brands. This is a major advantage, as they have engineers trained on various models like the Dräger Savina, Hamilton-C1, and Philips V60. This consolidates your service contracts, simplifies vendor management, and often results in cost savings compared to using multiple OEM service providers for each brand in your hospital.

What spare parts should my hospital stock for our ventilators?

Your hospital should stock basic user-replaceable consumables like breathing circuits, filters, and exhalation valve diaphragms for your specific models. For a ventilator like the Hamilton-G5, keeping a spare O2 cell is also wise. Avoid stocking major electronic boards or pneumatic components, as these are expensive and best managed by your service provider, who should guarantee their availability within their SLA.

How does a service provider handle ventilator software updates?

A reputable service provider manages software updates as part of a comprehensive service contract. They will identify necessary updates for your models, like the GE CARESCAPE R860, based on manufacturer service bulletins. The update is then scheduled during a planned PM visit to minimize downtime. This ensures your equipment benefits from the latest performance improvements and safety patches without burdening your in-house team.

What happens if a ventilator fails during a power outage?

If a ventilator fails during a power outage, its internal battery should provide backup power for a specified duration, typically 1-4 hours for a model like the Dräger Babylog VN500. Your service contract's emergency protocol should be initiated immediately. The service provider's SLA should guarantee a rapid response even outside business hours to diagnose if the failure is battery-related or a more serious system fault.

Are ventilator service costs in Abuja different from Lagos?

Yes, service costs can be 10-20% higher in Abuja and other regions compared to Lagos due to logistics. Providers headquartered in Lagos may add travel and accommodation costs for dispatching engineers to Abuja. To manage this, choose a provider with a documented engineering presence and parts depot in the North, or negotiate a contract that includes travel costs for a predictable, fixed fee.

What are the compliance requirements for ventilator testing in Nigeria?

Ventilator testing must comply with Standards Organisation of Nigeria (SON) guidelines and international standards like IEC 60601. This requires performance and electrical safety testing using calibrated equipment. Your service provider must issue a certificate of calibration after each PM for every device, like a Mindray SV300. This documentation is essential for hospital accreditation and regulatory audits.

How can I reduce my hospital's overall ventilator maintenance spending?

Reduce spending by consolidating all your ventilators, regardless of brand, under a single third-party multi-year contract. This provides volume discounts. Also, opt for a CMC over an AMC to create a predictable budget and avoid surprise costs for major parts like turbines or motherboards on older models. Finally, ensure your staff perform daily checks as per the user manual to catch minor issues early.

What is a 'loaner unit' policy in a ventilator service contract?

A 'loaner unit' policy is a contractual guarantee that the service provider will supply a replacement ventilator if a repair on your unit is expected to take longer than a specified time, typically 48 hours. This is a critical clause for ensuring continuity of care. For a specialized device like a Hamilton-MR1 used in an MRI suite, ensure the loaner unit is also MRI-compatible.

How are payment terms structured for ventilator service contracts in Nigeria?

Payment terms are typically structured as an annual upfront payment, which often includes a 5-10% discount. Alternatively, semi-annual or quarterly payments are common for larger contracts to ease cash flow. For fleet-wide contracts, financing options like those from Franance can convert the entire cost into manageable monthly payments, aligning the service expense with your operational budget cycle.

What training is provided to hospital staff under a fleet management service?

A good fleet management service includes basic user training for your clinical staff and biomedical technicians. This covers daily checks, proper cleaning procedures, circuit changes, and basic troubleshooting for common alarms on models like the Philips Respironics V60. This empowers your team to resolve minor issues instantly, reducing unnecessary service calls and equipment downtime.

How do service providers manage parts for obsolete or older ventilator models?

Service providers manage parts for older models, like a Siemens Servo 300, through a network of third-party suppliers and by harvesting components from decommissioned units. However, availability is not always guaranteed. A key part of a fleet management audit is to identify such end-of-life equipment and develop a phased replacement plan to mitigate the risk of unrepairable failures.

What is the escalation process for an unresolved ventilator issue?

A standard escalation process involves three levels. Level 1 is the field service engineer. If the issue on your GE Engström isn't resolved within the SLA's timeframe (e.g., 24 hours), it escalates to Level 2, the regional service manager. Level 3 is the national technical lead or director, who can authorize OEM support or a unit replacement. This entire process should be clearly documented in your service contract.

Can I get a discount for a multi-year ventilator service agreement?

Yes, you can typically secure a 10-15% discount by signing a multi-year (3-5 year) service agreement. This provides cost stability for your hospital and business security for the provider. It's an effective way to lock in current pricing and reduce the annual procurement workload for a large fleet of ventilators, such as your hospital's 25+ Mindray and Dräger units.

What is the role of a gas flow analyzer in ventilator PM?

A gas flow analyzer, like a Fluke VT650 or TSI Certifier, is essential for accurate ventilator PM. It independently measures delivered volume, flow, pressure, and oxygen percentage to verify the ventilator is performing to manufacturer specifications. Without this external verification for a device like the Hamilton-C6, calibration is merely an internal adjustment, not a certified confirmation of clinical accuracy.

How does a fleet management service track asset history?

A fleet management service uses a Computerized Maintenance Management System (CMMS) to track the complete history of each ventilator. Every unit, like your Dräger Evita V500, is given a unique asset tag. All service calls, PMs, parts replaced, and costs are logged against this tag. This provides a detailed lifecycle record, which is crucial for making data-driven decisions on equipment replacement and budget forecasting.

What is the typical warranty on ventilator repair work and spare parts?

The typical warranty on ventilator repair work and spare parts is 90 days for labour and 6-12 months for the specific parts replaced. For a major component replacement, like a new turbine assembly on a Philips Respironics V60, you should expect a minimum 12-month warranty on that part. Ensure this is clearly stated in your service agreement to protect against premature failure of new components.

How do I decommission and dispose of an old ventilator in Nigeria?

Decommissioning involves having a certified biomedical engineer perform a final safety check and formally document that the unit is being removed from service. For disposal, first contact your service provider, as they may offer a trade-in value or buy it for spare parts. Otherwise, you must follow local environmental guidelines for e-waste disposal, which may involve contracting a specialized waste management company in your state.